Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Polymers (Basel) ; 15(10)2023 May 10.
Article in English | MEDLINE | ID: mdl-37242825

ABSTRACT

(1) Background: This study evaluates the effect of a conventional/low-voltage light-curing protocol (LV protocol) (10 s with 1340 mW/cm2) and high-voltage light-curing protocol (HV protocol) (3 s with 3440 mW/cm2) on the microhardness (MH) of dental resin-based composites (RBCs). Five resin composites were tested: conventional Evetric (EVT), Tetric Prime (TP), Tetric Evo Flow (TEF), bulk-fill Tetric Power Fill (PFL), and Tetric Power Flow (PFW). (2) Materials and Methods: Two tested composites (PFW and PFL) were designed for high-intensity light curing. The samples were made in the laboratory in specially designed cylindrical molds; diameter = 6 mm and height = 2 or 4 mm, depending on the type of composite. Initial MH was measured on the top and bottom surfaces of composite specimens 24 h after light curing using a digital microhardness tester (QNESS 60 M EVO, ATM Qness GmbH, Mammelzen, Germany). The correlation between the filler content (wt%, vol%) and the MH of the RBCs was tested. For the calculation of depth-dependent curing effectiveness, the bottom/top ratio for initial MH was used. (3) Conclusions: MH of RBCs is more dependent on material composition than on light-curing protocol. Filler wt% has a greater influence on MH values compared to filler vol%. The bottom/top ratio showed values over 80% for bulk composites, while for conventional sculptable composites, borderline or suboptimal values were measured for both curing protocols.

2.
Acta Stomatol Croat ; 56(1): 22-32, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35382484

ABSTRACT

Objectives: The study aimed to compare the color stability of two different light-cured composites after immersion in three liquids and the effectiveness of 16% carbamide peroxide (CP) in removing the discoloration. Material and methods: Color stability of a microhybrid (Z250, 3M ESPE) and nanocomposite (Z550, 3M ESPE) was evaluated after immersion in instant coffee, tea, Coca-Cola, and deionized water as a control group (n=5). Samples were kept in liquids for four hours daily at 37°C for 30 days. Furthermore, 16% CP was applied for the following 14 days, simulating night whitening. A digital spectrophotometer was used for color measurement based on the CIEL*a*b* color coordinates. The color changes (∆E) were measured at baseline, after immersion in the beverages, and also after the teeth whitening procedure. Mixed and factorial ANOVA followed by Bonferroni's post-hoc test were used for statistical evaluation (p≤0.05). Results: Tested resin composites showed a color change over the acceptability threshold (ΔE*> 3.48) after immersion in coffee and tea. Nanocomposite reported a significant increase in discoloration in coffee after 30 days (p <0.05). The color of both materials significantly changed (p<0.05) along all three L*a*b* axes in coffee and tea to darker, yellow, and red. Whitening with 16% CP was effective in removing external discoloration in both examined composite materials. Conclusion: Coffee and tea induced clinically detectable color changes in dental composites tested, with cumulative effects. Whitening represents an efficient method for the removal of surface discoloration in composite restorations.

3.
Eur J Dent ; 16(4): 886-894, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35279820

ABSTRACT

OBJECTIVES: The aim of the study was to analyze the occurrence of stress on teeth with abfraction lesions restored with six different restorative materials, and by introducing the tensile strength parameters to calculate the safety factor of the material under the load (ratio between the strength of the material and the maximum stress). MATERIALS AND METHODS: Three-dimensional models of the mandibular premolar are created from a microcomputed tomography images. An abfraction lesion is modeled on the tooth. The stress of the dental tissues and six restorative materials under functional and nonfunctional occlusal loading of 200 (N) are analyzed by finite element method. STATISTICAL ANALYSIS: CTAn program 1.10 and ANSYS Workbench (version 14.0) were used for analysis. Results are presented in von Mises stress. RESULTS: Oblique loads caused ≈ four times higher stress in restorative materials than the axial ones. It is noticeable that high values of von Mises stress are measured at the bottom of the sharp lesion, even up to 240 MPa, that are significantly reduced after the restoration. The highest stresses at the restorative material are present at the lower (gingival) margin of the restoration. The highest stresses under both types of loads are measured in nanohybrid composite (Tetric EvoCeram, Ivoclar Vivadent). The lowest values of the stress are measured in the flowable composite (Tetric Flow, Ivoclar Vivadent), but at the same time, the highest value of the stress is measured in the surrounding dental tissues on the tooth restored with the flowable composite. The microhybrid composite (Herculite XR, Kerr), with the highest safety factor, is the material that best withstands the stresses it is exposed to. The obtained safety factor did not exceed the critical limit, except for the glass ionomer cement, with the safety factor lower than 1. CONCLUSION: The type of tooth loading has the greatest influence on the intensity of stress. The value of the obtained stresses in the restorative material and dental tissues differ due to the different mechanical properties of the materials. Restoration of noncarious lesions significantly reduces extremely high stress values at their bottom.

4.
Acta Med Acad ; 50(3): 397-405, 2021 Dec.
Article in English | MEDLINE | ID: mdl-35164518

ABSTRACT

OBJECTIVES: To test the influence of a bleaching procedure using 16% carbamide peroxide (CP) on the colour of composite materials and their consecutive subjection to discolouration in beverages. MATERIALS AND METHODS: Nanocomposite Z550 (3M ESPE) and the microhybrid Z250 (3M ESPE) composite materials were selected for the research. 16% CP was applied to composite plates (15 samples each material) for seven hours a day for 14 days simulating at-home nightguard vital bleaching. The test samples were then divided randomly into three sub-groups and submerged in instant coffee, green tea and Coca Cola for 30 days. The control group (N=5) samples were kept in deionized water. Determination of the L*a*b* dimensions of colour of the polymerized discs was performed by calibrated spectrophotometer 24 hours later, after the bleaching procedure, and on days 7, 15 and 30 after immersion in the beverages. RESULTS: After application of 16% CP, there were perceptible changes in the colour of both test materials, which did not exceed the boundaries of acceptability (ΔE<3.48). Coca-Cola did not cause discolouration of the tested composites, but coffee and tea changed their colour above the level of perceptibility already seven days after immersion. A statistically significant difference in the change in colour was established between the materials when they were immersed in coffee (P<0.05). CONCLUSIONS: 16% CP does not affect the basic colour of the composites. Immersion in a beverage led to an unacceptable change in the colour of both test materials in coffee and tea, primarily towards black. The greatest discolouration after bleaching was shown by Z550 when immersed in coffee.


Subject(s)
Coffee , Composite Resins , Beverages , Coffee/adverse effects , Color , Humans , Materials Testing , Surface Properties
5.
Acta Med Acad ; 49(1): 57-66, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32738118

ABSTRACT

OBJECTIVE: To evaluate and compare the solubility of three luting cements in three different solutions: distilled water and artificial saliva with different pH values (7.4 and 3.0). MATERIALS AND METHODS: Resin-modified glass-ionomer cement (GC Fuji Plus) and two resin cements (Multilink Automix and Variolink II) were used. A total of 45 specimens, 15 specimens (15x1 mm) for each cement, were prepared according to ISO standard 4049:2009. The solubility of the cements was calculated by weighing the specimens before and after immersion and desiccation. Values of solubility in water (Wsl) in microgram/mm3 for each of the five specimens were calculated using the following formula (ISO 4049:2009): Wsl=(m1-m3)/V. The Mann-Whitney U nonparametric statistical method and Post hoc sample comparisons were applied. RESULTS: GC Fuji Plus showed statistically significant higher solubility in comparison with Variolink II and Multilink Automix in all three solutions. In acidic artificial saliva (pH 3.0) Multilink Automix showed significantly higher values of solubility compared to Variolink II (P<0.016). By studying the effect of pH value on the solubility of GC Fuji Plus cement, significantly higher values of solubility in pH 3.0 artificial saliva were confirmed (P<0.009). The influence of the surrounding pH value on the solubility of the resin cements Multilink Automix and Variolink II was researched. No statistically significant difference was found. CONCLUSION: Solubility values were mainly influenced by the proportion of hydrophilic matrix, the type and composition of filler, and the pH value of the solutions.


Subject(s)
Glass Ionomer Cements/chemistry , Resin Cements/chemistry , Saliva , Water , Humans , Hydrogen-Ion Concentration , Hydrophobic and Hydrophilic Interactions , Solubility
6.
Acta Med Acad ; 48(3): 255-261, 2019 Dec.
Article in English | MEDLINE | ID: mdl-32124623

ABSTRACT

OBJECTIVE: The aim of this paper was to analyze the distribution of stress and deformation on the mandibular first premolar under two types of loading (axial and para-axial load of 200 N) using the FEM computer method. MATERIALS AND METHOD: For this research a µCT scan of the first mandibular premolar was used, and the method used in this research was FEM analysis under two types of loading. RESULTS: The values of the von Mises stress measured in the cervical part of an intact tooth under axial load were up to 12 MPa, and under paraaxial load over 50 MPa. The values of the stress measured on the bottom of the noncarious lesion are very high ≈ 240 Mpa. Stress values in the cervical part of the intact tooth are higher in the zone of the sub-surface enamel. The deformation values of the tooth under para-axial loading were ≈ 10 times higher than the value of the deformation under axial load. The greatest deformations were seen in the area of the tooth crown. CONCLUSIONS: Occlusal loading leads to significant stress in the cervical part of teeth. The values of the measured stress are greater under the action of paraxial load. The values of stress in abfraction lesions measured under a paraxial load are extremely high. Exposing the lesion to further stress will lead to its deepening. The total deformation of the entire tooth under paraxial load was ≈ 10 times higher compared to the deformation value of the tooth under axial load.


Subject(s)
Bicuspid/physiology , Bite Force , Bicuspid/diagnostic imaging , Finite Element Analysis , Humans , Mandible , Tooth Cervix/physiology , Weight-Bearing/physiology , X-Ray Microtomography
7.
Acta Med Acad ; 46(2): 124-132, 2017 Nov.
Article in English | MEDLINE | ID: mdl-29338276

ABSTRACT

OBJECTIVE: To evaluate and compare the water sorption of three luting cements in three different solutions: distilled water and artificial saliva with different pH values (7.4 and 3.0). MATERIALS AND METHODS: Resin-modified glass-ionomer cement (GC Fuji Plus) and two resin cements (Multilink Automix and Variolink II) were used. A total of 45 specimens - 15 specimens (15x1 mm) for each cement were prepared according to ISO standard 4049:2009. The water sorptions of the cements were calculated by weighing the specimens before and after immersion and desiccation. RESULTS: . Nonparametric statistic methods were applied. GC Fuji Plus cement showed significantly higher values of water sorption in all three solutions of both resin cements (p<0.009) and significantly higher values of sorption in artificial saliva pH 3.0. Multilink Automix showed significantly higher values of water sorption compared with Variolink II in artificial saliva pH 7.4, and higher values of sorption in this solution compared with pH value 3.0. CONCLUSION: Water sorption values are mainly influenced by the proportion of hydrophilic matrix, the type and composition of filler, and the pH value of solutions.


Subject(s)
Glass Ionomer Cements/chemistry , Resin Cements/chemistry , Water/chemistry , Dental Cements , Humans , Hydrogen-Ion Concentration , Hydrophobic and Hydrophilic Interactions , Solutions
SELECTION OF CITATIONS
SEARCH DETAIL