Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
1.
Food Microbiol ; 116: 104370, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37689421

ABSTRACT

Alternaria is one of the main fungal contaminants of cereal grains worldwide with the potential to produce mycotoxins hazardous to human and animal health. Many studies have been carried out to characterize Alternaria sp.-grp. using traditional morphology or polyphasic approach, but a good correlation between morphological sp.-grp., molecular, and chemotaxonomic groups has not always been achieved. For this reason, this study aimed to investigate the usefulness of a cheaper alternative tool, SRAP markers, in identifying Alternaria sp.-grps. obtained from Argentinean barley grains and to compare it with preliminary characterization using morphological traits, phylogeny, and metabolite profiles. Fifty-three Alternaria isolates from barley grains of the main producing regions of Argentina were analyzed with four combinations of SRAP markers. The UPGMA dendrogram, based on the Simple Matching similarity coefficient, revealed three distinct groups. SRAP markers allowed the separation of Alternaria from Infectoriae sections in agreement with the results of a polyphasic approach previously made. Besides, isolates of A. arborescens sp.-grp. were clustered in a separate group from isolates of A. tenuissima and A. alternata sp.-grp., which were grouped in the same cluster. SRAP markers are a recommended tool for classifying Alternaria isolates because of its simplicity, reliability, and cost-effectiveness compared to other molecular markers.


Subject(s)
Alternaria , Mycotoxins , Animals , Humans , Reproducibility of Results , Argentina , Edible Grain
2.
Phys Med ; 106: 102518, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36638707

ABSTRACT

PURPOSE: Accurate dosimetry is paramount to study the FLASH biological effect since dose and dose rate are critical dosimetric parameters governing its underlying mechanisms. With the goal of assessing the suitability of standard clinical dosimeters in a very-high dose rate (VHDR) experimental setup, we evaluated the ion collection efficiency of several commercially available air-vented ionization chambers (IC) in conventional and VHDR proton irradiation conditions. METHODS: A cyclotron at the Orsay Proton Therapy Center was used to deliver VHDR pencil beam scanning irradiation. Ion recombination correction factors (ks) were determined for several detectors (Advanced Markus, PPC05, Nano Razor, CC01) at the entrance of the plateau and at the Bragg peak, using the Niatel model, the Two-voltage method and Boag's analytical formula for continuous beams. RESULTS: Mean dose rates ranged from 4 Gy/s to 385 Gy/s, and instantaneous dose rates up to 1000 Gy/s were obtained with the experimental set-up. Recombination correction factors below 2 % were obtained for all chambers, except for the Nano Razor, at VHDRs with variations among detectors, while ks values were significantly smaller (0.8 %) for conventional dose rates. CONCLUSIONS: While the collection efficiency of the probed ICs in scanned VHDR proton therapy is comparable to those in the conventional regime with recombination coefficiens smaller than 1 % for mean dose rates up to 177 Gy/s, the reduction in collection efficiency for higher dose rates cannot be ignored when measuring the absorbed dose in pre-clinical proton scanned FLASH experiments and clinical trials.


Subject(s)
Proton Therapy , Protons , Radiometry/methods , Proton Therapy/methods , Cyclotrons , Radiation Dosimeters
3.
Phys Med ; 104: 149-159, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36427487

ABSTRACT

PURPOSE: In order to translate the FLASH effect in clinical use and to treat deep tumors, Very High Electron Energy irradiations could represent a valid technique. Here, we address the main issues in the design of a VHEE FLASH machine. We present preliminary results for a compact C-band system aiming to reach a high accelerating gradient and high current necessary to deliver a Ultra High Dose Rate with a beam pulse duration of 3µs. METHODS: The proposed system is composed by low energy high current injector linac followed by a high acceleration gradient structure able to reach 60-160 MeV energy range. To obtain the maximum energy, an energy pulse compressor options is considered. CST code was used to define the specifications RF parameters of the linac. To optimize the accelerated current and therefore the delivered dose, beam dynamics simulations was performed using TSTEP and ASTRA codes. RESULTS: The VHEE parameters Linac suitable to satisfy FLASH criteria were simulated. Preliminary results allow to obtain a maximum energy of 160 MeV, with a peak current of 200 mA, which corresponds to a charge of 600 nC. CONCLUSIONS: A promising preliminary design of VHEE linac for FLASH RT has been performed. Supplementary studies are on going to complete the characterization of the machine and to manufacture and test the RF prototypes.


Subject(s)
Particle Accelerators
4.
Cancer Radiother ; 25(6-7): 554-564, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34272182

ABSTRACT

In the current spectrum of cancer treatments, despite high costs, a lack of robust evidence based on clinical outcomes or technical and radiobiological uncertainties, particle therapy and in particular proton therapy (PT) is rapidly growing. Despite proton therapy being more than fifty years old (first proposed by Wilson in 1946) and more than 220,000 patients having been treated with in 2020, many technological challenges remain and numerous new technical developments that must be integrated into existing systems. This article presents an overview of on-going technical developments and innovations that we felt were most important today, as well as those that have the potential to significantly shape the future of proton therapy. Indeed, efforts have been done continuously to improve the efficiency of a PT system, in terms of cost, technology and delivery technics, and a number of different developments pursued in the accelerator field will first be presented. Significant developments are also underway in terms of transport and spatial resolution achievable with pencil beam scanning, or conformation of the dose to the target: we will therefore discuss beam focusing and collimation issues which are important parameters for the development of these techniques, as well as proton arc therapy. State of the art and alternative approaches to adaptive PT and the future of adaptive PT will finally be reviewed. Through these overviews, we will finally see how advances in these different areas will allow the potential for robust dose shaping in proton therapy to be maximised, probably foreshadowing a future era of maturity for the PT technique.


Subject(s)
Forecasting , Neoplasms/radiotherapy , Proton Therapy/trends , Cancer Care Facilities , Cyclotrons , Humans , Neutron Activation Analysis , Organ Sparing Treatments/instrumentation , Organ Sparing Treatments/methods , Organs at Risk , Proton Therapy/economics , Proton Therapy/instrumentation , Proton Therapy/methods , Quality Assurance, Health Care , Radiotherapy, Image-Guided/trends , Synchrotrons
5.
Cancer Radiother ; 24(6-7): 691-698, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32753235

ABSTRACT

Prescription and delivery of protons are somewhat different compared to photons and may influence outcomes (tumour control and toxicity). These differences should be taken into account to fully exploit the clinical potential of proton therapy. Innovations in proton therapy treatment are also required to widen the therapeutic window and determine appropriate populations of patients that would benefit from new treatments. Therefore, strategies are now being developed to reduce side effects to critical normal tissues using alternative treatment configurations and new spatial or temporal-driven optimisation approaches. Indeed, spatiotemporal optimisation (based on flash, proton minibeam radiation therapy or hypofractionated delivery methods) has been gaining some attention in proton therapy as a mean of improving (biological and physical) dose distribution. In this short review, the main differences in planning and delivery between protons and photons, as well as some of the latest developments and methodological issues (in silico modelling) related to providing scientific evidence for these new techniques will be discussed.


Subject(s)
Brain Neoplasms/radiotherapy , Proton Therapy/methods , Humans , Radiotherapy Dosage/standards , Radiotherapy Planning, Computer-Assisted , Spatio-Temporal Analysis
6.
Sci Rep ; 10(1): 7025, 2020 04 27.
Article in English | MEDLINE | ID: mdl-32341427

ABSTRACT

Proton minibeam radiation therapy (pMBRT) is a novel dose delivery method based on spatial dose fractionation. pMBRT has been shown to be promising in terms of reduced side effects and superior tumour control in high-grade glioma-bearing rats compared to standard irradiation. These findings, together with the recent optimized implementation of pMBRT in a clinical pencil beam scanning system, have triggered reflection on the possible application to patient treatments. In this context, the present study was designed to conduct a first theoretical investigation of the clinical potential of this technique. For this purpose, a dedicated dose engine was developed and used to evaluate two clinically relevant patient treatment plans (high-grade glioma and meningioma). Treatment plans were compared with standard proton therapy plans assessed by means of a commercial treatment planning system (ECLIPSE-Varian Medical systems) and Monte Carlo simulations. A multislit brass collimator consisting of 0.4 mm wide slits separated by a centre-to-centre distance of 4 or 6 mm was placed between the nozzle and the patient to shape the planar minibeams. For each plan, spread-out Bragg peaks and homogeneous dose distributions (±7% dose variations) can be obtained in target volumes. The Peak-to-Valley Dose Ratios (PVDR) were evaluated between 9.2 and 12.8 at a depth of 20 mm for meningioma and glioma, respectively. Dose volume histograms (DVHs) for target volumes and organs at risk were quantitatively compared, resulting in a slightly better target homogeneity with standard PT than with pMBRT plans, but similar DVHs for deep-seated organs-at-risk and lower average dose for shallow organs. The proposed delivery method evaluated in this work opens the way to an effective treatment for radioresistant tumours and will support the design of future clinical research.


Subject(s)
Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy/methods , Brain Neoplasms/radiotherapy , Glioma/radiotherapy , Humans , Linear Energy Transfer , Monte Carlo Method , Protons , Radiotherapy Dosage
7.
Phys Med ; 64: 195-203, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31515020

ABSTRACT

The aim of this work is to perform Monte Carlo simulations of a proton pencil beam scanning machine, characterise the low-dose envelope of scanned proton beams and assess the differences between various approximations for nozzle geometry. Measurements and Monte Carlo simulations were carried out in order to describe the dose distribution of a proton pencil beam in water for energies between 100 and 220 MeV. Dose distributions were simulated by using a Geant4 Monte Carlo platform (TOPAS), and were measured in water using a two-dimensional ion chamber array detector. The beam source in air was adjusted for each configuration. Double Gaussian parameterisation was proposed for definition of the beam source model in order to improve simulations starting at the nozzle exit. Absolute dose distributions and field size factors were measured and compared with simulations. The influence of the high-density components present in the treatment nozzle was also investigated by analysis of proton phase spaces at the nozzle exit. An excellent agreement was observed between experimental dose distributions and simulations for energies higher than 160 MeV. However, minor differences were observed between 100 and 160 MeV, suggesting poorer modelling of the beam when the full treatment head was not taken into account. We found that the first ionisation chamber was the main cause of the tail component observed for low proton beam energies. In this work, various parameterisations of proton sources were proposed, thereby allowing reproduction of the low-dose envelope of proton beams and excellent agreement with measured data.


Subject(s)
Monte Carlo Method , Proton Therapy/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
8.
Cancer Radiother ; 23(6-7): 677-681, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31494038

ABSTRACT

In radiation therapy, a renewed interest is emerging for the study of spatially fractionated irradiation. In this article, a few applications using spatial fractionation of the dose will be discussed with a focus on proton minibeam radiation therapy. Examples of calculated dose (1D profiles and 2D dose distributions) and biological evidence obtained so far will be presented for various spatially fractionated techniques GRID, micro- and minibeam radiation therapy. Recent results demonstrating that proton minibeam radiation therapy leads to an increase in normal tissues sparing will be discussed, which opens the door to a dose escalation in the tumour and a possibly efficient treatment of very radioresistant tumours.


Subject(s)
Dose Fractionation, Radiation , Neoplasms/radiotherapy , Organs at Risk/radiation effects , Proton Therapy/methods , Animals , Humans , Radiation Injuries/prevention & control , Radiation Tolerance , Rats
9.
Phys Med Biol ; 63(20): 205016, 2018 10 17.
Article in English | MEDLINE | ID: mdl-30203783

ABSTRACT

Proton transmission imaging uses protons with high enough energy to fully traverse the phantom/patient and to be captured in a suitable detector placed behind it. The measured residual energy or residual range provide a direct estimate of the water equivalent thickness (WET) of the image volume. Requirements for proton imaging to be exploitable in clinical practice include: sufficient WET accuracy and integrability into the treatment room and the clinical workflow, as well as an acceptably low dose to the patient and a sufficient spatial resolution. In this work, we report on experiments performed at the Institut Curie-Proton therapy center in Orsay (IC-CPO), France, using a commercial range telescope commonly employed for quality assurance measurements. The purpose was to keep the experimental set-up as simple as possible and to achieve nonetheless high WET accuracy radiographies by developing and applying dedicated post processing methods. We explain these methods in detail and discuss their performance. We assess the WET accuracy based on two different reference phantoms: a CIRS electron density phantom with tissue equivalent inserts and a homogeneous step phantom. We find an agreement between the measured and the reference WET values of 0.2-0.5 mm. The lowest investigated dose was 10 mGy per acquisition. It could be lowered by modifying the irradiation plan and lowering the beam current, though the latter would impose slight optimisations of the detector hardware. Our work suggests that proton radiographies with good WET accuracy can be obtained with a reasonable experimental effort that would facilitate integration into clinical routine.


Subject(s)
Image Processing, Computer-Assisted , Protons , Radiography/instrumentation , Telescopes , Humans , Phantoms, Imaging , Quality Control , Water
11.
Rev Sci Instrum ; 88(11): 113301, 2017 Nov.
Article in English | MEDLINE | ID: mdl-29195357

ABSTRACT

Responses of Fuji Imaging Plates (IPs) to proton have been measured in the range 1-200 MeV. Mono-energetic protons were produced with the 15 MV ALTO-Tandem accelerator of the Institute of Nuclear Physics (Orsay, France) and, at higher energies, with the 200-MeV isochronous cyclotron of the Institut Curie-Centre de Protonthérapie d'Orsay (Orsay, France). The experimental setups are described and the measured photo-stimulated luminescence responses for MS, SR, and TR IPs are presented and compared to existing data. For the interpretation of the results, a sensitivity model based on the Monte Carlo GEANT4 code has been developed. It enables the calculation of the response functions in a large energy range, from 0.1 to 200 MeV. Finally, we show that our model reproduces accurately the response of more complex detectors, i.e., stack of high-Z filters and IPs, which could be of great interest for diagnostics of Petawatt laser accelerated particles.

12.
Phys Med Biol ; 61(17): 6413-29, 2016 09 07.
Article in English | MEDLINE | ID: mdl-27499356

ABSTRACT

Small diamond detectors are useful for the dosimetry of high-energy proton beams. However, linear energy transfer (LET) dependence has been observed in the literature with such solid state detectors. A novel synthetic diamond detector has recently become commercially available from the manufacturer PTW-Freiburg (PTW microDiamond type 60019). This study was designed to thoroughly characterize four microDiamond detectors in clinical proton beams, in order to investigate their response and their reproducibility in high LET regions. Very good dosimetric characteristics were observed for two of them, with good stability of their response (deviation less than 0.4% after a pre-irradiation dose of approximately 12 Gy), good repeatability (coefficient of variation of 0.06%) and a sensitivity of approximately 0.85 nC Gy(-1). A negligible dose rate dependence was also observed for these two microDiamonds with a deviation of the sensitivity less than 0.7% with respect to the one measured at the reference dose rate of 2.17 Gy min(-1), in the investigated dose rate range from 1.01 Gy min(-1) to 5.52 Gy min(-1). Lateral dose profile measurements showed the high spatial resolution of the microDiamond oriented with its stem perpendicular to the beam axis and with its small sensitive thickness of about 1 µm in the scanning profile direction. Finally, no significant LET dependence was found with these two diamond dosimeters in comparison to a reference ionization chamber (model IBA PPC05). These good results were in accordance to the literature. However, this study showed also a non reproducibility between the devices in terms of stability, sensitivity and LET dependence, since the two other microDiamonds characterized in this work showed different dosimetric characteristics making them not suitable for proton beam dosimetry with a maximum difference of the peak-to-plateau ratio of 6.7% relative to the reference ionization chamber in a clinical 138 MeV proton beam.


Subject(s)
Proton Therapy/methods , Radiation Dosimeters/standards , Diamond/chemistry , Diamond/radiation effects , Linear Energy Transfer , Proton Therapy/instrumentation , Proton Therapy/standards , Radiometry/instrumentation , Radiometry/methods
13.
Med Phys ; 42(12): 7108-13, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26632064

ABSTRACT

PURPOSE: Proton minibeam radiation therapy (pMBRT) is a new radiotherapy (RT) approach that allies the inherent physical advantages of protons with the normal tissue preservation observed when irradiated with submillimetric spatially fractionated beams. This dosimetry work aims at demonstrating the feasibility of the technical implementation of pMBRT. This has been performed at the Institut Curie - Proton Therapy Center in Orsay. METHODS: Proton minibeams (400 and 700 µm-width) were generated by means of a brass multislit collimator. Center-to-center distances between consecutive beams of 3200 and 3500 µm, respectively, were employed. The (passive scattered) beam energy was 100 MeV corresponding to a range of 7.7 cm water equivalent. Absolute dosimetry was performed with a thimble ionization chamber (IBA CC13) in a water tank. Relative dosimetry was carried out irradiating radiochromic films interspersed in a IBA RW3 slab phantom. Depth dose curves and lateral profiles at different depths were evaluated. Peak-to-valley dose ratios (PVDR), beam widths, and output factors were also assessed as a function of depth. RESULTS: A pattern of peaks and valleys was maintained in the transverse direction with PVDR values decreasing as a function of depth until 6.7 cm. From that depth, the transverse dose profiles became homogeneous due to multiple Coulomb scattering. Peak-to-valley dose ratio values extended from 8.2 ± 0.5 at the phantom surface to 1.08 ± 0.06 at the Bragg peak. This was the first time that dosimetry in such small proton field sizes was performed. Despite the challenge, a complete set of dosimetric data needed to guide the first biological experiments was achieved. CONCLUSIONS: pMBRT is a novel strategy in order to reduce the side effects of RT. This works provides the experimental proof of concept of this new RT method: clinical proton beams might allow depositing a (high) uniform dose in a brain tumor located in the center of the brain (7.5 cm depth, the worst scenario), while a spatial fractionation of the dose is retained in the normal tissues in the beam path, potentially leading to a gain in tissue sparing. This is the first complete experimental implementation of this promising technique. Biological experiments are needed in order to confirm the clinical potential of pMBRT.


Subject(s)
Proton Therapy/methods , Feasibility Studies , Phantoms, Imaging , Proton Therapy/instrumentation , Radiometry/instrumentation , Radiometry/methods , Radiotherapy Dosage , Water
14.
Int J Food Microbiol ; 154(3): 187-91, 2012 Mar 15.
Article in English | MEDLINE | ID: mdl-22285534

ABSTRACT

Blueberries are traditionally consumed in North America, some European countries and Japan. In Argentina, the blueberry crop is profitable because production starts in November, when the northern hemisphere lacks fresh fruit. Fungal contaminants can grow and produce mycotoxins in fresh fruit. The aims of this work were to identify the main genera of the mycobiota of blueberries grown in Argentina and to determine the toxicogenic potential, pathogenicity and host specificity of the species isolated. The genus Alternaria was the main component of the blueberry mycobiota (95%); minor proportions of Phoma spp. (4%) and Penicillium spp. (1%) were also isolated. According to their sporulation patterns, 127 Alternaria isolates belonged to the Alternaria tenuissima species-group, 5 to the Alternaria alternata species-group and 2 to the Alternaria arborescens species-group. The last mentioned species-group was not isolated at 5°C. Of the 134 isolates, 61% were toxicogenic in autoclaved rice; 97% of these produced alternariol (AOH) in a range from 0.14 to 119.18 mg/kg, 95% produced alternariol methylether (AME) in a range from 1.23 to 901.74 mg/kg and 65% produced tenuazonic acid (TA) in a range from 0.13 to 2778 mg/kg. Fifty two isolates co-produced the three mycotoxins. According to the size of the lesion that they caused on blueberries, the isolates were classified as slightly pathogenic, moderately pathogenic and very pathogenic. No significant differences in pathogenicity were found on different blueberry varieties. In this work, high incidence and toxicogenic potential of the Alternaria isolates from blueberries were demonstrated. Thus, more studies should be done to evaluate the health risk posed by the presence of the Alternaria toxins in blueberries and in the manufactured by-products.


Subject(s)
Alternaria/pathogenicity , Blueberry Plants/microbiology , Mycotoxins/biosynthesis , Alternaria/isolation & purification , Argentina , Food Storage
15.
Food Microbiol ; 28(8): 1463-7, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21925029

ABSTRACT

Sorbitol and xylitol are polyols often used in foods as naturally occurring sugar substitutes. They provide sweet taste and reduced calories in products of intermediate moisture. This type of food is susceptible to spoilage by xerophilic molds which affect shelf life of foods and produce significant losses. The aim of the present work was to study the effect of glycerol, sorbitol and xylitol on the germination and growth of four xerophilic fungi at different temperatures and water activity levels. Penicillium chrysogenum, Wallemia sebi, Eurotium chevalieri and Eurotium repens were cultivated on malt extract agar with the addition of the respective polyols and a(w) adjusted to 0.85, 0.88, 0.90 and 0.93. Incubation was made at 25, 30 and 35 °C. Results of the present study demonstrated that sorbitol and xylitol affect the growth kinetics of the four fungal species. The observed tendency was that these solutes shortened the germination times and increased the growth rates. The effect of each solute depended on the fungal species and the a(w)/temperature combinations. At lower a(w) the influence was more evident on the germination times while the effect on growth rates was more pronounced at higher a(w) levels.


Subject(s)
Fungi/metabolism , Sorbitol/metabolism , Spores, Fungal/growth & development , Xylitol/metabolism , Culture Media/metabolism , Fungi/chemistry , Fungi/growth & development , Kinetics , Spores, Fungal/chemistry , Spores, Fungal/metabolism , Temperature
16.
Int J Food Microbiol ; 142(3): 348-53, 2010 Sep 01.
Article in English | MEDLINE | ID: mdl-20688408

ABSTRACT

Alternaria spp. have been reported to be the most frequent fungal species invading tomatoes. Certain species, in particular the most common one, A. alternata, are capable of producing several mycotoxins in infected plants and in agricultural commodities. Alternariol (AOH), alternariol monomethyl ether (AME), and tenuazonic acid (TA) are some of the main Alternaria mycotoxins that can be found as contaminants of food. The objective of this study was to determine the effect of water activity (a(w), 0.904, 0.922, 0.954, and 0.982) and temperature (6, 15, 21 and 35 degrees C) on mycotoxin production on a synthetic tomato medium of a cocktail inoculum of five strains of A. alternata isolated from tomato fruits affected by Blackmould. The optimum AOH production occurred at 0.954 a(w) after 28days of incubation at 21 degrees C. A temperature of 21 degrees C was the most favourable for AOH synthesis at all a(w) levels. The maximum concentration of AME was determined at 0.954 a(w) and 35 degrees C. The optimum conditions for TA accumulation were 0.982 a(w) and 21 degrees C. At the 0.904 a(w) no growth or germination was registered at 6 degrees C and 15 degrees C over the whole incubation period. At 21 degrees C and 35 degrees C growth occurred slowly but none of the toxins were detected at this a(w) level. In general, high a(w) levels were favourable for mycotoxin production. None of the other toxins was detected at quantifiable levels at 6 degrees C after the whole incubation period. A storage temperature of 6 degrees C or below could be considered as safe for tomato fruits and high moisture tomato products (a(w)>0.95), in relation with Alternaria toxins. The results obtained here could be extrapolated to evaluate the risk of spoilage in tomato fruits and tomato products caused by this pathogen.


Subject(s)
Alternaria/metabolism , Food Preservation/methods , Mycotoxins/biosynthesis , Temperature , Water/metabolism , Alternaria/growth & development , Colony Count, Microbial , Consumer Product Safety , Culture Media , Food Contamination/analysis , Lactones/analysis , Lactones/metabolism , Solanum lycopersicum/chemistry , Solanum lycopersicum/microbiology
17.
Int J Food Microbiol ; 135(1): 60-3, 2009 Sep 30.
Article in English | MEDLINE | ID: mdl-19683824

ABSTRACT

Alternaria alternata is a toxigenic fungus, predominantly responsible for Blackmould of ripe tomato fruits, a disease frequently causing substantial losses of tomatoes, especially those used for canning. The objective of this study was to determine the effect of water activity (a(w), 0.904, 0.922, 0.954, 0.982) and temperature (6, 15, 21 and 35 degrees C) on germination and radial growth rate on a synthetic tomato medium of a cocktail inoculum of five strains of A. alternata isolated from tomato fruits affected by Blackmould. The shortest germination time (1.5 days) was observed at 0.982 a(w), both at 21 degrees C and 35 degrees C. The germination time increased with a reduction on a(w). The fastest growth rate was registered at 0.982 a(w) and 21 degrees C (8.31 mm/day). Growth rates were higher when a(w) increased. No growth or germination was observed at the lowest a(w) level evaluated (0.904) after 100 days of incubation at 6 degrees C and 15 degrees C. A temperature of 6 degrees C caused a significant reduction in growth rates, even at the optimum a(w) level. The knowledge on the ecophysiology of the fungus in this substrate is necessary to elaborate future strategies to prevent its development and evaluate the consumer health risk.


Subject(s)
Alternaria/growth & development , Food Preservation/methods , Solanum lycopersicum/microbiology , Temperature , Water/metabolism , Alternaria/metabolism , Argentina , Colony Count, Microbial , Consumer Product Safety , Food Contamination/analysis , Food Contamination/prevention & control , Food Microbiology , Kinetics , Mycotoxins/biosynthesis , Time Factors
18.
J Food Prot ; 71(6): 1262-5, 2008 Jun.
Article in English | MEDLINE | ID: mdl-18592757

ABSTRACT

The natural occurrence of Alternaria mycotoxins in Argentinean wheat from the zone 5 South during the 2004 to 2005 harvest was investigated in 64 wheat samples. All samples were highly contaminated with a wide range of fungal species. Alternaria was found as the main component of the mycota, with an infection percentage of 100%. Three mycotoxins produced by species of Alternaria were determined in wheat: alternariol, alternariol monomethyl ether, and tenuazonic acid. Alternariol was detected in 4 (6%) of 64 samples, with a range of 645 to 1,388 microg/kg (mean of 1,054 microg/kg); alternariol monomethyl ether, with a range of 566 to 7,451 microg/kg (mean of 2,118 microg/kg) in 15 (23%) of 64 samples; and tenuazonic acid in 12 (19%) of 64 samples, with a range of 1,001 to 8,814 microg/kg (mean, 2,313 microg/kg). Alternariol monomethyl ether was the predominant toxin, but tenuazonic acid was detected in higher concentrations. Alternariol was present in fewer samples and in lower levels than were the other toxins. Tenuazonic acid and alternariol monomethyl ether occurred together in four samples, while tenuazonic acid and alternariol co-occurred in one sample. This the first report of the natural occurrence of Alternaria mycotoxins in Argentinean wheat. Toxin levels were high, probably due to the heavy infection with Alternaria species found in the samples.


Subject(s)
Alternaria/metabolism , Food Contamination/analysis , Mycotoxins/analysis , Triticum/chemistry , Argentina/epidemiology , Colony Count, Microbial , Consumer Product Safety , Food Microbiology , Humans , Lactones/analysis , Mycotoxins/biosynthesis , Prevalence , Species Specificity , Tenuazonic Acid/analysis , Tenuazonic Acid/biosynthesis
19.
Int J Food Microbiol ; 119(3): 219-22, 2007 Nov 01.
Article in English | MEDLINE | ID: mdl-17804107

ABSTRACT

The toxigenic potential of Alternaria strains isolated from Argentinean wheat was investigated. A total of 123 strains were assayed for the production of tenuazonic acid (TA), alternariol (AOH) and alternariol monomethyl ether (AME). All but one of the isolates were able to produce at least one of the three mycotoxins. TA was produced by 72% of the strains (1-14782 mg/kg), AOH by 87% (4-622 mg/kg) and AME by 91% (7-2625 mg/kg). The average level of TA detected for all strains (1757 mg/kg) was higher than the average level of both alternariols (162 mg/kg for AOH and 620 mg/kg for AME). TA was the toxin produced at the highest concentration but in lower frequency. Most of the strains were able to synthesize more than one toxin: 74 isolates (60%) were positive for all three toxins, 30 (24%) for both AOH and AME, 5 (4%) for both TA and AME, and 2 (2%) for TA and AOH. The widespread occurrence of Alternaria in wheat and its ability to produce mycotoxins suggests the possible occurrence of its toxins in wheat naturally infected with this fungus.


Subject(s)
Alternaria/metabolism , Food Contamination/analysis , Mycotoxins/biosynthesis , Triticum/microbiology , Alternaria/classification , Alternaria/growth & development , Argentina/epidemiology , Chromatography, High Pressure Liquid , Food Microbiology , Lactones/analysis , Mycotoxins/analysis , Prevalence , Species Specificity , Tenuazonic Acid/analysis , Time Factors , Triticum/chemistry
20.
Int J Food Microbiol ; 115(2): 140-3, 2007 Apr 10.
Article in English | MEDLINE | ID: mdl-17161486

ABSTRACT

Aspergillus carbonarius is an ochratoxin A (OTA) producing fungus, predominantly responsible for the production of this mycotoxin in grapes, wine and dried vine fruits. The objective of this study was to determine the in vitro effects of water activity (a(w), 0.80-0.95) and temperature (15-35 degrees C) on lag phase extension and radial growth rate of a cocktail inoculum of four strains of A. carbonarius. The maximum growth rate was observed at 0.95 a(w) and 30 degrees C (17.46 mm day(-1)). In general, growth rates increased with the increment of a(w). No growth was observed at a(w) below 0.85. For all a(w) levels tested the highest growth rate was detected at 30 degrees C. At 15 degrees C growth only occurred at the higher a(w) levels evaluated (0.925 and 0.95) at a growth rate of 3.82 and 5.57 mm day(-1) respectively. The shortest lag phase (0.26 days) was found at 0.925 a(w) and 35 degrees C. At marginal conditions of a(w) and temperature the lag phases increased, being the highest registered at 20 degrees C and 0.89 a(w) (33.7 days). The pattern of effects of environmental factors on growth was similar among Argentinean A. carbonarius strains and those from several European countries, Israel and Australia.


Subject(s)
Aspergillus/growth & development , Aspergillus/metabolism , Ochratoxins/biosynthesis , Temperature , Vitis/microbiology , Water/metabolism , Argentina , Colony Count, Microbial , Food Contamination/analysis , Food Microbiology , Fruit/microbiology , Kinetics
SELECTION OF CITATIONS
SEARCH DETAIL