Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Funct Biomater ; 14(2)2023 Feb 03.
Article in English | MEDLINE | ID: mdl-36826887

ABSTRACT

The development of an ideal vascular prosthesis represents an important challenge in terms of the treatment of cardiovascular diseases with respect to which new materials are being considered that have produced promising results following testing in animal models. This study focuses on nanofibrous polycaprolactone-based grafts assessed by means of histological techniques 10 days and 6 months following suturing as a replacement for the rat aorta. A novel stereological approach for the assessment of cellular distribution within the graft thickness was developed. The cellularization of the thickness of the graft was found to be homogeneous after 10 days and to have changed after 6 months, at which time the majority of cells was discovered in the inner layer where the regeneration of the vessel wall was found to have occurred. Six months following implantation, the endothelialization of the graft lumen was complete, and no vasa vasorum were found to be present. Newly formed tissue resembling native elastic arteries with concentric layers composed of smooth muscle cells, collagen, and elastin was found in the implanted polycaprolactone-based grafts. Moreover, the inner layer of the graft was seen to have developed structural similarities to the regular aortic wall. The grafts appeared to be well tolerated, and no severe adverse reaction was recorded with the exception of one case of cartilaginous metaplasia close to the junctional suture.

2.
Polymers (Basel) ; 11(3)2019 Mar 11.
Article in English | MEDLINE | ID: mdl-30960443

ABSTRACT

Polypyrrole is one of the most investigated conductive polymers used for tissue engineering applications because of its advantageous properties and the ability to promote different cell types' adhesion and proliferation. Together with ß-cyclodextrin, which is capable of accommodating helpful biomolecules in its cavity, it would make a perfect couple for use as a scaffold for tissue engineering. Such scaffolds were prepared by the polymerisation of 6-(pyrrol-3-yl)hexanoic acid on polycaprolactone microfibres with subsequent attachment of ß-cyclodextrin on the polypyrrole layer. The materials were deeply characterised by several physical and spectroscopic techniques. Testing of the cyclodextrin enriched composite scaffold revealed its better performance in in vitro experiments compared with pristine polycaprolactone or polypyrrole covered polycaprolactone scaffolds.

3.
Acta Biomater ; 86: 312-322, 2019 03 01.
Article in English | MEDLINE | ID: mdl-30610918

ABSTRACT

Directing the organization of cells into a tissue with defined architectures is one use of biomaterials for regenerative medicine. To this end, hydrogels are widely investigated as they have mechanical properties similar to native soft tissues and can be formed in situ to conform to a defect. Herein, we describe the development of porous hydrogel tubes fabricated through a two-step polymerization process with an intermediate microsphere phase that provides macroscale porosity (66.5%) for cell infiltration. These tubes were investigated in a spinal cord injury model, with the tubes assembled to conform to the injury and to provide an orientation that guides axons through the injury. Implanted tubes had good apposition and were integrated with the host tissue due to cell infiltration, with a transient increase in immune cell infiltration at 1 week that resolved by 2 weeks post injury compared to a gelfoam control. The glial scar was significantly reduced relative to control, which enabled robust axon growth along the inner and outer surface of the tubes. Axon density within the hydrogel tubes (1744 axons/mm2) was significantly increased more than 3-fold compared to the control (456 axons/mm2), with approximately 30% of axons within the tube myelinated. Furthermore, implantation of hydrogel tubes enhanced functional recovery relative to control. This modular assembly of porous tubes to fill a defect and directionally orient tissue growth could be extended beyond spinal cord injury to other tissues, such as vascular or musculoskeletal tissue. STATEMENT OF SIGNIFICANCE: Tissue engineering approaches that mimic the native architecture of healthy tissue are needed following injury. Traditionally, pre-molded scaffolds have been implemented but require a priori knowledge of wound geometries. Conversely, hydrogels can conform to any injury, but do not guide bi-directional regeneration. In this work, we investigate the feasibility of a system of modular hydrogel tubes to promote bi-directional regeneration after spinal cord injury. This system allows for tubes to be cut to size during surgery and implanted one-by-one to fill any injury, while providing bi-directional guidance. Moreover, this system of tubes can be broadly applied to tissue engineering approaches that require a modular guidance system, such as repair to vascular or musculoskeletal tissues.


Subject(s)
Hydrogels/pharmacology , Nerve Regeneration/drug effects , Spinal Cord Injuries/physiopathology , Animals , Axons/drug effects , Axons/pathology , Cicatrix/pathology , Cross-Linking Reagents/chemistry , Female , Hindlimb/drug effects , Hindlimb/physiology , Locomotion/drug effects , Maleimides/chemistry , Mice, Inbred C57BL , Microspheres , Myelin Sheath/drug effects , Myelin Sheath/metabolism , Neuroglia/pathology , Polyethylene Glycols/chemistry , Polymerization , Porosity , Spinal Cord Injuries/pathology , Tissue Scaffolds/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...