Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Talanta ; 248: 123579, 2022 Oct 01.
Article in English | MEDLINE | ID: mdl-35660999

ABSTRACT

Lateral flow devices (LFDs) or lateral flow tests (LFTs) are one of the most widely used biosensor platforms for point-of-care (POC) diagnostics. The basic LFD design has remained largely unchanged since its first appearance, and this has limited LFD use in clinical applications due to a general lack of analytical sensitivity. We report here a comprehensive study of the use of laser-patterned geometric control barriers that influence the flow dynamics within an LFD, with the specific aim of enhancing LFD sensitivity and lowering the limit of detection (LOD). This control of sample flow produces an increase in the time available for optimizing the binding kinetics of the implemented assay. The geometric modification to the flow path is in the form of a constriction that is produced by depositing a photo-sensitive polymer onto the nitrocellulose membrane which when polymerized, creates impermeable barrier walls through the depth of the membrane. Both the position of the constriction within the flow path and the number of constrictions allow for an increase in the sensitivity because of a slower overall flow rate within the test and a larger volume of sample per unit width of the test line. For these high sensitivity LFDs (HS-LFD), through optimization of the constriction position and addition of a second constriction we attained a 62% increase in test line color intensity for the detection of procalcitonin (PCT) and were also able to lower the LOD from 10 ng/mL to 1 ng/mL. In addition, of relevance for future commercial exploitation, this also significantly decreases the antibody consumption per device leading to reduced costs for test production. We have further tested our HS-LFD with contrived human samples, validating its application for future clinical use.


Subject(s)
Biosensing Techniques , Collodion , Humans , Nucleic Acid Amplification Techniques , Polymerization , Sensitivity and Specificity
2.
Talanta ; 237: 122944, 2022 Jan 15.
Article in English | MEDLINE | ID: mdl-34736671

ABSTRACT

Inflammatory markers including C-reactive protein (CRP) and procalcitonin (PCT) have been shown to be useful biomarkers to improve triage speed and prevent the inappropriate use of antibiotics for infections such as pneumonia. Here, we present a novel and exciting solution to guide the administration of antibiotic treatment via rapid, semi-quantitative and multiplexed detection of CRP and PCT using an advanced lateral flow device (LFD) designed to have multiple parallel flow-paths, produced via the precise laser-based partitioning of the single flow-path of a standard LFD. Each flow-path within this multiplexed LFD has a unique detection capability which permits tailored detection of CRP within a predefined cut-off range (20 µg/mL - 100 µg/mL) and PCT above a pre-defined threshold (0.5 ng/mL). We demonstrate the use of this LFD in the successful detection of CRP and PCT semi-quantitatively within spiked human serum samples. This multiplexed near-patient assay has potential for development into a rapid triage and treatment of patients with suspected pneumonia.


Subject(s)
Pneumonia , Procalcitonin , Biomarkers , C-Reactive Protein , Humans , Lasers
3.
Anal Chim Acta ; 1185: 339002, 2021 Nov 15.
Article in English | MEDLINE | ID: mdl-34711332

ABSTRACT

As the SARS-CoV-2 pandemic continues to spread, the necessity for rapid, easy diagnostic capabilities could never have been more crucial. With this aim in mind, we have developed a cost-effective and time-saving testing methodology/strategy that implements a sensitive reverse transcriptase loop-mediated amplification (RT-LAMP) assay within narrow, commercially available and cheap, glass capillaries for detection of the SARS-CoV-2 viral RNA. The methodology is compatible with widely used laboratory-based molecular testing protocols and currently available infrastructure. It employs a simple rapid extraction protocol that lyses the virus, releasing sufficient genetic material for amplification. This extracted viral RNA is then amplified using a SARS-CoV-2 RT-LAMP kit, at a constant temperature and the resulting amplified product produces a colour change which can be visually interpreted. This testing protocol, in conjunction with the RT-LAMP assay, has a sensitivity of ∼100 viral copies per reaction of a sample and provides results in a little over 30 min. As the assay is carried out in a water bath, commonly available within most testing laboratories, it eliminates the need for specialised instruments and associated skills. In addition, our testing pathway requires a significantly reduced quantity of reagents per test while providing comparable sensitivity and specificity to the RT-LAMP kit used in this study. While the conventional technique requires 25 µl of reagent, our test only utilises less than half the quantity (10 µl). Thus, with its minimalistic approach, this capillary-based assay could be a promising alternative to the conventional testing, owing to the fact that it can be performed in resource-limited settings, using readily available apparatus, and has the potential of increasing the overall testing capacity, while also reducing the burden on supply chains for mass testing.


Subject(s)
COVID-19 , COVID-19 Testing , Capillaries , Clinical Laboratory Techniques , Cost-Benefit Analysis , Humans , Molecular Diagnostic Techniques , Nucleic Acid Amplification Techniques , Point-of-Care Systems , Point-of-Care Testing , RNA, Viral/genetics , RNA-Directed DNA Polymerase , SARS-CoV-2 , Sensitivity and Specificity
4.
Biosens Bioelectron ; 152: 112008, 2020 Mar 15.
Article in English | MEDLINE | ID: mdl-31941621

ABSTRACT

Antimicrobial resistance (AMR) has been identified by the World Health Organisation as a global threat that currently claims at least 25,000 deaths each year in Europe and 700,000 globally; the number is projected to reach 10 million per year between 2015 and 2050. Therefore, there is an urgent need for low-cost but reliable point-of-care diagnostics for early screening of infections especially in developing countries lacking in basic infrastructure and trained personnel. This work is aimed at developing such a device, a paper-based microfluidic device for infection testing by an unskilled user in a low resource setting. Here, we present our work relating to the use of our laser-patterned paper-based devices for detection and susceptibility testing of Escherichia coli, via a simple visually observable colour change. The results indicate the suitability of our integrated paper devices for timely identification of bacterial infections at the point-of-care and their usefulness in providing a hugely beneficial pathway for accurate antibiotic prescribing and thus a novel route to tackling the global challenge of AMR.


Subject(s)
Drug Resistance, Bacterial , Lab-On-A-Chip Devices , Microbial Sensitivity Tests/instrumentation , Paper , Amoxicillin/pharmacology , Anti-Bacterial Agents/pharmacology , Equipment Design , Escherichia coli/drug effects , Escherichia coli Infections/drug therapy , Humans , Lasers
5.
Biosensors (Basel) ; 8(4)2018 Oct 20.
Article in English | MEDLINE | ID: mdl-30347807

ABSTRACT

Paper-based lateral flow devices (LFDs) are regarded as ideal low-cost diagnostic solutions for point-of-care (POC) scenarios that allow rapid detection of a single analyte within a fluidic sample, and have been in common use for a decade. In recent years, there has been an increasing need for rapid and simultaneous detection of multiple analytes present within a single sample and to facilitate this, we report here a novel solution-detection using a multi-path LFD created via the precise partitioning of the single flow-path of a standard LFD using our previously reported laser direct-write (LDW) technique. The multiple flow-paths allow the simultaneous detection of the different analytes individually within each of the parallel channels without any cross-reactivity. The appearance of coloured test lines in individual channels indicates the presence of the different analytes within a sample. We successfully present the use of a LDW-patterned multi-path LFD for multiplexed detection of a biomarker panel comprising C-reactive protein (CRP) and Serum amyloid A-1 (SAA1), used for the diagnosis of bacterial infections. Overall, we demonstrate the use of our LDW technique in the creation of a novel LFD that enables multiplexed detection of two inflammation markers within a single LFD providing a detection protocol that is comparatively more efficient than the standard sequential multiplexing procedure.


Subject(s)
Biomarkers/analysis , Biosensing Techniques/methods , C-Reactive Protein/analysis , Humans , Point-of-Care Systems , Serum Amyloid A Protein/analysis
6.
Biosens Bioelectron ; 113: 95-100, 2018 Aug 15.
Article in English | MEDLINE | ID: mdl-29738945

ABSTRACT

We report on the use of a laser-direct write (LDW) technique that allows the fabrication of lateral flow devices with enhanced sensitivity and limit of detection. This manufacturing technique comprises the dispensing of a liquid photopolymer at specific regions of a nitrocellulose membrane and its subsequent photopolymerisation to create impermeable walls inside the volume of the membrane. These polymerised structures are intentionally designed to create fluidic channels which are constricted over a specific length that spans the test zone within which the sample interacts with pre-deposited reagents. Experiments were conducted to show how these constrictions alter the fluid flow rate and the test zone area within the constricted channel geometries. The slower flow rate and smaller test zone area result in the increased sensitivity and lowered limit of detection for these devices. We have quantified these via the improved performance of a C-Reactive Protein (CRP) sandwich assay on our lateral flow devices with constricted flow paths which demonstrate an improvement in its sensitivity by 62x and in its limit of detection by 30x when compared to a standard lateral flow CRP device.


Subject(s)
Biosensing Techniques/instrumentation , C-Reactive Protein/analysis , Collodion/chemistry , Membranes, Artificial , Microfluidic Analytical Techniques/instrumentation , Equipment Design , Humans , Polymerization , Polymers/chemistry
7.
Biomicrofluidics ; 9(2): 026503, 2015 Mar.
Article in English | MEDLINE | ID: mdl-26015836

ABSTRACT

In this report, we demonstrate a simple and low cost method that can be reproducibly used for fabrication of microfluidic devices in nitrocellulose. The fluidic patterns are created via a laser-based direct-write technique that induces polymerisation of a photo-polymer previously impregnated in the nitrocellulose. The resulting structures form hydrophobic barriers that extend through the thickness of the nitrocellulose and define an interconnected hydrophilic fluidic-flow pattern. Our experimental results show that using this method it is possible to achieve microfluidic channels with lateral dimensions of ∼100 µm using hydrophobic barriers that form the channel walls with dimensions of ∼60 µm; both of these values are considerably smaller than those that can be achieved with other current techniques used in the fabrication of nitrocellulose-based fluidic devices. A simple grid patterned nitrocellulose device was then used for the detection of C-reactive protein via a sandwich enzyme-linked immunosorbent assay, which served as a useful proof-of-principle experiment.

SELECTION OF CITATIONS
SEARCH DETAIL