Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Vis Exp ; (137)2018 07 27.
Article in English | MEDLINE | ID: mdl-30102271

ABSTRACT

Due to recent technological progress, cryo-electron microscopy (cryo-EM) is rapidly becoming a standard method for the structural analysis of protein complexes to atomic resolution. However, protein isolation techniques and sample preparation methods for EM remain a bottleneck. A relatively small number (100,000 to a few million) of individual protein particles need to be imaged for the high-resolution analysis of proteins by the single particle EM approach, making miniaturized sample handling techniques and microfluidic principles feasible. A miniaturized, paper-blotting-free EM grid preparation method for sample pre-conditioning, EM grid priming and post processing that only consumes nanoliter-volumes of sample is presented. The method uses a dispensing system with sub-nanoliter precision to control liquid uptake and EM grid priming, a platform to control the grid temperature thereby determining the relative humidity above the EM grid, and a pick-and-plunge-mechanism for sample vitrification. For cryo-EM, an EM grid is placed on the temperature-controlled stage and the sample is aspirated into a capillary. The capillary tip is positioned in proximity to the grid surface, the grid is loaded with the sample and excess is re-aspirated into the microcapillary. Subsequently, the sample film is stabilized and slightly thinned by controlled water evaporation regulated by the offset of the platform temperature relative to the dew-point. At a given point the pick-and-plunge mechanism is triggered, rapidly transferring the primed EM grid into liquid ethane for sample vitrification. Alternatively, sample-conditioning methods are available to prepare nanoliter-sized sample volumes for negative stain (NS) EM. The methodologies greatly reduce sample consumption and avoid approaches potentially harmful to proteins, such as the filter paper blotting used in conventional methods. Furthermore, the minuscule amount of sample required allows novel experimental strategies, such as fast sample conditioning, combination with single-cell lysis for "visual proteomics," or "lossless" total sample preparation for quantitative analysis of complex samples.


Subject(s)
Microfluidics/methods , Microscopy, Electron, Transmission/methods , Proteomics/methods , Single-Cell Analysis/methods , Humans
2.
Proteomics ; 18(5-6): e1700176, 2018 03.
Article in English | MEDLINE | ID: mdl-29441686

ABSTRACT

This review compares and discusses conventional versus miniaturized specimen preparation methods for transmission electron microscopy (TEM). The progress brought by direct electron detector cameras, software developments and automation have transformed transmission cryo-electron microscopy (cryo-EM) and made it an invaluable high-resolution structural analysis tool. In contrast, EM specimen preparation has seen very little progress in the last decades and is now one of the main bottlenecks in cryo-EM. Here, we discuss the challenges faced by specimen preparation for single particle EM, highlight current developments, and show the opportunities resulting from the advanced miniaturized and microfluidic sample grid preparation methods described, such as visual proteomics and time-resolved cryo-EM studies.


Subject(s)
Cryoelectron Microscopy/methods , Imaging, Three-Dimensional/methods , Microscopy, Electron, Transmission/methods , Proteins/ultrastructure , Proteomics/methods , Humans , Microfluidics/methods , Specimen Handling
3.
J Struct Biol ; 197(3): 220-226, 2017 03.
Article in English | MEDLINE | ID: mdl-27864160

ABSTRACT

We present a sample preparation method for cryo-electron microscopy (cryo-EM) that requires only 3-20nL of sample to prepare a cryo-EM grid, depending on the protocol used. The sample is applied and spread on the grid by a microcapillary. The procedure does not involve any blotting steps, and real-time monitoring allows the water film thickness to be assessed and decreased to an optimum value prior to vitrification. We demonstrate that the method is suitable for high-resolution cryo-EM and will enable alternative electron microscopy approaches, such as single-cell visual proteomics.


Subject(s)
Cryoelectron Microscopy/methods , Proteins/ultrastructure , Cell Extracts , Microfluidics , Specimen Handling
4.
ACS Nano ; 10(5): 4981-8, 2016 05 24.
Article in English | MEDLINE | ID: mdl-27074622

ABSTRACT

Electron microscopy (EM) entered a new era with the emergence of direct electron detectors and new nanocrystal electron diffraction methods. However, sample preparation techniques have not progressed and still suffer from extensive blotting steps leading to a massive loss of sample. Here, we present a simple but versatile method for the almost lossless sample conditioning and preparation of nanoliter volumes of biological samples for EM, keeping the sample under close to physiological condition. A microcapillary is used to aspirate 3-5 nL of sample. The microcapillary tip is immersed into a reservoir of negative stain or trehalose, where the sample becomes conditioned by diffusive exchange of salt and heavy metal ions or sugar molecules, respectively, before it is deposited as a small spot onto an EM grid. We demonstrate the use of the method to prepare protein particles for imaging by transmission EM and nanocrystals for analysis by electron diffraction. Furthermore, the minute sample volume required for this method enables alternative strategies for biological experiments, such as the analysis of the content of a single cell by visual proteomics, fully exploiting the single molecule detection limit of EM.

5.
J Struct Biol ; 183(3): 467-473, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23816812

ABSTRACT

The stochastic nature of biological systems makes the study of individual cells a necessity in systems biology. Yet, handling and disruption of single cells and the analysis of the relatively low concentrations of their protein components still challenges available techniques. Transmission electron microscopy (TEM) allows for the analysis of proteins at the single-molecule level. Here, we present a system for single-cell lysis under light microscopy observation, followed by rapid uptake of the cell lysate. Eukaryotic cells were grown on conductively coated glass slides and observed by light microscopy. A custom-designed microcapillary electrode was used to target and lyse individual cells with electrical pulses. Nanoliter volumes were subsequently aspirated into the microcapillary and dispensed onto an electron microscopy grid for TEM inspection. We show, that the cell lysis and preparation method conserves protein structures well and is suitable for visual analysis by TEM.


Subject(s)
Single-Cell Analysis/methods , Animals , Cell Line , Cricetinae , Fibroblasts/metabolism , Fibroblasts/ultrastructure , Microscopy, Electron, Transmission , Organelles/ultrastructure
6.
J Struct Biol ; 177(1): 128-34, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22094535

ABSTRACT

A versatile methodology for electron microscopy (EM) grid preparation enabling total content sample analysis is presented. A microfluidic-dialysis conditioning module to desalt or mix samples with negative stain solution is used, combined with a robotic writing table to micro-pattern the EM grids. The method allows heterogeneous samples of minute volumes to be processed at physiological pH for structure and mass analysis, and allows the preparation characteristics to be finely tuned.


Subject(s)
Microfluidics/instrumentation , Microscopy, Electron, Scanning Transmission/methods , Animals , Cells, Cultured , Cricetinae , Staining and Labeling , Systems Biology/methods
SELECTION OF CITATIONS
SEARCH DETAIL