Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 126
Filter
1.
JACS Au ; 4(2): 760-770, 2024 Feb 26.
Article in English | MEDLINE | ID: mdl-38425914

ABSTRACT

We reported over 20 years ago MNS-4.1, the first DNA aptamer with a micromolar affinity for cocaine. MNS-4.1 is based on a structural motif that is very common in any random pool of oligonucleotides, and it is actually a nonspecific hydrophobic receptor with wide cross-reactivity with alkaloids and steroids. Despite such weaknesses preventing broad applications, this aptamer became widely used in proof-of-concept demonstrations of new formats of biosensors. We now report a series of progressively improved DNA aptamers recognizing cocaine, with the final optimized receptors having low nanomolar affinity and over a thousand-fold selectivity over the initial cross-reactants. In the process of optimization, we tested different methods to eliminate cross-reactivities and improve affinity, eventually achieving properties that are comparable to those of the reported monoclonal antibody candidates for the therapy of overdose. Multiple aptamers that we now report share structural motifs with the previously reported receptor for serotonin. Further mutagenesis studies revealed a palindromic, highly adaptable, broadly cross-reactive hydrophobic motif that could be rebuilt through mutagenesis, expansion of linker regions, and selections into receptors with exceptional affinities and varying specificities.

2.
Nat Nanotechnol ; 19(5): 660-667, 2024 May.
Article in English | MEDLINE | ID: mdl-38233588

ABSTRACT

Small molecules such as neurotransmitters are critical for biochemical functions in living systems. While conventional ultraviolet-visible spectroscopy and mass spectrometry lack portability and are unsuitable for time-resolved measurements in situ, techniques such as amperometry and traditional field-effect detection require a large ensemble of molecules to reach detectable signal levels. Here we demonstrate the potential of carbon-nanotube-based single-molecule field-effect transistors (smFETs), which can detect the charge on a single molecule, as a new platform for recognizing and assaying small molecules. smFETs are formed by the covalent attachment of a probe molecule, in our case a DNA aptamer, to a carbon nanotube. Conformation changes on binding are manifest as discrete changes in the nanotube electrical conductance. By monitoring the kinetics of conformational changes in a binding aptamer, we show that smFETs can detect and quantify serotonin at the single-molecule level, providing unique insights into the dynamics of the aptamer-ligand system. In particular, we show the involvement of G-quadruplex formation and the disruption of the native hairpin structure in the conformational changes of the serotonin-aptamer complex. The smFET is a label-free approach to analysing molecular interactions at the single-molecule level with high temporal resolution, providing additional insights into complex biological processes.


Subject(s)
Aptamers, Nucleotide , Nanotubes, Carbon , Serotonin , Transistors, Electronic , Aptamers, Nucleotide/chemistry , Nanotubes, Carbon/chemistry , Kinetics , Ligands , Serotonin/chemistry , Serotonin/metabolism , Biosensing Techniques/methods , Biosensing Techniques/instrumentation
3.
Biosens Bioelectron ; 246: 115842, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38042051

ABSTRACT

Therapeutic antibodies that block viral entry have already proven to be important, first line drugs for treatments of viral infections. In the case of SARS-CoV-2, combinations of multiple therapeutic antibodies may need to be rapidly identified and formulated in a way that blocks each new, predominant variant of the virus. For efficient introduction of any new antibody combination into patients, it is important to be able to monitor patient-specific pharmacokinetics of individual antibodies, which would include the time course of their specific capacity to block the viral spike proteins. Here, we present three examples of microfluidic-based rapid isolation of companion reagents useful for establishing combination antibody therapies. These reagents are specific three-dimensional imprints of variable regions of individual human monoclonal antibodies against the -spike protein of SARS-CoV-2 virus in the form of oligonucleotide-based ligands (aptamers). We implement these anti-idiotypic aptamers as bioreceptors in graphene-based field-effect transistor sensors to accomplish label free, rapid, and sensitive detection of matching antibodies within minutes. Through this work we have demonstrated the general applicability of anti-idiotype aptamers as capture reagents in quantification of active forms of monoclonal antibodies in complex biological mixtures.


Subject(s)
Biosensing Techniques , COVID-19 , Humans , Spike Glycoprotein, Coronavirus , SARS-CoV-2 , Antibodies, Monoclonal , Antibodies, Viral
5.
Cells ; 12(24)2023 12 18.
Article in English | MEDLINE | ID: mdl-38132177

ABSTRACT

We can formulate mixtures of oligonucleotide-antibody conjugates to act as molecular cascade-based automata that analyze pairs of cell surface markers (CD markers) on individual cells in a manner consistent with the implementation of Boolean logic-for example, by producing a fluorescent label only if two markers are present. While traditional methods to characterize cells are based on transducing signals from individual cell surface markers, these cascades can be used to combine into a single signal the presence of two or even more CDs. In our original design, oligonucleotide components irreversibly flowed from one antibody to another, driven by increased hybridizations, leading to the magnitude of the final signal on each cell being determined by the surface marker that was the least abundant. This is a significant limitation to the precise labeling of narrow subpopulations, and, in order to overcome it, we changed our design to accomplish signal amplification to a more abundant cell surface marker. We show the AMPLIFY function on two examples: (1) we amplify the fluorescent label from the CD19 marker onto a fivefold more abundant CD45, and (2) we amplify broadly distributed CD45RA to a more constant marker, CD3. We expect this new function to enable the increasingly complex Boolean analysis of cell surfaces.


Subject(s)
Antigens, CD19 , Oligonucleotides , Leukocyte Common Antigens , Cell Membrane
6.
Science ; 380(6648): 942-948, 2023 06 02.
Article in English | MEDLINE | ID: mdl-37262137

ABSTRACT

Aptameric receptors are important biosensor components, yet our ability to identify them depends on the target structures. We analyzed the contributions of individual functional groups on small molecules to binding within 27 target-aptamer pairs, identifying potential hindrances to receptor isolation-for example, negative cooperativity between sterically hindered functional groups. To increase the probability of aptamer isolation for important targets, such as leucine and voriconazole, for which multiple previous selection attempts failed, we designed tailored strategies focused on overcoming individual structural barriers to successful selections. This approach enables us to move beyond standardized protocols into functional group-guided searches, relying on sequences common to receptors for targets and their analogs to serve as anchors in regions of vast oligonucleotide spaces wherein useful reagents are likely to be found.


Subject(s)
Antifungal Agents , Aptamers, Nucleotide , Biosensing Techniques , Leucine , SELEX Aptamer Technique , Voriconazole , Aptamers, Nucleotide/chemistry , SELEX Aptamer Technique/methods , Leucine/blood , Voriconazole/analysis , Antifungal Agents/analysis
7.
Microchem J ; 1882023 May.
Article in English | MEDLINE | ID: mdl-36992861

ABSTRACT

While monitoring expression of recombinant proteins is essential for obtaining high-quality biopharmaceutical and biotechnological products, existing assays for recombinant protein detection are laborious, time-consuming and expensive. This paper presents a microfluidic approach to rapid and cost-effective detection of tag-fused recombinant proteins via a dual-aptamer sandwich assay. Our approach addresses limitations in current methods for both dual-aptamer assays and generation of aptamers for such assays by first using microfluidic technology to isolate the aptamers rapidly and then employing these aptamers to implement a microfluidic dual-aptamer assay for tag-fused recombinant protein detection. The use of microfluidic technology enables the fast generation of aptamers and rapid detection of recombinant proteins with minimized consumption of reagents. In addition, compared with antibodies, aptamers as low-cost affinity reagents with an ability of reversible denaturation further decreases the cost of recombinant protein detection. For demonstration, an aptamer pair is isolated rapidly toward His-tagged IgE within two days, and then used in the microfluidic dual-aptamer assay for detecting His-tagged IgE in cell culture media within 10 min and with a limit of detection of 7.1 nM.

8.
Bioconjug Chem ; 34(1): 124-132, 2023 01 18.
Article in English | MEDLINE | ID: mdl-36044602

ABSTRACT

Electrochemical aptamer-based (EAB) sensors utilize the binding-induced conformational change of an electrode-attached, redox-reporter-modified aptamer to transduce target recognition into an easily measurable electrochemical output. Because this signal transduction mechanism is single-step and rapidly reversible, EAB sensors support high-frequency, real-time molecular measurements, and because it recapitulates the reagentless, conformation-linked signaling seen in vivo among naturally occurring receptors, EAB sensors are selective enough to work in the complex, time-varying environments found in the living body. The fabrication of EAB sensors, however, requires that their target-recognizing aptamer be modified such that (1) it undergoes the necessary binding-induced conformational change and (2) that the thermodynamics of this "conformational switch" are tuned to ensure that they reflect an acceptable trade-off between affinity and signal gain. That is, even if an "as-selected" aptamer achieves useful affinity and specificity, it may fail when adapted to the EAB platform because it lacks the binding-induced conformational change required to support EAB signaling. In this paper we reveal the spectroscopy-guided approaches we use to modify aptamers such that they support the necessary binding-induced conformational change. Specifically, using newly reported aptamers, we demonstrate the systematic design of EAB sensors achieving clinically and physiologically relevant specificity, limits of detection, and dynamic range against the targets methotrexate and tryptophan.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Aptamers, Nucleotide/chemistry , Biosensing Techniques/methods , Oxidation-Reduction , Electrodes , Spectrum Analysis , Electrochemical Techniques/methods
9.
ACS Sens ; 8(1): 150-157, 2023 01 27.
Article in English | MEDLINE | ID: mdl-36534756

ABSTRACT

Dose-limiting toxicity and significant patient-to-patient pharmacokinetic variability often render it difficult to achieve the safe and effective dosing of drugs. This is further compounded by the slow, cumbersome nature of the analytical methods used to monitor patient-specific pharmacokinetics, which inevitably rely on blood draws followed by post-facto laboratory analysis. Motivated by the pressing need for improved "therapeutic drug monitoring", we are developing electrochemical aptamer-based (EAB) sensors, a minimally invasive biosensor architecture that can provide real-time, seconds-resolved measurements of drug levels in situ in the living body. A key advantage of EAB sensors is that they are generalizable to the detection of a wide range of therapeutic agents because they are independent of the chemical or enzymatic reactivity of their targets. Three of the four therapeutic drug classes that have, to date, been shown measurable using in vivo EAB sensors, however, bind to nucleic acids as part of their mode of action, leaving open questions regarding the extent to which the approach can be generalized to therapeutics that do not. Here, we demonstrate real-time, in vivo measurements of plasma methotrexate, an antimetabolite (a mode of action not reliant on DNA binding) chemotherapeutic, following human-relevant dosing in a live rat animal model. By providing hundreds of drug concentration values, the resulting seconds-resolved measurements succeed in defining key pharmacokinetic parameters, including the drug's elimination rate, peak plasma concentration, and exposure (area under the curve), with unprecedented 5 to 10% precision. With this level of precision, we easily identify significant (>2-fold) differences in drug exposure occurring between even healthy rats given the same mass-adjusted methotrexate dose. By providing a real-time, seconds-resolved window into methotrexate pharmacokinetics, such measurements can be used to precisely "individualize" the dosing of this significantly toxic yet vitally important chemotherapeutic.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Nucleic Acids , Humans , Rats , Animals , Methotrexate , Biosensing Techniques/methods , Drug Monitoring/methods
10.
Bioconjug Chem ; 34(1): 92-96, 2023 01 18.
Article in English | MEDLINE | ID: mdl-36006852

ABSTRACT

Binding between streptavidin, or its homologues, to biotin is one of the most widely exploited biological interactions in the biomedical sciences. Controlling the extent of biotinylation is important for meeting the requirements of the intended design and to preserve the native function of the biotin recipient. Within the protein world, a"trial-and-error" optimization approach toward biotinylation reaction conditions is often necessary due to widely varying properties of proteins. Therefore, product analysis is important. We show here that a oligonucleotide-blocked streptavidin, effectively "monovalent streptavidin", can tag biotin moieties individually and the tagged products visualized via a polyacrylamide gel shift assay to reveal the product distribution, i.e., [protein-(biotin)n] products where n = 1, 2, 3, etc. This is in contrast, and complementary, to current commercially available analytical reagents for biotinylation characterization, which use an absorbance or fluorescence signal to yield the mean number of biotin moieties.


Subject(s)
Biotin , Proteins , Streptavidin/chemistry , Biotin/chemistry , Biotinylation , Proteins/metabolism , Indicators and Reagents
11.
Biomed Microdevices ; 25(1): 3, 2022 12 08.
Article in English | MEDLINE | ID: mdl-36480127

ABSTRACT

Multiple myeloma (MM) is a bone marrow cancer of resident plasma cells that affects 125,000 patients in the U.S. with about 30,000 new cases per year. Its signature is the clonal proliferation of a single plasma cell that secretes a patient specific monoclonal immunoglobulin (M-Ig). Targeting the M-Ig in patient serum could allow sensitive and noninvasive identification of minimal residual disease in multiple myeloma. Aptamers, which are single-stranded oligonucleotides with affinity and specificity to a target molecule, have recently been introduced as affinity reagents for recognition of MM M-Igs. Here we exploit microfluidic SELEX technology to enable rapid and efficient generation of aptamers against M-Ig proteins from MM patients. We first characterize the technology by isolating aptamers with affinity towards the monoclonal antibody rituximab as a model M-Ig and then apply the technology to isolating aptamers specifically targeting M-Igs obtained from serum samples of MM patients. We demonstrate that high-affinity DNA aptamers (KD < 50 nM) for M-Ig proteins from a patient sample could be isolated via microfluidic SELEX within approximately 12 h and using less than 100 micrograms of patient M-Ig. Such aptamers can potentially be used in personalized monitoring of minimal residual disease in MM patients.


Subject(s)
Multiple Myeloma , Humans , Neoplasm, Residual , Microfluidics , Antibodies, Monoclonal
13.
Appl Radiat Isot ; 184: 110207, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35316779

ABSTRACT

This paper presents a detailed statistical analysis of experimental results of dynamic breakdown voltage and electrical breakdown time delay for xenon-filled diode. These quantities have a stochastic nature and they were measured in the cases when the xenon-filled diode was and was not exposed to a gamma radiation source, with exposure dose rate 7.7⋅10-12 C/(kg⋅s). The static breakdown voltage was estimated based on dynamic breakdown voltage as a function of voltage increase rate. The applicability of certain distributions to experimental dynamic breakdown voltage and electrical breakdown time delay data was also analyzed.


Subject(s)
Xenon , Gamma Rays
14.
Nanomaterials (Basel) ; 12(3)2022 Jan 31.
Article in English | MEDLINE | ID: mdl-35159843

ABSTRACT

The electrospinnability of FucoPol, a bacterial exopolysaccharide, is presented for the first time, evaluated alone and in combination with other polymers, such as polyethylene oxide (PEO) and pullulan. The obtained fibers were characterized in terms of their morphological, structural and thermal properties. Pure FucoPol fibers could not be obtained due to FucoPol's low water solubility and a lack of molecular entanglements. Nanofibers were obtained via blending with PEO and pullulan. FucoPol:PEO (1:3 w/w) showed fibers with well-defined cylindrical structure, since the higher molecular weight of PEO helps the continuity of the erupted jet towards the collector, forming stable fibers. WAXS, DSC and TGA showed that FucoPol is an amorphous biopolymer, stable until 220 °C, whereas FucoPol-PEO fibers were stable until 140 °C, and FucoPol:pullulan fibers were stable until 130 °C. Interestingly, blended components influenced one another in intermolecular order, since new peaks associated to intermolecular hierarchical assemblies were seen by WAXS. These results make FucoPol-based systems viable candidates for production of nanofibers for packaging, agriculture, biomedicine, pharmacy and cosmetic applications.

15.
Sci Adv ; 8(1): eabk0967, 2022 Jan 07.
Article in English | MEDLINE | ID: mdl-34985954

ABSTRACT

Wearable technologies for personalized monitoring require sensors that track biomarkers often present at low levels. Cortisol­a key stress biomarker­is present in sweat at low nanomolar concentrations. Previous wearable sensing systems are limited to analytes in the micromolar-millimolar ranges. To overcome this and other limitations, we developed a flexible field-effect transistor (FET) biosensor array that exploits a previously unreported cortisol aptamer coupled to nanometer-thin-film In2O3 FETs. Cortisol levels were determined via molecular recognition by aptamers where binding was transduced to electrical signals on FETs. The physiological relevance of cortisol as a stress biomarker was demonstrated by tracking salivary cortisol levels in participants in a Trier Social Stress Test and establishing correlations between cortisol in diurnal saliva and sweat samples. These correlations motivated the development and on-body validation of an aptamer-FET array­based smartwatch equipped with a custom, multichannel, self-referencing, and autonomous source measurement unit enabling seamless, real-time cortisol sweat sensing.

19.
Pain Med ; 22(6): 1441-1464, 2021 06 04.
Article in English | MEDLINE | ID: mdl-33839780

ABSTRACT

MYTH: Corticosteroid injection for the treatment of pain is known to decrease the efficacy of the adenovirus vector-based vaccines for COVID-19. FACT: There is currently no direct evidence to suggest that a corticosteroid injection before or after the administration of an adenovirus vector-based COVID-19 vaccine decreases the efficacy of the vaccine. However, based on the known timeline of hypothalamic-pituitary-adrenal axis suppression following epidural and intraarticular corticosteroid injections, and the timeline of the reported peak efficacy of the Janssen and AstraZeneca vaccines, physicians should consider timing an elective corticosteroid injection such that it is administered no less than 2 weeks prior to and no less than 2 weeks following a COVID-19 adenovirus vector-based vaccine dose, whenever possible. We emphasize the importance of risk/benefit analysis and shared decision making in determining the timing of corticosteroid injections for pain indications in relation to receipt of a COVID-19 vaccine given that patient-specific factors will vary.


Subject(s)
COVID-19 Vaccines , COVID-19 , Adenoviridae/genetics , Adrenal Cortex Hormones , Humans , Hypothalamo-Hypophyseal System , Pain/drug therapy , Pituitary-Adrenal System , SARS-CoV-2
20.
Pain Med ; 22(4): 994-1000, 2021 04 20.
Article in English | MEDLINE | ID: mdl-33605425

ABSTRACT

MYTH: Corticosteroid injection for the treatment of pain and inflammation is known to decrease the efficacy of the messenger ribonucleic acid (mRNA) vaccines for coronavirus disease 2019 (COVID-19). FACT: There is currently no direct evidence to suggest that a corticosteroid injection before or after the administration of an mRNA COVID-19 vaccine decreases the efficacy of the vaccine.However, based on the known timeline of hypothalamic-pituitary-adrenal (HPA) axis suppression following epidural and intraarticular corticosteroid injections, and the timeline of the reported peak efficacy of the Pfizer-BioNTech and Moderna vaccines, physicians should consider timing an elective corticosteroid injection such that it is administered no less than 2 weeks prior to a COVID-19 mRNA vaccine dose and no less than 1 week following a COVID-19 mRNA vaccine dose, whenever possible.


Subject(s)
Adrenal Cortex Hormones/administration & dosage , COVID-19 Vaccines/administration & dosage , COVID-19 , Pain/drug therapy , Vaccines, Synthetic/administration & dosage , Humans , Time Factors , mRNA Vaccines
SELECTION OF CITATIONS
SEARCH DETAIL
...