Your browser doesn't support javascript.
loading
Experimental Study on Dynamic Characteristics of Damaged Post-Tensioning Concrete Sleepers Using Impact Hammer.
Choi, Jung-Youl; Shin, Tae-Hyung; Kim, Sun-Hee; Chung, Jee-Seung.
Afiliación
  • Choi JY; Department of Construction Engineering, Dongyang University, No. 145 Dongyangdae-ro, Punggi-eup, Yeongju-si 36040, Gyeongsangbuk-do, Republic of Korea.
  • Shin TH; Engineering HQ, Seoul Metro, 5, Hyoryeong-ro, Seocho-gu, Seoul 06693, Republic of Korea.
  • Kim SH; Department of Architectural Engineering, Gachon University, 1342 Seongnamdaero, Sujeong-gu, Seongnam-si 13120, Gyeonggi-do, Republic of Korea.
  • Chung JS; Department of Construction Engineering, Dongyang University, No. 145 Dongyangdae-ro, Punggi-eup, Yeongju-si 36040, Gyeongsangbuk-do, Republic of Korea.
Materials (Basel) ; 17(7)2024 Mar 29.
Article en En | MEDLINE | ID: mdl-38612095
ABSTRACT
Concrete sleepers in operation are commonly damaged by various internal and external factors, such as poor materials, manufacturing defects, poor construction, environmental factors, and repeated loads and driving characteristics of trains; these factors affect the vibration response, mode shape, and natural frequency of damaged concrete sleepers. However, current standards in South Korea require only a subjective visual inspection of concrete sleepers to determine the damage degree and necessity of repair or replacement. In this study, an impact hammer test was performed on concrete sleepers installed on the operating lines of urban railroads to assess the field applicability of the modal test method, with the results indicating that the natural frequency due to concrete sleeper damage was lower than that of the undamaged state. Furthermore, the discrepancy between the simulated and measured natural frequencies of the undamaged concrete sleeper was approximately 1.87%, validating the numerical analysis result. The natural frequency of the damaged concrete sleepers was lower than that of the undamaged concrete sleeper, and cracks in both the concrete sleeper core and the rail seat had the lowest natural frequency among all the damage categories. Therefore, the damage degrees of concrete sleepers can be quantitatively estimated using measured natural-frequency values.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Materials (Basel) Año: 2024 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Materials (Basel) Año: 2024 Tipo del documento: Article