Your browser doesn't support javascript.
loading
Microplastics and nanoplastics released from injection syringe, solid and liquid dimethylpolysiloxane (PDMS).
Fang, Cheng; Zhao, Lirong; Pu, Ruoqi; Lei, Yongjia; Zhou, Wenhao; Hu, Jiaqi; Zhang, Xian; Naidu, Ravi.
Afiliación
  • Fang C; Global Centre for Environmental Remediation (GCER), University of Newcastle, Callaghan, NSW 2308, Australia; CRC for Contamination Assessment and Remediation of the Environment (CRC CARE), University of Newcastle, Callaghan, NSW 2308, Australia. Electronic address: cheng.fang@newcastle.edu.au.
  • Zhao L; Global Centre for Environmental Remediation (GCER), University of Newcastle, Callaghan, NSW 2308, Australia; College of Environmental Sciences, Sichuan Agricultural University, Chengdu, Sichuan 611130, PR China.
  • Pu R; Global Centre for Environmental Remediation (GCER), University of Newcastle, Callaghan, NSW 2308, Australia; College of Environmental Sciences, Sichuan Agricultural University, Chengdu, Sichuan 611130, PR China.
  • Lei Y; College of Environmental Sciences, Sichuan Agricultural University, Chengdu, Sichuan 611130, PR China.
  • Zhou W; College of Chemistry and Materials, Jiangxi Agricultural University, Nanchang, Jiangxi 330045, PR China.
  • Hu J; College of Chemistry and Materials, Jiangxi Agricultural University, Nanchang, Jiangxi 330045, PR China.
  • Zhang X; Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, PR China.
  • Naidu R; Global Centre for Environmental Remediation (GCER), University of Newcastle, Callaghan, NSW 2308, Australia; CRC for Contamination Assessment and Remediation of the Environment (CRC CARE), University of Newcastle, Callaghan, NSW 2308, Australia.
J Hazard Mater ; 474: 134782, 2024 Aug 05.
Article en En | MEDLINE | ID: mdl-38824781
ABSTRACT
For a plastic syringe, a stopper at the end of plunger is usually made of polydimethylsiloxane (PDMS, and co-ingredients). To reduce friction and prevent leakage between the stopper and barrel, short chain polymer of liquid PDMS is also used as lubricant. Consequently, an injection process can release solid PDMS debris from the stopper and barrel, and liquid PDMS droplets from the lubricant, both of which are confirmed herein as solid and liquid micro(nano)plastics. From molecular spectrum perspective to directly visualise those micro(nano)plastics, Raman imaging was employed to analyse hundreds-to-thousands of spectra (hyper spectrum or hyperspectral matrix) and significantly enhance signal-to-noise ratio. From morphology perspective to provide high resolution of image, scanning electron microscopy (SEM) was engaged to cross-check with Raman images and increase assignment / quantification certainty. The weak Raman imaging signal of nanoplastics was extracted using image deconvolution algorithm to remove the background noise and average the signal variation. To increase the result's representativeness and avoid quantification bias, multiple syringes were tested and multiple areas were randomly scanned toward statistical results. It was estimated that thousands of microplastics and millions of nanoplastics of solid/liquid PDMS might be injected when using a plastic syringe of 1 mL. Overall, Raman imaging (along with algorithm and SEM) can be helpful for further research on micro(nano)plastics, and it should be cautious to use plastic syringe due to the increasing concern on the emerging contamination of not only solid but also liquid micro(nano)plastics.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: J Hazard Mater Asunto de la revista: SAUDE AMBIENTAL Año: 2024 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: J Hazard Mater Asunto de la revista: SAUDE AMBIENTAL Año: 2024 Tipo del documento: Article