Med Phys ; 50(1): 142-151, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36183146

RESUMEN

BACKGROUND: Eye plaque brachytherapy is currently an optimal therapy for intraocular cancers. Due to the lack of an effective and practical technique to measure the seed radioactivity distribution, current quality assurance (QA) practice according to the American Association of Physicists in Medicine TG129 only stipulates that the plaque assembly be visually inspected. Consequently, uniform seed activity is routinely adopted to avoid possible loading mistakes of differential seed loading. However, modulated dose delivery, which represents a general trend in radiotherapy to provide more personalized treatment for a given tumor and patient, requires differential activities in the loaded seeds. PURPOSE: In this study, a fast and low-cost radio-luminescent imaging and dose calculating system to verify the seed activity distribution for differential loading was developed. METHODS: A proof-of-concept system consisting of a thin scintillator sheet coupled to a camera/lens system was constructed. A seed-loaded plaque can be placed directly on the scintillator surface with the radioactive seeds facing the scintillator. The camera system collects the radioluminescent signal generated by the scintillator on its opposite side. The predicted dose distribution in the scintillator's sensitive layer was calculated using a Monte Carlo simulation with the planned plaque loading pattern of I-125 seeds. Quantitative comparisons of the distribution of relative measured signal intensity and that of the relative predicted dose in the sensitive layer were performed by gamma analysis, similar to intensity-modulated radiation therapy QA. RESULTS: Data analyses showed high gamma (3%/0.3 mm, global, 20% threshold) passing rates for correct seed loadings and low passing rates with distinguished high gamma value area for incorrect loadings, indicating that possible errors may be detected. The measurement and analysis only required a few extra minutes, significantly shorter than the time to assay the extra verification seeds the physicist already must perform as recommended by TG129. CONCLUSIONS: Radio-luminescent QA can be used to facilitate and assure the implementation of intensity-modulated, customized plaque loading.


Asunto(s)
Braquiterapia , Neoplasias del Ojo , Humanos , Radioisótopos de Yodo/uso terapéutico , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Braquiterapia/métodos , Método de Montecarlo , Neoplasias del Ojo/radioterapia , Radiometría/métodos
2.
Radiother Oncol ; 176: 239-243, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35964762

RESUMEN

The rapid depletion of oxygen during irradiation at ultra-high dose rate calls for tissue oximeters capable of high temporal resolution. This study demonstrates a water-soluble phosphorescent nanoprobe and fiber-coupled instrument, which together are used to measure the kinetics of oxygen depletion at 200 Hz during irradiation of in vitro solutions.


Asunto(s)
Oximetría , Oxígeno , Humanos , Dosificación Radioterapéutica , Radioterapia
3.
Int J Radiat Oncol Biol Phys ; 111(1): 240-248, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-33845146

RESUMEN

PURPOSE: Delivery of radiation at ultrahigh dose rates (UHDRs), known as FLASH, has recently been shown to preferentially spare normal tissues from radiation damage compared with tumor tissues. However, the underlying mechanism of this phenomenon remains unknown, with one of the most widely considered hypotheses being that the effect is related to substantial oxygen depletion upon FLASH, thereby altering the radiochemical damage during irradiation, leading to different radiation responses of normal and tumor cells. Testing of this hypothesis would be advanced by direct measurement of tissue oxygen in vivo during and after FLASH irradiation. METHODS AND MATERIALS: Oxygen measurements were performed in vitro and in vivo using the phosphorescence quenching method and a water-soluble molecular probe Oxyphor 2P. The changes in oxygen per unit dose (G-values) were quantified in response to irradiation by 10 MeV electron beam at either UHDR reaching 300 Gy/s or conventional radiation therapy dose rates of 0.1 Gy/s. RESULTS: In vitro experiments with 5% bovine serum albumin solutions at 23°C resulted in G-values for oxygen consumption of 0.19 to 0.21 mm Hg/Gy (0.34-0.37 µM/Gy) for conventional irradiation and 0.16 to 0.17 mm Hg/Gy (0.28-0.30 µM/Gy) for UHDR irradiation. In vivo, the total decrease in oxygen after a single fraction of 20 Gy FLASH irradiation was 2.3 ± 0.3 mm Hg in normal tissue and 1.0 ± 0.2 mm Hg in tumor tissue (P < .00001), whereas no decrease in oxygen was observed from a single fraction of 20 Gy applied in conventional mode. CONCLUSIONS: Our observations suggest that oxygen depletion to radiologically relevant levels of hypoxia is unlikely to occur in bulk tissue under FLASH irradiation. For the same dose, FLASH irradiation induces less oxygen consumption than conventional irradiation in vitro, which may be related to the FLASH sparing effect. However, the difference in oxygen depletion between FLASH and conventional irradiation could not be quantified in vivo because measurements of oxygen depletion under conventional irradiation are hampered by resupply of oxygen from the blood.


Asunto(s)
Neoplasias Experimentales/radioterapia , Oxígeno/análisis , Animales , Ratones , Neoplasias Experimentales/metabolismo , Consumo de Oxígeno , Dosificación Radioterapéutica