J Appl Clin Med Phys ; : e14430, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38952071

ABSTRACT

PURPOSE: The purpose of this work was to detail our center's experience in transitioning from a Co-60 treatment technique to an intensity modulated radiation therapy (IMRT) based lateral-field extended source-to-axis distance (e-SAD) technique for total body irradiation (TBI). MATERIALS AND METHODS: An existing beam model in RayStation v.10A was validated for the use of e-SAD TBI treatments. Data were acquired with an Elekta Synergy linear accelerator (LINAC) at an extended source-to-surface distance of 365 cm with an 18 MV beam. Beam model validation measurements included percentage depth dose (PDD), profile data, surface dose, build-up region and transmission measurements. End-to-end testing was carried out using an anthropomorphic phantom. Treatments were performed in a supine position in a whole-body Vac-Lok at an e-SAD of 400 cm with a beam spoiler 10 cm from the couch. Planning was achieved using IMRT, where multi-leaf collimators were used to modulate the beam and shield the organs at risk. Beam's eye view projection images were used for in-room patient positioning and in-vivo dosimetry was performed for every treatment. RESULTS: The percent difference between the measured and calculated PDD and profiles was less than 2% at all locations. Surface dose was 83.8% of the maximum dose with the beam spoiler at a 10 cm distance from the phantom. The largest percent difference between the treatment planning system (TPS) and measured data within the anthropomorphic phantom was approximately 2%. In-vivo dosimetry measurements yielded results within the 5% institutional threshold. CONCLUSION: In 2022, 17 patients were successfully treated using the new IMRT-based lateral-field e-SAD TBI technique. The resulting clinical plans respected the institutional standard. The commissioning process, as well as the treatment planning and delivery aspects were described in this work with the intention of supporting other clinics in implementing this treatment method.

2.
Radiol Phys Technol ; 2024 Jul 19.
Article in English | MEDLINE | ID: mdl-39028438

ABSTRACT

In this study, we aimed to conduct a survey on the current clinical practice of, staffing for, commissioning of, and staff training for online adaptive radiotherapy (oART) in the institutions that installed commercial oART systems in Japan, and to share the information with institutions that will implement oART systems in future. A web-based questionnaire, containing 107 questions, was distributed to nine institutions in Japan. Data were collected from November to December 2023. Three institutions each with the MRIdian (ViewRay, Oakwood Village, OH, USA), Unity (Elekta AB, Stockholm, Sweden), and Ethos (Varian Medical Systems, Palo Alto, CA, USA) systems completed the questionnaire. One institution (MRIdian) had not performed oART by the response deadline. Each institution had installed only one oART system. Hypofractionation, and moderate hypofractionation or conventional fractionation were employed in the MRIdian/Unity and Ethos systems, respectively. The elapsed time for the oART process was faster with the Ethos than with the other systems. All institutions added additional staff for oART. Commissioning periods differed among the oART systems owing to provision of beam data from the vendors. Chambers used during commissioning measurements differed among the institutions. Institutional training was provided by all nine institutions. To the best of our knowledge, this was the first survey about oART performed using commercial systems in Japan. We believe that this study will provide useful information to institutions that installed, are installing, or are planning to install oART systems.

3.
Phys Med ; 123: 103411, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38906045

ABSTRACT

PURPOSE: To develop and characterize a large-area multi-strip ionization chamber (MSIC) for efficient measurement of proton beam spot size and position at a synchrotron-based proton therapy facility. METHODS AND MATERIALS: A 420 mm x 320 mm MSIC was designed with 240 vertical strips and 180 horizontal strips at 1.75 mm pitch. The MSIC was characterized by irradiating a grid of proton spots across 17 energies from 73.5 MeV to 235 MeV and comparing to simultaneous measurements made with a reference Gafchromic EBT3 film. Beam profiles, spot sizes, and positions were analyzed. Short term measurement stability and sensitivity were evaluated. RESULTS: Excellent agreement was demonstrated between the MSIC and EBT3 film for both spot size and position measurements. Spot sizes agreed within ± 0.18 mm for all energies tested. Measured beam spot positions agreed within ± 0.17 mm. The detector showed good short term measurement stability and low noise performance. CONCLUSION: The large-area MSIC enables efficient and accurate proton beam spot characterization across the clinical energy range. The results indicate the MSIC is suitable for pencil beam scanning proton therapy commissioning and quality assurance applications requiring fast spot size and position quantification.


Subject(s)
Proton Therapy , Proton Therapy/instrumentation , Radiometry/instrumentation , Synchrotrons/instrumentation
4.
Public Money Manag ; 44(4): 298-307, 2024.
Article in English | MEDLINE | ID: mdl-38919878

ABSTRACT

IMPACT: This article suggests why a different approach may be required for commissioning services from third sector providers than from, say, corporate or public providers. English systems for commissioning third sector providers contain both commodified elements (for example formal procurement, provider competition, commissioner-provider separation) and collaborative, relational elements (for example long-term collaboration, reliance on inter-organizational networks). When the two elements conflicted, commissioners and third sector organizations tended to try to work around the commodified elements in order to preserve and develop the collaborative aspects, which suggests that, in practice, they find de-commodified, collaborative methods better adapted to the commissioning of third sector organizations. ABSTRACT: When publicly-funded services are outsourced, governments still use multiple governance structures to retain some control over the services provided. Using realist methods the authors systematically compared this aspect of community health activities provided by third sector organizations in six English localities during 2020-2022. Two modes of commissioning coexisted. Commodified commissioning largely embodied Washington consensus models of formal, competitive procurement. A contrasting, collaborative mode of commissioning relied more upon relational, long-term co-operation and networking among organizations. When the two modes conflicted, commissioners often favoured the collaborative mode and sought to adjust their commissioning to make it less commodified.

5.
ArXiv ; 2024 May 24.
Article in English | MEDLINE | ID: mdl-38827455

ABSTRACT

Background & Purpose: FLASH or ultra-high dose rate (UHDR) radiation therapy (RT) has gained attention in recent years for its ability to spare normal tissues relative to conventional dose rate (CDR) RT in various preclinical trials. However, clinical implementation of this promising treatment option has been limited because of the lack of availability of accelerators capable of delivering UHDR RT. Commercial options are finally reaching the market that produce electron beams with average dose rates of up to 1000 Gy/s. We established a framework for the acceptance, commissioning, and periodic quality assurance (QA) of electron FLASH units and present an example of commissioning. Methods: A protocol for acceptance, commissioning, and QA of UHDR linear accelerators was established by combining and adapting standards and professional recommendations for standard linear accelerators based on the experience with UHDR at four clinical centers that use different UHDR devices. Non-standard dosimetric beam parameters considered included pulse width, pulse repetition frequency, dose per pulse, and instantaneous dose rate, together with recommendations on how to acquire these measurements. Results: The 6- and 9-MeV beams of an UHDR electron device were commissioned by using this developed protocol. Measurements were acquired with a combination of ion chambers, beam current transformers (BCTs), and dose-rate-independent passive dosimeters. The unit was calibrated according to the concept of redundant dosimetry using a reference setup. Conclusions: This study provides detailed recommendations for the acceptance testing, commissioning, and routine QA of low-energy electron UHDR linear accelerators. The proposed framework is not limited to any specific unit, making it applicable to all existing eFLASH units in the market. Through practical insights and theoretical discourse, this document establishes a benchmark for the commissioning of UHDR devices for clinical use.

6.
Health Expect ; 27(3): e14053, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38698629

ABSTRACT

INTRODUCTION: This exploratory literature review seeks to examine the literature around commissioning processes in the co-production of health and care services, focusing on two questions: How do health and care commissioning processes facilitate and/or pose barriers to co-production in service design and delivery? What are the contextual factors that influence these processes? METHOD: A systematic search of three databases (Medline, Public Health and Social Policy and Practice) and a search platform (Web of Science) was conducted for the period 2008-2023. A total of 2675 records were retrieved. After deduplication, 1925 were screened at title and abstract level. Forty-seven reports from 42 United Kingdom and Ireland studies were included in the review. A thematic synthesis of included studies was conducted in relation to the research questions. RESULTS: The review identified one overarching theme across the synthesised literature: the complexity of the commissioning landscape. Three interconnected subthemes illuminate the contextual factors that influence this landscape: commissioners as leaders of co-production; navigating relationships and the collective voice. CONCLUSION: Commissioning processes were commonly a barrier to the co-production of health and care services. Though co-production was an aspiration for many commissioners, the political and economic environment and service pressures meant that it was often not fully realised. More flexible funding models, longer-term pilot projects, an increased emphasis in social value across the health and care system and building capacity for strong leadership in commissioning is needed. PATIENT AND PUBLIC CONTRIBUTION: Patients and the public did not contribute to this review as it was a small piece of work following on from a completed project, with no budget for public involvement.


Subject(s)
Delivery of Health Care , United Kingdom , Ireland , Humans , Delivery of Health Care/organization & administration , State Medicine/organization & administration , Health Policy
7.
J Appl Clin Med Phys ; 25(6): e14379, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38700940

ABSTRACT

PURPOSE: A novel pulse normalization technology enabling the acquisition of low noise beam data without the use of a physical reference chamber has recently been commercially released. The purpose of this study was to characterize the use of this technology for beam scanning of small fields required in the commissioning of a stereotactic radiotherapy program. METHODS: Three detectors (Edge diode, microDiamond, PinPoint) were used to acquire beam data under three conditions: with a reference chamber, with pulse normalization and no reference chamber (PN), and without pulse normalization and no reference chamber (nPN). Percent depth dose (PDD) scans were acquired for 0.5, 1.0, 2.0, and 3.0 cm2 field sizes and profiles were acquired at 1.4, 10, and 30 cm depths using continuous scanning. The coefficient of variation (CoV) was calculated for all beam data to compare signal-to-noise and gamma comparisons (1%, 1 mm) were calculated of the PN and nPN scans compared to the reference data. RESULTS: Average 95th percentile CoV values were similar for all detectors across conditions, with PN data being comparable to reference data and minor increases observed for nPN data. Mean gamma pass rates for PN PDD scans exceeded 98% for all detectors. Profile gamma pass rates were 100% for all detectors at 1.4 and 10 cm depth. At 30 cm depth, profiles acquired with the PinPoint and microDiamond detectors had lower mean gamma pass rates than the Edge, at 95% and 95.7%, respectively. CONCLUSIONS: A novel pulse normalization technology was demonstrated to be effective for acquiring beam profiles and PDDs for small fields without the use of a physical reference chamber. Limitations in how the method is implemented led to some errors in data acquired using lower sensitivity detectors. When used with a diode, pulse normalization produced equivalent scans to those acquired with a reference chamber.


Subject(s)
Radiosurgery , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Humans , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Phantoms, Imaging , Radiometry/methods , Radiometry/instrumentation , Particle Accelerators/instrumentation , Radiotherapy, Intensity-Modulated/methods , Signal-To-Noise Ratio
8.
J Appl Clin Med Phys ; : e14392, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38742858

ABSTRACT

PURPOSE: The purpose of this study was to validate the use of a model-based dose calculation algorithm (MBDCA), Acuros BV, for high dose rate brachytherapy treatment planning for a community-based hospital with a Bravos afterloader. Based on published AAPM recommendations, this work details a practical approach for community-based clinics to complete initial validation of Acuros BV, in order to add a MBDCA to a TG-43 based brachytherapy treatment planning program. METHODS: Source dimensions and materials used in Acuros BV and TG-43 source models were compared to the physical source. TG-186 testing was completed with standardized test cases externally calculated with Monte Carlo compared to locally calculated with Acuros BV. Point doses calculated using TG-43 were compared to those calculated with Acuros BV in water at various dose grid settings. Secondary dose check software was used to evaluate dose distributions resembling clinical patient plans, both in water and on CT datasets representative of patient anatomy. RESULTS: The major source of discrepancy of source models was the length of modeled steel cable. TG-186 testing showed that the largest differences between Monte Carlo and Acuros BV dose distributions were located along the source axis for cases calculated in water, as well as located in regions of high dose gradients and within the applicator for the case calculated with a generic shielded applicator. An audit of point doses calculated with both TG-43 and Acuros BV in water found that dose grid settings significantly affected agreement. Secondary dose check software indicated that Acuros BV functioned satisfactorily, and a 5% threshold was adopted for secondary dose checks on gynecologic plans. CONCLUSION: This validation process indicated that Acuros BV met expected standards and affirmed its suitability for integration into this clinical practice's brachytherapy treatment planning.

9.
Int J Part Ther ; 11: 100011, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38757079

ABSTRACT

Purpose: We performed computed tomography (CT)-stopping power ratio (SPR) calibration in a carbon-ion therapy facility and evaluated SPR estimation accuracy. Materials and Methods: A polybinary tissue model method was used for the calibration of CT numbers and SPR. As a verification by dose calculation, we created a virtual phantom to which the CT-SPR calibration table was applied. Then, SPR was calculated from the change in the range of the treatment planning beam when changing to 19 different CT numbers, and the accuracy of the treatment planning system (TPS) calculation of SPR values from the CT-SPR calibration table was validated. As a verification by measurement, 5 materials (water, milk, olive oil, ethanol, 40% K2HPO4) were placed in a container, and the SPR was obtained by measurement from the change in the range of the beam that passed through the materials. Results: The results of the dose calculations of the TPS showed that the results agreed within 1% for the lower CT numbers up to 1000 HU, but there was a difference of 3.0% in the higher CT number volume. The difference between the SPR calculated by TPS and the SPR caused by the difference in the energy of the incident particles agreed within 0.51%. The accuracy of SPR estimation was measured, and the error was within 2% for all materials tested. Conclusion: These results indicate that the SPR estimation errors are within the range of errors that can be expected in particle therapy. From commissioning and verification results, the CT-SPR calibration table obtained during this commissioning process is clinically applicable.

10.
Arch Public Health ; 82(1): 54, 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38654372

ABSTRACT

BACKGROUND: Despite several interventions demonstrating benefit to people living with dementia and their caregivers, few have been translated and implemented in routine clinical practice. There is limited evidence of the barriers and facilitators for commissioning and implementing health and social care interventions for people living with dementia. The aim of the current study was to explore the barriers and facilitators to commissioning and implementing health and social care interventions for people with dementia, using a dementia friendly exercise and physical activity-based intervention (PrAISED [Promoting Activity, Stability and Independence in Early Dementia and Mild Cognitive Impairment]) as a case study. METHODS: Qualitative semi-structured interviews were conducted with stakeholders from a range of backgrounds including individuals from health and social care, local government, the voluntary and community sector, universities, and research centres in England. The Consolidated Framework for Intervention Research (CFIR) was used to guide the design and analysis. RESULTS: Fourteen participants took part, including commissioning managers, service managers, partnership managers, charity representatives, commercial research specialists, academics/researchers, and healthcare professionals. Data were represented in 33 constructs across the five CFIR domains. Participants identified a need for greater support for people diagnosed with dementia and their caregivers immediately post dementia diagnosis. Key barriers included cost/financing, the culture of commissioning, and available resources. Key facilitators included the adaptability of the intervention, cosmopolitanism/partnerships and connections, external policy and incentives, and the use of already existing (and untapped) workforces. CONCLUSION: Several barriers and facilitators for commissioning and implementing health and social care interventions for people with dementia were identified which need to be addressed. Recommended actions to facilitate the commissioning and implementation of dementia friendly services are: 1) map out local needs, 2) evidence the intervention including effectiveness and cost-effectiveness, 3) create/utilise networks with stakeholders, and 4) plan required resources.

11.
BMC Public Health ; 24(1): 1197, 2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38684984

ABSTRACT

BACKGROUND: Social and Therapeutic Horticulture (STH) is a process where trained practitioners work with plants and people to improve an individual's physical and psychological health, communication and thinking skills. Evidence suggests that STH can support individuals with mental ill-health, however, current commissioning of STH within mental health care is limited. This study aimed to understand the barriers to commissioning STH in mental health care and to identify potential solutions to barriers, to support more widespread availability of services.  METHODS: Individuals with a role in mental health care commissioning from across the UK were invited to take part in semi-structured interviews via zoom. Interviews explored factors influencing the mental health services they commission or refer to, their perception of the role of STH in mental health care and the barriers to commissioning STH, together with potential solutions to any barriers identified. RESULTS: Commissioners identified a lack of knowledge of STH and evidence of its effectiveness, and a culture which prioritises traditional medical models, as barriers to commissioning. Challenges for STH providers in responding to large-scale commissioning requirements were also highlighted as a barrier. CONCLUSIONS: To upscale commissioning of STH in mental health care, STH interventions need to be embedded within NHS priorities and information on STH services and their effectiveness needs to be easily accessible to practitioners. The sector should also be supported in working collaboratively to enable commissioning of services at scale.


Subject(s)
Mental Health Services , Qualitative Research , Humans , Mental Health Services/organization & administration , United Kingdom , Horticultural Therapy , Mental Disorders/therapy , Interviews as Topic , State Medicine/organization & administration
12.
J Appl Clin Med Phys ; 25(5): e14328, 2024 May.
Article in English | MEDLINE | ID: mdl-38553788

ABSTRACT

PURPOSE: Experimental patient-specific QA (PSQA) is a time and resource-intensive process, with a poor sensitivity in detecting errors. Radiation therapy facilities aim to substitute it by means of independent dose calculation (IDC) in combination with a comprehensive beam delivery QA program. This paper reports on the commissioning of the IDC software tool myQA iON (IBA Dosimetry) for proton therapy and its clinical implementation at the MedAustron Ion Therapy Center. METHODS: The IDC commissioning work included the validation of the beam model, the implementation and validation of clinical CT protocols, and the evaluation of patient treatment data. Dose difference maps, gamma index distributions, and pass rates (GPR) have been reviewed. The performance of the IDC tool has been assessed and clinical workflows, simulation settings, and GPR tolerances have been defined. RESULTS: Beam model validation showed agreement of ranges within ± 0.2 mm, Bragg-Peak widths within ± 0.1 mm, and spot sizes at various air gaps within ± 5% compared to physical measurements. Simulated dose in 2D reference fields deviated by -0.3% ± 0.5%, while 3D dose distributions differed by 1.8% on average to measurements. Validation of the CT calibration resulted in systematic differences of 2.0% between IDC and experimental data for tissue like samples. GPRs of 99.4 ± 0.6% were found for head, head and neck, and pediatric CT protocols on a 2%/2 mm gamma criterion. GPRs for the adult abdomen protocol were at 98.9% on average with 3%/3 mm. Root causes of GPR outliers, for example, implants were identified and evaluated. CONCLUSION: IDC has been successfully commissioned and integrated into the MedAustron clinical workflow for protons in 2021. IDC has been stepwise and safely substituting experimental PSQA since February 2021. The initial reduction of proton experimental PSQA was about 25% and reached up to 90% after 1 year.


Subject(s)
Organs at Risk , Proton Therapy , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Software , Humans , Proton Therapy/methods , Radiotherapy Planning, Computer-Assisted/methods , Organs at Risk/radiation effects , Quality Assurance, Health Care/standards , Phantoms, Imaging , Radiotherapy, Intensity-Modulated/methods , Calibration , Neoplasms/radiotherapy , Tomography, X-Ray Computed/methods , Algorithms
13.
Radiat Oncol ; 19(1): 40, 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38509543

ABSTRACT

PURPOSE: To assess a large panel of MR compatible detectors on the full range of measurements required for a 0.35 T MR-linac commissioning by using a specific statistical method represented as a continuum of comparison with the Monte Carlo (MC) TPS calculations. This study also describes the commissioning tests and the secondary MC dose calculation validation. MATERIAL AND METHODS: Plans were created on the Viewray TPS to generate MC reference data. Absolute dose points, PDD, profiles and output factors were extracted and compared to measurements performed with ten different detectors: PTW 31010, 31021, 31022, Markus 34045 and Exradin A28 MR ionization chambers, SN Edge shielded diode, PTW 60019 microdiamond, PTW 60023 unshielded diode, EBT3 radiochromic films and LiF µcubes. Three commissioning steps consisted in comparison between calculated and measured dose: the beam model validation, the output calibration verification in four different phantoms and the commissioning tests recommended by the IAEA-TECDOC-1583. MAIN RESULTS: The symmetry for the high resolution detectors was higher than the TPS data of about 1%. The angular responses of the PTW 60023 and the SN Edge were - 6.6 and - 11.9% compared to the PTW 31010 at 60°. The X/Y-left and the Y-right penumbras measured by the high resolution detectors were in good agreement with the TPS values except for the PTW 60023 for large field sizes. For the 0.84 × 0.83 cm2 field size, the mean deviation to the TPS of the uncorrected OF was - 1.7 ± 1.6% against - 4.0 ± 0.6% for the corrected OF whereas we found - 4.8 ± 0.8% for passive dosimeters. The mean absolute dose deviations to the TPS in different phantoms were 0 ± 0.4%, - 1.2 ± 0.6% and 0.5 ± 1.1% for the PTW 31010, PTW 31021 and Exradin A28 MR respectively. CONCLUSIONS: The magnetic field effects on the measurements are considerably reduced at low magnetic field. The PTW 31010 ionization chamber can be used with confidence in different phantoms for commissioning and QA tests requiring absolute dose verifications. For relative measurements, the PTW 60019 presented the best agreement for the full range of field size. For the profile assessment, shielded diodes had a behaviour similar to the PTW 60019 and 60023 while the ionization chambers were the most suitable detectors for the symmetry. The output correction factors published by the IAEA TRS 483 seem to be applicable at low magnetic field pending the publication of new MR specific values.


Subject(s)
Particle Accelerators , Radiometry , Humans , Radiometry/methods , Monte Carlo Method , Phantoms, Imaging , Calibration
14.
Radiol Phys Technol ; 17(2): 412-424, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38492203

ABSTRACT

The purpose of this study was to validate an electronic portal imaging device (EPID) based 3-dimensional (3D) dosimetry system for the commissioning of volumetric modulated arc therapy (VMAT) delivery for flattening filter (FF) and flattening filter free (FFF) modalities based on test suites developed according to American Association of Physicists in Medicine Task Group 119 (AAPM TG 119) and pre-treatment patient specific quality assurance (PSQA).With ionisation chamber, multiple-point measurement in various planes becomes extremely difficult and time-consuming, necessitating repeated exposure of the plan. The average agreement between measured and planned doses for TG plans is recommended to be within 3%, and both the ionisation chamber and PerFRACTION™ measurement were well within this prescribed limit. Both point dose differences with the planned dose and gamma passing rates are comparable with TG reported multi-institution results. From our study, we found that no significant differences were found between FF and FFF beams for measurements using PerFRACTION™ and ion chamber. Overall, PerFRACTION™ produces acceptable results to be used for commissioning and validating VMAT and for performing PSQA. The findings support the feasibility of integrating PerFRACTION™ into routine quality assurance procedures for VMAT delivery. Further multi-institutional studies are recommended to establish global baseline values and enhance the understanding of PerFRACTION™'s capabilities in diverse clinical settings.


Subject(s)
Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Radiotherapy, Intensity-Modulated/instrumentation , Radiometry/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Humans , Imaging, Three-Dimensional
15.
BMC Public Health ; 24(1): 778, 2024 Mar 12.
Article in English | MEDLINE | ID: mdl-38475750

ABSTRACT

BACKGROUND: Weight management services have not always benefitted everyone equally. People who live in more deprived areas, racially minoritised communities, those with complex additional needs (e.g., a physical or mental disability), and men are less likely to take part in weight management services. This can subsequently widen health inequalities. One way to counter this is to co-design services with under-served groups to better meet their needs. Using a case study approach, we explored how co-designed adult weight management services were developed, the barriers and facilitators to co-design, and the implications for future commissioning. METHODS: We selected four case studies of adult weight management services in Southwest England where co-design had been planned, representing a range of populations and settings. In each case, we recruited commissioners and providers of the services, and where possible, community members involved in co-design activities. Interviews were conducted online, audio-recorded, transcribed verbatim, and analysed using thematic analysis. RESULTS: We interviewed 18 participants (8 female; 10 male): seven commissioners, eight providers, and three community members involved in co-designing the services. The case studies used a range of co-design activities (planned and actualised), from light-touch to more in-depth approaches. In two case studies, co-design activities were planned but were not fully implemented due to organisational time or funding constraints. Co-design was viewed positively by participants as a way of creating more appropriate services and better engagement, thus potentially leading to reduced inequalities. Building relationships- with communities, individual community members, and with partner organisations- was critical for successful co-design and took time and effort. Short-term and unpredictable funding often hindered co-design efforts and could damage relationships with communities. Some commissioners raised concerns over the limited evidence for co-design, while others described having to embrace "a different way of thinking" when commissioning for co-design. CONCLUSIONS: Co-design is an increasingly popular approach to designing health in services but can be difficult to achieve within traditional funding and commissioning practices. Drawing on our case studies, we present key considerations for those wanting to co-design health services, noting the importance of building strong relationships, creating supportive organisational cultures, and developing the evidence base.


Subject(s)
Qualitative Research , Male , Humans , Female , England
16.
Violence Against Women ; 30(8): 1783-1803, 2024 06.
Article in English | MEDLINE | ID: mdl-38509824

ABSTRACT

The specialist voluntary sector plays a crucial role in supporting survivors of sexual violence. However, in England, short-term funding underpins the sector's financial stability. This article examines sector leaders' ways of coping, resisting and being affected by funding practices. Using the concept of edgework, we show how funding and commissioning dynamics push individuals to the edge of service sustainability, job satisfaction, and emotional well-being. We examine how these edges are "worked," for example, by circumventing and remolding the edge. We offer an original way to theorize participants, make visible the emotional toll of service precarity and offer suggestions for support.

17.
Phys Imaging Radiat Oncol ; 29: 100543, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38390588

ABSTRACT

Background and purpose: Multi-leaf collimators (MLCs) with tilted leaf sides have a complex transmission behaviour that is not easily matched by radiotherapy treatment planning systems (TPSs). We sought to develop an MLC model that can accurately match test fields and clinically relevant plans at different centres. Materials and methods: Two new MLC models were developed and evaluated within a research version of a commercial TPS. Prototype I used adjusted-constant transmissions and Prototype II used variable transmissions at the tongue-and-groove and leaf-tip regions. Three different centres evaluated these prototypes for a tilted MLC and compared them with their initial MLC model using test fields and patient-specific quality-assurance measurements of clinically relevant plans. For the latter, gamma passing rates (GPR) at 2 %/2mm were recorded. Results: For the prototypes the same set of MLC parameters could be used at all centres, with only a slight adjustment of the offset parameter. For centres A and C, average GPR were >95 % and within 0.5 % GPR difference between the standard, and prototype models. In center B, prototypes I and II improved the agreement in clinically relevant plans, with an increase in GPR of 2.3 % ± 0.8 % and 3.0 ± 0.8 %, respectively. Conclusions: The prototype MLC models were either similar or superior to the initial MLC model, and simpler to configure because fewer trade-offs were required. Prototype I performed comparably to the more sophisticated Prototype II and its configuration can be easily standardized, which can be useful to reduce variability and improve safety in clinical practice.

18.
Technol Cancer Res Treat ; 23: 15330338231225864, 2024.
Article in English | MEDLINE | ID: mdl-38311933

ABSTRACT

Purpose: This study aims to develop a data-collecting package ExpressMLC and investigate the applicability of MapCHECK2 for multileaf collimator (MLC) modeling and commissioning for complex radiation treatment plans. Materials and methods: The MLC model incorporates realistic parameters to account for sophisticated MLC features. A set of 8 single-beam plans, denoted by ExpressMLC, is created for the determination of parameters. For the commissioning of the MLC model, 4 intensity modulated radiation therapy (IMRT) plans specified by the AAPM TG 119 report were transferred to a computed tomography study of MapCHECK2, recalculated, and compared to measurements on a Varian accelerator. Both per-beam and composite-beam dose verification were conducted. Results: Through sufficient characterization of the MLC model, under 3%/2 mm and 2%/2 mm criteria, MapCHECK2 can be used to accurately verify per beam dose with gamma passing rate better than 90.9% and 89.3%, respectively, while the Gafchromic EBT3 films can achieve gamma passing rate better than 89.3% and 85.7%, respectively. Under the same criteria, MapCHECK2 can achieve composite beam dose verification with a gamma passing rate better than 95.9% and 90.3%, while the Gafchromic EBT3 films can achieve a gamma passing rate better than 96.1% and 91.8%; the p-value from the Mann Whitney test between gamma passing rates of the per beam dose verification using full MapCHECK2 package calibrated MLC model and film calibrated MLC model is .44 and .47, respectively; the p-value between those of the true composite beam dose verification is .62 and .36, respectively. Conclusion: It is confirmed that the 2-dimensional (2D) diode array MapCHECK2 can be used for data collection for MLC modeling with the combination of the ExpressMLC package of plans, whose doses are sufficient for the determination of MLC parameters. It could be a fitting alternative to films to boost the efficiency of MLC modeling and commissioning without sacrificing accuracy.


Subject(s)
Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage , Phantoms, Imaging , Gamma Rays , Radiotherapy, Intensity-Modulated/methods , Radiometry/methods
19.
J Appl Clin Med Phys ; 25(5): e14289, 2024 May.
Article in English | MEDLINE | ID: mdl-38319666

ABSTRACT

PURPOSE: To investigate the feasibility of commissioning the 16 MeV electron FLASH Extension (FLEX) in the commercial treatment planning system (TPS) for biomedical research with cell and mouse models, and in silico treatment planning studies. METHODS: To commission the FLEX system with the electron Monte Carlo (eMC) algorithm in the commercial TPS, radiochromic film was used to measure the vendor-recommended beam data. Once the beam model was generated for the eMC algorithm, supplemental measurements were collected for validation purposes and compared against the TPS-calculated results. Additionally, the newly commissioned 16 MeV FLASH beam was compared to the corresponding 16 MeV conventional electron beam. RESULTS: The eMC algorithm effectively modeled the FLEX system. The eMC-calculated PDDs and profiles for the 16 MeV electron FLASH beam agreed with measured values within 1%, on average, for 6 × 6 cm2 and 10 × 10 cm2 applicators. Flatness and symmetry deviated by less than 1%, while FWHM and penumbra agreed within 1 mm for both eMC-calculated and measured profiles. Additionally, the small field (i.e., 2-cm diameter cutout) that was measured for validation purposes agreed with TPS-calculated results within 1%, on average, for both the PDD and profiles. The FLASH and conventional dose rate 16 MeV electron beam were in agreement in regard to energy, but the profiles for larger field sizes began to deviate (>10 × 10 cm2) due to the forward-peaked nature of the FLASH beam. For cell irradiation experiments, the measured and eMC-calculated in-plane and cross-plane absolute dose profiles agreed within 1%, on average. CONCLUSIONS: The FLEX system was successfully commissioned in the commercial TPS using the eMC algorithm, which accurately modeled the forward-peaked nature of the FLASH beam. A commissioned TPS for FLASH will be useful for pre-clinical cell and animal studies, as well as in silico FLASH treatment planning studies for future clinical implementation.


Subject(s)
Algorithms , Electrons , Monte Carlo Method , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy Planning, Computer-Assisted/methods , Mice , Humans , Animals , Phantoms, Imaging , Radiotherapy, Intensity-Modulated/methods , Computer Simulation
20.
Phys Med Biol ; 69(4)2024 Feb 13.
Article in English | MEDLINE | ID: mdl-38052092

ABSTRACT

Objective. To demonstrate the potential of Monte Carlo (MC) to support the resource-intensive measurements that comprise the commissioning of the treatment planning system (TPS) of new proton therapy facilities.Approach. Beam models of a pencil beam scanning system (Varian ProBeam) were developed in GATE (v8.2), Eclipse proton convolution superposition algorithm (v16.1, Varian Medical Systems) and RayStation MC (v12.0.100.0, RaySearch Laboratories), using the beam commissioning data. All models were first benchmarked against the same commissioning data and validated on seven spread-out Bragg peak (SOBP) plans. Then, we explored the use of MC to optimise dose calculation parameters, fully understand the performance and limitations of TPS in homogeneous fields and support the development of patient-specific quality assurance (PSQA) processes. We compared the dose calculations of the TPSs against measurements (DDTPSvs.Meas.) or GATE (DDTPSvs.GATE) for an extensive set of plans of varying complexity. This included homogeneous plans with varying field-size, range, width, and range-shifters (RSs) (n= 46) and PSQA plans for different anatomical sites (n= 11).Main results. The three beam models showed good agreement against the commissioning data, and dose differences of 3.5% and 5% were found for SOBP plans without and with RSs, respectively. DDTPSvs.Meas.and DDTPSvs.GATEwere correlated in most scenarios. In homogeneous fields the Pearson's correlation coefficient was 0.92 and 0.68 for Eclipse and RayStation, respectively. The standard deviation of the differences between GATE and measurements (±0.5% for homogeneous and ±0.8% for PSQA plans) was applied as tolerance when comparing TPSs with GATE. 72% and 60% of the plans were within the GATE predicted dose difference for both TPSs, for homogeneous and PSQA cases, respectively.Significance. Developing and validating a MC beam model early on into the commissioning of new proton therapy facilities can support the validation of the TPS and facilitate comprehensive investigation of its capabilities and limitations.