Your browser doesn't support javascript.
loading
Magneto-dynamic tool for full arch immediate loading in post-traumatic restoration with narrow implants: A case report.
Cervino, Gabriele; Fiorillo, Luca; Scotti, Nicola; Motta, Francesco Alessandro; Motta, Francesco Maria; Colombo, Jacopo; Heboyan, Artak; Baldi, Domenico.
Afiliación
  • Cervino G; Department of Biomedical and Dental Sciences, Morphological and Functional Images, University of Messina, Messina, Italy.
  • Fiorillo L; Department of Biomedical and Dental Sciences, Morphological and Functional Images, University of Messina, Messina, Italy.
  • Scotti N; Multidisciplinary Department of Medical-Surgical and Odontostomatological Specialties, University of Campania 'Luigi Vanvitelli', Naples, Italy.
  • Motta FA; Department of Dental Cell Research, Dr. D.Y. Patil Dental College & Hospital, Dr. D.Y. Patil Vidyapeeth, Pune, Maharashtra, India.
  • Motta FM; Department of Surgical Sciences, University of Turin, Turin, Italy.
  • Colombo J; Division of Prosthetic Dentistry, Department of Surgical Sciences (DISC), University of Genoa, Genoa, Italy.
  • Heboyan A; Division of Prosthetic Dentistry, Department of Surgical Sciences (DISC), University of Genoa, Genoa, Italy.
  • Baldi D; Division of Prosthetic Dentistry, Department of Surgical Sciences (DISC), University of Genoa, Genoa, Italy.
SAGE Open Med Case Rep ; 12: 2050313X241241191, 2024.
Article en En | MEDLINE | ID: mdl-38559405
ABSTRACT
New surgical techniques using narrow, tilted implants positioned through a magneto-dynamic tool in guided surgery for a Toronto restoration. A 69-year-old woman wanted fixed rehabilitation to replace her removable complete dentures. A cone-beam computed tomography showed significant bone resorption in both the maxillary and mandibular regions. The plan was to load the entire upper arch with six implants immediately, while removable partial dentures were recommended for the lower jaw. The guided surgery project was aligned with the new dentures, and the laboratory created a printed cast with dental implant analogues in planned positions. A metal-reinforced denture was constructed, and surgery was performed to place six narrow implants using the magneto-dynamic instrument. The denture was directly screwed onto multi-unit abutments. Final rehabilitation was completed after 6 months. Narrow implants can be a good option for fixed, full-arch rehabilitations. Further research is needed to confirm these findings on a larger scale.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: SAGE Open Med Case Rep Año: 2024 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: SAGE Open Med Case Rep Año: 2024 Tipo del documento: Article País de afiliación: Italia