Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 103
Filter
1.
ACS Appl Mater Interfaces ; 16(36): 47387-47395, 2024 Sep 11.
Article in English | MEDLINE | ID: mdl-39189435

ABSTRACT

Nickel-iron (oxy)hydroxide (NiFeOxHy) stands as a cutting-edge nonprecious electrocatalyst for the oxygen evolution reaction (OER). However, the intrinsic thermodynamic instability of nickel and iron as anode materials in pure water-fed electrolyzers poses a significant durability challenge. In this study, an anion exchange ionomer coating was applied to NiFeOxHy to modify the local pH between a membrane and an electrode. This effectively extended the diffusion length of hydroxide anions toward the electrode, establishing an alkaline local pH environment. Stability tests with the ionomer coating showed reduced Ni dissolution. Moreover, locally resolved current density measurements were used to demonstrate a notably lower degradation rate during stability testing, revealing a 6-fold increase in stability with the ionomer on NiFeOxHy. In situ Raman spectroscopy in a neutral pH electrolyte confirmed inhibited Ni oxidation with the ionomer, mitigating Ni dissolution and enhancing stability of state-of-the-art NiFeOxHy catalysts in pure water-fed water electrolyzers.

2.
Nutrients ; 15(19)2023 10 01.
Article in English | MEDLINE | ID: mdl-37836526

ABSTRACT

BACKGROUND: Since the outbreak of the pandemic started, an increase in the number of sleep disorders, including insomnia and poor sleep quality, has been seen. The pattern will probably continue. METHODS: This study focuses on the preparation and clinical testing of Poria cocos extract in treating suboptimal sleep quality. The optimal extraction method utilized a 75% ethanol concentration, and the clinical investigation involved subjects with defined poor sleep taking 800 mg of the extract nightly, assessed using the Sleep Questionnaire and polysomnography. The non-parametric Wilcoxon signed-rank test was used for statistical analysis due to the non-normal distribution of the collected data. RESULTS: The study involved 21 insomnia sufferers with a mean age of 55 who were administered Poria cocos extracts. The findings of the study indicate a statistically significant rise in the overall duration of sleep (from 327.395 ± 43.2 min to 356.516 ± 63.21 min, p = 0.014). Additionally, there was a notable decrease in the level of arousal during sleep (from 76.316 ± 44.78 min to 47.989 ± 42.38 min, p = 0.009), and an improvement in the sleep severity index of the sleep questionnaire test. CONCLUSIONS: Poria cocos as a natural substance could improve quality of sleep, based on the findings. The study investigates Pachymic acid, a substance found in Poria cocos, as a potential indicator for the development of sleeping aids.


Subject(s)
Drugs, Chinese Herbal , Sleep Initiation and Maintenance Disorders , Wolfiporia , Humans , Middle Aged , Sleep Quality , Functional Food , Sleep Initiation and Maintenance Disorders/drug therapy
3.
Foods ; 12(17)2023 Sep 02.
Article in English | MEDLINE | ID: mdl-37685230

ABSTRACT

Efficient detection methods must be developed for 1,4-dioxane due to its suspected status as a human carcinogen, which is highly mobile in food and environmental resources. In this regard, this experiment has been conducted to develop reliable and selective detection and measurement methods by using static headspace (SH) isolation, followed by gas chromatography-mass spectrometry (GC-MS). A new method was developed for determining the spiked 1,4-dioxane contents in a polyethylene glycol 600 (PEG 600). The optimal condition for SH-GC-MS was discussed. The representative ions of 1,4-dioxane and 1,4-dioxane-d8 in the SIM mode of MS are 88 and 96, respectively, and the peaks of the SIM mode were separated and confirmed. The linear range for the method covers 0.25 to 100 mg/L with a coefficient of determination (R2) ≥ 0.999. The method applicability was demonstrated by spike recovery across a variety of food additives (i.e., chlorine bitartrate, choline chloride, polysorbate 20 and 60, and PEG 1000). All spike recovery from the tested samples was in the range of 89.50-102.68% with a precision of 0.44-11.22%. These findings suggest a new analytical method for food safety inspection, and could be applicable for ensuring the safety of foods and environmental and public health on a broad scale.

4.
Nano Converg ; 10(1): 20, 2023 Apr 30.
Article in English | MEDLINE | ID: mdl-37120780

ABSTRACT

Epitaxy technology produces high-quality material building blocks that underpin various fields of applications. However, fundamental limitations exist for conventional epitaxy, such as the lattice matching constraints that have greatly narrowed down the choices of available epitaxial material combinations. Recent emerging epitaxy techniques such as remote and van der Waals epitaxy have shown exciting perspectives to overcome these limitations and provide freestanding nanomembranes for massive novel applications. Here, we review the mechanism and fundamentals for van der Waals and remote epitaxy to produce freestanding nanomembranes. Key benefits that are exclusive to these two growth strategies are comprehensively summarized. A number of original applications have also been discussed, highlighting the advantages of these freestanding films-based designs. Finally, we discuss the current limitations with possible solutions and potential future directions towards nanomembranes-based advanced heterogeneous integration.

5.
Contemp Clin Trials ; 126: 107108, 2023 03.
Article in English | MEDLINE | ID: mdl-36724841

ABSTRACT

BACKGROUND: Oxiracetam may have a modest effect on preventing cognitive decline. Exercise can also enhance cognitive function. This trial aims to investigate the effect of oxiracetam on post-stroke cognitive impairment and explore whether this effect is modified by exercise. Furthermore, the mechanisms that mediate this effect will be investigated through a neural network analysis. METHODS: This is a multicenter, randomized, double-blind, placebo-controlled phase IV trial. Patients who complained of cognitive decline 3 months after stroke and had a high risk of cognitive decline were eligible. Patients were randomly assigned to receive either 800 mg of oxiracetam or placebo twice daily for 36 weeks. After randomization, a predetermined exercise protocol was provided to each participant, and the degree of physical activity was assessed using wrist actigraphy at 4, 12, 24, and 36 weeks. Resting-state functional MRI was obtained in baseline and 36-week follow-up. Co-primary endpoints are changes in the Mini-Mental State Examination and Clinical Dementia Rating-Sum of Boxes. Secondary endpoints include changes in the NINDS-CSN VCIHS-Neuropsychology Protocol, Euro QoL, patient's global assessment, and functional network connectivity. If there is a significant difference in physical activity between the two groups, the interaction effect between physical activity and the treatment group will be examined. A total of 500 patients were enrolled from February 2018, and the last patient's final follow-up was completed in September 2022. CONCLUSION: This trial is meaningful not only to prove the efficacy of oxiracetam, but also evaluate whether exercise can modify the effects of medication and how cognitive function can be restored. Trial registrationhttp://cris.nih.go.kr (KCT0005137).


Subject(s)
Cognitive Dysfunction , Stroke , Humans , Quality of Life , Cognitive Dysfunction/drug therapy , Pyrrolidines/therapeutic use , Double-Blind Method , Treatment Outcome
6.
Nature ; 614(7946): 81-87, 2023 02.
Article in English | MEDLINE | ID: mdl-36725999

ABSTRACT

Micro-LEDs (µLEDs) have been explored for augmented and virtual reality display applications that require extremely high pixels per inch and luminance1,2. However, conventional manufacturing processes based on the lateral assembly of red, green and blue (RGB) µLEDs have limitations in enhancing pixel density3-6. Recent demonstrations of vertical µLED displays have attempted to address this issue by stacking freestanding RGB LED membranes and fabricating top-down7-14, but minimization of the lateral dimensions of stacked µLEDs has been difficult. Here we report full-colour, vertically stacked µLEDs that achieve, to our knowledge, the highest array density (5,100 pixels per inch) and the smallest size (4 µm) reported to date. This is enabled by a two-dimensional materials-based layer transfer technique15-18 that allows the growth of RGB LEDs of near-submicron thickness on two-dimensional material-coated substrates via remote or van der Waals epitaxy, mechanical release and stacking of LEDs, followed by top-down fabrication. The smallest-ever stack height of around 9 µm is the key enabler for record high µLED array density. We also demonstrate vertical integration of blue µLEDs with silicon membrane transistors for active matrix operation. These results establish routes to creating full-colour µLED displays for augmented and virtual reality, while also offering a generalizable platform for broader classes of three-dimensional integrated devices.

7.
Adv Mater ; 35(1): e2203541, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36281793

ABSTRACT

Hemispherical image sensors simplify lens designs, reduce optical aberrations, and improve image resolution for compact wide-field-of-view cameras. To achieve hemispherical image sensors, organic materials are promising candidates due to the following advantages: tunability of optoelectronic/spectral response and low-temperature low-cost processes. Here, a photolithographic process is developed to prepare a hemispherical image sensor array using organic thin film photomemory transistors with a density of 308 pixels per square centimeter. This design includes only one photomemory transistor as a single active pixel, in contrast to the conventional pixel architecture, consisting of select/readout/reset transistors and a photodiode. The organic photomemory transistor, comprising light-sensitive organic semiconductor and charge-trapping dielectric, is able to achieve a linear photoresponse (light intensity range, from 1 to 50 W m-2 ), along with a responsivity as high as 1.6 A W-1 (wavelength = 465 nm) for a dark current of 0.24 A m-2 (drain voltage = -1.5 V). These observed values represent the best responsivity for similar dark currents among all the reported hemispherical image sensor arrays to date. A transfer method was further developed that does not damage organic materials for hemispherical organic photomemory transistor arrays. These developed techniques are scalable and are amenable for other high-resolution 3D organic semiconductor devices.

8.
Nat Biomed Eng ; 7(4): 511-519, 2023 04.
Article in English | MEDLINE | ID: mdl-35970931

ABSTRACT

By relaying neural signals from the motor cortex to muscles, devices for neurorehabilitation can enhance the movement of limbs in which nerves have been damaged as a consequence of injuries affecting the spinal cord or the lower motor neurons. However, conventional neuroprosthetic devices are rigid and power-hungry. Here we report a stretchable neuromorphic implant that restores coordinated and smooth motions in the legs of mice with neurological motor disorders, enabling the animals to kick a ball, walk or run. The neuromorphic implant acts as an artificial efferent nerve by generating electrophysiological signals from excitatory post-synaptic signals and by providing proprioceptive feedback. The device operates at low power (~1/150 that of a typical microprocessor system), and consists of hydrogel electrodes connected to a stretchable transistor incorporating an organic semiconducting nanowire (acting as an artificial synapse), connected via an ion gel to an artificial proprioceptor incorporating a carbon nanotube strain sensor (acting as an artificial muscle spindle). Stretchable electronics with proprioceptive feedback may inspire the further development of advanced neuromorphic devices for neurorehabilitation.


Subject(s)
Feedback, Sensory , Nanotubes, Carbon , Animals , Mice , Synapses/physiology , Electronics , Motor Neurons
10.
Science ; 377(6608): 859-864, 2022 08 19.
Article in English | MEDLINE | ID: mdl-35981034

ABSTRACT

Recent advances in flexible and stretchable electronics have led to a surge of electronic skin (e-skin)-based health monitoring platforms. Conventional wireless e-skins rely on rigid integrated circuit chips that compromise the overall flexibility and consume considerable power. Chip-less wireless e-skins based on inductor-capacitor resonators are limited to mechanical sensors with low sensitivities. We report a chip-less wireless e-skin based on surface acoustic wave sensors made of freestanding ultrathin single-crystalline piezoelectric gallium nitride membranes. Surface acoustic wave-based e-skin offers highly sensitive, low-power, and long-term sensing of strain, ultraviolet light, and ion concentrations in sweat. We demonstrate weeklong monitoring of pulse. These results present routes to inexpensive and versatile low-power, high-sensitivity platforms for wireless health monitoring devices.


Subject(s)
Monitoring, Physiologic , Remote Sensing Technology , Wearable Electronic Devices , Humans , Monitoring, Physiologic/instrumentation , Pulse , Remote Sensing Technology/instrumentation , Semiconductors , Sweat/chemistry
12.
Sci Adv ; 7(27)2021 Jun.
Article in English | MEDLINE | ID: mdl-34193431

ABSTRACT

Electronic skins (e-skins)-electronic sensors mechanically compliant to human skin-have long been developed as an ideal electronic platform for noninvasive human health monitoring. For reliable physical health monitoring, the interface between the e-skin and human skin must be conformal and intact consistently. However, conventional e-skins cannot perfectly permeate sweat in normal day-to-day activities, resulting in degradation of the intimate interface over time and impeding stable physical sensing. Here, we present a sweat pore-inspired perforated e-skin that can effectively suppress sweat accumulation and allow inorganic sensors to obtain physical health information without malfunctioning. The auxetic dumbbell through-hole patterns in perforated e-skins lead to synergistic effects on physical properties including mechanical reliability, conformability, areal mass density, and adhesion to the skin. The perforated e-skin allows one to laminate onto the skin with consistent homeostasis, enabling multiple inorganic sensors on the skin to reliably monitor the wearer's health over a period of weeks.

14.
Sci Adv ; 5(11): eaav3097, 2019 11.
Article in English | MEDLINE | ID: mdl-31723597

ABSTRACT

Skin-like sensory devices should be stretchable and self-healable to meet the demands for future electronic skin applications. Despite recent notable advances in skin-inspired electronic materials, it remains challenging to confer these desired functionalities to an active semiconductor. Here, we report a strain-sensitive, stretchable, and autonomously self-healable semiconducting film achieved through blending of a polymer semiconductor and a self-healable elastomer, both of which are dynamically cross-linked by metal coordination. We observed that by controlling the percolation threshold of the polymer semiconductor, the blend film became strain sensitive, with a gauge factor of 5.75 × 105 at 100% strain in a stretchable transistor. The blend film is also highly stretchable (fracture strain, >1300%) and autonomously self-healable at room temperature. We proceed to demonstrate a fully integrated 5 × 5 stretchable active-matrix transistor sensor array capable of detecting strain distribution through surface deformation.

15.
Nat Mater ; 18(6): 594-601, 2019 06.
Article in English | MEDLINE | ID: mdl-30988452

ABSTRACT

Stretchable semiconducting polymers have been developed as a key component to enable skin-like wearable electronics, but their electrical performance must be improved to enable more advanced functionalities. Here, we report a solution processing approach that can achieve multi-scale ordering and alignment of conjugated polymers in stretchable semiconductors to substantially improve their charge carrier mobility. Using solution shearing with a patterned microtrench coating blade, macroscale alignment of conjugated-polymer nanostructures was achieved along the charge transport direction. In conjunction, the nanoscale spatial confinement aligns chain conformation and promotes short-range π-π ordering, substantially reducing the energetic barrier for charge carrier transport. As a result, the mobilities of stretchable conjugated-polymer films have been enhanced up to threefold and maintained under a strain up to 100%. This method may also serve as the basis for large-area manufacturing of stretchable semiconducting films, as demonstrated by the roll-to-roll coating of metre-scale films.

16.
Nat Biomed Eng ; 3(1): 58-68, 2019 01.
Article in English | MEDLINE | ID: mdl-30932073

ABSTRACT

Narrowing the mechanical mismatch between tissue and implantable microelectronics is essential for reducing immune responses and for accommodating body movement. However, the design of implantable soft electronics (on the order of 10 kPa in modulus) remains a challenge because of the limited availability of suitable electronic materials. Here, we report electrically conductive hydrogel-based elastic microelectronics with Young's modulus values in the kilopascal range. The system consists of a highly conductive soft hydrogel as a conductor and an elastic fluorinated photoresist as the passivation insulation layer. Owing to the high volumetric capacitance and the passivation layer of the hydrogel, electrode arrays of the thin-film hydrogel 'elastronics', 20 µm in feature size, show a significantly reduced interfacial impedance with tissue, a current-injection density that is ~30 times higher than that of platinum electrodes, and stable electrical performance under strain. We demonstrate the use of the soft elastronic arrays for localized low-voltage electrical stimulation of the sciatic nerve in live mice.


Subject(s)
Elasticity , Electricity , Electronics, Medical/instrumentation , Hydrogels/chemistry , Microtechnology/instrumentation , Animals , Elastic Modulus , Elastomers/chemistry , Electric Conductivity , Electric Stimulation , Halogenation , Male , Mice, Inbred C57BL , Microelectrodes
17.
Sci Adv ; 4(11): eaat7387, 2018 11.
Article in English | MEDLINE | ID: mdl-30480091

ABSTRACT

Emulation of human sensory and motor functions becomes a core technology in bioinspired electronics for next-generation electronic prosthetics and neurologically inspired robotics. An electronic synapse functionalized with an artificial sensory receptor and an artificial motor unit can be a fundamental element of bioinspired soft electronics. Here, we report an organic optoelectronic sensorimotor synapse that uses an organic optoelectronic synapse and a neuromuscular system based on a stretchable organic nanowire synaptic transistor (s-ONWST). The voltage pulses of a self-powered photodetector triggered by optical signals drive the s-ONWST, and resultant informative synaptic outputs are used not only for optical wireless communication of human-machine interfaces but also for light-interactive actuation of an artificial muscle actuator in the same way that a biological muscle fiber contracts. Our organic optoelectronic sensorimotor synapse suggests a promising strategy toward developing bioinspired soft electronics, neurologically inspired robotics, and electronic prostheses.


Subject(s)
Nanowires/chemistry , Neuromuscular Junction/physiology , Neuromuscular Monitoring/instrumentation , Polymers/chemistry , Synapses/physiology , Transistors, Electronic , Wearable Electronic Devices , Electronics , Humans , Models, Neurological
18.
Nat Nanotechnol ; 13(11): 1057-1065, 2018 11.
Article in English | MEDLINE | ID: mdl-30127474

ABSTRACT

Electronic skin devices capable of monitoring physiological signals and displaying feedback information through closed-loop communication between the user and electronics are being considered for next-generation wearables and the 'Internet of Things'. Such devices need to be ultrathin to achieve seamless and conformal contact with the human body, to accommodate strains from repeated movement and to be comfortable to wear. Recently, self-healing chemistry has driven important advances in deformable and reconfigurable electronics, particularly with self-healable electrodes as the key enabler. Unlike polymer substrates with self-healable dynamic nature, the disrupted conducting network is unable to recover its stretchability after damage. Here, we report the observation of self-reconstruction of conducting nanostructures when in contact with a dynamically crosslinked polymer network. This, combined with the self-bonding property of self-healing polymer, allowed subsequent heterogeneous multi-component device integration of interconnects, sensors and light-emitting devices into a single multi-functional system. This first autonomous self-healable and stretchable multi-component electronic skin paves the way for future robust electronics.


Subject(s)
Electric Conductivity , Electronics , Nanostructures , Skin , Electrodes , Electronics/instrumentation , Electronics/methods
19.
Science ; 360(6392): 998-1003, 2018 06 01.
Article in English | MEDLINE | ID: mdl-29853682

ABSTRACT

The distributed network of receptors, neurons, and synapses in the somatosensory system efficiently processes complex tactile information. We used flexible organic electronics to mimic the functions of a sensory nerve. Our artificial afferent nerve collects pressure information (1 to 80 kilopascals) from clusters of pressure sensors, converts the pressure information into action potentials (0 to 100 hertz) by using ring oscillators, and integrates the action potentials from multiple ring oscillators with a synaptic transistor. Biomimetic hierarchical structures can detect movement of an object, combine simultaneous pressure inputs, and distinguish braille characters. Furthermore, we connected our artificial afferent nerve to motor nerves to construct a hybrid bioelectronic reflex arc to actuate muscles. Our system has potential applications in neurorobotics and neuroprosthetics.


Subject(s)
Afferent Pathways , Biomimetic Materials , Neural Prostheses , Mechanoreceptors , Motor Neurons , Muscle Contraction , Muscles/innervation , Muscles/physiology , Pressure , Robotics
20.
Adv Mater ; 30(13): e1706846, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29424026

ABSTRACT

An electronic (e-) skin is expected to experience significant wear and tear over time. Therefore, self-healing stretchable materials that are simultaneously soft and with high fracture energy, that is high tolerance of damage or small cracks without propagating, are essential requirements for the realization of robust e-skin. However, previously reported elastomers and especially self-healing polymers are mostly viscoelastic and lack high mechanical toughness. Here, a new class of polymeric material crosslinked through rationally designed multistrength hydrogen bonding interactions is reported. The resultant supramolecular network in polymer film realizes exceptional mechanical properties such as notch-insensitive high stretchability (1200%), high toughness of 12 000 J m-2 , and autonomous self-healing even in artificial sweat. The tough self-healing materials enable the wafer-scale fabrication of robust and stretchable self-healing e-skin devices, which will provide new directions for future soft robotics and skin prosthetics.


Subject(s)
Elastomers/chemistry , Hydrogen Bonding , Polymers , Water , Wearable Electronic Devices
SELECTION OF CITATIONS
SEARCH DETAIL