Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.441
Filtrar
1.
BMC Oral Health ; 24(1): 445, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609921

RESUMO

BACKGROUND: Considering the extensive use of bleaching agents and the occurrence of side effects such as enamel demineralization, this study aimed to assess the enamel changes of bleached teeth following the experimental application of chitosan-bioactive glass (CH-BG). METHODS: In this in vitro study, CH-BG (containing 66% BG) was synthesized and characterized by Fourier-transform infrared spectroscopy (FTIR) and X-ray diffraction (XRD). Thirty sound human premolars were bleached with 40% hydrogen peroxide, and the weight% of calcium and phosphorus elements of the buccal enamel surface was quantified before and after bleaching by scanning electron microscopy/ energy-dispersive X-ray spectroscopy (SEM, EDX). Depending on the surface treatment of the enamel surface, the specimens were divided into three groups (n = 10): control (no treatment), MI Paste (MI), and CH-BG. Then the specimens were stored in artificial saliva for 14 days. The SEM/EDX analyses were performed again on the enamel surface. Data were analyzed by one-way ANOVA and Tukey's test and a p-value of < 0.05 was considered statistically significant. RESULTS: In all groups, the weight% of calcium and phosphorus elements of enamel decreased after bleaching; this reduction was significant for phosphorus (p < 0.05) and insignificant for calcium (p > 0.05). After 14 days of remineralization, the weight% of both calcium and phosphorus elements was significantly higher compared to their bleached counterparts in both MI and CH-BG groups (p < 0.05). Following the remineralization process, the difference between MI and CH-BG groups was not significant (p > 0.05) but both had a significant difference with the control group in this regard (p < 0.05). CONCLUSIONS: The synthesized CH-BG compound showed an efficacy comparable to that of MI Paste for enamel remineralization of bleached teeth.


Assuntos
Quitosana , Clareamento Dental , Humanos , Cálcio , Quitosana/efeitos adversos , Clareamento Dental/efeitos adversos , Esmalte Dentário , Fósforo
2.
São Paulo; s.n; 20240301. 104 p.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1532259

RESUMO

A fim de conter o avanço das lesões incipientes de cárie (LMB: lesões de mancha branca) e, oportunamente, de minimizar seu aspecto estético insatisfatório, a infiltração com material resinoso fotopolimerizável de baixa viscosidade e alto coeficiente de penetração vem sendo indicada. Contudo, nem sempre se consegue mascarar as LMB por completo, talvez principalmente em dentes escurecidos. Avaliou-se, pois, in vitro, o efeito do clareamento como complementação à infiltração resinosa, na dissimulação (diferença de cor do esmalte tratado vs. adjacente) de LMB em esmalte bovino artificialmente escurecido, comparativamente ao normal. Fragmentos de 6 x 3 mm, obtidos de incisivos bovinos, foram planificados e polidos, avaliados quanto à microdureza superficial (KHN, 50 g, 10 s), e distribuídos em sete grupos (n=15): N.L, N.LI, NB.LIB, E.L, E.LI, EB.LIB e C. O esmalte dos espécimes dos grupos E foi artificialmente escurecido (100 ml de água destilada / 25 g de café solúvel, 15 dias; E: escurecido), e o daqueles dos grupos N, não (N: normal). Na metade direita (região tratada - 3 x 3 mm) de todos eles, então, determinou-se uma LMB (tampão de acetato 50 mM, 64 horas, 37 oC), que não recebeu qualquer tratamento (L: lesão nenhum tratamento), ou foi apenas infiltrada H3PO4 37% / 10 s; Icon®-Dry / 30 s; Icon®- Infiltrant / 3 min + 1 min; LI: lesão infiltrada), ou infiltrada e, como o esmalte adjacente (metade esquerda, região referência/baseline - 3 x 3 mm), submetida a clareamento/bleaching (Opalescence Boost 40%, 3x de 20 min cada; LIB: lesão infiltrada e clareada; NB e EB: esmalte adjacente normal ou escurecido clareado). O esmalte de ambas as metades dos espécimes do grupo C (C: controle) não foi submetido a nada além da planificação e do polimento. Determinou-se os valores de E00, L, a e b (fórmula CIEDE2000), considerando-se como referência/baseline, em um mesmo espécime, a superfície de esmalte adjacente (metade esquerda) àquela devidamente desmineralizada / desmineralizada e tratada (metade direita) e, como a referência, submetida, ou não, a clareamento dentário. Para o grupo controle, tal diferença foi determinada entre suas duas metades. Considerando-se como fatores experimentais a condição inicial do esmalte (em 2 níveis) e o tratamento da LMB, bem como do esmalte adjacente, quando pertinente (em 3 níveis), analisou-se estatisticamente os dados por meio de ANOVA a 2 critérios e teste de Tukey. Para comparar cada um dos grupos experimentais entre si e com o grupo C, empregou-se o teste de Kruskal-Wallis e o de Dunn para E00, L e a, e ANOVA a 1 fator e teste de Tukey para b. Em todos os casos adotou-se =0,05. Independentemente se o clareamento é realizado, ou não, a infiltração resinosa é capaz de mascarar as LMB tanto no esmalte normal, quanto no escurecido. Ora, é indiferente realizar o clareamento como complementação à infiltração resinosa na dissimulação de LMB.


Assuntos
Clareamento Dental , Cor , Estética
3.
São Paulo; s.n; 20240301. 44 p.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1537499

RESUMO

Os cistos odontogênicos são processos patológicos de origem do epitélio odontogênico que ocorrem nos ossos gnáticos. A maioria dos cistos que acometem os ossos gnáticos são originários do epitélio odontogênico. O tratamento pode ser feito através da enucleação cirúrgica, ressecção óssea, ou com o auxílio de técnicas cirúrgicas de marsupialização ou descompressão para obter a redução do tamanho do cisto como também de preservar estruturas nobres na região. O estudo seguiu as diretrizes Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) foi registrado na plataforma PROSPERO sob o número de protocolo: CRD:42021239597. Uma estratégia Population, Intervention, Comparison, Outcome, Study Design (PICOS) foi utilizada. Foram selecionados 08 artigos específicos sobre a utilização de dispositivos de descompressão para cistos odontogênicos. De um total de 181 lesões identificadas e comprovadas por exame anátomo-patológico, foram encontrados 123 queratocistos, 40 cistos dentígeros, 09 cistos radiculares, 01 cisto de origem epitelial, porém sem especificação e 08 ameloblastomas unicísticos. As principais vantagens da descompressão foram minimizar as possiblidades de danos a estruturas nobres anatômicas e objetivando uma cirurgia definitiva com menor morbidade. As principais desvantagens foram: maior tempo de tratamento e dependência da colaboração do paciente. Embora não haja uma resposta sobre qual o melhor dispositivo utilizado para descompressão, este procedimento é benéfico ao tratamento, principalmente em casos de lesões extensas. O objetivo deste trabalho foi fazer uma revisão sistemática sobre os principais tipos de dispositivos utilizados para descompressão de cistos odontogênicos e integrando os dados publicados disponíveis sobre as indicações, tipos, vantagens e desvantagens dos dispositivos utilizados na descompressão de lesões císticas odontogênicas na cavidade oral.


Assuntos
Clareamento Dental
4.
J Appl Oral Sci ; 32: e20230348, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537029

RESUMO

BACKGROUND: Repositioning guides are commonly employed in clinical studies to ensure consistent tooth color measurements. Yet, their influence on measured color remains uncertain. OBJECTIVE: This study evaluated the impact of repositioning guides' color and usage on tooth color measurement using a clinical spectrophotometer. METHODOLOGY: In total, 18 volunteers participated in this study, in which the color of their upper left central incisor and upper left canine was measured with or without repositioning guides (control). The guides were made from pink, blue, or translucent silicone, as well as an acetate-based bleaching tray. Tooth color was measured in triplicates using a clinical spectrophotometer based on the CIELAB system. The standard deviations of these readings were used to estimate reproducibility, and color differences (ΔE00) between the measurements with guides and the control were calculated. RESULTS: Repositioning guides had a minimal effect on L* values and no effect on b* values. The use of pink silicone increased a* values, whereas blue or translucent silicone reduced them. Irrespective of the evaluated tooth, the lowest ΔE00 values were observed for the translucent silicone and bleaching tray. The usage of guides only affected data variability for the L* color coordinate. CONCLUSION: Using repositioning guides can significantly impact the precision of tooth color measurement with a clinical spectrophotometer.


Assuntos
Incisivo , Clareamento Dental , Humanos , Cor , Reprodutibilidade dos Testes , Espectrofotometria , Silicones
5.
Clin Oral Investig ; 28(4): 224, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38509406

RESUMO

OBJECTIVES: To evaluate the bleaching efficacy and permeability of hydrogen peroxide (HP) in the pulp chamber of human teeth bleached with lower concentrations of carbamide peroxide gel (4%, 5% and 7% CP). MATERIALS AND METHODS: Bleaching gels with lower concentrations were formulated and a commercial standard gel, 10% CP, was used as a reference. Fifty-six human premolars were randomly divided into four groups. Applications of the bleaching gel were made for 3 h for 21 days. The bleaching efficacy was evaluated by digital spectrophotometry on 1, 7, 14 and 21 days, with analysis in the ∆Eab, ∆E00 and WID color spaces. The concentration of HP in the pulp chamber was measured in the same periods by UV-Vis spectrophotometry (µg/mL). Two-way repeated analysis of variance (ANOVA) examined bleaching efficacy and HP permeability, followed by Tukey's post-hoc test (α = 0.05). RESULTS: All groups showed significant color changes, with no statistical differences after the second and third week of bleaching (p > 0.05). The 'time' factor was statistically different (p < 0.05), increasing the bleaching efficacy throughout the treatment. The 4% CP group had lower HP levels in the pulp chamber (p < 0.05). CONCLUSIONS: The results seem promising, revealing that low concentration gels are as effective as 10% CP with the benefit of reducing the amount of HP in the pulp chamber. CLINICAL RELEVANCE: Low concentration 4% PC and 5% PC maintains bleaching efficacy, reduces the penetration of HP peroxide into the pulp chamber, and may reduce tooth sensitivity.


Assuntos
Clareadores Dentários , Clareamento Dental , Humanos , Peróxido de Carbamida , Cavidade Pulpar , Clareadores Dentários/farmacologia , Peróxido de Hidrogênio , Clareamento Dental/métodos , Ácido Hipocloroso , Géis , Ureia/farmacologia , Peróxidos/farmacologia
6.
Arch Oral Biol ; 161: 105937, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38442471

RESUMO

OBJECTIVE: To evaluate the role of induced nitric oxide synthase (iNOS) in nociception/orofacial discomfort in rats submitted to tooth whitening with hydrogen peroxide (H2O2). DESIGN: Wistar rats were divided into three groups (n = 24/group): a sham group not submitted to whitening treatment, a saline group submitted to whitening treatment, and a test group submitted to whitening treatment and blockade of iNOS with aminoguanidine 50 mg/kg/day. After 24 and 48 h, and 7 days, the animals were euthanized to collect trigeminal ganglia and maxillae to histomorphometric analysis (size of neuronal bodies and percentage of pulp area filled by vessels) and behavior/nociception (Grimace scales, scratching and biting counting, weight loss and nociception assay). ANOVA-1- or - 2-way tests were used (p < 0.05, GraphPadPrism 5.0). RESULTS: The aminoguanidine-treated group showed a reduction in nociceptive threshold in the masseteric region (p < 0.001), Grimace scale scores (p < 0.001), number of scratching (p = 0.011) and body mass loss (p = 0.007). After 24 and 48 h of tooth bleaching, the saline group showed a significant increase in the mean area of the blood vessels (p = 0.020) and iNOS immunostaining in odontoblasts (p = 0.002) and non-odontoblasts cells (p = 0.025). Aminoguanidine reversed both increases. Tooth bleaching reduced the mean area of neuronal bodies, and aminoguanidine significantly reversed it (p = 0.019), but an increase in GFAP immunostaining in neuronal bodies did not reduce after seven-days or after aminoguanidine treatment (p = 0.003). CONCLUSION: iNOS blockage by aminoguanidine plays an important role in nociception and orofacial discomfort by control of inflammation in dental pulp after tooth bleaching with hydrogen peroxide (H2O2) 35%.


Assuntos
Guanidinas , Clareadores Dentários , Clareamento Dental , Ratos , Animais , Peróxido de Hidrogênio/farmacologia , Nociceptividade , Óxido Nítrico , Ratos Wistar , Óxido Nítrico Sintase
7.
Clin Oral Investig ; 28(3): 189, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38430338

RESUMO

OBJECTIVES: To assess color change efficacy and the adverse effects of varied over-the-counter (OTC) bleaching protocols. METHODOLOGY: The study included randomized clinical trials evaluating color changes from OTC bleaching agents. Nine databases were searched, including the partial capture of the grey literature. The RoB2 tool analyzed the individual risk of bias in the studies. Frequentist network meta-analyses compared treatments through common comparators (∆Eab* and ∆SGU color changes, and tooth sensitivity), integrating direct and indirect estimates and using the mean and risk differences as effect measures with respective 95% confidence intervals. The GRADE approach assessed the certainty of the evidence. RESULTS: Overall, 37 remaining studies constituted the qualitative analysis, and ten composed the meta-analyses. The total sample included 1,932 individuals. ∆Eab* was significantly higher in groups 6% hydrogen peroxide (HP) strips (≥ 14 h). ∆SGU was significantly higher in groups at-home 10% carbamide peroxide (CP) (≥ 14 h), followed by 6% HP strips (≥ 14 h) and 3% HP strips (≥ 14 h). At-home 10% CP (7-13 h) and placebo showed lower risks of tooth sensitivity without significant differences between these treatments. CONCLUSION: Considering the low level of evidence, OTC products presented satisfactory short-term effects on tooth bleaching compared to the placebo, with little to no impact on dentin hypersensitivity and gingival irritation. CLINICAL RELEVANCE: OTC products are proving to be practical alternatives for tooth whitening. However, patients should be advised about the possible risks of carrying out such procedures without professional supervision.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Humanos , Peróxido de Carbamida , Cor , Sensibilidade da Dentina/tratamento farmacológico , Peróxido de Hidrogênio , Ácido Hipocloroso , Metanálise em Rede , Medicamentos sem Prescrição/efeitos adversos , Peróxidos , Clareamento Dental/efeitos adversos , Clareamento Dental/métodos , Clareadores Dentários/efeitos adversos , Clareadores Dentários/farmacologia , Ureia
8.
J Dent ; 143: 104902, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38432352

RESUMO

OBJECTIVE: To investigate the effect of tooth whitening on biomechanical properties of vacuum-formed retainers (VFRs). METHODS: Using a split-mouth, randomised controlled trial design, thirty participants were randomly allocated to receive whitening on either the upper or the lower arch, using 10 % carbamide peroxide for two weeks. Biomechanical properties such as hardness, tensile strength, and surface roughness were assessed two weeks after whitening was completed. RESULTS: Tensile strength of the whitening arch (mean ± SD: 40.93 ± 3.96 MPa) was significantly lower than that of the control (47.40 ± 5.03 MPa) (difference 6.47 MPa, 95 % CI 4.51 - 8.42, p < 0.001). Hardness and internal roughness of the whitening arch (VHN = 14.63 ± 2.29 N/mm2 and Ra = 1.33 ± 0.35 µm, respectively) were significantly greater than those of the control (12.22 ± 1.86 N/mm2 and 0.96 ± 0.29 µm, respectively) (differences 2.41 N/mm2, 95 % CI 1.56 - 3.25, p < 0.001 and 0.37 µm, 95 % CI 0.23 - 0.51, p < 0.001, respectively). The whitening arch showed greater tooth colour change (ΔE = 6.00 ± 3.32) than the control (ΔE = 2.50 ± 1.70) (difference = 3.50, 95 % CI 2.43 - 4.56, p < 0.001). CONCLUSIONS: Based on this short-term study, marked tooth colour change was achieved by whitening with VFRs as the whitening trays, but this changed the VFRs' biomechanical properties, including a decrease in tensile strength and an increase in hardness and internal roughness. CLINICAL SIGNIFICANCE: The application of carbamide peroxide in VFRs may compromise their mechanical properties.


Assuntos
Clareadores Dentários , Clareamento Dental , Dente , Humanos , Peróxido de Carbamida , Vácuo , Clareadores Dentários/farmacologia , Ureia , Peróxidos/farmacologia , Peróxido de Hidrogênio/farmacologia , Combinação de Medicamentos
9.
J Contemp Dent Pract ; 25(1): 68-71, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38514434

RESUMO

AIM: The aim of the present study was to assess the stain removal ability and color stability of three distinct dentifrices on artificially stained enamel surface. MATERIALS AND METHODS: This study included 75 intact, healthy premolars free of dental caries that were extracted during orthodontic therapy. The samples were allowed to dry for 6 hours after being submerged in the prepared tea solution for roughly 18 hours every day. Then this procedure was repeated for seven successive days. All samples were randomly divided into three experimental groups with 25 samples in each group. Group I: control dentifrice, group II: dentifrice containing hydrogen peroxide, group III: dentifrice containing papain and bromelain. A specially designed toothbrushing simulator was used to brush every sample in the relevant group. Using a spectrophotometer and a measurement program, color measurement was evaluated after staining process after 4 weeks and 8 weeks of teeth cleaning. Using a profilometer, the surface roughness values (Ra) were assessed. RESULTS: After 8 weeks of brushing of stained samples, the color stability was better in dentifrice containing hydrogen peroxide (1.14 ± 0.11) followed by dentifrice containing papain and bromelain (1.22 ± 0.08) and control group (1.30 ± 0.09). And after 8 weeks of brushing of stained samples, the surface roughness was more in dentifrice containing hydrogen peroxide (0.237 ± 0.02) followed by dentifrice containing papain and bromelain (0.229 ± 0.13) and control group (0.207 ± 0.05). CONCLUSION: The present study concluded that the dentifrice containing hydrogen peroxide showed a superior whitening effect on the stained enamel surface than dentifrice containing papain and bromelain and control dentifrice. CLINICAL SIGNIFICANCE: The development of various dentifrice products has been greatly aided by the increased demand for an improved esthetic appearance. Teeth's natural color and any external stains that could accumulate on the tooth surface combine to determine a tooth's color. Additionally, the use of whitening dental pastes to remove external stains has grown in favor. With the development of these whitening toothpastes, dentifrices' ability to lessen or eliminate extrinsic dental stains has increased. How to cite this article: Mishra D, Kamath DG, Alagla M, et al. Evaluation of Stain Removal Efficacy and Color Stability of Three Different Dentifrices on Artificially Stained Enamel Surface-An In Vitro Study. J Contemp Dent Pract 2024;25(1):68-71.


Assuntos
Cárie Dentária , Dentifrícios , Clareamento Dental , Descoloração de Dente , Humanos , Dentifrícios/uso terapêutico , Bromelaínas/uso terapêutico , Peróxido de Hidrogênio/uso terapêutico , Corantes , Descoloração de Dente/tratamento farmacológico , Papaína/uso terapêutico , Cárie Dentária/tratamento farmacológico , Escovação Dentária , Esmalte Dentário
10.
J Appl Oral Sci ; 32: e20230416, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38536995

RESUMO

BACKGROUND: At low concentrations used for in-office bleaching gels, such as 6% HP, gingival barrier continues to be performed. If we take into account that, in the at-home bleaching technique, no barrier is indicated, it seems that the use of a gingival barrier fails to make much sense when bleaching gel in low concentration is used for in-office bleaching. OBJECTIVE: This double-blind, split-mouth, randomized clinical trial evaluated the gingival irritation (GI) of in-office bleaching using 6% hydrogen peroxide (HP) with and without a gingival barrier in adolescents, as well as color change and the impact of oral condition on quality of life. METHODOLOGY: Overall, 60 participants were randomized into which side would or would not receive the gingival barrier. In-office bleaching was performed for 50 minutes with 6% HP in three sessions. The absolute risk and intensity of GI were assessed with a visual analogue scale. Color change was assessed using a digital spectrophotometer and color guides. The impact of oral condition on quality of life was assessed using the Brazilian version of the Oral Health Impact Profile (α=0.05). RESULTS: The proportion of patients who presented GI for the "with barrier" group was 31.6% and for the "without barrier" group, 30% (p=1.0). There is an equivalence for the evaluated groups regarding GI intensity (p<0.01). Color change was detected with no statistical differences (p>0.29). There was a significant impact of oral condition on quality of life after bleaching (p<0.001). CONCLUSIONS: The use or not of the gingival barrier for in-office bleaching with 6% HP was equivalent for GI, as well as for bleaching efficacy, with improvement in the impact of oral condition on quality of life.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Humanos , Adolescente , Peróxido de Hidrogênio , Clareamento Dental/efeitos adversos , Clareamento Dental/métodos , Clareadores Dentários/efeitos adversos , Qualidade de Vida , Resultado do Tratamento , Sensibilidade da Dentina/induzido quimicamente , Géis
11.
J Mech Behav Biomed Mater ; 153: 106497, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38458078

RESUMO

OBJECTIVE: To evaluate whether coating enamel with a polymeric primer (PPol) containing titanium tetrafluoride (TiF4) before applying a bleaching gel with 35% H2O2 (35% BG) increases esthetic efficacy, prevents changes in morphology and hardness of enamel, as well as reduces the cytotoxicity from conventional in-office bleaching. MATERIALS AND METHODS: Standardized enamel/dentin discs were stained and bleached for 45 min (one session) with 35% BG. Groups 2TiF4, 6TiF4, and 10TiF4 received the gel on the enamel previously coated with PPol containing 2 mg/mL, 6 mg/mL, or 10 mg/mL, respectively. No treatment or application of 35% BG directly on enamel were used as negative control (NC), and positive control (PC), respectively. UV-reflectance spectrophotometry (CIE L*a*b* system, ΔE00, and ΔWI, n = 8) determined the bleaching efficacy of treatments. Enamel microhardness (Knoop, n = 8), morphology, and composition (SEM/EDS, n = 4) were also evaluated. Enamel/dentin discs adapted to artificial pulp chambers (n = 8) were used for trans-amelodentinal cytotoxicity tests. Following the treatments, the extracts (culture medium + bleaching gel components diffused through the discs) were collected and applied to odontoblast-like MDPC-23 cells, which were assessed concerning their viability (alamarBlue, n = 8; Live/Dead, n = 4), oxidative stress (n = 8), and morphology (SEM). The amount of H2O2 in the extracts was also determined (leuco crystal violet/peroxidase, n = 8). The numerical data underwent one-criterion variance analysis (one-way ANOVA), followed by Tukey's test, at a 5% significance level. RESULTS: Regarding the ΔE00, no difference was observed among groups 2TiF4, 6TiF4, and PC (p > 0.05). The ΔWI was similar between groups 2TiF4 and PC (p > 0.05). The ΔWI of group 6TiF4 was superior to PC (p < 0.05), and group 10TiF4 achieved the highest ΔE00 and ΔWI values (p < 0.05). Besides limiting enamel microstructural changes compared to PC, group 10TiF4 significantly increased the hardness of this mineralized dental tissue. The highest cellular viability occurred in 10TiF4 compared to the other bleached groups (p < 0.05). Trans-amelodentinal H2O2 diffusion decreased in groups 2TiF4, 6TiF4, and 10TiF4 in comparison with PC (p < 0.05). CONCLUSION: Coating enamel with a PPol containing TiF4 before applying a 35% BG may increase enamel microhardness and esthetic efficacy and reduce the trans-amelodentinal cytotoxicity of conventional in-office tooth bleaching. The PPol containing 10 mg/mL of TiF4 promoted the best outcomes.


Assuntos
Clareadores Dentários , Clareamento Dental , Peróxido de Hidrogênio/química , Clareadores Dentários/farmacologia , Dentina , Clareamento Dental/efeitos adversos , Esmalte Dentário
12.
Am J Dent ; 37(1): 3-8, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38458975

RESUMO

PURPOSE: To evaluate the effectiveness of whitening toothpaste in restoring tooth color after coffee staining and its potential impact on enamel surfaces compared with regular toothpaste. METHODS: Bovine tooth enamel specimens were prepared and stained with coffee solutions before undergoing brushing simulation with different toothpaste slurries (whitening, regular, reference). For precise evaluation, spectrophotometric measurements were taken at intervals to assess color changes using the CIELAB (Commission Internationale de l'Éclairage Lab*) color space. Additionally, profilometric measurements were taken to determine the impact of toothpaste type on the roughness and abraded depth of the enamel surface. To understand the effects of toothpaste and brushing on color change, surface roughness, and abraded depth, while also considering correlations between these factors, the findings were analyzed using mixed-effects models. RESULTS: The whitening toothpaste group demonstrated the highest recovery rate (71%) after 10,000 brushstrokes, followed by the regular toothpaste group (48%) and the reference slurry group (43%). The mixed-effects model analysis revealed that the reference group had a smaller change in lightness (ΔL) than those in the regular toothpaste group. The whitening toothpaste group showed a greater change in lightness on average than those in the regular toothpaste group, with an increase in lightness as the number of brushstrokes increased. According to the roughness and abraded depth data, the whitening toothpaste group was least affected by brushing, while the reference and regular toothpaste groups showed higher levels of roughness and abraded depth at all intervals. CLINICAL SIGNIFICANCE: Gaining a thorough understanding of the effectiveness of whitening toothpaste and its impact on the enamel surface plays a crucial role in refining toothpaste formulations and advancing tooth whitening techniques in dental care.


Assuntos
Clareamento Dental , Descoloração de Dente , Animais , Bovinos , Humanos , Cremes Dentais/uso terapêutico , Cremes Dentais/farmacologia , Café , Esmalte Dentário , Descoloração de Dente/tratamento farmacológico , Descoloração de Dente/prevenção & controle , Clareamento Dental/métodos , Escovação Dentária , Assistência Odontológica , Cor
13.
J Dent ; 142: 104875, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38309571

RESUMO

OBJECTIVE: The application of anti-inflammatories as topical desensitizers before dental bleaching is an approach to reduce bleaching-induced tooth sensitivity (TS). This randomized controlled trial compared the risk and intensity of TS and the color change resulting from in-office dental bleaching after using an experimental desensitizing gel containing ibuprofen and arginine. METHODS: Sixty-two participants with upper canine shades A2 or darker were randomly assigned to either the ibuprofen-arginine desensitizing group or the placebo group. The desensitizing gel was applied for 15 min before in-office bleaching with 35 % hydrogen peroxide gel for 50 min (2 sessions). To assess the absolute risk and intensity of TS, visual (0-10) and numeric rating (0-5) scales were used, and group comparisons were made using the McNemar test, Wilcoxon test, and paired Student t-test (α = 0.05). Color change was evaluated using Vita Classical, Vita Bleachedguide (ΔSGU), and Vita EasyShade (ΔEab, ΔE00, and ΔWID) before and one month after the bleaching procedure. Group comparisons for color change were done using a paired t-test (α = 0.05). RESULTS: The odds ratio for TS was 0.14 [95 % CI 0.02 to 0.6], meaning lower odds of TS for the desensitizing gel. A lower intensity of TS was also observed for the experimental group (p < 0.005) up to 48 h after bleaching. All color evaluation tools demonstrated effective and similar whitening for both groups (p > 0.05). CONCLUSIONS: Using the experimental desensitizing gel containing ibuprofen and arginine effectively reduced the risk and intensity of TS without compromising the bleaching efficacy. CLINICAL RELEVANCE: The topical application of ibuprofen/arginine on the in-office bleaching reduced risk and intensity of bleaching-induced tooth sensitivity.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Humanos , Sensibilidade da Dentina/induzido quimicamente , Sensibilidade da Dentina/prevenção & controle , Clareadores Dentários/efeitos adversos , Ibuprofeno/uso terapêutico , Clareamento Dental/efeitos adversos , Clareamento Dental/métodos , Peróxido de Hidrogênio/efeitos adversos , Compostos de Sódio , Arginina/uso terapêutico , Resultado do Tratamento
14.
Stomatologiia (Mosk) ; 103(1): 16-22, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38372602

RESUMO

THE AIM OF THE STUDY: Optimization of methods for treating dental discoloration using whitening systems based on hydrogen peroxide by laboratory studying their chemical properties. MATERIAL AND METHODS: The effectiveness of the bleaching system was assessed by quantitatively assessing the color change of model samples of hydroxyapatite (HAP) in the CIE L*a*b* system on a Spectron-M color analyzer after exposure to coloring food media. Safety assessment was carried out on samples made from teeth removed according to indications. RESULTS: The results of laboratory tests allow us to conclude that the Chairside Light Whitening System professional teeth whitening system fläsh. (WHITEsmile GmbH, Germany) has high whitening efficiency with a whitening degree of ~84%, which significantly exceeds the norm of GOST R 702.3.004-2021. the microhardness of the enamel of samples exposed to the whitening gel for 15 minutes changes extremely little. After exposure of the studied samples to the Chairside Light Whitening System fläsh whitening system for 45 minutes, an increase in digital microhardness indicators is observed, which indicates the dynamics of processes demineralizing the hard tooth structure. CONCLUSIONS: Chairside Light Whitening System fläsh professional teeth whitening system has high whitening efficiency with minimal impact on the teeth structure and high safety.


Assuntos
Clareadores Dentários , Clareamento Dental , Dente , Humanos , Clareamento Dental/efeitos adversos , Peróxido de Hidrogênio , Esmalte Dentário
15.
Clin Oral Investig ; 28(3): 171, 2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38400920

RESUMO

OBJECTIVES: This study aims to assess hydrogen peroxide (HP) penetration within the pulp chamber, color change (CC), physical-chemical properties, and temperature using in-office different concentration bleaching gels with or without violet light. MATERIALS AND METHODS: Fifty teeth were divided into five groups (n = 10) based on the HP concentration bleaching gels used (6% and 35%) and the used violet light (with or without). HP penetration within the pulp chamber was measured using UV-Vis. The CC was evaluated with a digital spectrophotometer. Initial and final concentration, and pH were measured through titration, and a Digital pHmeter, respectively. Temperature analyses were measured through a thermocouple. Statistical analysis included two-way ANOVA, Tukey's, and Dunnett's test (α = 0.05). RESULTS: The presence of violet light did not affect the amount of HP within the pulp chamber, or the CC (p > 0.05). Greater penetration of HP was observed within the pulp chamber, as well as CC when using 35% HP (p < 0.05). The final concentration of both gels was lower than the initial concentration, regardless of the use of violet light (p < 0.05). The initial and final pH levels remained neutral and stable (p > 0.05). The pulp temperature increased when the gels were used in conjunction with violet light (p < 0.05). CONCLUSIONS: Using violet light in conjunction with 6% or 35% HP does not alter the physical properties of the bleaching agents, the penetration of HP or enhance color change. However, an increase in temperature was observed when violet light was applied associated with bleaching gels. CLINICAL RELEVANCE: While the simultaneous use of violet light with hydrogen peroxide 6% or 35% does not alter the material's properties, it also does not bring benefits in reducing hydrogen peroxide penetration and improving color change. Furthermore, the use of violet light increases pulp temperature.


Assuntos
Clareadores Dentários , Clareamento Dental , Peróxido de Hidrogênio , Peróxidos , Ácido Hipocloroso , Géis
16.
J Dent ; 143: 104877, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38316199

RESUMO

OBJECTIVE: This randomized controlled clinical trial evaluated the whitening efficacy, tooth sensitivity (TS), and volunteers' satisfaction following the use of activated charcoal powder and toothpaste. METHODS: Fifty-six volunteers were randomly allocated into 4 groups (n = 14) according to a 14-day toothbrushing or whitening treatment with activated charcoal powder (ACPW), activated charcoal toothpaste (ACT), regular fluoridated toothpaste (RT), and 10 % carbamide peroxide (CP). Objective (ΔE00) and subjective (ΔSGU) color and whiteness index (ΔWID) changes were calculated. Patients self-reported the risk and intensity of TS using a visual analogue scale and the volunteer's satisfaction was determined by a questionnaire. Color assessments were analyzed by Kruskal-Wallis followed by Dwas-Steel-Crithlow-Fligner, and absolute TS risk and volunteer's satisfaction by Fisher exact test (p < 0.05). RESULTS: ACPW and ACT promoted similar effects in ΔE00, ΔSGU, and ΔWID to that observed for RT. No significant difference was found in terms of TS risk intensity. TS risk became high after 7 and 14 days, with higher TS prevalence in CP. Volunteers reported that ACPW exhibited the lowest ease-of-use, comfort, and whitening satisfaction among groups (p < 0.05). CONCLUSION: Activated charcoal-based products presented a minor and unsatisfactory whitening effect while CP resulted in optimal tooth whitening and the highest level of satisfaction among volunteers. Risk was higher from 7 days onwards and was more pronounced in the CP. CLINICAL RELEVANCE: Based on the whitening effect and patient satisfaction, this controlled-randomized clinical evidence supports that the use of activated charcoal-based products should be discouraged.


Assuntos
Sensibilidade da Dentina , Clareamento Dental , Humanos , Peróxido de Hidrogênio/uso terapêutico , Carvão Vegetal/uso terapêutico , Cremes Dentais/uso terapêutico , Pós , Método Simples-Cego , Clareamento Dental/métodos , Peróxido de Carbamida , Sensibilidade da Dentina/tratamento farmacológico
17.
J Dent ; 143: 104880, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38336019

RESUMO

OBJECTIVE: To evaluate the influence of antioxidants (ATX) resveratrol, winter's bark, green tea and yerba mate on the bond strength between bleached enamel and the nanohybrid composite resin. METHODOLOGY: Bovine incisor crowns (n = 132) were randomly divided into 22 groups (n = 6) according to the application times (5, 10, 15, 30, and 60 min) of each antioxidant. Teeth restored without previous bleaching or ATX constituted the non-bleached control group (NB Ctrl) (n = 6), and teeth restored after bleaching and without ATX represented the bleached control group (B Ctrl) (n = 6). The 35 % hydrogen peroxide was applied for 45 min (3 application of 15 min) to the buccal enamel surface. ATX was used after bleaching for the specified time of each group and removed with air-water spray. The enamel was etched with 37 % phosphoric acid (30 s) and rinsed with air-water spray. The adhesive resin was applied to the enamel dry surface. Teeth were restored using 1 mm composite resin increments (10 × 10 × 3 mm) and sectioned in test specimens of 6 mm in length and 1 mm2 in cross-sectional area submitted to microtensile bond strength test (0.5 mm/min). The load (N) at failure was recorded, and the bond strength (σt) was calculated (MPa). The fracture area was analyzed under optical microscopy, and failures were classified as cohesive, mixed, or adhesive. Data was evaluated by Kruskal-Wallis and Dunn tests (p ≤ 0.05). RESULTS: B Ctrl group presented lower σt than NB Ctrl (p < 0.001). Applying resveratrol for 5 or 10 min, winter's bark for 10 or 15 min, green tea for less than 15 min, and yerba mate for 15 min provided similar σt between bleached enamel and nanohybrid composite to the control group. CONCLUSION: Restorative procedures performed immediately after tooth bleaching compromises adhesion. Experimental antioxidants applied to bleached enamel can increase the immediate bond strength of restorations performed directly after bleaching, with similar values to those observed in unbleached enamel. CLINICAL SIGNIFICANCE: This study presents promising results to support the use of antioxidants on the recently bleached enamel to allow adhesive tooth restorations. The immediate bonding obtained using antioxidants was similar to the one achieved in non-bleached enamel in brief application times. Green tea extract and resveratrol were able to restore the bond strength to bleached enamel in a short application time of 5 min. The reduction in the required application time holds the potential to decrease the overall duration of the clinical section, offering clinical advantages and improving the feasibility of using antioxidants on the bleached enamel prior to adhesive procedures.


Assuntos
Anti-Infecciosos , Colagem Dentária , Clareamento Dental , Animais , Bovinos , Antioxidantes/farmacologia , Antioxidantes/química , Resveratrol/farmacologia , Colagem Dentária/métodos , Cimentos Dentários/farmacologia , Cimentos Dentários/química , Clareamento Dental/métodos , Resinas Compostas/farmacologia , Resinas Compostas/química , Esmalte Dentário , Anti-Infecciosos/farmacologia , Chá , Água , Resistência ao Cisalhamento
18.
Oper Dent ; 49(2): 157-165, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38349817

RESUMO

OBJECTIVES: To evaluate the volume and depth of enamel loss promoted by 37.5% and 7.5% hydrogen peroxide (HP) gels, and quantify the loss of calcium (Ca) and phosphate (P) ions by using ion chromatography (IC) analysis after bleaching. METHODS: Sixty bovine enamel specimens were randomly divided into three groups: Control - no bleaching gel; HP37.5%, application of HP 37.5% for 45 minutes for 14 days; and HP7.5%, application of HP 7.5% for 3 applications of 8 minutes. The surface analysis (n=5) was performed using a scanning electron microscope (SEM) and dispersive energy system (EDS) to calcium and phosphorus dosage. The micro-CT was used for the enamel loss analysis (n=5). IC was used to analyze extracted Ca and P (n=10). Data were analyzed by one-way ANOVA and two-way repeated measures ANOVA, followed by Tukey and Dunnett's tests (α=0.05). RESULTS: Significantly higher volume and depth of enamel loss were found for bleached groups compared with the control group. HP7.5% had significantly higher enamel change than HP37.5%. SEM showed higher enamel porosity for HP37.5% and HP7.5% compared to control. The IC demonstrated a significant increase of Ca incorporated into the gel, however, only HP7.5% had a higher P presence than the control group. The HP7.5% showed higher Ca and P ion exchange than HP37.5% (p<0.001). CONCLUSION: HP37.5% and HP7.5%, caused enamel mineral changes compared with the control group. The IC method was demonstrated to be an effective methodology for detecting enamel mineral loss by the bleaching gel.


Assuntos
Clareadores Dentários , Clareamento Dental , Animais , Bovinos , Cálcio , Clareamento Dental/métodos , Esmalte Dentário , Microtomografia por Raio-X , Peróxido de Hidrogênio/química , Minerais , Fosfatos , Géis
19.
J Esthet Restor Dent ; 36(3): 437-444, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38303586

RESUMO

OBJECTIVE: This study aimed to investigate the relationship between patient satisfaction of outcomes and tooth color changes during and after tooth bleaching. METHODS: In this clinical trial, 63 volunteers participated in an in-office bleaching procedure using a 40% hydrogen peroxide gel. The treatment consisted of two sessions, each comprising two 30-min applications of the bleaching gel. The L*, a*, and b* values of six maxillary anterior teeth were measured at baseline (T1), after the first bleaching session (T2), after the second bleaching session (T3), 1 week after the second in-office bleaching session (T4), and 3 weeks after the second in-office bleaching session (T5). The color differences (ΔE00 ) were calculated using CIEDE2000. A satisfaction scale with a score ranging from 0 to 3 was used to record participants' level of satisfaction with their tooth color at each time point. The data were statistically analyzed using repeated measures analysis of variance and logistic regression (α = 0.05). RESULTS: Significant correlations were observed between ΔL*, Δb*, and ΔE00 values at T3 and patient satisfaction (all p < 0.05). The regression model indicated a more pronounced impact of Δb* on patient satisfaction compared to ΔL*. The established regression models were as follows: Logit (PL*b* ) = -4.354 + 0.271ΔL* - 0.585Δb* and Logit (PΔE00 ) = -2.552 + 0.521ΔE00 . The findings suggested a minimum ΔE00 value of 4.90 for satisfactory results. A minimum ΔE00 value of 3.9, 5.0, and 6.8 was necessary for central incisors, lateral incisors, and canines, respectively, to achieve a satisfactory result. CONCLUSIONS: The ΔL*, Δb*, and ΔE00 values were found to be significantly correlated with patient satisfaction after bleaching. Δb* was identified as having a greater influence on patient satisfaction than ΔL* values in the regression model. Furthermore, attaining a minimum ΔE00 value of 4.90 is necessary to achieve satisfactory outcomes. A greater ΔE00 value is needed for canines than for incisors to achieve equivalent patient satisfaction. CLINICAL SIGNIFICANCE: This study emphasizes the importance of considering the extent of color change needed to achieve patient satisfaction after tooth bleaching procedures.


Assuntos
Clareadores Dentários , Clareamento Dental , Dente , Humanos , Cor , Peróxido de Hidrogênio , Incisivo , Satisfação do Paciente , Clareamento Dental/métodos
20.
J Appl Oral Sci ; 32: e20230336, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38324805

RESUMO

OBJECTIVES: This study aimed to analyze the cost-effectiveness of whitening toothpastes and at-home bleaching for the treatment of tooth discoloration. METHODOLOGY: A cost-effectiveness economic analysis was conducted, and eight randomized clinical trials were selected based on the whitening agent product used: blue covarine dentifrices (BCD), hydrogen peroxide dentifrices (HPD), dentifrices without bleaching agents (CD, negative control), and 10% carbamide peroxide (CP10, positive control) for at-home bleaching. The consumer/patient perspective was adopted, macro-costing techniques were used and a decision tree model was performed considering the costs in the American and Brazilian markets. The color change evaluation (ΔE*ab) was used to calculate the effectiveness of tooth bleaching. A probabilistic analysis was performed using a Monte Carlo simulation and incremental cost-effectiveness ratios were obtained. RESULTS: CP10 resulted in the highest cost-effectiveness compared to the use of dentifrices in both markets. In Brazil, HPD was more cost-effective than BCD and CD. In the US, the increased costs of HPD and BCD did not generate any whitening benefit compared to CD. CONCLUSIONS: CP10 was more cost-effective than BCD and HPD for tooth bleaching from the perspectives of the Brazilian and American markets. Decision-making should consider the use of CP10 for treating tooth discoloration.


Assuntos
Clareadores Dentários , Clareamento Dental , Descoloração de Dente , Humanos , Cor , Análise de Custo-Efetividade , Dentifrícios/uso terapêutico , Peróxido de Hidrogênio/uso terapêutico , Clareamento Dental/métodos , Clareadores Dentários/uso terapêutico , Descoloração de Dente/tratamento farmacológico , Cremes Dentais/uso terapêutico , Ureia , Ensaios Clínicos Controlados Aleatórios como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...