Your browser doesn't support javascript.
loading
Anesthesia Practitioners' Goals for Sevoflurane Minimum Alveolar Concentration at the End of Surgery and the Incidence of Prolonged Extubations: A Prospective and Observational Study.
Clevenger, Kaitlyn R; Dexter, Franklin; Epstein, Richard H; Sondekoppam, Rakesh; Marian, Anil A.
Afiliación
  • Clevenger KR; Anesthesia, University of Iowa, Iowa City, USA.
  • Dexter F; Anesthesia, University of Iowa, Iowa City, USA.
  • Epstein RH; Anesthesiology, University of Miami Miller School of Medicine, Miami, USA.
  • Sondekoppam R; Anesthesia, University of Iowa, Iowa City, USA.
  • Marian AA; Anesthesia, University of Iowa, Iowa City, USA.
Cureus ; 16(6): e63371, 2024 Jun.
Article en En | MEDLINE | ID: mdl-39070308
ABSTRACT

BACKGROUND:

Prolonged times to tracheal extubation (≥15 minutes from dressing on the patient) are consequential based on their clinical and economic effect. We evaluated the variability among anesthesia practitioners in their goals for the age-adjusted end-tidal minimum alveolar concentration of sevoflurane (MAC) at surgery end and achievement of their goals.

METHODS:

We prospectively studied a cohort of 56 adult patients undergoing general anesthesia with sevoflurane as the sole anesthetic agent, scheduled operating room time of at least 3 hours, and non-prone positioning. At the start of surgical closure, an observer asked the anesthesia practitioner their goal for MAC when the surgical drapes are lowered (i.e., the functional end of surgery for the studied procedures). When the drapes were lowered, the MAC achieved was recorded, and the values were compared.

RESULTS:

The standard deviation of the practitioners' MAC goal was large, 0.199 (N = 56 cases, 95% confidence interval 0.17-0.24), not significantly different from the standard deviation of the MAC achieved of 0.253, P = 0.071. The MAC goal and MAC achieved were correlated pairwise, Pearson r =0.65, P < 0.0001. There was no incremental effect of operating room conversation(s) related to case progress on the association (partial correlation ­0.01, P = 0.96). Differences among practitioners in the MAC achieved at surgery end were consequential. Specifically, for the N = 12 cases with prolonged extubation, the mean MAC was 0.60 (standard deviation 0.10) versus 0.48 (0.21) among the N = 44 cases without prolonged extubation (P = 0.0070).

CONCLUSIONS:

The standard deviation of the MAC goal among practitioners was sufficiently large to contribute significantly to the variability in the MAC achieved at the end of surgery. We confirmed prospectively that the age-adjusted end-tidal MAC at the end of surgery matters clinically and economically because differences of 0.60 versus 0.48 were associated with more prolonged extubations. Our novel finding is that the MAC achieved ≥0.60 were caused in part by the anesthesia practitioners' stated MAC goals when surgical closures started.
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Cureus Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Cureus Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos