Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 80
Filter
1.
bioRxiv ; 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-38293086

ABSTRACT

The Glucose transporter 1 (GLUT1) is one of the most abundant proteins within the erythrocyte membrane and is required for glucose and dehydroascorbic acid (Vitamin C precursor) transport. It is widely recognized as a key protein for red cell structure, function, and metabolism. Previous reports highlighted the importance of GLUT1 activity within these uniquely glycolysis-dependent cells, in particular for increasing antioxidant capacity needed to avoid irreversible damage from oxidative stress in humans. However, studies of glucose transporter roles in erythroid cells are complicated by species-specific differences between humans and mice. Here, using CRISPR-mediated gene editing of immortalized erythroblasts and adult CD34+ hematopoietic progenitor cells, we generate committed human erythroid cells completely deficient in expression of GLUT1. We show that absence of GLUT1 does not impede human erythroblast proliferation, differentiation, or enucleation. This work demonstrates for the first-time generation of enucleated human reticulocytes lacking GLUT1. The GLUT1-deficient reticulocytes possess no tangible alterations to membrane composition or deformability in reticulocytes. Metabolomic analyses of GLUT1-deficient reticulocytes reveal hallmarks of reduced glucose import, downregulated metabolic processes and upregulated AMPK-signalling, alongside alterations in antioxidant metabolism, resulting in increased osmotic fragility and metabolic shifts indicative of higher oxidant stress. Despite detectable metabolic changes in GLUT1 deficient reticulocytes, the absence of developmental phenotype, detectable proteomic compensation or impaired deformability comprehensively alters our understanding of the role of GLUT1 in red blood cell structure, function and metabolism. It also provides cell biological evidence supporting clinical consensus that reduced GLUT1 expression does not cause anaemia in GLUT1 deficiency syndrome.

2.
Arch Orthop Trauma Surg ; 144(2): 755-762, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38129717

ABSTRACT

PURPOSE: To compare primary arthrodesis (PA) versus open reduction and internal fixation (ORIF) in displaced intra-articular calcaneal fractures (DIACFs), based on clinical outcome and 2D and 3D geometrical analyses obtained from weight-bearing (WB) cone-beam CT images. MATERIALS AND METHODS: In this prospective study, 40 patients with surgically treated calcaneal fractures were included, consisting of 20 PA and 20 ORIF patients. Weight-bearing cone-beam CT-images of the left and right hindfoot and forefoot were acquired on a Planmed Verity cone-beam CT-scanner after a minimum of 1-year follow-up. Automated 2D and 3D geometric analyses, i.e., (minimal and average) talo-navicular joint space, calcaneal pitch (CP), and Meary's angle (MA), were obtained for injured and healthy feet. Clinical outcomes were measured using the EQ5D and FFI questionnaires. RESULTS: Overall, there were no differences in baseline patient characteristics apart from age (p < 0.005). The calcaneal pitch in 2D after treatment by ORIF (13.8° ± 5.6) was closer to the uninjured side (18.1° ± 5.5) compared to PA (10.9° ± 4.5) (p < 0.001). Meary's angle in 2D was closer to the uninjured side (8.7° ± 6.3) after surgery in the PA cohort (7.0° ± 5.8) compared to the ORIF cohort (15.5° ± 5.9) (p = 0.046). In 3D measurements, CP was significantly decreased for both cohorts after surgery (- 4.09° ± 6.2) (p = 0.001). MA was not significantly affected overall or between cohorts in 3D. Clinical outcomes were not significantly different between the ORIF and PA cohorts. None of the radiographic measurements in 2D or 3D correlated with any of the clinical outcomes studied. CONCLUSION: Three-dimensional WB CT imaging enables functional 2D and 3D analyses under natural load in patients with complex calcaneal fractures. Based on clinical outcome, both PA and ORIF appear viable treatment options. Clinical correlation with geometrical outcomes remains to be established.


Subject(s)
Ankle Injuries , Calcaneus , Foot Injuries , Fractures, Bone , Intra-Articular Fractures , Humans , Fracture Fixation, Internal/methods , Prospective Studies , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Calcaneus/diagnostic imaging , Calcaneus/surgery , Arthrodesis , Tomography, X-Ray Computed/methods , Weight-Bearing , Treatment Outcome , Intra-Articular Fractures/diagnostic imaging , Intra-Articular Fractures/surgery
3.
Sci Rep ; 13(1): 21769, 2023 12 08.
Article in English | MEDLINE | ID: mdl-38066256

ABSTRACT

CT imaging under external valgus and varus loading conditions and consecutive image analysis can be used to detect tibial implant loosening after total knee arthroplasty. However, the applied load causes the tibia to deform, which could result in an overestimation of implant displacement. This research evaluates the extent of tibia deformation and its effect on measuring implant displacement. Ten cadaver specimen with TKA were CT-scanned under valgus/varus loading (20 Nm), first implanted without bone cement fixation (mimicking a loose implant) and subsequently with bone cement fixation (mimicking a fixed implant). By means of image analysis, three relative displacements were assessed: (1) between the proximal and distal tibia (measure of deformation), (2) between the implant and the whole tibia (including potential deformation effect) and (3) between the implant and the proximal tibia (reduced deformation effect). Relative displacements were quantified in terms of translations along, and rotations about the axes of a local coordinate system. As a measure of deformation, the proximal tibia moved relative to the distal tibia by, on average 1.27 mm (± 0.50 mm) and 0.64° (± 0.25°). Deformation caused an overestimation of implant displacement in the cemented implant. The implant displaced with respect to the whole tibia by 0.45 mm (± 0.22 mm) and 0.79° (± 0.38°). Relative to the proximal tibia, the implant moved by 0.23 mm (± 0.10 mm) and 0.62° (± 0.34°). The differentiation between loose and fixed implants improved when tibia deformation was compensated for by using the proximal tibia rather than the whole tibia.


Subject(s)
Arthroplasty, Replacement, Knee , Tibia , Tibia/diagnostic imaging , Tibia/surgery , Bone Cements , Arthroplasty, Replacement, Knee/methods , Prostheses and Implants , Image Processing, Computer-Assisted , Knee Joint/diagnostic imaging , Knee Joint/surgery
4.
Clin Biomech (Bristol, Avon) ; 110: 106126, 2023 12.
Article in English | MEDLINE | ID: mdl-37883885

ABSTRACT

BACKGROUND: This study assessed the use of dual-energy computed tomography (CT) to evaluate sub-calcaneal plantar fat pad changes in people with diabetic neuropathy. METHODS: Dual-energy CT scans of people with diabetic neuropathy and non-diabetic controls were retrospectively included. Average CT values (in Hounsfield Units) and thickness (in centimeters) of the sub-calcaneal plantar fat pad were measured in mono-energetic images at two energy levels (40 keV and 70 keV). The CT values measured in patients with diabetic neuropathy were correlated to barefoot plantar pressure measurements performed during walking in a clinical setting. FINDINGS: Forty-five dual-energy CT scans of people with diabetic neuropathy and eleven DECT scans of non-diabetic controls were included. Mean sub-calcaneal plantar fat pad thickness did not significantly differ between groups (diabetes group 1.20 ± 0.34 cm vs. control group 1.21 ± 0.28 cm, P = 0.585). CT values at both 40 keV (-34.7 ± 48.7 HU vs. -76.0 ± 42.8 HU, P = 0.013) and 70 keV (-11.2 ± 30.8 HU vs. -36.3 ± 27.2 HU, P = 0.017) were significantly higher in the diabetes group compared to controls, thus contained less fatty tissue. This elevation was most apparent in patients with Type 1 diabetes. CT values positively correlated with the mean peak plantar pressure. INTERPRETATION: Dual-energy CT was able to detect changes in the plantar fat pad of people with diabetic neuropathy.


Subject(s)
Diabetes Mellitus, Type 1 , Diabetic Foot , Diabetic Neuropathies , Humans , Diabetic Foot/diagnostic imaging , Diabetic Neuropathies/diagnostic imaging , Retrospective Studies , Tomography, X-Ray Computed/methods , Adipose Tissue/diagnostic imaging
5.
Contemp Clin Trials Commun ; 33: 101107, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36950303

ABSTRACT

Foot ulcers are a frequent and costly problem in people with diabetes mellitus and can lead to amputations. Prevention of these ulcers is therefore of paramount importance. Claw/hammer toe deformities are commonly seen in people with diabetes. These deformities increase the risk of ulcer development specifically at the (tip of) the toe. Percutaneous needle tenotomy of the tendon of the m. flexor digitorum longus (tendon tenotomy) can be used to reduce the severity of claw/hammer toe deformity with the goal to prevent ulcer recurrence. The main objective of this randomized controlled trial is to assess the efficacy of flexor tenotomy to prevent recurrence of toe ulcers in people with diabetes and a history of toe (pre-)ulcers. Additionally, we aim to assess interphalangeal joints (IPJ) and metatarsophalangeal joint (MTPJ) angles in a weight-bearing and non-weight-bearing position, barefoot plantar pressure during walking, cost-effectiveness and quality of life before and after the intervention and compare intervention and control study groups. Sixty-six subjects with diabetes and claw/hammer toe deformity and a recent history of (pre-)ulceration on the tip of the toe will be included and randomized between flexor tenotomy of claw/hammer toes (intervention) versus standard of care including orthosis and shoe offloading (controls) in a mono-center randomized controlled trial. Clinicaltrialsgov registration: NCT05228340.

6.
Eur Spine J ; 32(5): 1777-1786, 2023 05.
Article in English | MEDLINE | ID: mdl-36943485

ABSTRACT

PURPOSE: Adolescent idiopoathic scoliosis (AIS) is a progressive spinal deformity, most often observed in female patients of pubescent age. The deformity's severity, its progression through time, its treatment and subsequent follow-up are assessed with routine radiological evaluation of the patient's full spine. This study aimed to determine the cumulative radiation exposure in average patients with AIS treated by brace or surgery throughout their treatment. METHODS: The average number of imaging procedures and corresponding radiation doses were retrospectively obtained from the medical charts of AIS patients treated conservatively and/or surgically at our institution. The median radiation exposure of all imaging modalities was stated in effective dose (mSv). The estimated cumulative effective radiation dose of the each treatment group was determined by multiplication of the average number of imaging conducted, and the median effective radiation dose per imaging modality. RESULTS: In total, 73 AIS patients were included (28 brace, 45 surgically). Patients treated with a brace were subjected to an average of 9.03 full spine radiographs, resulting in an estimated effective cumulative dose of 0.505 mSv over a median treatment period of 3.23 years. Patients treated surgically received an average of 14.29 full spine radiographs over a median treatment period of 2.76 years. The estimated effective cumulative dose amounted from 0.951 to 1.841 mSv, depending on the surgical technique. CONCLUSION: The cumulative effective radiation doses rendered to AIS patients as part of their treatment and follow-up were relatively low. However, every exposure to ionising radiation for medical imaging purposes should be minimised.


Subject(s)
Kyphosis , Radiation Exposure , Scoliosis , Humans , Adolescent , Female , Scoliosis/surgery , Retrospective Studies , Radiography , Braces
7.
Eur Radiol ; 33(8): 5645-5652, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36820925

ABSTRACT

OBJECTIVES: The purpose of this study is to evaluate the value of dual-energy CT (DECT) with virtual non-calcium (VNCa) in quantitatively assessing the presence of bone marrow edema (BME) in patients with diabetic foot ulcers and suspected osteomyelitis. METHODS: Patients with a diabetic foot ulcer and suspected osteomyelitis that underwent DECT (80 kVp/Sn150 kVp) with VNCa were retrospectively included. Two observers independently measured CT values of the bone adjacent to the ulcer and a reference bone not related to the ulcer. The patients were divided into two clinical groups, osteomyelitis or no-osteomyelitis, based on the final diagnosis by the treating physicians. RESULTS: A total of 56 foot ulcers were identified of which 23 were included in the osteomyelitis group. The mean CT value at the ulcer location was significantly higher in the osteomyelitis group (- 17.23 ± 34.96 HU) compared to the no-osteomyelitis group (- 69.34 ± 49.40 HU; p < 0.001). Within the osteomyelitis group, the difference between affected bone and reference bone was statistically significant (p < 0.001), which was not the case in the group without osteomyelitis (p = 0.052). The observer agreement was good for affected bone measurements (ICC = 0.858) and moderate for reference bone measurements (ICC = 0.675). With a cut-off value of - 40.1 HU, sensitivity was 87.0%, specificity was 72.7%, PPV was 69.0%, and NPV was 88.9%. CONCLUSION: DECT with VNCa has a potential value for quantitatively assessing the presence of BME in patients with diabetic foot ulcers and suspected osteomyelitis. KEY POINTS: • Dual-energy CT (DECT) with virtual non-calcium (VNCa) is promising for detecting bone marrow edema in the case of diabetic foot ulcers with suspected osteomyelitis. • DECT with VNCa has the potential to become a more practical alternative to MRI in assessing the presence of bone marrow edema in suspected osteomyelitis when radiographs are not sufficient to form a diagnosis.


Subject(s)
Bone Marrow Diseases , Diabetes Mellitus , Diabetic Foot , Osteomyelitis , Humans , Bone Marrow , Diabetic Foot/complications , Diabetic Foot/diagnostic imaging , Retrospective Studies , Sensitivity and Specificity , Tomography, X-Ray Computed , Bone Marrow Diseases/diagnosis , Osteomyelitis/complications , Osteomyelitis/diagnostic imaging , Calcium , Edema/complications , Edema/diagnostic imaging , Magnetic Resonance Imaging
8.
Sci Rep ; 13(1): 3159, 2023 02 23.
Article in English | MEDLINE | ID: mdl-36823242

ABSTRACT

Distal radio-ulnar joint (DRUJ) motion analysis using dynamic CT is gaining popularity. Following scanning and segmentation, 3D bone models are registered to (4D-)CT target frames. Imaging errors like low signal-to-noise ratio (SNR), limited Z-coverage and motion artefacts influence registration, causing misinterpretation of joint motion. This necessitates quantification of the methodological error. A cadaver arm and dynamic phantom were subjected to multiple 4D-CT scans, while varying tube charge-time product and phantom angular velocity, to evaluate the effects of SNR and motion artefacts on registration accuracy and precision. 4D-CT Z-coverage is limited by the scanner. To quantify the effects of different Z-coverages on registration accuracy and precision, 4D-CT was simulated by acquiring multiple spiral 3D-CT scans of the cadaver arm. Z-coverage was varied by clipping the 3D bone models prior to registration. The radius position relative to the ulna was obtained from the segmentation image. Apparent relative displacement seen in the target images is caused by registration errors. Worst-case translations were 0.45, 0.08 and 1.1 mm for SNR-, Z-coverage- and motion-related errors respectively. Worst-case rotations were 0.41, 0.13 and 6.0 degrees. This study showed that quantification of the methodological error enables composition of accurate and precise DRUJ motion scanning protocols.


Subject(s)
Four-Dimensional Computed Tomography , Wrist Joint , Humans , Biomechanical Phenomena , Four-Dimensional Computed Tomography/methods , Motion , Phantoms, Imaging , Cadaver
9.
Foot Ankle Surg ; 29(7): 538-543, 2023 Oct.
Article in English | MEDLINE | ID: mdl-36641368

ABSTRACT

BACKGROUND: The aim of this study was to present and evaluate methods of measuring toe joint angels using joint-surface based and inertial axes approaches. METHODS: Nine scans of one frozen human cadaveric foot were obtained using weight-bearing CT. Two observers independently segmented bones in the forefoot and measured metatarsalphalangeal joint (MTPJ) angles, proximal and distal interphalangeal joint (PIPJ and DIPJ) angles and interphalangeal angles of the hallux (IPJ) using 1) inertial axes, representing the long anatomical axes, of the bones and 2) axes determined using centroids of articular joint surfaces. RESULTS: The standard deviations (SD) of the IPJ/PIPJ and DIPJ angles were lower using joint-surface based axes (between 1.5˚ and 4.1˚) than when the inertial axes method was used (between 3.3˚ and 16.4˚), for MTPJ the SD's were similar for both methods (between 0.5˚ and 2.6˚). For the IPJ/PIPJ and DIPJ angles, the width of the 95% CI and the range were also lower using the joint-surface axes method (95% CI: 2.0˚-4.1˚ vs 3.2˚-16.3˚; range: 3.1˚-7.4˚ vs 3.8˚-35.8˚). Intra-class correlation coefficients (ICC) representing inter- and intra-rater reliability were good to excellent regarding the MTPJ and IPJ/PIPJ angles in both techniques (between 0.85 and 0.99). For DIPJ angles, ICC's were good for the inertial axes method (0.78 and 0.79) and moderate for the joint-surface axes method (0.60 and 0.70). CONCLUSION: The joint-surface axes method enables reliable and reproducible measurements of MTPJ, IPJ/PIPJ and DIPJ angles. For PIPJ and DIPJ angles this method is preferable over the use of inertial axes.


Subject(s)
Metatarsophalangeal Joint , Humans , Metatarsophalangeal Joint/diagnostic imaging , Metatarsophalangeal Joint/surgery , Reproducibility of Results , Toe Joint/diagnostic imaging , Tomography, X-Ray Computed , Weight-Bearing
10.
Skeletal Radiol ; 52(7): 1313-1320, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36585514

ABSTRACT

OBJECTIVE: The aims of this study were to visualize and quantify relative bone positions in the feet of individuals with cerebral palsy (CP) with a foot deformity and compare bone positions with those of typically developed (TD) controls. MATERIALS AND METHODS: Weight-bearing CT images of 14 individuals with CP scheduled for tendon transfer and/or bony surgery and of 20 TD controls were acquired on a Planmed Verity WBCT scanner. Centroids of the navicular and calcaneus with respect to the talus were used to quantify foot deformities. All taluses were aligned and the size and dimensions of the individuals' talus were scaled to correct for differences in bone sizes. In order to visualize and quantify variations in relative bone positions, 95% CI ellipsoids and standard deviations in its principle X-, Y-, and Z-directions were determined. RESULTS: In individuals with CP (age 11-17), a large variation in centroid positions was observed compared to data of TD controls. Radiuses of the ellipsoids, representing the standard deviations of the 95% CI in the principle X-, Y-, and Z-directions, were larger in individuals with CP compared to TD controls for both the calcaneus (3.16 vs 1.86 mm, 4.26 vs 2.60 mm, 9.19 vs 3.60 mm) and navicular (4.63 vs 1.55 mm, 5.18 vs 2.10 mm, 16.07 vs 4.16 mm). CONCLUSION: By determining centroids of the calcaneus and navicular with respect to the talus on WBCT images, normal and abnormal relative bone positions can be visualized and quantified in individuals with CP with various foot deformities.


Subject(s)
Calcaneus , Cerebral Palsy , Foot Deformities , Talus , Humans , Child , Adolescent , Cerebral Palsy/complications , Cerebral Palsy/diagnostic imaging , Cerebral Palsy/surgery , Calcaneus/diagnostic imaging , Foot Deformities/diagnostic imaging , Weight-Bearing , Tomography, X-Ray Computed
12.
J Laryngol Otol ; 135(5): 410-414, 2021 May.
Article in English | MEDLINE | ID: mdl-33883045

ABSTRACT

OBJECTIVE: This study aimed to compare the necessary scutum defect for transmeatal visualisation of middle-ear landmarks between an endoscopic and microscopic approach. METHOD: Human cadaveric heads were used. In group 1, middle-ear landmarks were visualised by endoscope (group 1 endoscopic approach) and subsequently by microscope (group 1 microscopic approach following endoscopy). In group 2, landmarks were visualised solely microscopically (group 2 microscopic approach). The amount of resected bone was evaluated via computed tomography scans. RESULTS: In the group 1 endoscopic approach, a median of 6.84 mm3 bone was resected. No statistically significant difference (Mann-Whitney U test, p = 0.163, U = 49.000) was found between the group 1 microscopic approach following endoscopy (median 17.84 mm3) and the group 2 microscopic approach (median 20.08 mm3), so these were combined. The difference between the group 1 endoscopic approach and the group 1 microscopic approach following endoscopy plus group 2 microscopic approach (median 18.16 mm3) was statistically significant (Mann-Whitney U test, p < 0.001, U = 18.000). CONCLUSION: This study showed that endoscopic transmeatal visualisation of middle-ear landmarks preserves more of the bony scutum than a microscopic transmeatal approach.


Subject(s)
Ear, Middle/diagnostic imaging , Ear, Middle/surgery , Endoscopy , Microsurgery , Otologic Surgical Procedures , Cadaver , Humans , Imaging, Three-Dimensional , Tomography, X-Ray Computed
13.
Eur J Radiol ; 138: 109674, 2021 May.
Article in English | MEDLINE | ID: mdl-33798932

ABSTRACT

OBJECTIVES: We hypothesize that three-dimensional (3D) geometric analyses in weight bearing CT-images of the foot and ankle are more reproducible compared to two-dimensional (2D) analyses. Therefore, we compared 2D and 3D analyses on bones of weight-bearing and non weight-bearing cone-beam CT images of healthy volunteers. METHODS: Twenty healthy volunteers (10 male, 10 female, mean age 37.5 years) underwent weight-bearing and non weight-bearing cone-beam CT imaging of both feet. Clinically relevant height and angle measurements were performed in 2D and 3D (for example: cuboid height, calcaneal pitch, talo-calcaneal angle, Meary's angle, intermetatarsal angle). Three-dimensional measurements were obtained using automated software. Intra-observer and inter-observer agreement were evaluated for all 2D measurements. RESULTS: Overall intraclass correlation coefficients (ICC's) were higher than 0.750 for most 2D measurements, ranging from 0.352 to 0.995. Calcaneal pitch, angle between the first metatarsal (MT1) and proximal phalange 1, between the fifth metatarsal (MT5) and the calcaneus and heights of the sesamoid bones, navicular, cuboid and talus decreased during weight-bearing in both 2D and 3D results (p < 0.01). Meary's angle was not statistically different in 2D (p = 0.627) and 3D (p = 0.765). Higher coefficients of variation in 2D geometric analysis parameters (0.27 versus 0.16) indicate that 3D analyses are more precise compared to 2D (p < 0.01). Results of left and right feet are comparable for 2D and 3D analyses. CONCLUSION: Although 2D and 3D geometrical analyses are fundamentally different, automated 3D analyses are more reproducible and precise compared to 2D analyses. In addition, 3D evaluation better demonstrates differences in bone configurations between weight-bearing and non weight-bearing conditions, which may be of value to demonstrate pathology.


Subject(s)
Ankle , Cone-Beam Computed Tomography , Adult , Ankle Joint/diagnostic imaging , Female , Humans , Male , Reference Standards , Weight-Bearing
14.
Int J Comput Assist Radiol Surg ; 16(3): 505-513, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33475897

ABSTRACT

PURPOSE: In corrective osteotomy of the distal radius, patient-specific 3D printed surgical guides or optical navigation systems are often used to navigate the surgical saw. The purpose of this cadaver study is to present and evaluate a novel cast-based guiding system to transfer the virtually planned corrective osteotomy of the distal radius. METHODS: We developed a cast-based guiding system composed of a cast featuring two drilling slots as well as an external cutting guide that was used to orient the surgical saw for osteotomy in the preoperatively planned position. The device was tested on five cadaver specimens with different body fat percentages. A repositioning experiment was performed to assess the precision of replacing an arm in the cast. Accuracy and precision of drilling and cutting using the proposed cast-based guiding system were evaluated using the same five cadaver arms. CT imaging was used to quantify the positioning errors in 3D. RESULTS: For normal-weight cadavers, the resulting total translation and rotation repositioning errors were ± 2 mm and ± 2°. Across the five performed surgeries, the median accuracy and Inter Quartile Ranges (IQR) of pre-operatively planned drilling trajectories were 4.3° (IQR = 2.4°) and 3.1 mm (IQR = 4.9 mm). Median rotational and translational errors in transferring the pre-operatively planned osteotomy plane were and 3.9° (IQR = 4.5°) and 2.6 mm (IQR = 4.2 mm), respectively. CONCLUSION: For normal weight arm specimens, navigation of corrective osteotomy via a cast-based guide resulted in transfer errors comparable to those using invasive surgical guides. The promising positioning capabilities justify further investigating whether the method could ultimately be used in a clinical setting, which could especially be of interest when used with less invasive osteosynthesis material.


Subject(s)
Carpal Bones/diagnostic imaging , Osteotomy/methods , Plastic Surgery Procedures/methods , Printing, Three-Dimensional , Surgery, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Cadaver , Computer-Aided Design , Elasticity , Humans , Radius , Reproducibility of Results , Rotation
15.
Eur J Radiol ; 132: 109159, 2020 Nov.
Article in English | MEDLINE | ID: mdl-33091864

ABSTRACT

PURPOSE: The aim of this study was to determine whether virtual monochromatic dual-energy CT imaging improves the evaluation of suspected non-union of the appendicular skeleton treated with titanium or stainless steel intramedullary nails and plates. METHOD: Forty-one patients with a clinical suspected non-union with hardware in place were included and scanned on a dual-source CT-scanner using 100/Sn150kVp. Images including titanium hardware were extracted at 130 keV. Images including stainless steel hardware were extracted at 150 keV. Monochromatic 70 keV images served as reference. Non-union confirmed during revision surgery was used as gold standard. A musculoskeletal radiologist and orthopedic trauma surgeon evaluated images on image quality, degree and location of consolidation, non-union type and diagnostic confidence. RESULTS: Likert scores with respect to image quality improved from 0.88 to 1.83 (p < 0.001) in high (130 and 150) keV images. High keV images reduced the number of false negative non-unions based on consolidation grade with 5% (p = 0.283). Agreement between observers regarding location of consolidation and non-union type did not improve in 130 and 150 keV images. Diagnostic confidence improved from 1.43 to 2.37 in high keV images compared to 70 keV images (p < 0.001). Overall diagnostic confidence was higher in intramedullary nails than plates (p < 0.05). CONCLUSIONS: Use of virtual monochromatic 130 and 150 keV dual-energy CT compared to 70 keV images improves the evaluation of suspected non-union of the appendicular skeleton treated with titanium or stainless steel intramedullary nails and plates.


Subject(s)
Radiographic Image Interpretation, Computer-Assisted , Radiography, Dual-Energy Scanned Projection , Humans , Titanium , Tomography, X-Ray Computed
16.
Surg Radiol Anat ; 42(8): 887-892, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32112283

ABSTRACT

PURPOSE: The aim of this study is to describe the number and location of the nutrient foramina in human scapulae which can minimize blood loss during surgery. METHODS: 30 cadaveric scapulae were macerated to denude the skeletal tissue. The nutrient foramina of 0.51 mm and larger were identified and labeled by adhering glass beads. CT scans of these scapulae were segmented resulting in a surface model of each scapula and the location of the labeled nutrient foramina. All scapulae were scaled to the same size projecting the nutrient foramina onto one representative scapular model. RESULTS: Average number of nutrient foramina per scapula was 5.3 (0-10). The most common location was in the supraspinous fossa (29.7%). On the costal surface of the scapula, most nutrient foramina were found directly inferior to the suprascapular notch. On the posterior surface, the nutrient foramina were identified under the spine of the scapula in a somewhat similar fashion as those on the costal surface. Nutrient foramina were least present in the peri-glenoid area. CONCLUSION: Ninety percent of scapulae have more than one nutrient foramen. They are located in specific areas, on both the posterior and costal surface.


Subject(s)
Haversian System/anatomy & histology , Scapula/blood supply , Adult , Aged , Aged, 80 and over , Blood Loss, Surgical/prevention & control , Cadaver , Dissection , Female , Fiducial Markers , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Scapula/diagnostic imaging , Scapula/surgery , Tomography, X-Ray Computed
17.
Surg Radiol Anat ; 42(8): 893, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32200424

ABSTRACT

Correction to: Surgical and Radiologic Anatomy.

18.
Clin Radiol ; 75(6): 448-456, 2020 06.
Article in English | MEDLINE | ID: mdl-32070481

ABSTRACT

AIM: To investigate possible differences between surgeons and radiologists in selecting optimal photon energy settings from a set of virtual monochromatic dual-energy computed tomography (CT) images for the assessment of bone union in patients with a suspected non-union of the appendicular skeleton. MATERIALS AND METHODS: Fifty patients suspected of having bone non-union after operative fracture treatment with a variety of fixation implants were included. Patients were scanned on a dual-source CT machine using 150/100-kVp. Monochromatic images were extracted at 70, 90, 110, 130, 150, and 190 keV. Images were reviewed by 159 orthopaedic trauma surgeons and 12 musculoskeletal radiologists in order to select the best and worst energy setting to assess bone union. Furthermore, a confidence score (1-4) was given in selecting the best and worst setting to assess bone union. RESULTS: Monochromatic 190 keV images were selected most frequently as the optimal energy in titanium (34.8%), stainless steel (40%), and combined implants of stainless steel and titanium (40.5%). Confidence scores and average optimal energies were higher and average worst energies were lower for radiologists compared to surgeons in all hardware (p<0.05). Differences in optimal energy were not statistically significant for different alloys or type of fixation implant in both groups. CONCLUSIONS: In both observer groups, 190 keV images were selected most frequently as the optimal energy to assess bone union in patients with a suspected non-union of the appendicular skeleton with hardware in situ. On average, musculoskeletal radiologists selected higher optimal and lower worst energy settings and were more confident in selecting both energy settings than orthopaedic trauma surgeons.


Subject(s)
Fractures, Ununited/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Consensus , Female , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fractures, Ununited/surgery , Humans , Male , Photons , Prospective Studies , Prostheses and Implants
19.
Eur Radiol ; 30(1): 432-441, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31428828

ABSTRACT

BACKGROUND: Kawasaki disease (KD) is a vasculitis with formation of coronary artery aneurysms (CAAs) that can lead to myocardial ischemia. Echocardiography is the primary imaging modality for the coronary arteries despite limited visualization. Coronary angiography (CAG) is the gold standard yet invasive with high-radiation exposure. To date however, state-of-the-art CT scanners enable high-quality low-dose coronary computed tomographic angiography (cCTA) imaging. The aim of our study in KD is to report (i) the diagnostic yield of cCTA compared to echocardiography, and (ii) the radiation dose. METHODS AND RESULTS: We collected data of KD patients who underwent cCTA. cCTA findings were compared with echocardiography results. In 70 KD patients (median age 15.1 years [0.5-59.5 years]; 78% male; 38% giant CAA), the cCTA identified 61 CAAs, of which 34 (56%, with a Z score > 3, in 22 patients) were not detected by echocardiography. In addition, the left circumflex (aneurysmatic in 6 patients) was always visible upon cCTA and not detected upon echocardiography. Calcifications, plaques, and/or thrombi were visualized by cCTA in 25 coronary arteries (15 patients). Calcifications were seen as early as 2.7 years after onset of disease. In 5 patients, the cCTA findings resulted in an immediate change of treatment. The median effective dose (ED) in millisievert differed significantly (p < 0.01) between third-generation dual-source and other CT scanners (1.5 [0.3-9.4] (n = 56) vs 3.8 [1.7-20.0] (n = 14)). CONCLUSIONS: The diagnostic yield of third-generation dual-source cCTA combined with reduced radiation exposure makes cCTA a favorable diagnostic modality to complete the diagnosis and long-term treatment indications for KD. KEY POINTS: • cCTA is a favorable diagnostic modality to complete the diagnosis and long-term treatment indications for Kawasaki disease. • Kawasaki disease patients with proven coronary artery involvement on echocardiography require additional imaging.


Subject(s)
Coronary Aneurysm/diagnostic imaging , Mucocutaneous Lymph Node Syndrome/diagnostic imaging , Adolescent , Adult , Child , Child, Preschool , Computed Tomography Angiography/methods , Coronary Aneurysm/etiology , Coronary Angiography/methods , Echocardiography/methods , Female , Humans , Male , Middle Aged , Mucocutaneous Lymph Node Syndrome/complications , Radiation Dosage , Radiation Exposure/analysis , Vascular Calcification/diagnostic imaging , Vascular Calcification/etiology , Young Adult
20.
Phys Med ; 69: 9-18, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31812728

ABSTRACT

PURPOSE: To quantitatively assess CT image quality and fracture visibility using virtual monochromatic imaging and iterative metal artifact reduction (iMAR) in a femoral bone fracture phantom with different fixation implants. METHODS: A custom made phantom was scanned at 120-kVp and 140-kVp single-energy and 100/150-kVp dual-energy. Three stainless steel and two titanium implants with different thicknesses were placed on the phantom containing simulated one and two mm fractures. Single-energy CT images were reconstructed with and without iMAR, while DECT images were reconstructed at monochromatic energies between 70 and 190 keV. Non-metal scans were used as a reference. A Fourier power spectrum method and fracture model were used to analyze several anatomical areas. RESULTS: CT-value deviations of titanium implants were much lower compared to stainless steel implants. These deviations decreased for both DECT and iMAR. Fracture visibility, measured with the fracture model, improved the most when DECT was used while artifact reduction benefitted more from iMAR. The optimal monochromatic energy for metal artifact reduction, based on CT-value deviation, varied for each metal between 130 and 150 keV. The fracture model provided a signal-to-noise ratio for the near metal fracture visibility, providing the optimal keV. CONCLUSION: iMAR and high keV monochromatic images extracted from DECT both reduce metal artifacts caused by different metal fixation implants. Quantitative femoral phantom results show that DECT is superior to iMAR regarding fracture visualization adjacent to metal fixation implants. The introduction of new artifacts when using iMAR impedes its value in near metal fixation implant imaging.


Subject(s)
Artifacts , Image Processing, Computer-Assisted/methods , Metals/chemistry , Tomography, X-Ray Computed , Femoral Fractures/surgery , Femur/diagnostic imaging , Femur/physiology , Fourier Analysis , Humans , Phantoms, Imaging , Prostheses and Implants , Signal-To-Noise Ratio , Titanium/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...