Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
9.
10.
Eur J Radiol ; 116: 14-20, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31153555

ABSTRACT

PURPOSE: To assess the effect of intraparenchymal blood patching (IBP) as well as tumor- and operator-related risk factors on the rate of pneumothoraxes after percutaneous CT-guided core needle biopsy of the lung. MATERIALS AND METHODS: We performed a retrospective analysis of 868 CT-guided lung biopsies that were conducted at our institution between 2003 and 2018, of which 419 (48%) received an IBP. Outcome variable included the rates of pneumothorax and chest tube placement, as well as lesion size (<3 cm versus ≥3 cm long axis diameter), lesion depth (≤2 cm, >2-4 cm, >4-5 cm and >5 cm distance to the pleura), location within the lungs (upper lobe, lower lobe, middle lobe), needle caliber (13 G, 15 G, 17 G, 19 G), number of samples taken (1-3 versus ≥4 samples), and experience of the performing physician. RESULTS: The rate of pneumothorax was significantly (p < 0.05) lower in the group with IBP (10.7%) compared to the group without IBP (15.4%). The number of post-interventional chest tube placements was also lower in the IBP group (3.1% vs. 5.8%) but not statistically significant. The lesion size correlated negatively with the rate of pneumothoraxes, whereas in both groups (±IBP) lesions ≥ 3 cm showed a significantly lower rate of pneumothorax (p < 0.05). With increasing lesion depth, the pneumothorax rate increased with (p < 0.01) and without (p < 0.001) IBP. The rate of pneumothorax was significantly lower (p < 0.05) for 17 G needles with IBP, but not for other calibers. For biopsies in the lower lobe, the pneumothorax rate reduced significantly (p < 0.001) with IBP. In case of ≥4 tissue samples, the pneumothorax rate was significantly lower with IBP (p < 0.01). For experienced operators, the overall pneumothorax rate was significantly lower compared to less experienced operators (p < 0001). CONCLUSIONS: IBP significantly reduces the rate of pneumothorax following CT-guided lung biopsies in particular for lesions located deeper in the lungs, when ≥4 samples are taken, when samples are taken by less-experienced operators, and when sampling from the lower lobes.


Subject(s)
Biological Therapy/methods , Lung/pathology , Pneumothorax/epidemiology , Pneumothorax/prevention & control , Radiography, Interventional/methods , Tomography, X-Ray Computed/methods , Adolescent , Adult , Aged , Aged, 80 and over , Biopsy, Large-Core Needle/adverse effects , Chest Tubes/statistics & numerical data , Clinical Competence/statistics & numerical data , Female , Humans , Image-Guided Biopsy/adverse effects , Image-Guided Biopsy/methods , Lung/diagnostic imaging , Male , Middle Aged , Retrospective Studies , Risk Factors , Young Adult
12.
Eur J Radiol ; 104: 129-135, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29857858

ABSTRACT

PURPOSE: To find CT-texture analysis (CTTA) features for the discrimination of splenomegaly due to diffuse lymphoma involvement and liver cirrhosis versus normal-sized spleens in controls and to assess their potential role for longitudinal lymphoma monitoring. MATERIAL AND METHODS: We had retrospectively identified 74 subjects with diffuse splenic involvement due to lymphoma (n = 29) and liver cirrhosis (n = 30), and healthy controls (n = 15), who underwent contrast-enhanced abdominal CT between August 2013 and October 2017. CTTA evaluation included heterogeneity, intensity, average, deviation, skewness, entropy of co-occurrence, number non-uniformity (NGLDM) and entropy NGLDM. A greater than 50% reduction of spleen volume after chemotherapy was considered proof for splenic involvement. RESULTS: There were significant differences of splenic CTTA-values before and after treatment of patients with lymphoma, including mean of entropy(p < .001), uniformity of average(p < .001), uniformity of deviation(p = .002) and entropy of skewness(p < .001). Significant differences of splenic CTTA-values in subjects with lymphoma vs. healthy controls were found for mean intensity(p < .001), mean average(p < .001), and entropy of deviation(p < .001). No significant differences in splenic CTTA-values were found in subjects with lymphoma that reached complete remission vs. controls. Splenic CTTA values mean intensity(p = .002) and mean average(p = .004) were significantly different between subjects with untreated lymphoma and subjects with liver cirrhosis. At end-of-treatment all lymphomas reached complete remission. Entropy/uniformity of heterogeneity(p < .001), mean intensity(p = .007), mean average (p = .007), uniformity of average(p = .008) and mean/entropy/uniformity of skewness(p = .001) measured at this time differed significantly from baseline. CONCLUSIONS: CTTA features in subjects with splenomegaly due to lymphoma and liver cirrhosis differ significantly from those of healthy controls and can be also used for monitoring lymphoma treatment. Quantitative CTTA features may increase the accuracy of diagnosing causes of splenomegaly.


Subject(s)
Liver Cirrhosis/diagnostic imaging , Liver Neoplasms/diagnostic imaging , Lymphoma/diagnostic imaging , Spleen/diagnostic imaging , Splenomegaly/diagnostic imaging , Tomography, X-Ray Computed , Adult , Aged , Aged, 80 and over , Female , Humans , Liver Cirrhosis/complications , Liver Cirrhosis/pathology , Liver Neoplasms/pathology , Lymphoma/pathology , Male , Middle Aged , Retrospective Studies , Spleen/pathology , Splenomegaly/etiology , Splenomegaly/pathology , Young Adult
13.
Eur J Radiol ; 101: 50-58, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29571801

ABSTRACT

PURPOSE: To evaluate the role of CT-textural features for monitoring lung involvement in subjects with systemic sclerosis(SSc) undergoing autologous stem cell transplantation(SCT) by comparison with semi-quantitative chest-CT, pulmonary function tests(PFT) and clinical parameters (modified Rodnan skin score[mRSS]). METHODS: In a retrospective single centre analysis, we identified 23 consecutive subjects(11male) with SSc between 07/2005 and 11/2016 that underwent chest CTs before, 6 and 12 months post-SCT. Response to therapy was defined at 6 months after transplantation as stabilisation or improvement in FVC > 10% and DLCOSB > 10%. CT-texture analysis(CTTA) including mean, entropy and uniformity were calculated. RESULTS: PFT classified the subjects into responders(18/23;78%) and non-responders(5/23;22%). mRSS improved in responders from 28.46 ±â€¯9.53 to 15.70 ±â€¯10.07 6 months after auto-SCT(p = .001) whereas in non-responders no significant improvement was registered. Fibrosis score increased significantly(mean2.33 ±â€¯1.23 vs.1.41 ±â€¯0.78; p = .005) in non-responders after 6 and 12months. Significant lower mean intensity and entropy of skewness and higher uniformity of skewness was found in responders vs. non-responders at baseline. Significant changes in CTTA-parameters were found in both responders and non-responders at 6months and only in responders also at 12months post-SCT. CONCLUSIONS: Changes in CT-textural features after SCT are associated with visual CT evaluation of SSc-related lung abnormalities, but complementary provide information about therapy-induced, structural pulmonary changes.


Subject(s)
Lung Diseases/diagnostic imaging , Scleroderma, Systemic/diagnostic imaging , Adult , Female , Hematopoietic Stem Cell Transplantation , Humans , Lung Diseases/pathology , Lung Diseases/physiopathology , Male , Middle Aged , Radiography, Thoracic/methods , Respiratory Function Tests , Retrospective Studies , Scleroderma, Systemic/pathology , Scleroderma, Systemic/physiopathology , Tomography, X-Ray Computed
15.
Eur J Radiol ; 90: 181-187, 2017 May.
Article in English | MEDLINE | ID: mdl-28583631

ABSTRACT

OBJECTIVES: Analysing the influence of additional carcinoma in situ (CIS) and background parenchymal enhancement (BPE) in preoperative MRI on repeated surgeries in patients with invasive lobular carcinoma (ILC) of the breast. METHODS: Retrospective analysis of 106 patients (mean age 58.6±9.9years) with 108 ILC. Preoperative tumour size as assessed by MRI, mammography and sonography was recorded and compared to histopathology. In contrast-enhanced MRI, the degree of BPE was categorised by two readers. The influence of additionally detected CIS and BPE on the rate of repeated surgeries was analysed. RESULTS: Additional CIS was present in 45.4% of the cases (49/108). The degree of BPE was minimal or mild in 80% of the cases and moderate or marked in 20% of the cases. In 17 cases (15.7%) at least one repeated surgery was performed. In n=15 of these cases, repeated surgery was performed after BCT (n=9 re-excisions, n=6 conversions to mastectomy), in n=2 cases after initial mastectomy. The initial surgical procedure (p=0.008) and additional CIS (p=0.046) significantly influenced the rate of repeated surgeries, while tumour size, patient age and BPE did not (p=ns). CONCLUSIONS: Additional CIS was associated with a higher rate of repeated surgeries, whereas BPE had no influence.


Subject(s)
Breast Neoplasms/diagnostic imaging , Carcinoma in Situ/diagnostic imaging , Carcinoma, Lobular/diagnostic imaging , Magnetic Resonance Imaging/methods , Parenchymal Tissue/diagnostic imaging , Preoperative Care/methods , Reoperation , Adult , Aged , Aged, 80 and over , Breast/diagnostic imaging , Breast/pathology , Breast/surgery , Breast Neoplasms/pathology , Breast Neoplasms/surgery , Carcinoma in Situ/pathology , Carcinoma in Situ/surgery , Carcinoma, Ductal, Breast/pathology , Carcinoma, Lobular/pathology , Carcinoma, Lobular/surgery , Contrast Media , Female , Humans , Image Enhancement/methods , Mammography/methods , Mastectomy/methods , Middle Aged , Parenchymal Tissue/pathology , Parenchymal Tissue/surgery , Retrospective Studies , Sensitivity and Specificity
16.
Rofo ; 188(12): 1163-1168, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27907941

ABSTRACT

Purpose: To evaluate the effects of a new frequency selective non-linear blending (NLB) algorithm on the contrast resolution of liver CT with low intravascular concentration of iodine contrast. Materials and Methods: Our local ethics committee approved this retrospective study. The informed consent requirement was waived. CT exams of 25 patients (60 % female, mean age: 65 ±â€Š16 years of age) with late phase CT scans of the liver were included as a model for poor intrahepatic vascular contrast enhancement. Optimal post-processing settings to enhance the contrast of hepatic vessels were determined. Outcome variables included signal-to-noise (SNR) and contrast-to-noise ratios (CNR) of hepatic vessels and SNR of liver parenchyma of standard and post-processed images. Image quality was quantified by two independent readers using Likert scales. Results: The post-processing settings for the visualization of hepatic vasculature were optimal at a center of 115HU, delta of 25HU, and slope of 5. Image noise was statistically indifferent between standard and post-processed images. The CNR between the hepatic vasculature (HV) and liver parenchyma could be significantly increased for liver veins (CNRStandard 1.62 ±â€Š1.10, CNRNLB 3.6 ±â€Š2.94, p = 0.0002) and portal veins (CNRStandard 1.31 ±â€Š0.85, CNRNLB 2.42 ±â€Š3.03, p = 0.046). The SNR of liver parenchyma was significantly higher on post-processed images (SNRNLB 11.26 ±â€Š3.16, SNRStandard 8.85 ± 2.27, p = 0.008). The overall image quality and depiction of HV were significantly higher on post-processed images (NLBDHV: 4 [3 - 4.75], StandardDHV: 2 [1.3 - 2.5], p = < 0.0001; NLBIQ: 4 [4 - 4], StandardIQ: 2 [2 - 3], p = < 0.0001). Conclusion: The use of a frequency selective non-linear blending algorithm increases the contrast resolution of liver CT and can improve the visibility of the hepatic vasculature in the setting of a low contrast ratio between vessels and the parenchyma. Key Points: • Using the new frequency selective non-linear blending algorithm is feasible in contrast-enhanced liver CT.• Optimal post-processing settings make it possible to significantly increase the contrast resolution of liver CT without affecting image noise.• Especially in low contrast CT images, the novel algorithm is capable of significantly increasing image quality. Citation Format: • Bongers MN, Bier G, Kloth C et al. Frequency Selective Non-Linear Blending to Improve Image Quality in Liver CT. Fortschr Röntgenstr 2016; 188: 1163 - 1168.


Subject(s)
Algorithms , Hepatic Artery/diagnostic imaging , Hepatic Veins/diagnostic imaging , Liver/diagnostic imaging , Radiographic Image Enhancement/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Liver/blood supply , Male , Middle Aged , Nonlinear Dynamics , Radiographic Image Interpretation, Computer-Assisted/methods , Reproducibility of Results , Sensitivity and Specificity
17.
Eur J Radiol ; 85(11): 2036-2041, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27776657

ABSTRACT

PURPOSE: To evaluate whether VEGFR-2-expression in hepatocellular carcinoma (HCC), dysplastic (DLN) and regenerative liver nodules (RLN) correlates with pre-histology, in vivo Dynamic Contrast Enhanced-Computed Tomography (DCE-CT) data as VEGFR-2-expression affects prognosis and therapeutic options. MATERIALS AND METHODS: 34 patients (63.6±8.9years, 7 females) underwent liver biopsy or surgery due to suspected HCC or dysplastic nodules after DCE-CT between 2009 and 2015 with no previous chemo- or interventional therapy. Immunohistochemistry staining for VEGFR-2 was performed using Immunoreactive-Remmele-Stegner-Score (IRS) for quantification. A 128-row CT-scanner was used for DCE-CT with assessment of perfusion parameters blood flow (BF), blood volume (BV), arterial liver perfusion (ALP), portal venous perfusion (PVP), and hepatic perfusion index (HPI). RESULTS: Histology confirmed HCC (n=10), DLN (n=7) and RLN (n=34). Mean IRS for VEGFR-2 in HCCs was 9.1±3.0, 7.3±1.6 for DLN and 5.2±2.8 for RLN (p=0.0004 for HCC vs. RLN). Perfusion values varied significantly between all three groups for BF and HPI (p<0.001 and p<0.0001) and for BV in HCC vs. RLN (p<0.0001) and DLN vs. RLN (p=0.0019). Strong correlations between VEGFR-2-IRS and perfusion parameters were observed for BF in HCC (r=0.88, p<0.01) and HPI in HCC and DLN (r=0.85, p<0.04; r=0.9, p<0.01). CONCLUSION: Immunostaining revealed different VEGFR-2-expression levels in HCC, dysplastic and regenerative liver nodules. Perfusion markers blood flow, blood volume and hepatic perfusion index correlated well with VEGFR-2-immunostaining. This non-invasive discrimination between regenerative and dysplastic/HCC nodules might open new perspectives for diagnosis, therapy planning, and anti-VEGFR therapy monitoring.


Subject(s)
Carcinoma, Hepatocellular/metabolism , Liver Neoplasms/metabolism , Liver Regeneration , Liver/diagnostic imaging , Liver/metabolism , Tomography, Spiral Computed/methods , Vascular Endothelial Growth Factor Receptor-2/metabolism , Aged , Biopsy , Blood Volume , Carcinoma, Hepatocellular/blood supply , Carcinoma, Hepatocellular/diagnostic imaging , Carcinoma, Hepatocellular/surgery , Female , Humans , Immunohistochemistry , Liver/pathology , Liver/surgery , Liver Neoplasms/blood supply , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/surgery , Male , Middle Aged , Perfusion Imaging , Prognosis , ROC Curve , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...