Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
Add more filters










Publication year range
1.
Artif Organs ; 48(2): 182-190, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37787082

ABSTRACT

BACKGROUND: The objective of this study was to assess the pulsatility preservation capability of the universal ventricular assist device (UVAD) when used as a biventricular assist device (BVAD). This evaluation was conducted through an in vitro experiment, utilizing a pulsatile biventricular circulatory mock loop. METHODS: Two UVAD pumps were tested in a dual setup (BVAD) in the circulatory model with the simulated conditions of left heart failure (HF), right HF, and moderate/severe biventricular HF (BHF). The total flow, aortic pulse pressure, the pulse augmentation factor (PAF), the energy-equivalent pressure (EEP), and the surplus hemodynamic energy (SHE) were observed at various pump speeds to evaluate the pulsatility. RESULTS: The aortic pulse pressure increased from the baseline (without pump) in all simulated hemodynamic conditions. The PAF ranged from 17%-35% in healthy, left HF, right HF, and mild BHF conditions, with the highest PAF of 90% being observed in the severe BHF condition. The EEP correlated with LVAD flow in all groups (R2 = 0.87-0.97) and increased from the baseline in all cases. The SHE peaked at approximately 5-6 L/min of LVAD support and was likely to decrease at higher LVAD pump flow. The largest decrease in SHE from the baseline, 53%, was observed in the mild BHF conditions with the highest LVAD and RVAD support. CONCLUSIONS: The UVAD successfully demonstrated the ability to preserve pulsatility in vitro, and to optimize the cardiac output, as an isolated circulatory support device option (RVAD or LVAD) and when used for BVAD support.


Subject(s)
Heart Failure , Heart-Assist Devices , Humans , China , Ethnicity , Hemodynamics , Cardiac Output , Heart Failure/surgery
2.
ASAIO J ; 70(2): 116-123, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-37851000

ABSTRACT

Cleveland Clinic's continuous-flow total artificial heart (CFTAH) is being developed at our institution and has demonstrated system reliability and optimal performance. Based on the results from recent chronic in vivo experiments, CFTAH has been revised, especially to improve biocompatibility. The purpose of this article is to report our progress in developing CFTAH. To improve biocompatibility, the right impeller, the pump housing, and the motor were reviewed for design revision. Updated design features were based on computational fluid dynamics analysis and observations from in vitro and in vivo studies. A new version of CFTAH was created, manufactured, and tested. All hemodynamic and pump-related parameters were observed and found to be within the intended ranges, and the new CFTAH yielded acceptable biocompatibility. Cleveland Clinic's continuous-flow total artificial heart has demonstrated reliable performance, and has shown satisfactory progress in its development.


Subject(s)
Heart, Artificial , Heart-Assist Devices , Research Report , Reproducibility of Results , Hemodynamics , Hydrodynamics
3.
ASAIO J ; 69(7): 649-657, 2023 07 01.
Article in English | MEDLINE | ID: mdl-37018765

ABSTRACT

The objective of this study was to compare the estimates of pump flow and systemic vascular resistance (SVR) derived from a mathematical regression model to those from an artificial deep neural network (ADNN). Hemodynamic and pump-related data were generated using both the Cleveland Clinic continuous-flow total artificial heart (CFTAH) and pediatric CFTAH on a mock circulatory loop. An ADNN was trained with generated data, and a mathematical regression model was also generated using the same data. Finally, the absolute error for the actual measured data and each set of estimated data were compared. A strong correlation was observed between the measured flow and the estimated flow using either method (mathematical, R = 0.97, p < 0.01; ADNN, R = 0.99, p < 0.01). The absolute error was smaller in the ADNN estimation (mathematical, 0.3 L/min; ADNN 0.12 L/min; p < 0.01). Furthermore, strong correlation was observed between measured and estimated SVR (mathematical, R = 0.97, p < 0.01; ADNN, R = 0.99, p < 0.01). The absolute error for ADNN estimation was also smaller than that of the mathematical estimation (mathematical, 463 dynes·sec·cm -5 ; ADNN, 123 dynes·sec·cm -5 , p < 0.01). Therefore, in this study, ADNN estimation was more accurate than mathematical regression estimation. http://links.lww.com/ASAIO/A991.


Subject(s)
Heart, Artificial , Hemodynamics , Child , Humans , Vascular Resistance , Neural Networks, Computer , Models, Theoretical
4.
Front Cardiovasc Med ; 10: 1045656, 2023.
Article in English | MEDLINE | ID: mdl-36910535

ABSTRACT

Objective: Severe biventricular heart failure (BHF) can be remedied using a biventricular assist device (BVAD). Two devices are currently in development: a universal ventricular assist device (UVAD), which will be able to assist either the left, right, or both ventricles, and a continuous-flow total artificial heart (CFTAH), which replaces the entire heart. In this study, the in vitro hemodynamic performances of two UVADs are compared to a CFTAH acting as a BVAD. Methods: For this experiment, a biventricular mock circulatory loop utilizes two pneumatic pumps (Abiomed AB5000™, Danvers, MA, USA), in conjunction with a dual-output driver, to create heart failure (HF) conditions (left, LHF; right, RHF; biventricular, BHF). Systolic BHF for four different situations were replicated. In each situation, CFTAH and UVAD devices were installed and operated at two distinct speeds, and cannulations for ventricular and atrial connections were evaluated. Results: Both CFTAH and UVAD setups achieved our recommended hemodynamic criteria. The dual-UVAD arrangement yielded a better atrial balance to alleviate LHF and RHF. For moderate and severe BHF scenarios, CFTAH and dual UVADs both created excellent atrial pressure balance. Conversely, when CFTAH was atrial cannulated for LHF and RHF, the needed atrial pressure balance was not met. Conclusion: Comprehensive in vitro testing of two different BVAD setups exhibited self-regulation and exceptional pump performance for both (single- and dual-device) BHF support scenarios. For treating moderate and severe BHF, UVAD and CFTAH both functioned well with respect to atrial pressure regulation and cardiac output. Though, the dual-UVAD setup yielded a better atrial pressure balance in all BHF testing scenarios.

5.
Heart Fail Rev ; 28(2): 287-296, 2023 03.
Article in English | MEDLINE | ID: mdl-33931816

ABSTRACT

A novel pump, the left atrial assist device (LAAD), is a device specifically for the treatment of heart failure with preserved ejection fraction (HFpEF). The LAAD is a mixed-flow pump that is implanted in the mitral position and delivers blood from the left atrium to the left ventricle. During the development process, we aimed to explore whether device activation in torque control (TC) mode would improve the function of the LAAD. The TC mode causes adjustment of the pump speed automatically during each cardiac cycle in order to maintain a specified torque. In this study, we tested four different TC settings (TC modes 0.9, 1.0, 1.25, and 1.5) using an in vitro mock circulatory loop. Mild, moderate, and severe diastolic heart failure (DHF) conditions, as well as normal heart condition, were simulated with the four TC modes. Also, we evaluated the LAAD in vivo with three calves. The LAAD was implanted at the mitral position with four TC settings (TC modes 0.9, 1.0, 1.1, 1.2). With LAAD support, the in vitro cardiac output and aortic pressure recovered to normal heart levels at TC 1.25 and 1.5 even under severe DHF conditions with little pump regurgitation. The TC mode tested in vivo with three calves, and it also showed favorable result without elevating the left ventricular end-diastolic pressure. These initial in vitro and in vivo results suggest that the TC mode could be potentially effective, and the LAAD could be a treatment option for HFpEF patients.


Subject(s)
Atrial Fibrillation , Heart Failure, Diastolic , Heart Failure , Heart-Assist Devices , Humans , Animals , Cattle , Heart Failure/surgery , Stroke Volume/physiology , Torque , Heart Atria , Ventricular Function, Left/physiology
6.
Artif Organs ; 46(8): 1555-1563, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35318688

ABSTRACT

BACKGROUND: The evaluation of pulsatile flow created by the new Cleveland Clinic continuous-flow total artificial heart (CFTAH100), which has a re-designed right impeller and motor, had not been tested in vivo. The purpose of this study was to evaluate the feasibility of pulsatility with the CFTAH100 during the application of pump speed modulation protocols in a chronic animal model. METHODS: A 30-day chronic animal experiment was conducted with a calf. Five pulsatile studies were performed on the alert animal. The mean pump speed was set at 2800 rpm, and modulated sinusoidally within a range of 0 to ± 35% of mean speed, in increments of 5% at 80 beats per minute (bpm). The pressures and pump flow were collected and a pulsatility index (PI) was calculated. RESULTS: The calf was supported with the CFTAH100 without any major complications. The maximum and minimum pump flows changed significantly from baseline in all conditions, while the mean pump flow did not change. All flow pulsatility (FP) readings in all conditions significantly increased from baseline, and the percent modulation (%S) and FP had a strong positive correlation (r = 0.99, p < 0.01). The PI also increased significantly in all conditions (maximum at %S of 35%, 2.2 ± 0.05, p < 0.01), and a positive correlation between %S and PI (r = 0.99, p < 0.01) was observed. CONCLUSION: The CFTAH100 showed the feasibility of creating pulsatile circulation with sinusoidal pump speed modulation.


Subject(s)
Heart, Artificial , Heart-Assist Devices , Animals , Hemodynamics , Pulsatile Flow
7.
J Card Fail ; 28(5): 789-798, 2022 05.
Article in English | MEDLINE | ID: mdl-35027316

ABSTRACT

BACKGROUND: We are developing a left atrial assist device (LAAD) that is implanted at the mitral position to treat diastolic heart failure (DHF) represented by heart failure with preserved ejection fraction. METHODS: The LAAD was tested at 3 pump speeds on a pulsatile mock loop with a pneumatic pump that simulated DHF conditions by adjusting the diastolic drive. The LAAD was implanted in 6 calves, and the hemodynamics were assessed. In 3 cases, DHF conditions were induced by using a balloon inserted into the left ventricle, and in 2 cases, mitral valve replacement was also performed after the second aortic cross-clamp. RESULTS: DHF conditions were successfully induced in the in vitro study. With LAAD support, cardiac output, aortic pressure and left atrial pressure recovered to normal values, whereas pulsatility was maintained for both in vivo and in vitro studies. Echocardiography showed no left ventricular outflow tract obstruction, and the LAAD was successfully replaced by a mechanical prosthetic valve. CONCLUSIONS: These initial in vitro and in vivo results support our hypothesis that use of the LAAD increases cardiac output and aortic pressure and decreases left atrial pressure, while maintaining arterial pulsatility.


Subject(s)
Heart Failure, Diastolic , Heart Failure , Heart-Assist Devices , Animals , Cattle , Heart Failure, Diastolic/therapy , Hemodynamics , Humans , Stroke Volume
8.
ASAIO J ; 68(8): 1024-1035, 2022 08 01.
Article in English | MEDLINE | ID: mdl-34772847

ABSTRACT

We are developing a universal, advanced ventricular assist device (AVAD) with automatic pressure regulation suitable for both left and right ventricular support. The primary goal of this computational fluid dynamics (CFD) study was to analyze the biventricular performance of the AVAD across its wide range of operating conditions. An AVAD CFD model was created and validated using in vitro hydraulic performance measurements taken over conditions spanning both left ventricular assist device (LVAD) and right ventricular assist device (RVAD) operation. Static pressure taps, placed throughout the pump, were used to validate the CFD results. The CFD model was then used to assess the change in hydraulic performance with varying rotor axial positions and identify potential design improvements. The hydraulic performance was simulated and measured at rotor speeds from 2,300 to 3,600 revolutions/min and flow rates from 2.0 to 8.0 L/min. The CFD-predicted hydraulic pressure rise agreed well with the in vitro measured data, within 6.5% at 2300 rpm and within 3.5% for the higher rotor speeds. The CFD successfully predicted wall static pressures, matching experimental values within 7%. High degree of similarity and circumferential uniformity in the pump's flow fields were observed over the pump operation as an LVAD and an RVAD. A secondary impeller axial clearance reduction resulted in a 10% decrease in peak flow residence time and lower static pressures on the secondary impeller. These lower static pressures suggest a reduction in the upwards rotor forces from the secondary impeller and a desired increase in the pressure sensitivity of the pump. The CFD analyses supported the feasibility of the proposed AVAD's use as an LVAD or an RVAD, over a wide range of operating conditions. The CFD results demonstrated the operability of the pump in providing the desired circumferential flow similarity over the intended range of flow/speed conditions and the intended functionality of the AVAD's automated pressure regulation.


Subject(s)
Heart-Assist Devices , Equipment Design , Hydrodynamics , Models, Cardiovascular
9.
ASAIO J ; 68(6): 829-838, 2022 06 01.
Article in English | MEDLINE | ID: mdl-34560715

ABSTRACT

Cleveland Clinic is developing a continuous-flow total artificial heart (CFTAH). This novel design operates without valves and is suspended both axially and radially through the balancing of the magnetic and hydrodynamic forces. A series of long-term animal studies with no anticoagulation demonstrated good biocompatibility, without any thromboemboli or infarctions in the organs. However, we observed varying degrees of thrombus attached to the right impeller blades following device explant. No thrombus was found attached to the left impeller blades. The goals for this study were: (1) to use computational fluid dynamics (CFD) to gain insight into the differences in the flow fields surrounding both impellers, and (2) to leverage that knowledge in identifying an improved next-generation right impeller design that could reduce the potential for thrombus formation. Transient CFD simulations of the CFTAH at a blood flow rate and impeller rotational speed mimicking in vivo conditions revealed significant blade tip-induced flow separation and clustered regions of low wall shear stress near the right impeller that were not present for the left impeller. Numerous right impeller design variations were modeled, including changes to the impeller cone angle, number of blades, blade pattern, blade shape, and inlet housing design. The preferred, next-generation right impeller design incorporated a steeper cone angle, a primary/splitter blade design similar to the left impeller, and an increased blade curvature to better align the incoming flow with the impeller blade tips. The next-generation impeller design reduced both the extent of low shear regions near the right impeller surface and flow separation from the blade leading edges, while maintaining the desired hydraulic performance of the original CFTAH design.


Subject(s)
Heart, Artificial , Heart-Assist Devices , Thrombosis , Equipment Design , Heart-Assist Devices/adverse effects , Humans , Hydrodynamics , Thrombosis/etiology
10.
Artif Organs ; 38(5): 374-82, 2014 May.
Article in English | MEDLINE | ID: mdl-24118024

ABSTRACT

The PediPump was implanted in six healthy lambs (mean 25.6 ± 1.4 kg) between the left ventricular apex and the descending aorta to evaluate in vivo performance for up to 30 days. Anticoagulation was achieved by continuous heparin infusion. Three animals were euthanized prematurely, two because of respiratory dysfunction and one because of deteriorating pump performance resulting from thrombus formation inside the pump. Three lambs were electively sacrificed 30 days after implantation; all had stable hemodynamics and minimal hemolysis, as indicated by low plasma free hemoglobin (2.5 ± 3.1 mg/dL). Mean 30-day pump flow was 1.8 ± 0.1 L/min at a pump speed of 12 200 ± 400 rpm. Neither activated clotting time nor activated partial thromboplastin time followed the changes in heparin dose. At necropsy, depositions were observed at the front (n = 1) and rear rotor axial positioning stops (n = 4); improved polishing techniques on the stationary stop surfaces and the addition of a hard-carbon, thin-film coating on the rotating stop of the pumps used for the last two experiments addressed the deposition seen earlier. In conclusion, the PediPump showed excellent hydraulic performance and minimal hemolysis during support for up to 30 days. Depositions observed at the axial positioning stops in earlier experiments were addressed by design and material refinements. We continue to focus on developing effective anticoagulation management in the lamb model as well as on further evaluating and demonstrating pump biocompatibility.


Subject(s)
Heart Defects, Congenital/surgery , Heart Ventricles/surgery , Heart-Assist Devices , Animals , Anticoagulants/therapeutic use , Heart Defects, Congenital/blood , Heart Defects, Congenital/physiopathology , Heart Ventricles/physiopathology , Heart-Assist Devices/adverse effects , Hemodynamics , Prosthesis Design , Sheep
11.
Artif Organs ; 33(11): 1005-8, 2009 Nov.
Article in English | MEDLINE | ID: mdl-20050296

ABSTRACT

Cleveland Clinic's PediPump (Cleveland, OH, USA) is a ventricular assist device designed for the support of pediatric patients. The PediPump is a mixed-flow ventricular assist device with a magnetically suspended impeller measuring 10.5 mm in diameter by 64.5 mm in length. Progress and achievements for the PediPump program are considered according to the development project's three primary objectives: Basic engineering: along with size reductions, substantial design improvements have been incorporated in each design iteration including the motor, magnetic bearings, axial touch points, and heat transfer path; Anatomic modeling and device fitting studies: Techniques based on computed tomography and magnetic resonance imaging have been developed to create three-dimensional anatomic-modeling and device-fitting tools to facilitate device implantation and to assist in preoperative planning. For in vivo testing, to date, six acute (6-h duration) and nine chronic (30-day target duration) implantations have been performed in sheep; the implantation of the PediPump appears to be relatively easy with excellent hemodynamic performance and minimal hemolysis during support. Cleveland Clinic's PediPump program supported by the National Heart, Lung and Blood Institute's Pediatric Circulatory Support Program has led to the development of a pediatric ventricular assist device that has satisfactory performance in preclinical evaluation and appears to be ready to support a program of clinical testing.


Subject(s)
Heart Valve Prosthesis Implantation , Heart-Assist Devices , Animals , Hemodynamics , Hemolysis , Humans , Infant , Pediatrics/instrumentation , Prosthesis Design , Sheep
12.
ASAIO J ; 54(1): 58-63, 2008.
Article in English | MEDLINE | ID: mdl-18204317

ABSTRACT

Incompetent inflow valves have been reported with clinical pulsatile left ventricular assist devices that use bioprosthetic valves. Suspected as the cause of premature valve failure within these devices, absolute pressures and instantaneous pressure changes were evaluated in the MagScrew total artificial heart (TAH). The MagScrew TAH is a passively filling pulsatile pump which uses a reciprocating magnetic actuating mechanism under various control modes to propel blood into circulation. Both right and left ejection speeds were modulated and optimized at the onset of hydraulic eject. These various speed profiles were evaluated in vitro at 220 beats per minute (bpm), 100% pump fill, mean aortic pressure of 100 mm Hg and mean pulmonary artery pressure of 20 mm Hg. The pressure inside the left and right pump chambers was measured with Millar Mikro-Tip catheter and captured using Power Lab at a rate of 40 kHz. The pump chamber peak pressure, operating with unmodified eject speeds, measured on average 183 mm Hg for the left and 133 mm Hg for the right. Eject speed profiling for both pumps reduced the peak pressure by 10% and 28% for the left and right pump, respectively. Future studies will assess software controlled optimization of the eject speed profiles under any operating condition and how effective it is in vivo.


Subject(s)
Heart, Artificial , Heart-Assist Devices , Blood Flow Velocity , Blood Pressure , Cardiac Output , Equipment Design , Heart Rate , Hemodynamics , Humans , In Vitro Techniques , Oscillometry , Pressure , Prosthesis Design , Software , Stress, Mechanical
13.
Artif Organs ; 31(9): 667-76, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17725694

ABSTRACT

To evaluate the effects of downsizing of the total artificial heart (TAH), we compared the anaerobic threshold (AT) values in calves with two different types of TAH (Cleveland Clinic-Nimbus TAH and the downsized MagScrew TAH). Exercise studies were performed using a treadmill in 12 calves. During the exercise, parameters to obtain the AT were measured. To evaluate the determinants of the AT, a linear regression analysis was performed between AT and potential variables. AT values from 29 studies revealed no significant differences between the two different TAHs, with no significant differences in hemodynamic or oxygen metabolic parameters. AT values correlated well with pump flow/body weight (Q) multiplied by the hemoglobin level, regardless of the TAH used. In conclusion, downsizing of the original TAH design did not reduce AT without any significant differences in hemodynamic or oxygen metabolic parameters during exercise in calves.


Subject(s)
Anaerobic Threshold , Blood Circulation , Heart, Artificial , Lactic Acid/blood , Oxygen Consumption , Physical Exertion , Animals , Cattle , Equipment Design , Hemoglobins/metabolism , Linear Models , Materials Testing , Models, Cardiovascular , Research Design
14.
ASAIO J ; 52(4): 368-72, 2006.
Article in English | MEDLINE | ID: mdl-16883114

ABSTRACT

The MagScrew total artificial heart (TAH) is under development. Despite its anticipated durability and reliability, the possibility of a bioprosthetic valve malfunction exists. As a result, the potential for valve replacement surgery, instead of device replacement, would be desirable after a TAH implant. In two of our 90-day animal experiments, we successfully replaced the left-side valves through a left thoracotomy opposite to the right-sided incision site for the initial TAH implant. The results of these cases suggest that the left-side valves could also be replaced through a left thoracotomy approach in humans. To confirm the ability to access the left-side valves in humans, four human cadaver studies were performed with the use of a mock pump designed for human application. This report describes the operative techniques for left-side valve replacement in animals and discusses the advantages of a left thoracotomy in clinical situations, based on results from the human cadaver studies.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Heart, Artificial , Thoracotomy/methods , Animals , Cattle , Feasibility Studies , Female , Humans , Male , Prostheses and Implants , Prosthesis Design , Prosthesis Failure , Prosthesis Fitting , Reoperation/methods , Time Factors
15.
Ann Thorac Surg ; 79(4): 1378-83; discussion 1383, 2005 Apr.
Article in English | MEDLINE | ID: mdl-15797082

ABSTRACT

PURPOSE: Downsizing pulsatile devices requires an increase of beat rate if flow capacity is to be maintained. We applied this concept to the preclinical MagScrew total artificial heart (TAH). DESCRIPTION: The device fills passively with a stroke volume of 45 ml and beat rates up to 250 beats per minute (bpm). EVALUATION: Stable hemodynamics were observed during a 30-day bovine implant with a flow of 8.7 +/- 1.2 L/min at beat rates of 204 +/- 18 bpm. Device filling was exceptional up to 250 bpm generating flow of greater than 12 L/min. Beat rate adapted to preload in a way similar to a Frank-Starling response. Left and right atrial pressures were balanced. The aortic pulse pressure was 49-70 mm Hg, which translates to a pulsatility index of 0.49-0.77. Organ functions were preserved and blood damage did not occur. CONCLUSIONS: Increasing the beat rate while downsizing the MagScrew TAH was successful with strong flow generation by passive filling. Pulsatility was maintained at high beat rates. This innovative approach may be used to develop small pulsatile pumps.


Subject(s)
Heart, Artificial , Animals , Blood Pressure , Cattle , Heart Rate , Stroke Volume
16.
ASAIO J ; 49(5): 594-8, 2003.
Article in English | MEDLINE | ID: mdl-14524571

ABSTRACT

Currently available ventricular assist devices (VADs) have limitations in long-term durability and blood compatibility. We evaluated a prototype of a pulsatile MagScrew VAD for in vivo hemodynamic performance and biocompatibility. The device is composed of an actuator, blood pump housing, diaphragm, pusher plate, and bioprosthetic valves. Its protein-coated ("biolized") blood-contacting surface inhibits clot formation. Forces between moving parts of the actuator are transmitted magnetically, eliminating a primary source of friction and wear. The pump fills passively and is highly preload sensitive. The device was implanted into three calves for 90, 10, and 57 days, respectively. No anticoagulants were given postoperatively. The device functioned without technical problems during the entire course of each experiment, with mean device flow ranging between 5.4 and 9.0 L/min. Autopsy of the first two calves revealed no sign of embolization and clean blood-contacting surfaces of the devices. The third experiment was complicated by a prosthetic valve endocarditis with infectious embolization, and a few small depositions were found in the pump. In conclusion, the MagScrew VAD has demonstrated a high level of performance and biocompatibility in three calves studied for 10-90 days. Vigorous development is in progress to bring this device to preclinical readiness and thus provide surgeons with the VAD of choice for permanent implantation.


Subject(s)
Coated Materials, Biocompatible , Embolism/prevention & control , Heart-Assist Devices , Animals , Cattle , Gelatin , Magnetics/instrumentation , Male
SELECTION OF CITATIONS
SEARCH DETAIL