Your browser doesn't support javascript.
loading
Multi-Stimuli Operando Transmission Electron Microscopy for Two-Terminal Oxide-Based Devices.
Recalde-Benitez, Oscar; Pivak, Yevheniy; Winkler, Robert; Jiang, Tianshu; Adabifiroozjaei, Esmaeil; Perez-Garza, H Hugo; Molina-Luna, Leopoldo.
Afiliación
  • Recalde-Benitez O; Advanced Electron Microscopy Division, Institute of Materials Science, Department of Materials and Geosciences, Technische Universität Darmstadt, Peter-Grünber-strasse 2, Darmstadt 64287, Germany.
  • Pivak Y; DENSsolutions BV, Informaticalaan 12, Delft 2628 ZD, The Netherlands.
  • Winkler R; Advanced Electron Microscopy Division, Institute of Materials Science, Department of Materials and Geosciences, Technische Universität Darmstadt, Peter-Grünber-strasse 2, Darmstadt 64287, Germany.
  • Jiang T; Advanced Electron Microscopy Division, Institute of Materials Science, Department of Materials and Geosciences, Technische Universität Darmstadt, Peter-Grünber-strasse 2, Darmstadt 64287, Germany.
  • Adabifiroozjaei E; Advanced Electron Microscopy Division, Institute of Materials Science, Department of Materials and Geosciences, Technische Universität Darmstadt, Peter-Grünber-strasse 2, Darmstadt 64287, Germany.
  • Perez-Garza HH; DENSsolutions BV, Informaticalaan 12, Delft 2628 ZD, The Netherlands.
  • Molina-Luna L; Advanced Electron Microscopy Division, Institute of Materials Science, Department of Materials and Geosciences, Technische Universität Darmstadt, Peter-Grünber-strasse 2, Darmstadt 64287, Germany.
Microsc Microanal ; 30(2): 200-207, 2024 Apr 29.
Article en En | MEDLINE | ID: mdl-38526872
ABSTRACT
The integration of microelectromechanical systems (MEMS)-based chips for in situ transmission electron microscopy (TEM) has emerged as a highly promising technique in the study of nanoelectronic devices within their operational parameters. This innovative approach facilitates the comprehensive exploration of electrical properties resulting from the simultaneous exposure of these devices to a diverse range of stimuli. However, the control of each individual stimulus within the confined environment of an electron microscope is challenging. In this study, we present novel findings on the effect of a multi-stimuli application on the electrical performance of TEM lamella devices. To approximate the leakage current measurements of macroscale electronic devices in TEM lamellae, we have developed a postfocused ion beam (FIB) healing technique. This technique combines dedicated MEMS-based chips and in situ TEM gas cells, enabling biasing experiments under environmental conditions. Notably, our observations reveal a reoxidation process that leads to a decrease in leakage current for SrTiO3-based memristors and BaSrTiO3-based tunable capacitor devices following ion and electron bombardment in oxygen-rich environments. These findings represent a significant step toward the realization of multi-stimuli TEM experiments on metal-insulator-metal devices, offering the potential for further exploration and a deeper understanding of their intricate behavior.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Microsc Microanal Año: 2024 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Microsc Microanal Año: 2024 Tipo del documento: Article País de afiliación: Alemania