Your browser doesn't support javascript.
loading
Innovative hemostasis technique for cesarean section in placenta previa: A retrospective study.
Kawakami, Kosuke; Kurokawa, Yusuke; Urago, Kohei; Maruyama, Yumika; Fujikawa, Rie; Ishibashi, Hiroki; Kitagawa, Marie; Shimizu, Takahiro; Tokuda, Tsugumichi; Kawagoe, Hidehiro; Muta, Mitsuru; Yoshizato, Toshiyuki; Okura, Naofumi.
Afiliación
  • Kawakami K; Department of Obstetrics and Gynecology, National Hospital Organization Kokura Medical Center, Kitakyushu, Japan.
  • Kurokawa Y; Department of Obstetrics and Gynecology, Kurume University School of Medicine, Kurume, Japan.
  • Urago K; Department of Obstetrics and Gynecology, National Hospital Organization Kokura Medical Center, Kitakyushu, Japan.
  • Maruyama Y; Department of Obstetrics and Gynecology, Kurume University School of Medicine, Kurume, Japan.
  • Fujikawa R; Department of Obstetrics and Gynecology, National Hospital Organization Kokura Medical Center, Kitakyushu, Japan.
  • Ishibashi H; Department of Obstetrics and Gynecology, Kurume University School of Medicine, Kurume, Japan.
  • Kitagawa M; Department of Obstetrics and Gynecology, National Hospital Organization Kokura Medical Center, Kitakyushu, Japan.
  • Shimizu T; Department of Obstetrics and Gynecology, National Hospital Organization Kokura Medical Center, Kitakyushu, Japan.
  • Tokuda T; Department of Obstetrics and Gynecology, National Hospital Organization Kokura Medical Center, Kitakyushu, Japan.
  • Kawagoe H; Department of Obstetrics and Gynecology, National Hospital Organization Kokura Medical Center, Kitakyushu, Japan.
  • Muta M; Department of Obstetrics and Gynecology, National Hospital Organization Kokura Medical Center, Kitakyushu, Japan.
  • Yoshizato T; Department of Obstetrics and Gynecology, National Hospital Organization Kokura Medical Center, Kitakyushu, Japan.
  • Okura N; Department of Obstetrics and Gynecology, National Hospital Organization Kokura Medical Center, Kitakyushu, Japan.
Article en En | MEDLINE | ID: mdl-39022881
ABSTRACT

OBJECTIVE:

To evaluate hemostatic efficacy, complications, and subsequent pregnancy outcomes in women with placenta previa who underwent combined vertical compression sutures in the lower uterine segment and intrauterine balloon tamponade (Hot-Dog method) to achieve hemostasis after cesarean section.

METHODS:

We retrospectively reviewed data for 117 women with singleton pregnancy diagnosed with placenta previa who underwent cesarean section between 29 and 38 weeks' gestation. Treatments were as follows (1) conventional-intravenous oxytocin administration after placental detachment and suturing of bleeding points at the detachment site as needed (conventional group) (n = 47). (2) Intrauterine balloon tamponade alone (balloon group) (n = 41). (3) Vertical compression sutures + intrauterine balloon tamponade (Hot-Dog group) (n = 29).

RESULTS:

The placenta accreta spectrum prevalence was significantly higher in the balloon and Hot-Dog groups versus the conventional group. The prevalence of anteriorly located placenta was significantly higher in the Hot-Dog versus balloon groups. Intraoperative and total blood loss were significantly higher in the Hot-Dog versus conventional groups. Postoperative blood loss was significantly lower in the Hot-Dog versus balloon groups. Fewer additional procedures for managing postoperative hemorrhage were required in the Hot-Dog versus conventional and balloon groups. The number of subsequent pregnancies in the conventional, balloon, and Hot-Dog groups was 11 (23.4%), 8 (19.5%), and 4 (13.8%), respectively; all resulted in live births at term without serious obstetric complications.

CONCLUSION:

The Hot-Dog method is a straightforward and safe hemostasis technique for placenta previa that preserves fertility and controls severe bleeding.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Int J Gynaecol Obstet Año: 2024 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Int J Gynaecol Obstet Año: 2024 Tipo del documento: Article País de afiliación: Japón