Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Biochem ; 568: 7-13, 2019 03 01.
Article in English | MEDLINE | ID: mdl-30582897

ABSTRACT

Spherical gold nanoparticles are the most commonly used marker in lateral flow assays. However, the widespread practice of using identical coloration for the test and control zones of test strips can lead to erroneous interpretations of the assay's results. We propose an immunochromatographic test strip with lines of different colors. For this purpose, gold nanoparticles of different shapes were used, namely blue nanoflowers in the test zone and red gold nanospheres in the control zone. A detailed synthesis procedure for nanoparticles and their conjugates is considered and design parameters for optimal results are described. For the first time, nanoparticles of different shapes have been combined in the test strip with indirect labeling of specific antibodies (via their interaction with labeled secondary antibodies). Using the T-2 toxin (T2T) as an example, an instrumental detection limit of 30 pg/ml and a working range 0.06-0.9 ng/mL were achieved in an analysis of water-organic corn extracts.


Subject(s)
Antibodies/analysis , Color , Gold/chemistry , Metal Nanoparticles/chemistry , Reagent Strips/chemistry , Humans , Particle Size , Surface Properties
2.
Talanta ; 175: 77-81, 2017 Dec 01.
Article in English | MEDLINE | ID: mdl-28842038

ABSTRACT

The scheme of immunochromatographic competitive analysis with "external" specific antibodies is offered for the first time. The test strip includes all the necessary components for analysis (membranes, protein antigen conjugates, colored nanoparticles), except specific free unconjugated antibodies that are transferred to the buffer used for sample dilution. Thus, the concentrations of the antibodies and markers can be chosen independently, and dilution of the sample with buffer (a routine procedure for any immunochromatographic test) ensures pre-incubation of the antibodies with the sample. Both factors increase the sensitivity of the test. The proposed scheme has been proven to be effective for the determination of deoxynivalenol and T-2 toxin; detection limits of 500pg/mL and 50pg/mL, respectively, were achieved. This is an order of magnitude lower than the limits of detection of traditional tests using the same reagents. The analysis was conducted in water-organic extracts (20% methanol); the duration of the analysis is 10min (it's the same time as for a traditional test). The proposed approach is universal, and it can be used to detect a variety of compounds.


Subject(s)
Antibodies, Immobilized/chemistry , Chromatography, Affinity/methods , Gold/chemistry , Metal Nanoparticles/chemistry , T-2 Toxin/analysis , Trichothecenes/analysis , Animals , Antibodies, Monoclonal/chemistry , Chromatography, Affinity/instrumentation , Equipment Design , Immunoglobulin G/chemistry , Limit of Detection , Mice
3.
Biotechnol Lett ; 39(5): 751-758, 2017 May.
Article in English | MEDLINE | ID: mdl-28150075

ABSTRACT

OBJECTIVE: To develop a high-sensitivity immunochromatographic test for fumonisin B1 in plant extracts. RESULTS: Unlike conventional immunochromatographic tests, this assay is performed in two stages: competitive reaction with free specific antibodies and identifying immune complexes by their interaction with the anti-species antibody-conjugated gold nanoparticles. The use of a new geometry for the test strip membranes and a novel reagent application method ensures the proper order of these stages without additional manipulations. The contact of the ready-to-use test strip with the liquid sample suffices in initiating all stages of the assay and obtaining test results. The developed test was used on corn extracts; its instrumental limit of fumonisin B1 detection was 0.6 ng ml-1 at 15 min of assay duration. CONCLUSIONS: The proposed approach is flexible and can be used for a wide range of low molecular compounds. The use of anti-species antibody-conjugated gold nanoparticles in immunochromatography significantly facilitates the development of test systems by eliminating the need to synthesize and characterize the conjugates with specific antibodies for each new compound to be detected.


Subject(s)
Antibodies, Immobilized/metabolism , Chromatography, Affinity/methods , Fumonisins/analysis , Fumonisins/metabolism , Antibodies, Immobilized/chemistry , Enzyme-Linked Immunosorbent Assay , Equipment Design , Gold/chemistry , Limit of Detection , Metal Nanoparticles/chemistry , Plant Extracts/chemistry , Zea mays/chemistry
4.
Mikrochim Acta ; 185(1): 29, 2017 12 06.
Article in English | MEDLINE | ID: mdl-29594553

ABSTRACT

A new kind of competitive immunochromatographic assay is presented. It is based on the use of a test strip loaded with (a) labeled specific antibodies, (b) a hapten-protein conjugate at the control zone, and (c) antibodies interacting with the specific antibodies in the analytical zone. In the case where a sample does not contain the target antigen (hapten), all labeled antibodies remain in the control zone because of the selected ratio of reactants. The analytical zone remains colorless because the labeled antibodies do not reach it. If an antigen is present in the sample, it interferes with the binding of the specific antibodies in the control zone and knocks them out. Some of these antibodies pass the control zone to form a colored line in the analytical zone. The intensity of the color is directly proportional to the amount of the target antigen in the sample. The assay has an attractive feature in that an appearance in coloration is more easily detected visually than a decoloration. Moreover, the onset of coloration is detectable at a lower concentration than a decoloration. The new detection scheme was applied to the determination of the mycotoxin deoxynivalenol. The visual limit of detection is 2 ng·mL-1 in corn extracts (35 ng per gram of sample). With the same reagents, this is lower by a factor of 60 than the established test strip. The assay takes only 15 min. This new kind of assay has wide potential applications for numerous low molecular weight analytes. Graphical abstract Competitive immunochromatography with direct analyte-signal dependence is proposed. It provides a 60-fold decrease of the detection limit for mycotoxin deoxynivalenol. The analyte-antibody-label complexes move along the immobilized antigen (control zone) and bind with anti-species antibodies (test zone).


Subject(s)
Immunoassay/methods , Limit of Detection , Trichothecenes/analysis , Costs and Cost Analysis , Immunoassay/economics
5.
Biosens Bioelectron ; 86: 575-579, 2016 Dec 15.
Article in English | MEDLINE | ID: mdl-27453985

ABSTRACT

Immunoreagents with good results in the competitive enzyme-linked immunosorbent assay are often unable to provide the required detection limit in the traditional competitive immunochromatographic assay. The solution may be either the production of new reagents or improving the test strip. In the latter case, the assay is often performed stepwise using additional liquid reagents, but this is a significant drawback for practical use. We introduce a test strip made as a dry chemical device that still provides the two-step immunochemical interactions - formation of a complex of specific antibodies with an antigen and its detection by a conjugate of antispecies antibodies with a nano-sized label. Analysis with this test strip is similar to that with ordinary test strips and requires no additional reagents and manipulation. The use of specific antibodies and marker as two separate components allows to improve the analytical parameters. The new test significantly lowers the limit of detection, making it possible to use antibodies previously ineffective in immunochromatography. The proposed approach was tested by determining zearalenone and aflatoxin B1 mycotoxins. The visual limit of detection for aflatoxin B1 decreased to 0.6ng/mL compared to 11ng/mL with an ordinary test strip. For zearalenone, a test strip was created with visual detection limit of 6ng/mL with reagents inefficient in the traditional test strip (which is not able to detect even 9µg/mL of zearalenone). Thus, the proposed approach allows obtaining 'dry', multi-stage, immunochromatographic test strips, providing a highly sensitive detection method.


Subject(s)
Aflatoxin B1/analysis , Chromatography, Affinity/instrumentation , Food Analysis/instrumentation , Food Analysis/methods , Reagent Strips/analysis , Zearalenone/analysis , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Chromatography, Affinity/methods , Equipment Design , Gold/chemistry , Humans , Limit of Detection , Metal Nanoparticles/chemistry , Zea mays/chemistry
7.
Toxins (Basel) ; 7(2): 238-54, 2015 Jan 27.
Article in English | MEDLINE | ID: mdl-25633750

ABSTRACT

Mycotoxins are low molecular weight fungal metabolites that pose a threat as toxic contaminants of food products, thereby necessitating their effective monitoring and control. Microplate ELISA can be used for this purpose, but this method is characteristically time consuming, with a duration extending to several hours. This report proposes a variant of the ELISA method for the detection and quantification of three mycotoxins, ochratoxin A, aflatoxin B1 and zearalenone, in the kinetic regime. The main requirement for the proposed kinetic protocol was to provide a rapid method that combined sensitivity and accuracy. The use of biotin with an extended spacer together with a streptavidin-polyperoxidase conjugate provided high signal levels, despite these interactions occurring under non-equilibrium conditions. Duration of the individual mycotoxin assays was 20 min, whereas the analysis of all three mycotoxins in parallel reached a maximum duration of 25 min. Recovery of at least 95% mycotoxins in water-organic extracts was shown. The developed assays were successfully validated using poultry processing products and corn samples spiked with known quantities of mycotoxins. The detection limits for aflatoxin B1, ochratoxin A and zearalenone in these substances were 0.24, 1.2 and 3 ng/g, respectively.


Subject(s)
Aflatoxin B1/analysis , Enzyme-Linked Immunosorbent Assay/methods , Food Contamination/analysis , Ochratoxins/analysis , Zearalenone/analysis , Antibodies, Immobilized/chemistry , Limit of Detection , Time Factors
8.
Sensors (Basel) ; 14(11): 21843-57, 2014 Nov 18.
Article in English | MEDLINE | ID: mdl-25412219

ABSTRACT

The main limitations of microplate-based enzyme immunoassays are the prolonged incubations necessary to facilitate heterogeneous interactions, the complex matrix and poorly soluble antigens, and the significant sample dilutions often required because of the presence of organic extractants. This study presents the use of antibody immobilization on the surface of magnetic particles to overcome these limitations in the detection of the mycotoxin, aflatoxin B1. Features of the proposed system are a high degree of nanoparticle dispersion and methodologically simple immobilization of the antibodies by adsorption. Reactions between the immobilized antibodies with native and labeled antigens are conducted in solution, thereby reducing the interaction period to 5 min without impairing the analytical outcome. Adsorption of immunoglobulins on the surface of magnetic nanoparticles increases their stability in aqueous-organic media, thus minimizing the degree of sample dilution required. Testing barley and maize extracts demonstrated a limit of aflatoxin B1 detection equal to 20 pg/mL and total assay duration of 20 min. Using this method, only the 3-fold dilution of the initial methanol/water (60/40) extraction mixture in the microplate wells is necessary. The proposed pseudo-homogeneous approach could be applied toward immunodetection of a wide range of compounds.


Subject(s)
Aflatoxin B1/analysis , Enzyme-Linked Immunosorbent Assay/instrumentation , Food Analysis/instrumentation , Food Contamination/analysis , Immunomagnetic Separation/instrumentation , Magnetite Nanoparticles/chemistry , Equipment Design , Equipment Failure Analysis , Magnetite Nanoparticles/ultrastructure , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL