Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Orthop J Sports Med ; 11(4): 23259671231162361, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37056453

ABSTRACT

Background: Failure of a subscapularis repair construct after anatomic total shoulder arthroplasty can result in difficulty with internal rotation and an increased likelihood of dislocation. Although suture tape has been demonstrated to be an efficacious augment for tendonous repairs elsewhere in the body, it has not been investigated as a method for augmenting subscapularis peel repairs. Purpose: To determine the biomechanical efficacy of suture tape augmentation for the repair of a subscapularis peel. Study Design: Controlled laboratory study. Methods: Twelve human cadaveric shoulders underwent a subscapularis peel. Specimens were randomly split into 2 groups: 6 specimens underwent repair using a transosseous bone tunnel technique with 3 high-strength sutures placed with a Mason-Allen configuration (control group), and 6 specimens underwent the control repair using augmentation with 2 suture tapes placed in an inverted mattress fashion and secured to the proximal humerus using a suture anchor (augmentation group). Shoulders underwent biomechanical testing to compare repair displacement with cyclic loading, load at ultimate failure, and construct stiffness. Results: There were no significant between-group differences in displacement after cyclic loading at the superior (P = .87), middle (P = .47), or inferior (P = .77) portions of the subscapularis tendon. Load to failure was significantly greater in the augmentation group (585.1 ± 97.4 N) than in the control group (358.5 ± 81.8 N) (P = .001). Stiffness was also greater in the augmentation group (71.8 ± 13.7 N/mm) when compared with the control group (48.7 ± 5.7 N/mm) (P = .003). Conclusion: Subscapularis peel repair with augmentation via 2 inverted mattress suture tapes secured with an anchor in the proximal humerus conferred significantly greater load at ultimate failure and construct stiffness when compared with a traditional repair using 3 Mason-Allen sutures. There was no difference in repair displacement with cyclic loading between the repair groups. Clinical Relevance: Suture tape augmentation of subscapularis peel repairs after shoulder arthroplasty provides an effective segment to the strength of the repair.

2.
Arthrosc Sports Med Rehabil ; 5(2): e415-e421, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37101876

ABSTRACT

Purpose: To prospectively determine opioid consumption in patients undergoing anterior cruciate ligament (ACL) repair and reconstruction and to develop evidence-based prescription guidelines following ACL surgery. Methods: This multicenter prospective study enrolled patients undergoing ACL reconstruction and repair. Subject demographics and opioid prescriptions were recorded at enrollment. All patients were given education on opiate use and followed the same perioperative, multimodal analgesic regimen. Following surgery, patients were given postoperative "pain journals" to document visual analog scale pain scores and daily opioid consumption for the first 7 postoperative days and on postoperative visit at 14 days. Results: In total, 50 patients were included in this analysis between the ages of 14 and 65 years. Patients were prescribed a median of 15 oxycodone 5-mg pills and consumed a median of 2 pill postoperatively (range 0-19 pills). 38% of patients consumed 0 opioid pills, 74% of patients consumed ≤5 opioid pills, and 96% of patients consumed ≤15 opioid pills. Patients reported a mean daily visual analog scale value of 2.8 of 10; mean satisfaction with pain management was high at 4.1/5 on a Likert satisfaction score. Overall, patients consumed a mean 34% of their opioid prescriptions, leaving 436 opioid pills not consumed. Conclusions: This study suggests that current expert panels may be recommending an excessive volume of opioids. Based on our findings, we recommend that patients be prescribed no more than 15 Oxycodone 5-mg tablets following ACL surgery. Despite this lower volume prescription, mean pain scores remained below 3 of 10, patient satisfaction with pain control remained high, and 66% of opiate medication prescribed was not used. Level of Evidence: II, prospective prognostic cohort investigation.

3.
J Shoulder Elbow Surg ; 32(2): 326-332, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36108881

ABSTRACT

BACKGROUND: Subscapularis failure is a troublesome complication following anatomic total shoulder arthroplasty (aTSA). Commonly discarded during aTSA, the long head of the biceps tendon (LHBT) may offer an efficient and cheap autograft for the augmentation of the subscapularis repair during aTSA. The purpose of this study was to biomechanically compare a standard subscapularis peel repair to 2 methods of subscapularis peel repair augmented with LHBT. METHODS: 18 human cadaveric shoulders (61 ± 9 years of age) were used in this study. Shoulders were randomly assigned to biomechanically compare subscapularis peel repair with (1) traditional single-row repair, (2) single row with horizontal LHBT augmentation, or (3) single row with V-shaped LHBT augmentation. Shoulders underwent biomechanical testing on a servohydraulic testing system to compare cyclic displacement, load to failure, and stiffness. RESULTS: There were no significant differences in the cyclic displacement between the 3 techniques in the superior, middle, or inferior portion of the subscapularis repair (P > .05). The horizontal (436.7 ± 113.3 N; P = .011) and V-shape (563.3 ± 101.0 N; P < .001) repair demonstrated significantly greater load to failure compared with traditional repair (344.4 ± 82.4 N). The V-shape repair had significantly greater load to failure compared to the horizontal repair (P < .001). The horizontal (61.6 ± 8.4 N/mm; P < .001) and the V-shape (62.8 ± 6.1; P < .001) repairs demonstrated significantly greater stiffness compared to the traditional repair (47.6 ± 6.2 N). There was no significant difference in the stiffness of the horizontal and V-shape repairs (P = .770). CONCLUSIONS: Subscapularis peel repair augmentation with LHBT autograft following aTSA confers greater time zero load to failure and stiffness when compared to a standard subscapularis peel repair.


Subject(s)
Arthroplasty, Replacement, Shoulder , Shoulder Joint , Humans , Arthroplasty, Replacement, Shoulder/methods , Biomechanical Phenomena , Cadaver , Rotator Cuff/surgery , Shoulder Joint/surgery , Suture Techniques , Tendons/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...