Your browser doesn't support javascript.
loading
Detection of acute coronary occlusion with a novel mobile electrocardiogram device: a pilot study.
Zepeda-Echavarria, Alejandra; van de Leur, Rutger R; Vessies, Melle; de Vries, Nynke M; van Sleuwen, Meike; Hassink, Rutger J; Wildbergh, Thierry X; van Doorn, J L; van der Zee, Rien; Doevendans, Pieter A; Jaspers, Joris E N; van Es, René.
Afiliación
  • Zepeda-Echavarria A; Department of Medical Technology and Clinical Physics, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.
  • van de Leur RR; Department of Cardiology, University Medical Center Utrecht, Utrecht University, Internal ref E03.511, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.
  • Vessies M; Department of Cardiology, University Medical Center Utrecht, Utrecht University, Internal ref E03.511, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.
  • de Vries NM; Department of Cardiology, University Medical Center Utrecht, Utrecht University, Internal ref E03.511, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.
  • van Sleuwen M; Department of Cardiology, University Medical Center Utrecht, Utrecht University, Internal ref E03.511, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.
  • Hassink RJ; Department of Cardiology, University Medical Center Utrecht, Utrecht University, Internal ref E03.511, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.
  • Wildbergh TX; Department of Cardiology, Meander Medical Center Amersfoort, Amersfoort, The Netherlands.
  • van Doorn JL; Department of Cardiology, Meander Medical Center Amersfoort, Amersfoort, The Netherlands.
  • van der Zee R; Stichting Cardiovasculaire Biologie, Delft, The Netherlands.
  • Doevendans PA; Department of Cardiology, University Medical Center Utrecht, Utrecht University, Internal ref E03.511, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.
  • Jaspers JEN; Netherlands Heart Institute, Utrecht, The Netherlands.
  • van Es R; Central Military Hospital, Utrecht, The Netherlands.
Eur Heart J Digit Health ; 5(2): 183-191, 2024 Mar.
Article en En | MEDLINE | ID: mdl-38505481
ABSTRACT

Aims:

Many portable electrocardiogram (ECG) devices have been developed to monitor patients at home, but the majority of these devices are single lead and only intended for rhythm disorders. We developed the miniECG, a smartphone-sized portable device with four dry electrodes capable of recording a high-quality multi-lead ECG by placing the device on the chest. The aim of our study was to investigate the ability of the miniECG to detect occlusive myocardial infarction (OMI) in patients with chest pain. Methods and

results:

Patients presenting with acute chest pain at the emergency department of the University Medical Center Utrecht or Meander Medical Center, between May 2021 and February 2022, were included in the study. The clinical 12-lead ECG and the miniECG before coronary intervention were recorded. The recordings were evaluated by cardiologists and compared the outcome of the coronary angiography, if performed. A total of 369 patients were measured with the miniECG, 46 of whom had OMI. The miniECG detected OMI with a sensitivity and specificity of 65 and 92%, compared with 83 and 90% for the 12-lead ECG. Sensitivity of the miniECG was similar for different culprit vessels.

Conclusion:

The miniECG can record a multi-lead ECG and rule-in ST-segment deviation in patients with occluded or near-occluded coronary arteries from different culprit vessels without many false alarms. Further research is required to add automated analysis to the recordings and to show feasibility to use the miniECG by patients at home.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Eur Heart J Digit Health Año: 2024 Tipo del documento: Article País de afiliación: Países Bajos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Eur Heart J Digit Health Año: 2024 Tipo del documento: Article País de afiliación: Países Bajos