Your browser doesn't support javascript.
loading
Development of a novel DGT passive sampler for measuring polycyclic aromatic hydrocarbons in aquatic systems.
Rong, Qiuyu; Li, Yanying; Luo, Jun; Yan, Liying; Jones, Kevin C; Zhang, Hao.
Afiliación
  • Rong Q; Lancaster Environment Centre, Lancaster University, Lancaster LA1 4YQ, United Kingdom.
  • Li Y; College of Environmental Science and Engineering, Dalian Maritime University, Dalian, Liaoning 116023, PR China.
  • Luo J; State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, Jiangsu 210023 PR China.
  • Yan L; State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, Jiangsu 210023 PR China.
  • Jones KC; Lancaster Environment Centre, Lancaster University, Lancaster LA1 4YQ, United Kingdom. Electronic address: k.c.jones@lancaster.ac.uk.
  • Zhang H; Lancaster Environment Centre, Lancaster University, Lancaster LA1 4YQ, United Kingdom. Electronic address: h.zhang@lancaster.ac.uk.
J Hazard Mater ; 470: 134199, 2024 May 15.
Article en En | MEDLINE | ID: mdl-38593660
ABSTRACT
Polycyclic aromatic hydrocarbons (PAHs) are priority pollutants and need to be measured reliably in waters and other media, to understand their sources, fate, behaviour and to meet regulatory monitoring requirements. Conventional water sampling requires large water volumes, time-consuming pre-concentration and clean-up and is prone to analyte loss or contamination. Here, for the first time, we developed and validated a novel diffusive gradients in thin-films (DGT) passive sampler for PAHs. Based on the well-known DGT principles, the sampler pre-concentrates PAHs with typical deployment times of days/weeks, with minimal sample handling. For the first time, DGT holding devices made of metal and suitable for sampling hydrophobic organic compounds were designed and tested. They minimize sorption and sampling lag times. Following tests on different binding layer resins, a MIP-DGT was preferred - the first time applying MIP for PAHs. It samples PAHs independent of pH (3.9 -8.1), ionic strength (0.01 -0.5 M) and dissolved organic matter < 20 mg L-1, making it suitable for applications across a wide range of environments. Field trials in river water and wastewater demonstrated that DGT is a convenient and reliable tool for monitoring labile PAHs, readily achieving quantitative detection of environmental levels (sub-ng and ng/L range) when coupled with conventional GC-MS or HPLC. ENVIRONMENTAL IMPLICATIONS PAHs are carcinogenic and genotoxic compounds. They are environmentally ubiquitous and must be monitored in waters and other media. This study successfully developed a new DGT passive sampler for reliable in situ time-integrated measurements of PAHs in waters at the ng/L level. This is the first time to use passive samplers for accurate measurements of hydrophobic organic contaminants in aquatic systems without calibration, a big step forward in monitoring PAHs. The application of this new sampler will enhance our understanding of the sources, fate, behavior and ecotoxicology of PAHs, enabling improved environmental risk assessment and management of these compounds.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Hidrocarburos Policíclicos Aromáticos / Contaminantes Químicos del Agua / Monitoreo del Ambiente Idioma: En Revista: J Hazard Mater Asunto de la revista: SAUDE AMBIENTAL Año: 2024 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Hidrocarburos Policíclicos Aromáticos / Contaminantes Químicos del Agua / Monitoreo del Ambiente Idioma: En Revista: J Hazard Mater Asunto de la revista: SAUDE AMBIENTAL Año: 2024 Tipo del documento: Article País de afiliación: Reino Unido