1.
ACS Sens ; 8(12): 4782-4791, 2023 Dec 22.
Article in English | MEDLINE | ID: mdl-37978286

ABSTRACT

Electrochemiluminescence (ECL) is an optical readout technique that is successfully applied for the detection of biomarkers in body fluids using microbead-based immunoassays. This technology is of utmost importance for in vitro diagnostics and thus a very active research area but is mainly focused on the quest for new dyes and coreactants, whereas the investigation of the ECL optics is extremely scarce. Herein, we report the 3D imaging of the ECL signals recorded at single microbeads decorated with the ECL labels in the sandwich immunoassay format. We show that the optical effects due to the light propagation through the bead determine mainly the spatial distribution of the recorded ECL signals. Indeed, the optical simulations based on the discrete dipole approximation compute rigorously the electromagnetic scattering of the ECL emission by the microbead and allow for reconstructing the spatial map of ECL emission. Thus, it provides a global description of the ECL chemical reactivity and the associated optics. The outcomes of this 3D imaging approach complemented by the optical modeling provide insight into the ECL optics and the unique ECL chemical mechanism operating on bead-based immunoassays. Therefore, it opens new directions for mechanistic investigations, ultrasensitive ECL bioassays, and imaging.


Subject(s)
Electrochemical Techniques , Luminescent Measurements , Luminescent Measurements/methods , Electrochemical Techniques/methods , Photometry , Coloring Agents , Immunoassay/methods
2.
Biophys J ; 122(15): 3159-3172, 2023 08 08.
Article in English | MEDLINE | ID: mdl-37393431

ABSTRACT

Quantitative phase microscopy (QPM) represents a noninvasive alternative to fluorescence microscopy for cell observation with high contrast and for the quantitative measurement of dry mass (DM) and growth rate at the single-cell level. While DM measurements using QPM have been widely conducted on mammalian cells, bacteria have been less investigated, presumably due to the high resolution and high sensitivity required by their smaller size. This article demonstrates the use of cross-grating wavefront microscopy, a high-resolution and high-sensitivity QPM, for accurate DM measurement and monitoring of single microorganisms (bacteria and archaea). The article covers strategies for overcoming light diffraction and sample focusing, and introduces the concepts of normalized optical volume and optical polarizability (OP) to gain additional information beyond DM. The algorithms for DM, optical volume, and OP measurements are illustrated through two case studies: monitoring DM evolution in a microscale colony-forming unit as a function of temperature, and using OP as a potential species-specific signature.


Subject(s)
Algorithms , Photometry , Animals , Microscopy, Fluorescence , Bacteria , Mammals
3.
J Opt Soc Am A Opt Image Sci Vis ; 39(8): 1462-1467, 2022 Aug 01.
Article in English | MEDLINE | ID: mdl-36215591

ABSTRACT

Replacing Maxwell equations by a scalar wave equation is often used in computational imaging to simulate the light-sample interaction. It significantly reduces the computational burden but provides field maps that are insensitive to the polarization of the incident field, provided the latter is constant throughout the sample. Here, we develop a scalar approximation that accounts for the polarization of the incident field. Comparisons with rigorous simulations show that this approach is more accurate than the classical scalar approximation with similar computational cost.

4.
Nat Mater ; 21(3): 269-271, 2022 03.
Article in English | MEDLINE | ID: mdl-35241822
5.
Opt Lett ; 45(13): 3721-3724, 2020 Jul 01.
Article in English | MEDLINE | ID: mdl-32630938

ABSTRACT

Biomedical imaging lacks label-free microscopy techniques able to reconstruct the contour of biological cells in solution, in 3D and with high resolution, as required for the fast diagnosis of numerous diseases. Inspired by computational optical coherence tomography techniques, we present a tomographic diffractive microscope in reflection geometry used as a synthetic confocal microscope, compatible with this goal and validated with the 3D reconstruction of a human effector T lymphocyte.


Subject(s)
Imaging, Three-Dimensional , Microscopy, Confocal/methods , T-Lymphocytes/cytology , Humans , Optical Phenomena
6.
Biomed Opt Express ; 11(2): 911-926, 2020 Feb 01.
Article in English | MEDLINE | ID: mdl-32206398

ABSTRACT

Reflection phase imaging provides label-free, high-resolution characterization of biological samples, typically using interferometric-based techniques. Here, we investigate reflection phase microscopy from intensity-only measurements under diverse illumination. We evaluate the forward and inverse scattering model based on the first Born approximation for imaging scattering objects above a glass slide. Under this design, the measured field combines linear forward-scattering and height-dependent nonlinear back-scattering from the object that complicates object phase recovery. Using only the forward-scattering, we derive a linear inverse scattering model and evaluate this model's validity range in simulation and experiment using a standard reflection microscope modified with a programmable light source. Our method provides enhanced contrast of thin, weakly scattering samples that complement transmission techniques. This model provides a promising development for creating simplified intensity-based reflection quantitative phase imaging systems easily adoptable for biological research.

7.
J Opt Soc Am A Opt Image Sci Vis ; 36(12): 2025-2029, 2019 Dec 01.
Article in English | MEDLINE | ID: mdl-31873375

ABSTRACT

The standard two-dimensional (2D) image recorded in bright-field fluorescence microscopy is rigorously modeled by a convolution process involving a three-dimensional (3D) sample and a 3D point spread function. We show on synthetic and experimental data that deconvolving the 2D image using the appropriate 3D point spread function reduces the contribution of the out-of-focus fluorescence, resulting in a better image contrast and resolution. This approach is particularly interesting for superresolution speckle microscopy, in which the resolution gain stems directly from the efficiency of the deconvolution of each speckle image.

8.
J Opt Soc Am A Opt Image Sci Vis ; 36(11): C1-C8, 2019 Nov 01.
Article in English | MEDLINE | ID: mdl-31873684

ABSTRACT

Estimating three-dimensional complex permittivity of a sample from the intensity recorded at the image plane of a microscope for various angles of illumination, as in optical Fourier ptychography microscopy, permits one to avoid the interferometric measurements of classical tomographic diffraction microscopes (TDMs). In this work, we present a general inversion scheme for processing intensities that can be applied to any microscope configuration (transmission or reflection, low or high numerical aperture), scattering regime (single or multiple scattering), or sample-holder geometries (with or without substrate). The inversion procedure is tested on a wide variety of synthetic experiments, and the reconstructions are compared to that of TDMs. In most cases, phaseless data yield the same result as complex data, thus paving the way toward a drastic simplification of TDM implementation.

9.
Opt Express ; 27(16): 23497-23514, 2019 Aug 05.
Article in English | MEDLINE | ID: mdl-31510626

ABSTRACT

We present a theoretical and numerical study of coherent anti-Stokes Raman scattering Fourier ptychography microscopy (CARS-FPM), a scheme that has not been considered so far in the previously reported CARS wide-field imaging schemes. In this approach, the distribution of the Raman scatterer density of the sample is reconstructed numerically from CARS images obtained under various angles of incidences of the pump or Stokes beam. Our inversion procedure is based on an accurate vectorial model linking the CARS image to the sample and yields both the real and imaginary parts of the susceptibility, the latter giving access to the Raman information, with an improved resolution.

10.
J Opt Soc Am A Opt Image Sci Vis ; 36(9): 1583, 2019 Sep 01.
Article in English | MEDLINE | ID: mdl-31503853

ABSTRACT

This publisher's note corrects a typo in the title of J. Opt. Soc. Am. A36, C1 (2019)JOAOD60740-323210.1364/JOSAA.36.0000C1.

11.
J Opt Soc Am A Opt Image Sci Vis ; 36(4): 478-484, 2019 Apr 01.
Article in English | MEDLINE | ID: mdl-31044960

ABSTRACT

In this paper, we introduce a formalism to determine the relationship between the full vectorial electric field existing at the object plane of a microscope and that existing at the image plane. The model is then used to quantitatively simulate, in both phase and intensity, the image of a radiating electric dipole placed either in a homogeneous medium or in the vicinity of a substrate. These simulations are compared with experimental measurements on single gold nanoparticles carried out by quadriwave lateral shearing interferometry.

12.
Opt Express ; 26(20): 26093-26105, 2018 Oct 01.
Article in English | MEDLINE | ID: mdl-30469701

ABSTRACT

We have developed a reflection tomographic microscope in which the sample is reconstructed from different holograms recorded under various angles and wavelengths of incidence. We present an iterative inversion algorithm based on a rigorous modeling of the wave-sample interaction that processes all the data simultaneously to estimate the sample permittivity distribution. We show that using several wavelengths permits a significant improvement of the reconstruction, especially along the optical axis.

13.
J Opt Soc Am A Opt Image Sci Vis ; 35(6): 1028-1033, 2018 Jun 01.
Article in English | MEDLINE | ID: mdl-29877348

ABSTRACT

We present a numerical study of a microscopy setup in which the sample is illuminated with uncontrolled speckle patterns and the two-photon excitation fluorescence is collected on a camera. We show that, using a simple deconvolution algorithm for processing the speckle low-resolution images, this wide-field imaging technique exhibits resolution significantly better than that of two-photon excitation scanning microscopy or one-photon excitation bright-field microscopy.

14.
Opt Lett ; 43(9): 2173-2176, 2018 May 01.
Article in English | MEDLINE | ID: mdl-29714782

ABSTRACT

Total internal reflection microscopy is mainly used in its fluorescence mode and is the reference technique to image fluorescent proteins in the vicinity of cell membranes. Here, we show that this technique can easily become a phase microscope by simply detecting the coherent signal resulting from the interference between the field scattered by the probed sample and the total internal reflection. Moreover, combining several illumination angles permits generating synthetic aperture reconstructions with improved resolutions compared to standard label-free microscopy techniques.


Subject(s)
Microscopy, Fluorescence/methods , Optical Phenomena , Pattern Recognition, Automated , Equipment Design
15.
J Opt Soc Am A Opt Image Sci Vis ; 33(6): 1089-94, 2016 Jun 01.
Article in English | MEDLINE | ID: mdl-27409435

ABSTRACT

We consider a fluorescence microscope in which several three-dimensional images of a sample are recorded for different speckle illuminations. We show, on synthetic data, that by summing the positive deconvolution of each speckle image, one obtains a sample reconstruction with axial and transverse resolutions that compare favorably to that of an ideal confocal microscope.

16.
J Opt Soc Am A Opt Image Sci Vis ; 32(2): 287-92, 2015 Feb 01.
Article in English | MEDLINE | ID: mdl-26366601

ABSTRACT

Tomographic diffractive microscopy is a three-dimensional imaging technique that reconstructs the permittivity map of the probed sample from its scattered field, measured both in phase and in amplitude. Here, we detail how polarization-resolved measurements permit us to significantly improve the accuracy and the resolution of the reconstructions, compared to the conventional scalar treatments used so far. An isotropic transverse resolution of about 100 nm at a wavelength of 475 nm is demonstrated using this approach.

18.
J Opt Soc Am A Opt Image Sci Vis ; 30(10): 2133-9, 2013 Oct 01.
Article in English | MEDLINE | ID: mdl-24322868

ABSTRACT

Tomographic diffractive microscopy (TDM) is a label-free imaging technique that reconstructs the 3D refractive index map of the probed object with an improved resolution compared to confocal microscopy. In this work, we consider a TDM implementation in which the sample is deposited on a reflective substrate. We show that this configuration requires calibration and inversion procedures that account for the presence of the substrate for getting highly resolved quantitative reconstructions.


Subject(s)
Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Microscopy, Confocal/methods , Microscopy/methods , Tomography/methods , Algorithms , Fourier Analysis , Refractometry
19.
Article in English | MEDLINE | ID: mdl-24483580

ABSTRACT

We present a form of the discrete dipole approximation for electromagnetic scattering computations in time domain. We show that the introduction of complex frequencies, through the Laplace transform, significantly improves the computation time. We also show that the Laplace transform and its inverse can be combined to extract the field inside a scatterer at a real resonance frequency.

20.
Phys Rev E Stat Nonlin Soft Matter Phys ; 85(5 Pt 2): 056602, 2012 May.
Article in English | MEDLINE | ID: mdl-23004890

ABSTRACT

We study electromagnetic forces and torques on a discrete spherical invisibility cloak under time-harmonic illumination. We consider the influence of material absorption and losses, and we show that while the impact of absorption on the optical force remains confined to frequencies near the absorption peak, its impact on the electromagnetic torque experienced by the cloak is spectrally broader and follows the spectrum of the absorption cross section of the cloak. We also investigate the mechanical shielding of a test particle within the cloak. We find that even an imperfect cloak can reduce the radiation pressure on the particle significantly; however, under certain conditions the force on the particle can be stronger than it would be in the absence of the cloak.

SELECTION OF CITATIONS
SEARCH DETAIL