Your browser doesn't support javascript.
loading
Abbreviated Urine Collection Compared With 24-Hour Urine Collection for Measuring Creatinine Clearance in Adult Critically Ill Patients: A Systematic Review.
Saad, Mohamed Omar; Mohamed, Adham; Mohamed Ibrahim, Mohamed Izham.
Afiliación
  • Saad MO; Pharmacy Department, Al Wakra Hospital, Hamad Medical Corporation, Doha, Qatar.
  • Mohamed A; Saint Luke's Hospital of Kansas City, Kansas City, MO, USA.
  • Mohamed Ibrahim MI; College of Pharmacy, QU Health, Qatar University, Doha, Qatar.
Ann Pharmacother ; : 10600280241241820, 2024 Apr 15.
Article en En | MEDLINE | ID: mdl-38619016
ABSTRACT

OBJECTIVE:

To evaluate the accuracy of abbreviated urine collection (≤12 hours) compared with 24-hour urine collection for measuring creatinine clearance (CrCl) in critically ill adult patients. DATA SOURCES We searched PubMed, Embase, Web of Science, Google Scholar, and ProQuest Dissertations and Thesis Global; screened reference lists of included studies; and contacted the authors when needed. English studies only were considered with no restriction on dates. STUDY SELECTION AND DATA EXTRACTION After duplicate removal, 2 reviewers screened titles/abstracts, reviewed full-text articles, and extracted data independently. Studies that compared abbreviated versus 24-hour urine collection for measuring CrCl were included. We assessed the risk of bias using the QUADAS-2 tool. We extracted correlation coefficients, mean prediction errors (ME)-as a measure of bias, and root mean squared prediction errors (RMSE)-as a measure of precision. DATA

SYNTHESIS:

Five studies were included, comprising 528 adult critically ill adults from surgical, medical, and trauma intensive care units (ICUs). Three studies had high risk of bias, and 2 had low risk. The studies evaluated different durations of urine collection, including 30-minute, 2-hour, 4-hour, 6-hour, and 12-hour. Mean 24-hour CrCl ranged from 57 mL/min/1.73 m2 to 103 mL/min. Abbreviated urine collection led to CrCl that correlated well with the 24-hour measured CrCl (correlation coefficient ranged from 0.8 to 0.95). Mean prediction error ranged from 5 mL/min/1.73 m2 to 16 mL/min (from 8% to 25% of the 24-hour CrCl). Root mean squared prediction error calculated from 1 study was 30.5 mL/min/1.73 m2. RELEVANCE TO PATIENT CARE AND CLINICAL PRACTICE Abbreviated urine collection is used to measure CrCl for renal drug dosing in critically ill patients, but its accuracy is not well-established.

CONCLUSIONS:

Abbreviated urine collection may overestimate CrCl compared with 24-hour urine collection. Larger, well-conducted studies are needed to evaluate the accuracy of CrCl measured using different durations of urine collection in critically ill patients.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Ann Pharmacother Asunto de la revista: FARMACOLOGIA / TERAPIA POR MEDICAMENTOS Año: 2024 Tipo del documento: Article País de afiliación: Qatar

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Ann Pharmacother Asunto de la revista: FARMACOLOGIA / TERAPIA POR MEDICAMENTOS Año: 2024 Tipo del documento: Article País de afiliación: Qatar