Your browser doesn't support javascript.
loading
Facile design of FeCu metal-organic frameworks anchored on layer Ti3C2Tx MXene for high-performance electrochemical sensing of resorcinol.
Zhang, Li; Han, Yu; Sun, Ming; Li, Fengbo; Li, Shaobin; Gui, Tao.
Afiliación
  • Zhang L; Key Laboratory of Polymeric Composite Materials of Heilongjiang Province, College of Materials Science and Engineering, Qiqihar University, Qiqihar, 161006, China.
  • Han Y; Key Laboratory of Polymeric Composite Materials of Heilongjiang Province, College of Materials Science and Engineering, Qiqihar University, Qiqihar, 161006, China.
  • Sun M; Key Laboratory of Polymeric Composite Materials of Heilongjiang Province, College of Materials Science and Engineering, Qiqihar University, Qiqihar, 161006, China.
  • Li F; College of Chemistry and Chemical Engineering, Qiqihar University, Qiqihar, 161006, China. Electronic address: lfb199210@163.com.
  • Li S; Key Laboratory of Polymeric Composite Materials of Heilongjiang Province, College of Materials Science and Engineering, Qiqihar University, Qiqihar, 161006, China. Electronic address: qqhrlsb1022@126.com.
  • Gui T; Key Laboratory of Polymeric Composite Materials of Heilongjiang Province, College of Materials Science and Engineering, Qiqihar University, Qiqihar, 161006, China.
Talanta ; 275: 126100, 2024 Aug 01.
Article en En | MEDLINE | ID: mdl-38626498
ABSTRACT
This work reports the rational design of a composite material by growing FeCu-MOF-919 on the surface of layered Ti3C2Tx MXene. The introduction of Ti3C2Tx MXene simultaneously weakens the aggregation of FeCu-MOF-919 and Ti3C2Tx MXene, which increases the electrochemical reaction active site of the composite material and improves the electrochemical activity. Interestingly, the FeCu-MOF-919/Ti3C2Tx based sensors were used to detect resorcinol (RS) with a wide linear range (0.5-152.5 µM), excellent sensitivity (0.23 µA µM-1 cm-2), low limit of detection (LOD = 0.08 µM) and outstanding stability. Meanwhile, the sensor shows high repeatability of 1.07 % RSD, reproducibility of 1.47 % RSD and anti-interference performance. What's more, the sensor can be successfully used to detect RS in tap water with good recoveries (96.25-103.37 %, RSD ≤2.18 %), demonstrating that the FeCu-MOF-919/Ti3C2Tx exhibits significant potential as an advanced sensing apparatus for the surveillance of RS in the natural environment.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Talanta Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Talanta Año: 2024 Tipo del documento: Article País de afiliación: China