Your browser doesn't support javascript.
loading
Reliability of the TMS-evoked potential in dorsolateral prefrontal cortex.
Gogulski, Juha; Cline, Christopher C; Ross, Jessica M; Parmigiani, Sara; Keller, Corey J.
Afiliación
  • Gogulski J; Department of Psychiatry and Behavioral Sciences, Stanford University School of Medicine, 401 Quarry Road, Stanford, CA 94305, United States.
  • Cline CC; Wu Tsai Neurosciences Institute, Stanford University, 290 Jane Stanford Way, Stanford, CA 94305, United States.
  • Ross JM; Department of Clinical Neurophysiology, HUS Diagnostic Center, Clinical Neurosciences, Helsinki University Hospital and University of Helsinki, Haartmaninkatu 4, Helsinki FI-00029, Finland.
  • Parmigiani S; Department of Psychiatry and Behavioral Sciences, Stanford University School of Medicine, 401 Quarry Road, Stanford, CA 94305, United States.
  • Keller CJ; Wu Tsai Neurosciences Institute, Stanford University, 290 Jane Stanford Way, Stanford, CA 94305, United States.
Cereb Cortex ; 34(4)2024 Apr 01.
Article en En | MEDLINE | ID: mdl-38596882
ABSTRACT
We currently lack a reliable method to probe cortical excitability noninvasively from the human dorsolateral prefrontal cortex (dlPFC). We recently found that the strength of early and local dlPFC transcranial magnetic stimulation (TMS)-evoked potentials (EL-TEPs) varied widely across dlPFC subregions. Despite these differences in response amplitude, reliability at each target is unknown. Here we quantified within-session reliability of dlPFC EL-TEPs after TMS to six left dlPFC subregions in 15 healthy subjects. We evaluated reliability (concordance correlation coefficient [CCC]) across targets, time windows, quantification methods, regions of interest, sensor- vs. source-space, and number of trials. On average, the medial target was most reliable (CCC = 0.78) and the most anterior target was least reliable (CCC = 0.24). However, all targets except the most anterior were reliable (CCC > 0.7) using at least one combination of the analytical parameters tested. Longer (20 to 60 ms) and later (30 to 60 ms) windows increased reliability compared to earlier and shorter windows. Reliable EL-TEPs (CCC up to 0.86) were observed using only 25 TMS trials at a medial dlPFC target. Overall, medial dlPFC targeting, wider windows, and peak-to-peak quantification improved reliability. With careful selection of target and analytic parameters, highly reliable EL-TEPs can be extracted from the dlPFC after only a small number of trials.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Electroencefalografía / Estimulación Magnética Transcraneal Límite: Humans Idioma: En Revista: Cereb Cortex Asunto de la revista: CEREBRO Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Electroencefalografía / Estimulación Magnética Transcraneal Límite: Humans Idioma: En Revista: Cereb Cortex Asunto de la revista: CEREBRO Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos