Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 15.084
Filter
1.
eNeuro ; 11(7)2024 Jul.
Article in English | MEDLINE | ID: mdl-39025674

ABSTRACT

Quantifying and analyzing licking behavior can offer valuable insights into fundamental neurobiological mechanisms controlling animal consummatory behaviors. Lickometers are typically based on electrical properties, a strategy that comes with limitations, including susceptibility to electrical interference and generation of electrical disturbances in electrophysiological measurements. While optical lickometers offer an alternative method to measure licks and quantify fluid intake in animals, they are prone to false readings and susceptibility to outside light sources. To overcome this problem, we propose a low-cost open-source lickometer that combines a restricted infrared beam defined by optical fibers, with a poke design that allows easy access to the tongue while limiting access of other body parts and external light sources. This device also includes features for detecting nose pokes and presenting visual cues during behavioral tasks. We provide validation experiments that demonstrate the optical lickometer's reliability, high-sensitivity and precision, and its application in a behavioral task, showcasing the potential of this tool to study lick microstructure in combination with other techniques, such as imaging of neural activity, in freely moving mice.


Subject(s)
Optical Fibers , Animals , Mice , Drinking Behavior/physiology , Mice, Inbred C57BL , Male , Reproducibility of Results , Equipment Design , Fiber Optic Technology/methods , Fiber Optic Technology/instrumentation
2.
BMC Anesthesiol ; 24(1): 245, 2024 Jul 19.
Article in English | MEDLINE | ID: mdl-39030551

ABSTRACT

BACKGROUND: Fiberoptic-guided intubation is considered as "gold standard" of difficult airway management. Management of the airway in prone position in patients with severe trauma presenting with penetrating waist and hip injury poses a major challenge to the anesthesiologist. CASE PRESENTATION: A man presented with severe multiple trauma and hemorrhagic shock as a result of an industrial accident with several deformed steel bars penetrating the left lower waist and hip. It was decided to schedule an exploratory laparotomy following extracting the deformed steel bars. Successful administration of awake fiberoptic nasotracheal intubation, performed in a prone position under airway blocks and appropriate sedation, allowed for the procedure. The exploratory laparotomy revealed damage to multiple organs, which were repaired sequentially during a 7-hour surgical operation. The patient's recovery was uneventful, and he was discharged from the hospital one month after the surgery. CONCLUSIONS: Awake fiberoptic nasotracheal intubation, along with airway blocks and appropriate sedation, can be a viable option in patients with severe multiple trauma in the prone position.


Subject(s)
Fiber Optic Technology , Intubation, Intratracheal , Multiple Trauma , Humans , Male , Prone Position , Intubation, Intratracheal/methods , Multiple Trauma/surgery , Wakefulness , Adult , Shock, Hemorrhagic/etiology , Shock, Hemorrhagic/surgery , Shock, Hemorrhagic/therapy , Patient Positioning/methods
3.
Anal Chim Acta ; 1316: 342820, 2024 Aug 08.
Article in English | MEDLINE | ID: mdl-38969422

ABSTRACT

This research presents an innovative reflective fiber optic probe structure, mutinously designed to detect H7N9 avian influenza virus gene precisely. This innovative structure skillfully combines multimode fiber (MMF) with a thin-diameter seven-core photonic crystal fiber (SCF-PCF), forming a semi-open Fabry-Pérot (FPI) cavity. This structure has demonstrated exceptional sensitivity in light intensity-refractive index (RI) response through rigorous theoretical and experimental validation. The development of a quasi-distributed parallel sensor array, which provides temperature compensation during measurements, has achieved a remarkable RI response sensitivity of up to 532.7 dB/RIU. The probe-type fiber optic sensitive unit, expertly functionalized with streptavidin, offers high specificity in detecting H7N9 avian influenza virus gene, with an impressively low detection limit of 10-2 pM. The development of this biosensor marks a significant development in biological detection, offering a practical engineering solution for achieving high sensitivity and specificity in light-intensity-modulated biosensing. Its potential for wide-ranging applications in various fields is now well-established.


Subject(s)
Biosensing Techniques , Influenza A Virus, H7N9 Subtype , Temperature , Biosensing Techniques/methods , Influenza A Virus, H7N9 Subtype/genetics , Influenza A Virus, H7N9 Subtype/isolation & purification , Optical Fibers , Limit of Detection , Fiber Optic Technology/methods , Animals , Genes, Viral
4.
Opt Express ; 32(10): 17239-17254, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38858913

ABSTRACT

Doxorubicin (DOX) is an important drug for cancer treatment, but its clinical application is limited due to its toxicity and side effects. Therefore, detecting the concentration of DOX during treatment is crucial for enhancing efficacy and reducing side effects. In this study, the authors developed a biophotonic fiber sensor based on localized surface plasmon resonance (LSPR) with the multimode fiber (MMF)-four core fiber (FCF)-seven core fiber (SCF)-MMF-based direct-taper and anti-taper structures for the specific detection of DOX. Compared to other detection methods, it has the advantages of high sensitivity, low cost, and strong anti-interference ability. In this experiment, multi-walled carbon nanotubes (MWCNTs), cerium-oxide nanorods (CeO2-NRs), and gold nanoparticles (AuNPs) were immobilized on the probe surface to enhance the sensor's biocompatibility. MWCNTs and CeO2-NRs provided more binding sites for the fixation of AuNPs. By immobilizing AuNPs on the surface, the LSPR was stimulated by the evanescent field to detect DOX. The sensor surface was functionalized with DOX aptamers for specific detection, enhancing its specificity. The experiments demonstrated that within a linear detection range of 0-10 µM, the sensitivity of the sensor is 0.77 nm/µM, and the limit of detection (LoD) is 0.42 µM. Additionally, the probe's repeatability, reproducibility, stability, and selectivity were evaluated, indicating that the probe has high potential for detecting DOX during cancer treatment.


Subject(s)
Doxorubicin , Gold , Metal Nanoparticles , Surface Plasmon Resonance , Doxorubicin/pharmacology , Humans , Surface Plasmon Resonance/instrumentation , Gold/chemistry , Metal Nanoparticles/chemistry , Neoplasms/drug therapy , Nanotubes, Carbon/chemistry , Biosensing Techniques/instrumentation , Optical Fibers , Equipment Design , Antibiotics, Antineoplastic/analysis , Cerium/chemistry , Fiber Optic Technology/instrumentation
5.
Opt Express ; 32(11): 20024-20034, 2024 May 20.
Article in English | MEDLINE | ID: mdl-38859121

ABSTRACT

An optical fiber sensing probe using a composite sensitive film of polyacrylonitrile (PAN) nanofiber membrane and gold nanomembrane is presented for the detection of a carcinoembryonic antigen (CEA), a biomarker associated with colorectal cancer and other diseases. The probe is based on a tilted fiber Bragg grating (TFBG) with a surface plasmon resonance (SPR) gold nanomembrane and a functionalized polyacrylonitrile (PAN) PAN nanofiber coating that selectively binds to CEA molecules. The performance of the probe is evaluated by measuring the spectral shift of the TFBG resonances as a function of CEA concentration in buffer. The probe exhibits a sensitivity of 0.46 dB/(µg/ml), a low limit of detection of 505.4 ng/mL in buffer, and a good selectivity and reproducibility. The proposed probe offers a simple, cost-effective, and a novel method for CEA detection that can be potentially applied for clinical diagnosis and monitoring of CEA-related diseases.


Subject(s)
Acrylic Resins , Carcinoembryonic Antigen , Gold , Nanofibers , Optical Fibers , Surface Plasmon Resonance , Carcinoembryonic Antigen/analysis , Gold/chemistry , Nanofibers/chemistry , Surface Plasmon Resonance/instrumentation , Surface Plasmon Resonance/methods , Acrylic Resins/chemistry , Humans , Biosensing Techniques/instrumentation , Membranes, Artificial , Metal Nanoparticles/chemistry , Reproducibility of Results , Fiber Optic Technology/instrumentation
6.
Opt Express ; 32(8): 13783-13796, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38859339

ABSTRACT

The conical fiber SPR sensor is easy to manufacture and has been used in biochemical detection research, but it has the problem of structural fragility. This article proposes a spiral cone fiber SPR sensor, which introduces a spiral structure on the 76µm fiber coarse cone, achieving good coupling of the core mode into the cladding mode, and improving the physical strength and practicality of the cone-shaped fiber SPR sensor. By modifying the target protein on the surface of the sensor gold film, specific detection of ginsenoside Rg1, an active ingredient of traditional Chinese medicine ginseng, was achieved. The detection sensitivity was 0.138 nm/(µm/ml) and the detection limit was 0.22µm/ml. The proposed spiral cone fiber SPR sensor provides a new scheme for the specific detection of active ingredients in traditional Chinese medicine, which is structurally stable and physically strong.


Subject(s)
Ginsenosides , Surface Plasmon Resonance , Ginsenosides/analysis , Surface Plasmon Resonance/methods , Biosensing Techniques/instrumentation , Equipment Design , Fiber Optic Technology/instrumentation , Limit of Detection
7.
Urolithiasis ; 52(1): 92, 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38884642

ABSTRACT

The purpose of this review is to analyze the trend in optical features and flexibility changes of flexible ureteroscopes over the past decades, and determine the correlation of individual parameters with release period as well as with dimensional parameters. Flexible ureteroscopes mentioned in the literature or those commercially available were searched. To minimize the search bias, the instruments were grouped by release date time-periods of < 2000 year, 2000-2009, 2010-2019, and 2020 onwards. The final review included only those instrument models for which data on minimum and maximum depth of field, field of view, direction of view, and deflection degree had been determined. The correlation among features investigated as well as with release period was also determined. 61 models of flexible ureteroscopes (27 fibreoptic and 34 digital scopes) were included. Among the different features investigated among fiberoptic endoscopes, minimum depth of field positively and negatively correlated with channel size and field of view, respectively, whereas maximum depth of view and field of view positively correlated with overall shaft and deflection degree, respectively. Up and down deflection strongly correlated with each other and both were negatively proportional to the distal tip size. For the digital endoscopes, minimum depth of field negatively and positively correlated with distal tip size and working length, respectively. Maximum depth of field positively correlated with field of view, whereas the latter was negatively proportional to the overall shaft. As for the fiberoptic counterparts, up and down deflection strongly correlated with each other. Field of view, up and down deflection of fiberoptic flexible ureteroscopes, were significantly increased among fiberoptic and digital endoscopes over decades. As flexible ureteroscopy technology has evolved, there has been a trend towards increasing field of view with up and down deflection. Given the importance of scope ergonomics, one aspect of this popularity is the improvement of optical characteristics and deflection degree, which significantly correlates with the release period.


Subject(s)
Equipment Design , Ureteroscopes , Humans , Fiber Optic Technology , Kidney/diagnostic imaging , Kidney/surgery , Ureteroscopy/instrumentation , Ureteroscopy/trends
8.
Sensors (Basel) ; 24(11)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38894393

ABSTRACT

As the global aging population increases, the demand for rehabilitation of elderly hand conditions has attracted increased attention in the field of wearable sensors. Owing to their distinctive anti-electromagnetic interference properties, high sensitivity, and excellent biocompatibility, optical fiber sensors exhibit substantial potential for applications in monitoring finger movements, physiological parameters, and tactile responses during rehabilitation. This review provides a brief introduction to the principles and technologies of various fiber sensors, including the Fiber Bragg Grating sensor, self-luminescent stretchable optical fiber sensor, and optic fiber Fabry-Perot sensor. In addition, specific applications are discussed within the rehabilitation field. Furthermore, challenges inherent to current optical fiber sensing technology, such as enhancing the sensitivity and flexibility of the sensors, reducing their cost, and refining system integration, are also addressed. Due to technological developments and greater efforts by researchers, it is likely that wearable optical fiber sensors will become commercially available and extensively utilized for rehabilitation.


Subject(s)
Optical Fibers , Wearable Electronic Devices , Humans , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Fiber Optic Technology/instrumentation , Rehabilitation/instrumentation , Biosensing Techniques/instrumentation , Biosensing Techniques/methods
9.
BMC Anesthesiol ; 24(1): 197, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38834948

ABSTRACT

BACKGROUND: Ciprofol is a promising sedative. This study aims to explore the median effective dose (ED50) of ciprofol in inhibiting responses to fiberoptic bronchoscopy in patients with pulmonary tuberculosis (PTB) of different genders and ages when combined with 0.15 µg/kg sufentanil, and to evaluate its efficacy and safety, providing a reference for the rational use of ciprofol in clinical practice. METHODS: PTB patients who underwent bronchoscopy examination and treatment at The Third People's Hospital of Changzhou between May 2023 and June 2023 were selected and divided into four groups using a stratified random method. All patients received intravenous injection of 0.15 µg/kg sufentanil followed by injection of the test dose of ciprofol according to Dixon's up-and-down method. The initial dose of ciprofol in all four groups was 0.4 mg/kg, with an adjacent ratio of 1:1.1. The next patient received a 10% increase in the dose of ciprofol if the previous patient in the same group experienced positive reactions such as choking cough, frowning, and body movements during the endoscopy. Otherwise, it was judged as a negative reaction, and the next patient received a 10% decrease in the dose of ciprofol. The transition from a positive reaction to a negative reaction was defined as a turning point, and the study of the group was terminated when seven turning points occurred. Hemodynamic parameters, oxygen saturation and adverse reactions were recorded at different time points in all groups. The Probit regression analysis method was used to calculate the ED50 of ciprofol in the four groups and compare between the groups. RESULTS: The ED50 of ciprofol combined with 0.15 µg/kg sufentanil for bronchoscopy in the four groups were 0.465 mg/kg, 0.433 mg/kg, 0.420 mg/kg and 0.396 mg/kg, respectively. CONCLUSION: The ED50 of ciprofol used for fiberoptic bronchoscopy varied among PTB patients of different genders and ages. TRIAL REGISTRATION: The Chinese Clinical Trial Registry, ChiCTR2300071508, Registered on 17 May 2023.


Subject(s)
Bronchoscopy , Fiber Optic Technology , Sufentanil , Tuberculosis, Pulmonary , Humans , Male , Bronchoscopy/methods , Female , Middle Aged , Sufentanil/administration & dosage , Adult , Tuberculosis, Pulmonary/drug therapy , Dose-Response Relationship, Drug , Aged , Hypnotics and Sedatives/administration & dosage , Young Adult , Drug Therapy, Combination
10.
Comput Biol Med ; 178: 108694, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38870728

ABSTRACT

Telemedicine is an emerging development in the healthcare domain, where the Internet of Things (IoT) fiber optics technology assists telemedicine applications to improve overall digital healthcare performances for society. Telemedicine applications are bowel disease monitoring based on fiber optics laser endoscopy, gastrointestinal disease fiber optics lights, remote doctor-patient communication, and remote surgeries. However, many existing systems are not effective and their approaches based on deep reinforcement learning have not obtained optimal results. This paper presents the fiber optics IoT healthcare system based on deep reinforcement learning combinatorial constraint scheduling for hybrid telemedicine applications. In the proposed system, we propose the adaptive security deep q-learning network (ASDQN) algorithm methodology to execute all telemedicine applications under their given quality of services (deadline, latency, security, and resources) constraints. For the problem solution, we have exploited different fiber optics endoscopy datasets with images, video, and numeric data for telemedicine applications. The objective is to minimize the overall latency of telemedicine applications (e.g., local, communication, and edge nodes) and maximize the overall rewards during offloading and scheduling on different nodes. The simulation results show that ASDQN outperforms all telemedicine applications with their QoS and objectives compared to existing state action reward state (SARSA) and deep q-learning network (DQN) policy during execution and scheduling on different nodes.


Subject(s)
Deep Learning , Internet of Things , Telemedicine , Humans , Fiber Optic Technology , Algorithms
11.
Biosens Bioelectron ; 261: 116521, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-38917514

ABSTRACT

Oceanic facilities and equipment corrosion present considerable economic and safety concerns, predominantly due to microbial corrosion. Early detection of corrosive microbes is pivotal for effective monitoring and prevention. Yet, traditional detection methods often lack specificity, require extensive processing time, and yield inaccurate results. Hence, the need for an efficient real-time corrosive microbe monitoring technology is evident. Pseudomonas aeruginosa, a widely distributed microorganism in aquatic environments, utilizes its production of quinone-like compounds, specifically pyocyanin (PYO), to corrode metals. Here, we report a novel fiber optic surface plasmon resonance (SPR) sensor modified by the C-terminal of BrlR protein (BrlR-C), which is a specific receptor of PYO molecule, to detect P. aeruginosa in aquatic environments. The results showed that the sensor had a good ability to recognize PYO in the concentration range of 0-1 µg/mL, and showed excellent sensing performance in real-time monitoring the growth status of P. aeruginosa. With a strong selectivity of PYO, the sensor could clearly detect P. aeruginosa against other bacteria in seawater environment, and exhibited excellent anti-interference ability against variations in pH, temperature and pressure and other interfering substances. This study provides a useful tool for monitoring corrosive P. aeruginosa biofilm in aquatic environments, which is a first of its kind example that serves as a laboratory model for the application of fiber optic technology in real-world scenarios to monitoring biofilms in microbial corrosion and biofouling.


Subject(s)
Biofilms , Biosensing Techniques , Fiber Optic Technology , Pseudomonas aeruginosa , Pyocyanine , Surface Plasmon Resonance , Pseudomonas aeruginosa/isolation & purification , Surface Plasmon Resonance/methods , Pyocyanine/analysis , Pyocyanine/chemistry , Biosensing Techniques/methods , Corrosion , Optical Fibers , Seawater/microbiology , Seawater/chemistry , Equipment Design
12.
ACS Sens ; 9(6): 3027-3036, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38864606

ABSTRACT

Surface plasmon (SP) excitation in metal-coated tilted fiber Bragg gratings (TFBGs) has been a focal point for highly sensitive surface biosensing. Previous efforts focused on uniform metal layer deposition around the TFBG cross section and temperature self-compensation with the Bragg mode, requiring both careful control of the core-guided light polarization and interrogation over most of the C + L bands. To circumvent these two important practical limitations, we studied and developed an original platform based on partially coated TFBGs. The partial metal layer enables the generation of dual-comb resonances, encompassing highly sensitive (TM/EH mode families) and highly insensitive (TE/HE mode families) components in unpolarized transmission spectra. The interleaved comb of insensitive modes acts as wavelength and power references within the same spectral region as the SP-active modes. Despite reduced fabrication and measurement complexity, refractometric accuracy is not compromised through statistical averaging over seven individual resonances within a narrowband window of 10 nm. Consequently, measuring spectra over 60 nm is no longer needed to compensate for small temperature or power fluctuations. This sensing platform brings the following important practical assets: (1) a simpler fabrication process, (2) no need for polarization control, (3) limited bandwidth interrogation, and (4) maintained refractometric accuracy, which makes it a true game changer in the ever-growing plasmonic sensing domain.


Subject(s)
Optical Fibers , Surface Plasmon Resonance , Surface Plasmon Resonance/instrumentation , Surface Plasmon Resonance/methods , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Fiber Optic Technology/instrumentation
13.
STAR Protoc ; 5(2): 103131, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38875116

ABSTRACT

To exclude the influence of motion on in vivo calcium imaging, animals usually need to be fixed. However, the whole-body restraint can cause stress in animals, affecting experimental results. In addition, some brain regions are prone to bleeding during surgery, which lowers the success rate of calcium imaging. Here, we present a protocol for calcium imaging using heparin-treated fiber in head-fixed mice. We describe steps for stereotaxic surgery, including virus injection and optic fiber implantation, fiber photometry, and data analysis. For complete details on the use and execution of this protocol, please refer to Du et al.1.


Subject(s)
Brain , Photometry , Animals , Mice , Photometry/methods , Brain/diagnostic imaging , Optical Fibers , Calcium/metabolism , Calcium/analysis , Stereotaxic Techniques , Fiber Optic Technology/methods
14.
Acta Otorhinolaryngol Ital ; 44(3): 183-191, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38859795

ABSTRACT

Objective: The aims of this study was to analyse fibreoptic endoscopic evaluation of swallowing (FEES) findings in tube-fed patients with coronavirus disease 2019 (COVID-19). Methods: Seventeen patients who had been intubated during intensive care unit (ICU) stay were enrolled. Pooling of secretions, dysphagia phenotype, penetration/aspiration and residue after swallow were assessed through FEES. The Functional Oral Intake Scale (FOIS) scores were also collected. Patients with significant swallowing impairment were evaluated again after 2 weeks. Results: All patients were tube-fed at enrollment. According to the FEES results, 7 started total oral feeding with at least one consistency. The more common dysphagia phenotypes were propulsive deficit and delayed pharyngeal phase. Pooling of secretions, penetration/aspiration, and residue after swallow were frequently documented. A significant improvement in FOIS scores was found during the second FEES examination. Conclusions: Swallowing impairment in patients with severe COVID-19 after discharge from the ICU is characterised by propulsive deficit and delayed pharyngeal phase. Most of these patients required feeding restrictions even if feeding abilities seem to improve over time.


Subject(s)
COVID-19 , Deglutition Disorders , Humans , COVID-19/complications , Deglutition Disorders/etiology , Deglutition Disorders/diagnosis , Deglutition Disorders/physiopathology , Male , Female , Middle Aged , Aged , Airway Extubation , Intensive Care Units , Enteral Nutrition/economics , Fiber Optic Technology , Aged, 80 and over , Endoscopy , Adult
15.
Lasers Surg Med ; 56(6): 597-605, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38923545

ABSTRACT

OBJECTIVES: A fast, simple, versatile, and reliable method to record light emission intensity profiles of cylindrical light diffusers (CDFs) in air and transparent liquids has been developed. METHODS: A fluorescent color glass filter (RG695) converts red light emitted by a cylindrical diffuser fiber into near-infrared light in an emission angle-independent manner. The red light was provided from a diode laser system at 635 nm. Near-infrared fluorescence from the RG695 was imaged with a camera. Images from this camera were processed to obtain emission intensity profiles. Cylindrical diffuser fiber profiles of four different manufacturers were compared. RESULTS: The proposed method provides angle-independent intensity profiles of cylindrical diffuser fibers with a single camera shot. It could be demonstrated that dependent on the underlying principle of how the diffuser fiber tips emit light, the emission profile can change significantly in media with different refractive indices. CONCLUSIONS: By converting the light emitted by a diffuser fiber tip into fluorescence light one can eliminate the dependence of the recorded profile on the emission angle from the diffusor. This approach allows for easily taking into account refraction-index (mis)matching by placing the equipment into a suitable liquid. The proposed measurement principle bears potential for quality assurance measurements of CDFs used for interstitial laser thermotherapy or photodynamic therapy.


Subject(s)
Equipment Design , Lasers, Semiconductor/therapeutic use , Fluorescence , Optical Fibers , Fiber Optic Technology/instrumentation
16.
Int J Pediatr Otorhinolaryngol ; 181: 111983, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38796943

ABSTRACT

OBJECTIVES: The systematic review aimed to provide an overview of the state-of-art regarding the use of fiberoptic endoscopic evaluation of swallowing (FEES) in pediatrics, specifically investigating FEES feasibility, safety, diagnostic accuracy, and protocols. METHODS: Four electronic databases were searched for original studies on the pediatric population that instrumentally assessed swallowing function using FEES. A hand-search of the references of included studies was performed. Data on the population, feasibility of endoscope insertion and bolus trials, adverse events, sensitivity and specificity, and FEES equipment and protocol were extracted. The quality of the studies was assessed using the checklists of the Johanna Briggs Institute. Selection of the studies, data extraction, and quality appraisal were conducted by two independent researchers. RESULTS: Eighty-two reports from 81 studies were included. The mean overall quality of the studies was 80 % (17-100 %). The feasibility of endoscope insertion was high (89%-100 %), while the feasibility of bolus trials varied from 40 % to 100 %. Adverse events were excessive crying (8 studies), irritability or agitation (4 studies), transitory oxygen desaturations (3 studies, 1.2-6.7 % of the patients), epistaxis (3 studies, 0.8-3.3 % of the patients), increased heart rate (1 study, 1 patient), vomiting (1 study, 1 patient), hypertonia (1 study), and hypersalivation (1 study). No major complications were reported. Using VFSS as the reference standard, FEES was generally found to be less sensitive (25-94 %) but more specific (75-100 %) for aspiration, whereas the reverse was true for penetration (sensitivity 76-100 %, specificity 44-83 %). FEES protocols were highly heterogeneous with poor reporting. CONCLUSION: FEES is a safe, accurate, and generally feasible examination in the pediatric population with suspected dysphagia. However, a consensus on the best FEES protocol for clinical practice and research is currently lacking.


Subject(s)
Deglutition Disorders , Deglutition , Fiber Optic Technology , Humans , Deglutition Disorders/diagnosis , Child , Deglutition/physiology , Endoscopy/methods , Child, Preschool , Infant , Pediatrics/methods , Sensitivity and Specificity
17.
Anal Chim Acta ; 1309: 342665, 2024 Jun 22.
Article in English | MEDLINE | ID: mdl-38772653

ABSTRACT

BACKGROUND: The concentration of cytochrome C is demonstrated to be an effective indicator of the microbial corrosion strength of metals. Traditional cytochrome C sensor can detect cytochrome C with a low detection limit, but their use is limited by their high cost, cumbersome operation, and susceptibility to malignant environments. In addition, studies on the monitoring of cytochrome C in the field of microbial corrosion has still not been carried out. Therefore, there is a need for a highly sensitive, selective, low-cost, anti-interference, and stable cytochrome C sensor with online monitoring and remote sensing capabilities for in-situ measurement of microbial corrosion strength. RESULTS: This paper proposed a highly sensitive label-free fiber-optic sensor based on Mach-Zehnder interferometer (MZI) for in-situ measurement of the microbial corrosion marker cytochrome C. Two-dimensional Ti2C-MXene material is uniformly immobilized onto the surface of the sensing area to improve the sensitivity, hydrophilicity, and specific surface area of the sensing area, as well as to facilitate the immobilization of specific sensitive materials. The cytochrome C antibody is modified on the surface of Ti2C-MXene to specifically recognize cytochrome C, whose concentration variation can be measured by monitoring the spectral shift of MZI sensor. Results demonstrate a measurement sensitivity of 1.428 nm/µM for cytochrome C concentrations ranging from 0 to 7.04 µM. The detection limit of the sensor is calculated to be 0.392 µM with remarkable performance, including selectivity, stability, and reliability. Besides, the measurement result of the proposed sensor in real microbial corrosive environment is consistent with that of the ideal environment. SIGNIFICANCE AND NOVELTY: This is the first instance of achieving in-situ and label-free measurement of cytochrome C by using a fiber-optic MZI sensor, which undoubtedly provides a feasible solution for the effective monitoring of microbial metal corrosion in the environment.


Subject(s)
Cytochromes c , Fiber Optic Technology , Interferometry , Titanium , Cytochromes c/analysis , Cytochromes c/metabolism , Titanium/chemistry , Biosensing Techniques/methods , Limit of Detection , Optical Fibers , Corrosion
18.
IEEE Trans Nanobioscience ; 23(3): 403-409, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38722715

ABSTRACT

A fiber-optic urea sensor based on surface plasmon resonance (SPR) and Mach-Zehnder interference (MZI) combined principle was designed and implemented. By plating gold film on the single-mode-no-core-thin-core-single-mode fiber structure, we successfully excited both SPR and MZI, and constructed two parallel detection channels for simultaneously measurement of urea concentration and temperature. Urease was immobilized on the gold film by metal-organic zeolite skeleton (ZIF-8), which can not only fix a large number of urease to improve measurement sensitivity of urea, but also protect urease activity to ensure the sensor stability. Experimental results indicate that the designed urea sensor with temperature compensation function can detect urea solution with concentration of 1-9 mM, and the sensitivity is 1.4 nm/mM. The proposed measurement method provides a new choice for monitoring urea concentration in the field of medical diagnosis and human health monitoring.


Subject(s)
Fiber Optic Technology , Surface Plasmon Resonance , Urea , Urease , Urea/chemistry , Urea/analysis , Surface Plasmon Resonance/methods , Surface Plasmon Resonance/instrumentation , Urease/chemistry , Fiber Optic Technology/instrumentation , Fiber Optic Technology/methods , Equipment Design , Gold/chemistry , Enzymes, Immobilized/chemistry , Interferometry/methods , Interferometry/instrumentation
19.
Kurume Med J ; 70(1.2): 73-75, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38763739

ABSTRACT

In general anesthesia for Klippel-Feil syndrome (KFS) patients, there is a potential risk of difficult intubation. However, airway assessment to predict difficult intubation for KFS patients is not known. In Patient 1, cervical spine computed tomography (CT) revealed airway compression due to cervical fusion. For airway assessment, bronchofiberscopy, three-dimensional (3-D) CT, and virtual bronchoscopic image (VBI) construction were performed. Based on these images, fiberoptic nasotracheal awake intubation was performed. In Patient 2, magnetic resonance imaging and bronchofiberscopy showed no airway compression due to cervical fusion; therefore, tracheal intubation was performed using a video laryngoscope after anesthetic administration. Airway compression due to cervical fusion is considered one of the risk factors for difficult intubation in KFS patients.


Subject(s)
Cervical Vertebrae , Intubation, Intratracheal , Klippel-Feil Syndrome , Tomography, X-Ray Computed , Humans , Klippel-Feil Syndrome/complications , Cervical Vertebrae/surgery , Cervical Vertebrae/diagnostic imaging , Male , Bronchoscopy , Female , Magnetic Resonance Imaging , Adult , Imaging, Three-Dimensional , Airway Obstruction/etiology , Airway Obstruction/surgery , Airway Obstruction/diagnostic imaging , Fiber Optic Technology , Anesthesia, General , Laryngoscopy , Middle Aged
20.
AANA J ; 92(3): 197-205, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38758714

ABSTRACT

Supraglottic airway (SGA) is an alternative to endotracheal intubation, however endotracheal intubation is often essential. One method to convert from an SGA to an endotracheal tube (ETT) is utilizing the SGA as a conduit for fiberoptic-guided advancement of an Aintree catheter (airway exchange catheter), and exchange of the SGA for an ETT. In this prospective randomized study, we compared two SGA devices in facilitating this exchange. Subjects were randomized to receive either the i-gel® or LMA® Supreme™ SGA. The SGA was placed and an Aintree intubation catheter was inserted through the SGA over a fiberoptic bronchoscope. Next, the SGA was removed, leaving the Aintree within the trachea, and an ETT was placed over the Aintree catheter and advanced into the trachea. The i-gel group exhibited shorter time to successful intubation (median, 191 vs. 434 seconds; P = .002). The i-gel group also had fewer study subjects requiring more than one attempt for successful Aintree placement (33% vs. 75%, P = .02). The i-gel group showed superior laryngeal view score (LVS) (6 vs. 4; P = .003). The i-gel SGA achieved a faster time to successful intubation, higher rate of first attempt Aintree placement, and superior LVS.


Subject(s)
Fiber Optic Technology , Intubation, Intratracheal , Laryngeal Masks , Humans , Intubation, Intratracheal/instrumentation , Intubation, Intratracheal/methods , Male , Prospective Studies , Female , Middle Aged , Adult , Nurse Anesthetists , Aged
SELECTION OF CITATIONS
SEARCH DETAIL