Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52.688
Filtrar
1.
J Vis Exp ; (210)2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-39221932

RESUMO

Molecular diagnostics by Clustered Regularly Interspaced Short Palindromic Repeats (CRISPR)-based detection have high diagnostic accuracy and attributes that are suitable for use at point-of-care settings such as fast turnaround times for results, convenient simple readouts, and no requirement of complicated instruments. However, the reactions can be cumbersome to perform at the point of care due to their many components and manual handling steps. Herein, we provide a step-by-step, optimized protocol for the robust detection of disease pathogens and genetic markers with recombinase-based isothermal amplification and CRISPR-based reagents, which are premixed and then freeze-dried in easily stored and ready-to-use formats. Premixed, freeze-dried reagents can be rehydrated for immediate use and retain high amplification and detection efficiencies. We also provide a troubleshooting guide for commonly found problems upon preparing and using premixed, freeze-dried reagents for CRISPR-based diagnostics, to make the detection platform more accessible to the wider diagnostic/genetic testing communities.


Assuntos
Liofilização , Técnicas de Amplificação de Ácido Nucleico , Sistemas Automatizados de Assistência Junto ao Leito , Liofilização/métodos , Humanos , Técnicas de Amplificação de Ácido Nucleico/métodos , Repetições Palindrômicas Curtas Agrupadas e Regularmente Espaçadas/genética , Sistemas CRISPR-Cas/genética , Indicadores e Reagentes/química , Técnicas de Diagnóstico Molecular/métodos
4.
Cancer Med ; 13(16): e70128, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39177082

RESUMO

BACKGROUND: Immunofixation electrophoresis (IFE) is the standard method for confirming the presence of a monoclonal protein (M-protein) at multiple myeloma (MM) diagnosis. IFE is also essential at assessment of complete response (CR) and stringent CR during treatment. As the CR assessment is influenced by daratumumab and isatuximab, HYDRASHIFT assays were developed. METHODS: Samples from patients under treatment that included daratumumab or isatuximab were tested and monitored by IFE on the HYDRASYS system using HYDRASHIFT assays (HYDRASYS/HYDRASHIFT) and by IFE on the Epalyzer2 system (Epalyzer). RESULTS: The IFE using HYDRASYS/HYDRASHIFT avoided a false positive caused by drug-related IgG-κ and contributed to accurate assessment of CR. Furthermore, HYDRASYS/HYDRASHIFT detected small M-proteins at early relapse and detected free light chains (FLCs) in patients with renal impairment exhibiting high serum FLCs despite being often missed on Epalyzer. CONCLUSION: Sensitivity and specificity of M-protein detection vary greatly depending on the IFE system and reagents used.


Assuntos
Anticorpos Monoclonais Humanizados , Anticorpos Monoclonais , Mieloma Múltiplo , Proteínas do Mieloma , Humanos , Anticorpos Monoclonais/uso terapêutico , Mieloma Múltiplo/tratamento farmacológico , Mieloma Múltiplo/sangue , Anticorpos Monoclonais Humanizados/uso terapêutico , Proteínas do Mieloma/análise , Feminino , Idoso , Masculino , Pessoa de Meia-Idade , Imunoeletroforese/métodos , Resultado do Tratamento , Imunoglobulina G/sangue , Cadeias kappa de Imunoglobulina/sangue , Indicadores e Reagentes
5.
Org Lett ; 26(31): 6608-6613, 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39072587

RESUMO

We report a minimalist gaseous sulfonyl-chloride-derived reagent for multicomponent bioconjugation with amine, phenol, or aniline reagents to afford urea or carbamate products. With the utilization of a gas-phase reagent for a reaction mediated by metal ions, a variety of biologically relevant molecules, such as saccharide, poly(ethylene glycol), fluorophore, and affinity tag, can be efficiently cross-linked to the N terminus or lysine side-chain amines on natural polypeptides or proteins.


Assuntos
Aminas , Aminas/química , Estrutura Molecular , Gases/química , Ureia/química , Carbamatos/química , Indicadores e Reagentes/química , Peptídeos/química , Compostos de Anilina/química , Polietilenoglicóis/química
7.
BMC Res Notes ; 17(1): 199, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39026307

RESUMO

OBJECTIVE: Environmental DNA (eDNA) detection is a transformative tool for ecological surveys which in many cases offers greater accuracy and cost-effectiveness for tracking low-density, cryptic species compared to conventional methods. For the use of targeted quantitative PCR (qPCR)-based eDNA detection, protocols typically require freshly prepared reagents for each sample, necessitating systematic evaluation of reagent stability within the functional context of eDNA standard curve preparation and environmental sample evaluation. Herein, we assessed the effects of long-term storage and freeze-thaw cycles on qPCR reagents for eDNA analysis across six assays. RESULTS: Results demonstrate qPCR plates (containing pre-made PCR mix, primer-probe, and DNA template) remain stable at 4 °C for three days before thermocycling without fidelity loss irrespective of qPCR assay used. Primer-probe mixes remain stable for five months of - 20 °C storage with monthly freeze-thaw cycles also irrespective of qPCR assay used. Synthetic DNA stocks maintain consistency in standard curves and sensitivity for three months under the same conditions. These findings enhance our comprehension of qPCR reagent stability, facilitating streamlined eDNA workflows by minimizing repetitive reagent preparations.


Assuntos
DNA Ambiental , Reação em Cadeia da Polimerase em Tempo Real , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase em Tempo Real/normas , DNA Ambiental/análise , DNA Ambiental/genética , Indicadores e Reagentes , Congelamento , Primers do DNA/genética , Manejo de Espécimes/métodos
8.
Ann Hematol ; 103(8): 3219-3227, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38935318

RESUMO

INTRODUCTION: There are significant differences in the activated partial thromboplastin time (APTT) critical values reported in different studies, most of which does not make recommendations for any specific clear detection systems. The International Council for Standardization in Hematology (ICSH) recommends that APTT critical values be established based on the reagent type, coagulation factor sensitivity and heparin response. The objective of this study was to establish APTT critical values by using different reagents and based on single coagulation factor deficiencies. METHODS: The APTT values were determined in commercial endogenous coagulation factor-deficient plasma at concentrations of 1 IU/dL, 2 IU/dL, 5 IU/dL, 10 IU/dL, 20 IU/dL, and 30 IU/dL by using four assay systems. The retrospective collection of data from patients who lacked factor VIII (FVIII), FIX, or FXI alone was performed. Receiver operating characteristic (ROC) curves were constructed to assess the diagnostic accuracy of APTT for identifying patients with an endogenous coagulation factor activity < 5 IU/dL. RESULTS: The APTT values in the plasma samples with the same concentrations of endogenous coagulation factors were significantly different among the four assay systems (P < 0.001). The suggested critical values of APTT were 40.0 s for Sysmex CS5100 (Actin FSL), 58.0 s for Sysmex CS5100 (Actin), 51.8 s for STA-R Evolution (STA-PTTA), and 64.8 s for ACL TOP 700 (HemosIL SynthasIL). On the basis of the ROC curve, the optimal threshold values for APTT (STA-PTTA) were 55.8 s in patients with a simple deficiency of FVIII (sensitivity = 100%, specificity = 85.7%, area under the ROC curve (AUC) = 0.982), 54.3 s in patients with a simple deficiency of FIX (sensitivity = 100%, specificity = 92.9%, AUC = 0.986), and 71.7 s in patients with a simple deficiency of FXI (sensitivity = 100%, specificity = 94.1%, AUC = 0.992), which were closer (difference of 0.6-2.5 s) to the cutoff points for commercial plasma at equal factor levels. CONCLUSIONS: APTT critical values need to be established for different reagents based on the presence of a single coagulation factor deficiency.


Assuntos
Fatores de Coagulação Sanguínea , Humanos , Tempo de Tromboplastina Parcial , Estudos Retrospectivos , Fatores de Coagulação Sanguínea/análise , Feminino , Masculino , Transtornos de Proteínas de Coagulação/sangue , Transtornos de Proteínas de Coagulação/diagnóstico , Curva ROC , Testes de Coagulação Sanguínea/métodos , Testes de Coagulação Sanguínea/normas , Indicadores e Reagentes
9.
Bioanalysis ; 16(14): 735-745, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38884331

RESUMO

Aim: To redevelop a neutralizing antibody (NAb) assay to be much more drug tolerant, have a large dynamic range and have high inhibition when using high levels of positive control (PC).Materials & methods: Early assay data suggested that typical biotin labeling of the capture reagent (Drug 1, produced in a human cell line) was blocking it from binding with the PC or the detection target, and that the detection target was out competing the PC. Methodical biotin labeling experiments were performed at several challenge ratios and an Fc linker was added to the detection target.Results & conclusion: A larger dynamic range, high inhibition and higher drug tolerance were achieved by adding an acid dissociation step to the assay, performing atypical biotin labeling of Drug 1 and switching to a detection target that contained an Fc linker to increase steric hinderance and decrease its binding affinity to Drug 1.


Many of the drugs available today are produced by a living organism and these are called biologics. Biologics are larger than chemical drugs and the human body can detect them as foreign and create antibodies against them. This is called immunogenicity. When the antibodies created against the biologic blocks the drug's ability to work correctly, they are called neutralizing antibodies (NAbs). Testing for NAbs is one of the requirements of regulatory agencies for biologics. Here we describe challenges encountered developing an assay to test for NAbs against a biologic.


Assuntos
Anticorpos Neutralizantes , Humanos , Anticorpos Neutralizantes/imunologia , Biotina/química , Indicadores e Reagentes/química , Testes de Neutralização/métodos
10.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(3): 343-345, 2024 May 30.
Artigo em Chinês | MEDLINE | ID: mdl-38863106

RESUMO

From the perspective of the performance evaluation, concerns of the range of pathogens, establishment of enterprise reference material, reaction system study and analytical performances evaluation of central nervous system infection pathogen metagenome sequencing reagent are briefly described, including study methods and quality control requirements. This study is intended to increase the research and development efficiency of products, and contribute to the development of associated industry.


Assuntos
Infecções do Sistema Nervoso Central , Metagenoma , Infecções do Sistema Nervoso Central/microbiologia , Controle de Qualidade , Indicadores e Reagentes
11.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(3): 339-342, 2024 May 30.
Artigo em Chinês | MEDLINE | ID: mdl-38863105

RESUMO

As an important part of the Big Health Industry, in vitro diagnostic(IVD) reagents play a vital role in the prevention, diagnosis and treatment of diseases. In recent years, especially after the novel coronavirus infection, IVD industry has developed rapidly in China, but it still cannot meet the needs of clinical use. By conducting desk research, expert interview, manufacturer survey and hospital survey, this study analyzed the development status of IVD industry in Shanghai, summarized the problems encountered in the high-quality development from the aspects of raw materials, innovation ability, and clinical trials, etc., and proposed recommendations for promoting the high-quality innovation and development of IVD industry in Shanghai.


Assuntos
Indicadores e Reagentes , China , Humanos , COVID-19
12.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(3): 315-318, 2024 May 30.
Artigo em Chinês | MEDLINE | ID: mdl-38863100

RESUMO

The management of in vitro diagnostic (IVD) reagents in hospitals often faces issues such as the lack of a unified coding system, unclear consumption patterns, and unknown cost-to-income ratios. It is necessary to employ information systems to achieve comprehensive, detailed, and traceable management of IVD reagents. An information management system for IVD reagents based on unique coding is introduced, which integrates admission, acceptance, and consumption processes through unique codes. The system calculates the income per experimental item based on the consumption of IVD reagents and the charge for each experimental item. The system enhances the efficiency of the IVD reagent supply chain management and promotes detailed oversight of IVD reagent usage.


Assuntos
Indicadores e Reagentes , Sistemas de Informação Administrativa , Administração de Materiais no Hospital
13.
J Agric Food Chem ; 72(26): 14601-14609, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38900413

RESUMO

Although γ-methacryloxypropyltrimethoxysilane (MPS) was proved to be an effective reagent for improving the dimensional stability of wood, a bottleneck in ASE value (around 50%) existed. The reason was that MPS with low polarity opened few hydrogen bonds in the amorphous region of cellulose, while these hydrogen bonds could be reopened by water. Therefore, citric acid (CA) is chosen to cooperate with MPS to further enhance the dimensional stability of wood. In this paper, MPS and CA were used to modify wood individually (MW and CW) or with different combinations, that is, one-step modification (M/CW) and two-step modification with MPS first (M-CW) or CA first (C-MW). CA and MPS concentrations were optimized at 5 wt%. The ASE value for M/CW was only 25.74% at a weight percent gain (WPG) of 6.43%, which was only 0.6 times to MW or 0.7 times to CW. For M-CW, the ASE value gradually decreased with the soaking cycles, from 65.64% at a WPG of 9.05% to 51.20%. The C-MW had the best dimensional stability, with the ASE value 75.35% at a WPG of 11.50%. Although it decreased during the first soaking cycle, it stabilized at 62.20% at last. SEM and EDS images showed that the polymer mainly distributed in cell walls and few in cell lumen in C-MW. Thus, the enhanced dimensional stability of C-MW could be explained by CA opening the hydrogen bonds in the amorphous region of cellulose first, which provided more binding sites for MPS.


Assuntos
Parede Celular , Celulose , Madeira , Madeira/química , Celulose/química , Parede Celular/química , Ácido Cítrico/química , Ligação de Hidrogênio , Silanos/química , Indicadores e Reagentes/química
14.
J Forensic Sci ; 69(4): 1429-1440, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38880998

RESUMO

To establish the correlation between thermal conditions imposed on bloodstains and visualizing effect of enhancement techniques, infrared photography and four chemical enhancement reagents were used to visualize bloodstains following thermal exposure. A black tile was selected as the substrate to intensify the visualization challenge, with a Cone Calorimeter serving as the standardized heating source to control thermal conditions. Compared with standard photography, infrared photography is proven to be a valuable complement to chemical reagents, showing significant advantages in visualizing bloodstains after thermal exposure. However, it is worth noting that infrared image fell short of standard image when bloodstains displayed raised, embossed morphology or when bloodstains almost disappeared under specific conditions. The enhancement effectiveness was found to be strongly correlated with thermal conditions imposed on bloodstains, and the morphology evolution of bloodstains during heating affected the chemical enhancement effect additionally, especially when the bulge morphology was formed, and it was observed that reagents were more effective after removing the dense shell of the bulge. Among the four selected chemical enhancement reagents, fluorescein performed exceptionally well, maintaining its effectiveness even for bloodstains heated at 641°C for 10 min. TMB demonstrated its visualizing ability for bloodstains heated at 396°C for 5 min and heated at 310°C for 20 min. BLUESTAR® followed afterwards, while luminol performed worst. The correlation between thermal conditions imposed on bloodstains and the corresponding visualizing effectiveness of enhancement techniques provides important references for detecting bloodstains at fire scenes.


Assuntos
Manchas de Sangue , Temperatura Alta , Fotografação , Humanos , Raios Infravermelhos , Luminol , Fluoresceína , Indicadores e Reagentes , Calorimetria , Corantes Fluorescentes , Medicina Legal/métodos , Substâncias Luminescentes
15.
Anal Methods ; 16(24): 3810-3814, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38855885

RESUMO

A cysteine-based fluorous trapping reagent, Rf8CYS, was developed. Rf8CYS formed adducts with soft and hard electrophilic reactive metabolites. These fluorous-tagged adducts were purified via both fluorous solid-phase extraction and the direct injection method. The highly sensitive mass spectrometric detection of an unprecedented adduct of the ticlopidine metabolite was realized.


Assuntos
Cisteína , Extração em Fase Sólida , Cisteína/química , Cisteína/metabolismo , Cisteína/análise , Extração em Fase Sólida/métodos , Indicadores e Reagentes/química , Espectrometria de Massas/métodos , Humanos
16.
Talanta ; 277: 126378, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38870757

RESUMO

In our previous study, a chemical derivatization reagent named 5-(dimethylamino) naphthalene-1-sulfonyl piperazine (Dns-PP) was developed to enhance the chromatographic retention and the mass spectrometric response of free fatty acids (FFAs) in reversed-phase liquid chromatography coupled with electrospray ionization-mass spectrometry (RPLC-ESI-MS). However, Dns-PP exhibited strong preferences for long-chain FFAs, with limited improvement for short- or medium-chain FFAs. In this study, a new series of labeling reagents targeting FFAs were designed, synthesized, and evaluated. Among these reagents, Tmt-PP (N2, N2, N4, N4-tetramethyl-6-(4-(piperazin-1-ylsulfonyl) phenyl)-1,3,5-triazine-2,4-diamine) exhibited the best MS response and was selected for further evaluations. We compared Tmt-PP with Dns-PP and four commonly used carboxyl labeling reagents from existing studies, demonstrating the advantages of Tmt-PP. Further comparisons between Tmt-PP and Dns-PP in measuring FFAs from biological samples revealed that Tmt-PP labeling enhanced the MS response for about 80 % (30/38) of the measured FFAs, particularly for short- and medium-chain FFAs. Moreover, Tmt-PP labeling significantly improved the chromatographic retention of short-chain FFAs. To ensure accurate quantification, we developed a stable isotope-labeled Tmt-PP (i.e., d12-Tmt-PP) to react with chemical standards and serve as one-to-one internal standards (IS). The method was validated for accuracy, precision, sensitivity, linearity, stability, extraction efficiency, as well as matrix effect. Overall, this study introduced a new chemical derivatization reagent Tmt-PP (d12-Tmt-PP), providing a sensitive and accurate option for quantifying FFAs in biological samples.


Assuntos
Piperazinas , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Piperazinas/química , Animais , Cromatografia Líquida/métodos , Ácidos Graxos/química , Ácidos Graxos/análise , Indicadores e Reagentes/química , Sulfonas/química , Humanos , Espectrometria de Massa com Cromatografia Líquida
17.
Nature ; 631(8020): 319-327, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38898275

RESUMO

Naturally occurring (native) sugars and carbohydrates contain numerous hydroxyl groups of similar reactivity1,2. Chemists, therefore, rely typically on laborious, multi-step protecting-group strategies3 to convert these renewable feedstocks into reagents (glycosyl donors) to make glycans. The direct transformation of native sugars to complex saccharides remains a notable challenge. Here we describe a photoinduced approach to achieve site- and stereoselective chemical glycosylation from widely available native sugar building blocks, which through homolytic (one-electron) chemistry bypasses unnecessary hydroxyl group masking and manipulation. This process is reminiscent of nature in its regiocontrolled generation of a transient glycosyl donor, followed by radical-based cross-coupling with electrophiles on activation with light. Through selective anomeric functionalization of mono- and oligosaccharides, this protecting-group-free 'cap and glycosylate' approach offers straightforward access to a wide array of metabolically robust glycosyl compounds. Owing to its biocompatibility, the method was extended to the direct post-translational glycosylation of proteins.


Assuntos
Técnicas de Química Sintética , Oligossacarídeos , Açúcares , Radicais Livres/química , Radicais Livres/metabolismo , Glicosilação/efeitos da radiação , Indicadores e Reagentes/química , Luz , Oligossacarídeos/síntese química , Oligossacarídeos/química , Oligossacarídeos/metabolismo , Oligossacarídeos/efeitos da radiação , Estereoisomerismo , Açúcares/síntese química , Açúcares/química , Açúcares/metabolismo , Açúcares/efeitos da radiação
18.
Biomed Microdevices ; 26(3): 28, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38825594

RESUMO

Microfluidic-based point-of-care diagnostics offer several unique advantages over existing bioanalytical solutions, such as automation, miniaturisation, and integration of sensors to rapidly detect on-site specific biomarkers. It is important to highlight that a microfluidic POC system needs to perform a number of steps, including sample preparation, nucleic acid extraction, amplification, and detection. Each of these stages involves mixing and elution to go from sample to result. To address these complex sample preparation procedures, a vast number of different approaches have been developed to solve the problem of reagent storage and delivery. However, to date, no universal method has been proposed that can be applied as a working solution for all cases. Herein, both current self-contained (stored within the chip) and off-chip (stored in a separate device and brought together at the point of use) are reviewed, and their merits and limitations are discussed. This review focuses on reagent storage devices that could be integrated with microfluidic devices, discussing further issues or merits of these storage solutions in two different sections: direct on-chip storage and external storage with their application devices. Furthermore, the different microvalves and micropumps are considered to provide guidelines for designing appropriate integrated microfluidic point-of-care devices.


Assuntos
Dispositivos Lab-On-A-Chip , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Técnicas Analíticas Microfluídicas/instrumentação , Indicadores e Reagentes/química , Desenho de Equipamento
19.
ChemMedChem ; 19(16): e202400201, 2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-38740557

RESUMO

Deuterated drugs (heavy drugs) have recently been spotlighted as a new modality for small-molecule drugs because the pharmacokinetics of pharmaceutical drugs can be enhanced by replacing C-H bonds with more stable C-D bonds at metabolic positions. Therefore, deuteration methods for drug candidates are a hot topic in medicinal chemistry. Among them, the H/D exchange reaction (direct transformation of C-H bonds to C-D bonds) is a useful and straightforward method for creating novel deuterated target molecules, and over 20 reviews on the synthetic methods related to H/D exchange reactions have been published in recent years. Although various deuterated drug candidates undergo clinical trials, approved deuterated drugs possess CD3 groups in the same molecule. However, less diversification, except for the CD3 group, is a problem for future medicinal chemistry. Recently, we developed various deuterated alkyl (dn-alkyl) sulfonium salts based on the H/D exchange reaction of the corresponding hydrogen form using D2O as an inexpensive deuterium source to introduce CD3, CH3CD2, and ArCH2CD2 groups into drug candidates. This concept summarises recent reviews related to H/D exchange reactions and novel reagents that introduce the CD3 group, and our newly developed electrophilic dn-alkyl reagents are discussed.


Assuntos
Deutério , Descoberta de Drogas , Deutério/química , Compostos de Sulfônio/química , Sais/química , Sais/síntese química , Estrutura Molecular , Indicadores e Reagentes/química , Humanos , Medição da Troca de Deutério
20.
Top Curr Chem (Cham) ; 382(2): 15, 2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38703255

RESUMO

Aligned with the increasing importance of bioorthogonal chemistry has been an increasing demand for more potent, affordable, multifunctional, and programmable bioorthogonal reagents. More advanced synthetic chemistry techniques, including transition-metal-catalyzed cross-coupling reactions, C-H activation, photoinduced chemistry, and continuous flow chemistry, have been employed in synthesizing novel bioorthogonal reagents for universal purposes. We discuss herein recent developments regarding the synthesis of popular bioorthogonal reagents, with a focus on s-tetrazines, 1,2,4-triazines, trans-cyclooctenes, cyclooctynes, hetero-cycloheptynes, and -trans-cycloheptenes. This review aims to summarize and discuss the most representative synthetic approaches of these reagents and their derivatives that are useful in bioorthogonal chemistry. The preparation of these molecules and their derivatives utilizes both classical approaches as well as the latest organic chemistry methodologies.


Assuntos
Ciclo-Octanos , Triazinas , Triazinas/química , Triazinas/síntese química , Ciclo-Octanos/química , Ciclo-Octanos/síntese química , Alcinos/química , Alcinos/síntese química , Catálise , Indicadores e Reagentes/química , Estrutura Molecular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA