Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 40
Filter
Add more filters










Publication year range
1.
Sensors (Basel) ; 24(10)2024 May 19.
Article in English | MEDLINE | ID: mdl-38794083

ABSTRACT

In this paper, a new sensor is proposed to efficiently gather crucial information on corrosion phenomena and their progression within steel components. Fabricated with plastic optical fibers (POF), the sensor can detect corrosion-induced physical changes in the appearance of monitoring points within the steel material. Additionally, the new sensor incorporates an innovative structure that efficiently utilizes bi-directional optical transmission in the POF, simplifying the installation procedure and reducing the total cost of the POF cables by as much as 50% when monitoring multiple points. Furthermore, an extremely compact dummy sensor with the length of 5 mm and a diameter of 2.2 mm for corrosion-depth detection was introduced, and its functionality was validated through experiments. This paper outlines the concept and fundamental structure of the proposed sensor; analyzes the results of various experiments; and discusses its effectiveness, prospects, and economic advantages.

2.
Polymers (Basel) ; 16(6)2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38543466

ABSTRACT

Conventional methods for pathogen detection in water rely on time-consuming enrichment steps followed by biochemical identification strategies, which require assay times ranging from 24 hours to a week. However, in recent years, significant efforts have been made to develop biosensing technologies enabling rapid and close-to-real-time detection of waterborne pathogens. In previous studies, we developed a plastic optical fiber (POF) immunosensor using an optoelectronic configuration consisting of a U-Shape probe connected to an LED and a photodetector. Bacterial detection was evaluated with the immunosensor immersed in a bacterial suspension in water with a known concentration. Here, we report on the sensitivity of a new optoelectronic configuration consisting of two POF U-shaped probes, one as the reference and the other as the immunosensor, for the detection of Escherichia coli. In addition, another methos of detection was tested where the sensors were calibrated in the air, before being immersed in a bacterial suspension and then read in the air. This modification improved sensor sensitivity and resulted in a faster detection time. After the immunocapture, the sensors were DAPI-stained and submitted to confocal microscopy. The histograms obtained confirmed that the responses of the immunosensors were due to the bacteria. This new sensor detected the presence of E. coli at 104 CFU/mL in less than 20 min. Currently, sub-20 min is faster than previous studies using fiber-optic based biosensors. We report on an inexpensive and faster detection technology when compared with conventional methods.

3.
Sensors (Basel) ; 24(3)2024 Jan 29.
Article in English | MEDLINE | ID: mdl-38339602

ABSTRACT

The timely and cost-effective identification of the onset of corrosion and its progress would be critical for effectively maintaining structural integrity. Consequently, a series of fundamental experiments were conducted to capture the corrosion process on a steel plate using a new type of plastic optical fiber (POF) sensor. Electrolytic corrosion experiments were performed on a 5 mm thick steel plate immersed in an aqueous solution. The POF sensor installed on the upper side of the plate and directed downward detected the upward progression of the corrosion zone that formed on the underside of the plate. The results showed that the POF sensors could detect the onset of the upward-progressing corrosion front as it passed the 1 and 2 mm marks related to the thickness of the corroded zone. The POF sensors were designed to optically identify corrosion; therefore, the data obtained by these sensors could be processed using a newly developed graphic application software for smartphones and also identified by the naked eye. This method offered an easy and cost-effective solution for verifying the corrosion state of structural components.

4.
Biomimetics (Basel) ; 8(8)2023 Nov 25.
Article in English | MEDLINE | ID: mdl-38132506

ABSTRACT

Robotic systems and the human body consist of numerous joint structures, all of which require precise angle adjustments. At present, encoder, strain gauge, and electrical resistance-based sensors are commonly used for angle measurement. However, these sensors have limitations when used in underwater or in environments with strong electromagnetic waves. Therefore, we have developed an angle sensor based on step-index profile plastic optical fiber (SI-POF), which is cost-effective and highly durable, in this study in order to overcome the limitations of existing angle measurement sensors. To this end, the amount of light loss according to the gab and angle changes that occur when the POF angle sensor is applied to the robot arm was experimentally measured, and based on the results, a simulation of the amount of light loss when the two losses occurred at the same time was conducted. In addition, the performance of the POF angle sensor was evaluated by measuring sensitivity and resolution, and comparative verification with a commonly used encoder was conducted to verify the reliability of sensors in extreme environments, such as those with electromagnetic fields and those that are underwater. Through this, the reliability and practicality of the POF angle sensor were confirmed. The results obtained in this study suggest that POF-based angle sensors can contribute to the development of the biomimetic robot industry as well as ordinary robots, especially in environments where existing sensors are difficult to apply, such as areas with underwater or electromagnetic interference (EMI).

5.
Sensors (Basel) ; 23(12)2023 Jun 13.
Article in English | MEDLINE | ID: mdl-37420716

ABSTRACT

In this work, Fe2O3 was investigated as a doping agent for poly(methyl methacrylate) (PMMA) in order to enhance the plasmonic effect in sensors based on D-shaped plastic optical fibers (POFs). The doping procedure consists of immerging a premanufactured POF sensor chip in an iron (III) solution, avoiding repolymerization and its related disadvantages. After treatment, a sputtering process was used to deposit a gold nanofilm on the doped PMMA in order to obtain the surface plasmon resonance (SPR). More specifically, the doping procedure increases the refractive index of the POF's PMMA in contact with the gold nanofilm, improving the SPR phenomena. The doping of the PMMA was characterized by different analyses in order to determine the effectiveness of the doping procedure. Moreover, experimental results obtained by exploiting different water-glycerin solutions have been used to test the different SPR responses. The achieved bulk sensitivities confirmed the improvement of the plasmonic phenomenon with respect to a similar sensor configuration based on a not-doped PMMA SPR-POF chip. Finally, doped and non-doped SPR-POF platforms were functionalized with a molecularly imprinted polymer (MIP), specific for the bovine serum albumin (BSA) detection, to obtain dose-response curves. These experimental results confirmed an increase in binding sensitivity for the doped PMMA sensor. Therefore, a lower limit of detection (LOD), equal to 0.04 µM, has been obtained in the case of the doped PMMA sensor when compared to the one calculated for the not-doped sensor configuration equal to about 0.09 µM.


Subject(s)
Plastics , Polymers , Polymethyl Methacrylate , Optical Fibers , Ferric Compounds , Surface Plasmon Resonance/methods , Gold
6.
Biosensors (Basel) ; 13(4)2023 Mar 29.
Article in English | MEDLINE | ID: mdl-37185507

ABSTRACT

In this work, a surface plasmon resonance (SPR) biosensor based on a spoon-shaped waveguide combined with an estrogen receptor (ERα) was developed and characterized for the detection and the quantification of estradiol in real water samples. The fabrication process for realizing the SPR platform required a single step consisting of metal deposition on the surface of a polystyrene spoon-shaped waveguide featuring a built-in measuring cell. The biosensor was achieved by functionalizing the bowl sensitive surface with a specific estrogen receptor (ERα) that was able to bind the estradiol. In a first phase, the biosensor tests were performed in a phosphate buffer solution obtaining a limit of detection (LOD) equal to 0.1 pM. Then, in order to evaluate the biosensor's response in different real matrices related to aquaculture, its performances were examined in seawater and freshwater. The experimental results support the possibility of using the ERα-based biosensor for the screening of estradiol in both matrices.


Subject(s)
Biosensing Techniques , Estradiol , Estrogen Receptor alpha , Receptors, Estrogen , Biosensing Techniques/methods , Surface Plasmon Resonance/methods
7.
Sensors (Basel) ; 23(6)2023 Mar 22.
Article in English | MEDLINE | ID: mdl-36992033

ABSTRACT

We report the design and testing of a sensor pad based on optical and flexible materials for the development of pressure monitoring devices. This project aims to create a flexible and low-cost pressure sensor based on a two-dimensional grid of plastic optical fibers embedded in a pad of flexible and stretchable polydimethylsiloxane (PDMS). The opposite ends of each fiber are connected to an LED and a photodiode, respectively, to excite and measure light intensity changes due to the local bending of the pressure points on the PDMS pad. Tests were performed in order to study the sensitivity and repeatability of the designed flexible pressure sensor.

8.
Anal Sci ; 38(12): 1549-1554, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36152169

ABSTRACT

Fiber optic sensors for monitoring scale deposition in geothermal brine and hot spring water should be safe, easily fabricated, and readily disposable. These desired features already have been enhanced in plastic optical fibers (POFs) and U-shaped sensors for other applications. The present work reports a U-shaped POF sensor for CaCO3 scale deposition. The sensors were easily fabricated by thermally bending the bulk POF without removing the cladding. At the bend, the percentage of total internal reflection between the water and the POF surface is affected by the high refractive index of the CaCO3 deposit. The optical responses of the U-shaped sensor to CaCO3 formation were investigated in a mixture of calcium chloride dehydrate and sodium hydrogen carbonate using a white-light source and a spectroscopic detector. The sensor was responsive to CaCO3 formation on the sensor surface and was especially sensitive at small bending radii. The sensitivity was further enhanced by increasing the number of bends. Finally, the U-shaped POF sensor was applied to the monitoring of CaCO3 scale deposition in hot spring water sampled at Matsushiro, Japan.


Subject(s)
Hot Springs , Optical Fibers , Plastics/chemistry , Water , Fiber Optic Technology
9.
Sensors (Basel) ; 22(16)2022 Aug 19.
Article in English | MEDLINE | ID: mdl-36015998

ABSTRACT

In this work, a simple side-polish plastic optical fiber (POF)-based surface plasmon resonance (SPR) sensor is proposed and demonstrated for simultaneous measurement of refractive index (RI) and liquid level. The effects of side-polish depths on the sensing performance were studied. The experimental results show that the SPR peak wavelength will be changed as the RI changes, and the SPR peak intensity will be changed with the liquid level variation. By monitoring the changes in peak wavelength and intensity, the RI and liquid level can be detected simultaneously. Experimental results show that an RI sensitivity of 2008.58 nm/RIU can be reached at an RI of 1.39. This sensor has the advantages of simple structure and low cost, which has a good prospect in the field of biochemical sensing.


Subject(s)
Refractometry , Surface Plasmon Resonance , Optical Fibers , Plastics , Poland , Surface Plasmon Resonance/methods
10.
Biosensors (Basel) ; 12(8)2022 Aug 12.
Article in English | MEDLINE | ID: mdl-36005031

ABSTRACT

An optical sensor for uranyl has been prepared based on a gold-plated D-shaped plastic optical fiber (POF) combined with a receptor consisting of a bifunctional synthetic molecule, 11-mercaptoundecylphosphonic acid (MUPA), with a phosphonic group for complexing the considered ion, and a sulfide moiety through which the molecule is fixed at the gold resonant surface as a molecular layer in an easy and reproducible way. The sensor is characterized by evaluating the response in function of the uranyl concentration in aqueous solutions of different compositions and real-life samples, such as tap water and seawater. The mechanism of the uranyl/MUPA interaction was investigated. Two different kinds of interactions of uranyl with the MUPA layer on gold from water are observed: a strong one and a weak one. In the presence of competing metal ions as Ca2+ and Mg2+, only the strong interaction takes place, with a high affinity constant (around 107 M-1), while a somewhat lower constant (i.e., around 106 M-1) is obtained in the presence of Mg2+ which forms stronger complexes with MUPA than Ca2+. Due to the high affinity and the good selectivity of the recognition element MUPA, a detection limit of a few µg L-1 is reached directly in natural water samples without any time-consuming sample pretreatment, making it possible for rapid, in situ controls of uranyl by the proposed sensor.


Subject(s)
Optical Fibers , Uranium , Gold , Ions , Seawater , Uranium/analysis , Water
11.
Sensors (Basel) ; 22(13)2022 Jul 04.
Article in English | MEDLINE | ID: mdl-35808529

ABSTRACT

The leakage current (LC) caused by the surface contamination of insulators, together with environmental variables, is one of the most basic online monitoring parameters for insulator status. However, the impact of weather conditions such as temperature, air humidity, and dew point on the LC has not been deeply studied until now. In this paper, based on meteorological data obtained online and LC obtained with an optical fiber sensor, installed in 500-kV insulator strings of a transmission line, the impact of weather conditions was studied. Results indicate that the LCs follow a specific pattern, according to weather conditions. The system has been continuously monitoring LC, humidity, temperature, and dew point uninterrupted for three years, sending the acquired data to a web page; therefore, it has been demonstrated to be robust, reliable, and repetitive. The sensor features the broadband response and acquisition capabilities of partial discharge pulses in high-voltage insulators, allowing the detection of high-frequency pulses. When comparing the LC measured in this work with those from other works, our measurements are substantially higher; this is due to the type of pollution found in this specific situation, which includes iron oxide powder, producing a conductive layer over the insulator surface that, unlike sea salt, does not depend on humidity to conduct an LC. One of the conclusions reached in this work is that partial discharge surges are caused when the local temperature reaches the dew point and not simply from the presence of high humidity, as stated in many works dealing with LCs. The monitored LC can be used as an indicative parameter of a possible flashover, enabling the proper planning of insulator predictive maintenance, either by jet-washing the surface or even changing the insulators when they are damaged.


Subject(s)
Meteorology , Weather , Humidity , Temperature
12.
Sensors (Basel) ; 22(10)2022 May 20.
Article in English | MEDLINE | ID: mdl-35632292

ABSTRACT

The proper measurement of plantar pressure during gait is critical for the clinical diagnosis of foot problems. Force platforms and wearable devices have been developed to study gait patterns during walking or running. However, these devices are often expensive, cumbersome, or have boundary constraints that limit the participant's motions. Recent advancements in the quality of plastic optical fiber (POF) have made it possible to manufacture a low-cost bend sensor with a novel design for use in plantar pressure monitoring. An intensity-based POF bend sensor is not only lightweight, non-invasive, and easy to construct, but it also produces a signal that requires almost no processing. In this work, we have designed, fabricated, and characterized a novel intensity POF sensor to detect the force applied by the human foot and measure the gait pattern. The sensors were put through a series of dynamic and static tests to determine their measurement range, sensitivity, and linearity, and their response was compared to that of two different commercial force sensors, including piezo resistive sensors and a clinical force platform. The results suggest that this novel POF bend sensor can be used in a wide range of applications, given its low cost and non-invasive nature. Feedback walking monitoring for ulcer prevention or sports performance could be just one of those applications.


Subject(s)
Optical Fibers , Polymers , Foot , Gait , Humans , Plastics , Walking
13.
Polymers (Basel) ; 13(22)2021 Nov 17.
Article in English | MEDLINE | ID: mdl-34833273

ABSTRACT

The bandwidth of multimode W-type plastic optical fibers (POFs) with graded-index (GI) core distribution is investigated by solving the time-dependent power flow equation. The multimode W-type GI POF is designed from a multimode single-clad (SC) GI POF fiber upon modification of the cladding layer of the latter. Results show how the bandwidth in W-type GI POFs can be enhanced by increasing the wavelength for different widths of the intermediate layer and refractive indices of the outer cladding. These fibers are characterized according to their apparent efficiency to reduce modal dispersion and increase bandwidth.

14.
Talanta ; 233: 122532, 2021 Oct 01.
Article in English | MEDLINE | ID: mdl-34215035

ABSTRACT

A specific aptameric sequence has been immobilized on short polyethyleneglycol (PEG) interface on gold nano-film deposited on a D-shaped plastic optical fiber (POFs) probe, and the protein binding has been monitored exploiting the very sensitive surface plasmon resonance (SPR) phenomenon. The receptor-binding domain (RBD) of the SARS-CoV-2 spike glycoprotein has been specifically used to develop an aptasensor. Surface analysis techniques coupled to fluorescence microscopy and plasmonic analysis have been utilized to characterize the biointerface. Spanning a wide protein range (25 ÷ 1000 nM), the SARS-Cov-2 spike protein was detected with a Limit of Detection (LoD) of about 37 nM. Different interferents (BSA, AH1N1 hemagglutinin protein and MERS spike protein) have been tested confirming the specificity of our aptasensor. Finally, a preliminary test in diluted human serum encouraged its application in a point-of-care device, since POF-based aptasensor represent a potentially low-cost compact biosensor, characterized by a rapid response, a small size and could be an ideal laboratory portable diagnostic tool.


Subject(s)
COVID-19 , Optical Fibers , Humans , Plastics , SARS-CoV-2 , Spike Glycoprotein, Coronavirus
15.
Biosensors (Basel) ; 11(3)2021 Mar 05.
Article in English | MEDLINE | ID: mdl-33807535

ABSTRACT

A surface plasmon resonance (SPR) platform, based on a D-shaped plastic optical fiber (POF), combined with a biomimetic receptor, i.e., a molecularly imprinted polymer (MIP), is proposed to detect furfural (2-furaldheide, 2-FAL) in fermented beverages like wine. MIPs have been demonstrated to be a very convenient biomimetic receptor in the proposed sensing device, being easy and rapid to develop, suitable for on-site determinations at low concentrations, and cheap. Moreover, the MIP film thickness can be changed to modulate the sensing parameters. The possibility of performing single drop measurements is a further favorable aspect for practical applications. For example, the use of an SPR-MIP sensor for the analysis of 2-FAL in a real life matrix such as wine is proposed, obtaining a low detection limit of 0.004 mg L-1. The determination of 2-FAL in fermented beverages is becoming a crucial task, mainly for the effects of the furanic compounds on the flavor of food and their toxic and carcinogenic effect on human beings.


Subject(s)
Furaldehyde/analysis , Wine/analysis , Humans , Molecular Imprinting , Molecularly Imprinted Polymers , Optical Fibers , Polymers , Surface Plasmon Resonance
16.
Sensors (Basel) ; 21(4)2021 Feb 22.
Article in English | MEDLINE | ID: mdl-33671630

ABSTRACT

An enhanced plastic optical fiber (POF)-based surface plasmon resonance (SPR) sensor is proposed by employing a double-sided polished structure. The sensor is fabricated by polishing two sides of the POF symmetrically along with the fiber axis, and a layer of Au film is deposited on each side of the polished region. The SPR can be excited on both polished surfaces with Au film coating, and the number of light reflections will be increased by using this structure. The simulation and experimental results show that the proposed sensor has an enhanced SPR effect. The visibility and full width at half maximum (FWHM) of spectrum can be improved for the high measured refractive index (RI). A sensitivity of 4284.8 nm/RIU is obtained for the double-sided POF-based SPR sensor when the measured liquid RI is 1.42. The proposed SPR sensor is easy fabrication and low cost, which can provide a larger measurement range and action area to the measured samples, and it has potential application prospects in the oil industry and biochemical sensing fields.

17.
Biotechnol Rep (Amst) ; 29: e00587, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33489788

ABSTRACT

This paper presents the development and feasibility tests of a cortisol immunosensor. The sensor is based on surface plasmon resonance (SPR) using an unclad plastic optical fiber (POF) in which the SPR is used as sensitivity enhancer, promoted by a gold/palladium (AuPd) alloy coating. The AuPd coated fibers were functionalized with an anti-cortisol antibody and passivated with bovine serum albumin (BSA) to be tested in the presence of cortisol as target analyte. The antibody-antigen binding reaction caused a variation of the refractive index on the surface of the AuPd coating, which leads to a shift of the SPR signature wavelength. The sensor was tested for different cortisol concentrations, ranging from 0.005 to 10 ng/mL. The reported biosensor presented a total wavelength shift of 15 nm for the testing range, putting in evidence a high sensitivity. Control tests for selectivity assessment were also performed. Concentrations as high as 10 ng/mL of cortisol, in a sensor functionalized with anti-hCG antibodies, only resulted in 1 nm variation of the resonance wavelength, 15 times lower than the one functionalized with the anti-cortisol antibodies, which indicates a high selectivity for the proposed approach. For this sensing approach the limit of detection (LOD) was determined to be 1 pg/mL. The proposed SPR based POF sensor has a low-cost interrogation method, high sensitivity and low LOD, straightforward signal processing and find important applications in different biological fields.

18.
Sensors (Basel) ; 20(18)2020 Sep 14.
Article in English | MEDLINE | ID: mdl-32937972

ABSTRACT

A U-shaped double-side polished plastic optical fiber (POF) is demonstrated as a liquid refractive index (RI) sensor. The refractive index of glycerinum solutions is identified by the intensity detection on the bending and evanescent wave loss change. Heat treatment and mechanical polishing are adopted to form the symmetrical side-polished POF probe. The processing parameters are experimentally optimized on the power transmittance. The sensitivity of 1541%/RIU (Refractive Index Unit) can be obtained with a resolution of 5.35 × 10-4 in the scope of 1.33-1.39. The favorable temperature characteristic is proved to offer stable RI sensing from 20 to 50 °C. This simple POF sensor has potentials in low-cost visible light intensity RI detection.

19.
Sensors (Basel) ; 20(18)2020 Sep 21.
Article in English | MEDLINE | ID: mdl-32967211

ABSTRACT

A plastic filament of poly (methyl methacrylate) (PMMA) was fabricated by extrusion. The mode confinement was simulated using numerical software. The idea is to study how the light intensity changes inside the plastic optical fiber (POF) when a bending in multiple directions is applied. The results obtained from the simulation were compared to the experimental observations. The non-circular shape of the POF allows sensing a rotation applied as well. The angle of rotation was obtained processing two images of the end facet of the fiber (one with the fiber in a reference position and one with the rotated fiber), using an intensity-based automatic image registration. The accuracy in the rotation calculation was of 0.01°.

20.
Sensors (Basel) ; 20(9)2020 Apr 28.
Article in English | MEDLINE | ID: mdl-32354099

ABSTRACT

Using either bulk or fiber optics the profile of laser beams can be altered from Gaussian to top-hat or hollow beams allowing enhanced performance in applications like laser cooling, optical trapping, and fiber sensing. Here, we report a method based on multimode Plastic Optical Fibers (POF) long-tapers, to tweak the beam profile from near Gaussian to a hollow beam, by generating surface irregularities on the conical sections of the taper with a heat-and-pull technique. Furthermore, a cutback technique applied on long tapers expanded the output beam profile by more than twice the numerical aperture (NA) of the fiber. The enhanced sensitivity and detection efficiency of the extended profile was tested on a fiber optical ice sensor related to aviation safety.

SELECTION OF CITATIONS
SEARCH DETAIL