Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32.694
Filter
1.
J Pak Med Assoc ; 74(4 (Supple-4)): S5-S9, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38712403

ABSTRACT

OBJECTIVE: To segment dental implants on PA radiographs using a Deep Learning (DL) algorithm. To compare the performance of the algorithm relative to ground truth determined by the human annotator. Methodology: Three hundred PA radiographs were retrieved from the radiographic database and consequently annotated to label implants as well as teeth on the LabelMe annotation software. The dataset was augmented to increase the number of images in the training data and a total of 1294 images were used to train, validate and test the DL algorithm. An untrained U-net was downloaded and trained on the annotated dataset to allow detection of implants using polygons on PA radiographs. RESULTS: A total of one hundred and thirty unseen images were run through the trained U-net to determine its ability to segment implants on PA radiographs. The performance metrics are as follows: accuracy of 93.8%, precision of 90%, recall of 83%, F-1 score of 86%, Intersection over Union of 86.4% and loss = 21%. CONCLUSIONS: The trained DL algorithm segmented implants on PA radiographs with high performance similar to that of the humans who labelled the images forming the ground truth.


Subject(s)
Deep Learning , Dental Implants , Humans , Algorithms , Artificial Intelligence , Radiography, Dental/methods
2.
Int J Esthet Dent ; 19(2): 107-109, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726852
3.
Int J Esthet Dent ; 19(2): 126-138, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726855

ABSTRACT

AIM: The aim of the present retrospective case series was to longitudinally assess soft tissue volume changes on the vestibular aspect of implants in relation to keratinized mucosa thickness (KMT) and width (KMW) after the application of the microsurgical envelope technique combined with a connective tissue graft (CTG). MATERIALS AND METHODS: A total of 12 healthy patients received 12 dental implants placed either in the posterior maxilla or mandible. The study involved the harvesting of 12 CTGs with a minimally invasive single-incision technique, grafted to the vestibular peri-implant soft tissue utilizing the envelope technique, followed by the insertion of 12 screw-retained IPS e.max crowns. RESULTS: The healing process was uneventful across all areas, and all patients were followed up for a period of 5 years. The evaluation of KMT showed the highest decrease in the first 6 weeks after surgery (5.5 ± 0.79 to 4.59 ± 0.62 mm), then dropped slightly to 4 ± 0.85 mm, after which it maintained at 4 ± 0.36 mm until the 2-year time point. Between the second and third years after surgery, a further decrease of 3.59 ± 0.42 mm was recorded for KMT, which then remained constant until the end of the 5-year research period. The observations regarding KMW were slightly different, with the measurements demonstrating the greatest decrease in first 6 weeks (from 2.5 ± 0.42 to 1.5 ± 0.42 mm), which was maintained until the 1-year time point. Between the first and second years after surgery, the KMW increased to 2 ± 0.60 mm and remained level for the next 3 years, at 2 ± 0.85 mm. CONCLUSIONS: The current research demonstrated the advantages of using a combination of a minimally invasively harvested CTG and the microsurgical envelope technique for a duration of 5 years.


Subject(s)
Connective Tissue , Microsurgery , Humans , Retrospective Studies , Connective Tissue/transplantation , Male , Microsurgery/methods , Female , Adult , Middle Aged , Dental Implantation, Endosseous/methods , Dental Implants , Maxilla/surgery , Mandible/surgery , Gingiva/transplantation
4.
Discov Med ; 36(184): 874-881, 2024 May.
Article in English | MEDLINE | ID: mdl-38798248

ABSTRACT

The number of chronic kidney disease (CKD) patients requiring renal replacement therapy is increasing, often exhibiting oral manifestations including periodontal disease, gingival hyperplasia, altered saliva composition, and uremic stomatitis. Uremic stomatitis, xerostomia, and candidiasis are very frequent, particularly among patients undergoing dialysis or kidney transplant recipients. CKD patients also experience profound alterations in bone metabolism inherent in the homeostasis of calcium, phosphorus, vitamin D, parathyroid hormone, and fibroblast growth factor (FGF). These alterations lead to demineralization of the jaw bones, reduced bone trabeculae, reduced cortical bone thickness, fibrocystic bone lesions, bone fractures, and delayed wound healing post-tooth extraction. Consequently, oral health management of elderly hemodialysis patients poses serious clinical problems. This review focused on the oral health and rehabilitation of patients with CKD or on dialysis.


Subject(s)
Dental Implants , Oral Health , Renal Insufficiency, Chronic , Humans , Renal Insufficiency, Chronic/complications , Renal Insufficiency, Chronic/therapy , Dental Implants/adverse effects , Oral Surgical Procedures/adverse effects , Oral Surgical Procedures/methods , Renal Dialysis/adverse effects
5.
Int J Oral Implantol (Berl) ; 17(2): 137-161, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38801329

ABSTRACT

PURPOSE: To provide an overview of the outcomes of the use of autogenous platelet concentrates in immediate implant placement. MATERIALS AND METHODS: Based on an a priori protocol, a systematic search was performed of the National Library of Medicine (MEDLINE via PubMed), Embase and Scopus databases. Randomised and non-randomised controlled clinical trials on immediate implant placement including at least one study arm with use of platelet-rich fibrin or platelet-rich plasma as a gap filler between immediately placed implants and the alveolar bone were included. A random-effects meta-analysis model was built to assess the primary outcomes of marginal bone loss and probing pocket depths between test (platelet concentrates) and control (no graft or other graft materials) groups. A risk of bias assessment was performed and the Grading of Recommendations Assessment, Development and Evaluation approach was used to assess the certainty of evidence. RESULTS: A total of 20 trials (595 immediate implants placed in 454 individuals) were included in the meta-analytic model. Based on the data from studies with a minimum post-prosthetic loading period of 6 months after immediate implant placement, overall, the application of platelet concentrates was associated with significantly lower marginal bone loss and probing pocket depth compared to the control groups (mean difference -0.36 mm; P < 0.01 and mean difference -0.47 mm; P < 0.01, respectively). No additional benefit of application of platelet concentrates was detected regarding primary stability of immediate implants. Subgroup analysis revealed significantly lower marginal bone loss with xenogeneic bone alone compared to platelet concentrates alone as grafting material in immediate implant placement (mean difference 0.66 mm; P < 0.01). Evidence on soft tissue outcomes and aesthetic parameters was scarce. CONCLUSIONS: A low level of certainty based on the Grading of Recommendations Assessment, Development and Evaluation approach indicates superior outcomes in terms of marginal bone loss and probing pocket depth in immediate implant placement with the use of platelet concentrates versus no graft. Future research should be tailored towards a standardised protocol for preparation of platelet concentrates and inclusion of soft tissue and aesthetic outcomes as well.


Subject(s)
Platelet-Rich Fibrin , Humans , Immediate Dental Implant Loading/methods , Platelet-Rich Plasma , Controlled Clinical Trials as Topic , Dental Implants/adverse effects , Alveolar Bone Loss , Prospective Studies , Treatment Outcome
6.
Int J Oral Implantol (Berl) ; 17(2): 163-172, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38801330

ABSTRACT

PURPOSE: To examine the effects of buccal bone fenestration on maxillary anterior implants. MATERIALS AND METHODS: Patients who underwent implant placement in the maxillary anterior region between January 2017 and December 2021 and had received final restorations 1 to 6 years prior were screened for inclusion in the present study. Propensity score matching was used to match the two-group sample size and reduce the influence of potential confounding factors. Generalised linear mixed models were employed to evaluate the correlation between buccal bone fenestration and peri-implant marginal bone loss. RESULTS: A total of 42 patients with 50 implants were included in the study, 16 of whom had buccal bone fenestration (group 1) and 26 of whom did not (group 2). No implant failures occurred, resulting in a cumulative implant survival rate of 100.0%. There was no statistically significant difference between the pink aesthetic scores for the two groups. The mean marginal bone loss was 0.44 ± 0.46 mm for group 1 and 0.33 ± 0.32 mm for group 2 (P > 0.05). Buccal bone fenestration was not the influencing factor of marginal bone loss (P > 0.05). Marginal bone loss was greater around implants used to replace canines than those inserted to replace central incisors (P < 0.05). Far less marginal bone loss occurred around immediately loaded implants than delayed implants with cover screws (P < 0.05). When there is sufficient keratinised mucosa around the implant, marginal bone loss will decrease significantly (P < 0.05). CONCLUSIONS: Within the limitations of this study, buccal bone fenestration defects around dental implants cannot influence peri-implant bone loss. CONFLICT-OF-INTEREST STATEMENT: The authors report no conflicts of interest relating to this study.


Subject(s)
Alveolar Bone Loss , Dental Implants , Maxilla , Humans , Retrospective Studies , Male , Maxilla/surgery , Female , Middle Aged , Adult , Dental Implantation, Endosseous/methods , Aged , Propensity Score
7.
Head Face Med ; 20(1): 33, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38760840

ABSTRACT

BACKGROUND: Dental cone beam computed tomography (CBCT) is commonly used to evaluate cancellous bone density before dental implant surgery. However, to our knowledge, no measurement approach has been standardized yet. This study aimed to evaluate the relationship between three different regions of interest (ROI) methods on cancellous bone density at the dental implant site using dental CBCT images. METHODS: Patients' dental CBCT images (n = 300) obtained before dental implant surgery were processed using Mimics (Materialise, Leuven, Belgium). At the potential implant sites, the rectangle, cylinder, and surrounding cylinder ROI methods were used to measure bone density. Repeated measures one-way analysis of variance was performed to compare the three ROI methods in terms of measurement results. Pearson correlation analysis was performed to identify the likely pair-wise correlations between the three ROI methods. RESULTS: The density value obtained using the surrounding cylinder approach (grayscale value [GV],523.56 ± 228.03) was significantly higher than the values obtained using the rectangle (GV, 497.04 ± 236.69) and cylinder (GV,493 ± 231.19) ROI methods in terms of results. Furthermore, significant correlations were noted between the ROI methods (r > 0.965; p < 0.001). CONCLUSIONS: The density measured using the surrounding cylinder method was the highest. The choice of method may not influence the trends of measurement results. TRIAL REGISTRATION: This study was approved by the Institutional Review Board of China Medical University Hospital, No. CMUH111-REC3-205. Informed consent was waived by the Institutional Review Board of China Medical University Hospital, CMUH111-REC3-205, owing to the retrospective nature of the study.


Subject(s)
Bone Density , Cone-Beam Computed Tomography , Humans , Cone-Beam Computed Tomography/methods , Female , Male , Middle Aged , Adult , Aged , Retrospective Studies , Preoperative Care/methods , Dental Implantation/methods , Young Adult , Dental Implants , Dental Implantation, Endosseous/methods
9.
Dental Press J Orthod ; 29(2): e2423282, 2024.
Article in English | MEDLINE | ID: mdl-38775601

ABSTRACT

OBJECTIVE: This study aimed to compare the insertion torque (IT), flexural strength (FS) and surface alterations between stainless steel (SS-MIs) and titanium alloy (Ti-MIs) orthodontic mini-implants. METHODS: Twenty-four MIs (2 x 10 mm; SS-MIs, n = 12; Ti-MIs, n = 12) were inserted on artificial bone blocks of 20 lb/ft3 (20 PCF) and 40 lb/ft3 (40 PCF) density. The maximum IT was recorded using a digital torque meter. FS was evaluated at 2, 3 and 4 mm-deflection. Surface topography and chemical composition of MIs were assessed by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). General linear and mixed models were used to assess the effect of the MI type, bone density and deflection on the evaluated outcomes. RESULTS: The IT of Ti-MIs was 1.1 Ncm greater than that obtained for the SS-MIs (p= 0.018). The IT for MIs inserted in 40 PCF test blocks was 5.4 Ncm greater than that for those inserted in 20 PCF test blocks (p < 0.001). SS-MIs inserted in higher density bone (40 PCF) had significantly higher flexural strength than the other groups, at 2 mm (98.7 ± 5.1 Ncm), 3 mm (112.0 ± 3.9 Ncm) and 4 mm (120.0 ± 3.4 Ncm) of deflection (p< 0.001). SEM evidenced fractures in the Ti-MIs. EDS revealed incorporation of 18% of C and 2.06% of O in the loaded SS-MIs, and 3.91% of C in the loaded Ti-MIs. CONCLUSIONS: Based on the findings of this in vitro study, it seems that SS-MIs offer sufficient stability and exhibit greater mechanical strength, compared to Ti-MIs when inserted into higher density bone.


Subject(s)
Dental Alloys , Dental Implants , Flexural Strength , Materials Testing , Microscopy, Electron, Scanning , Orthodontic Anchorage Procedures , Stainless Steel , Surface Properties , Titanium , Torque , Titanium/chemistry , Stainless Steel/chemistry , Orthodontic Anchorage Procedures/instrumentation , Orthodontic Anchorage Procedures/methods , Dental Alloys/chemistry , In Vitro Techniques , Spectrometry, X-Ray Emission , Dental Stress Analysis , Humans , Stress, Mechanical , Bone Density
10.
PLoS One ; 19(5): e0290595, 2024.
Article in English | MEDLINE | ID: mdl-38776308

ABSTRACT

Non-invasive objective implant stability measurements are needed to determine the appropriate timing of prosthetic fitting after implant placement. We compared the early implant stability results obtained using resonance frequency analysis (RFA) and damping capacity analysis (DCA) depending on the implant length and bone density. Total 60, 4.0 mm diameter implants of various lengths (7.3 mm, 10 mm, and 13 mm) were used. In Group I, low-density bone was described using 15 PCF (0.24 g/cm3) polyurethane bone blocks, and in Group II, 30 PCF (0.48 g/cm3) polyurethane bone blocks were used to describe medium density bone. RFA was performed using an Osstell® Beacon+; DCA was performed using Anycheck®. Measurements were repeated five times for each implant. Statistical significance was set at P <0.05. In Group I, bone density and primary implant stability were positively correlated, while implant length and primary implant stability were positively correlated. In Group II, the implant stability quotient (ISQ) and implant stability test (IST) values in did not change significantly above a certain length. Primary implant stability was positively correlated with bone density and improved with increasing implant length at low bone densities. Compared with the Osstell® Beacon+, the simplicity of Anycheck® was easy to use and accessible.


Subject(s)
Bone Density , Dental Implants , Humans , Resonance Frequency Analysis , Dental Implantation, Endosseous/methods , Dental Implantation, Endosseous/instrumentation
11.
BMC Oral Health ; 24(1): 596, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38778269

ABSTRACT

BACKGROUND: Dynamic navigation for implant placement is becoming popular under the concept of top-down treatment. The purpose of this study is to verify the accuracy of a dynamic navigation system for implant placement. METHODS: Implant placement was performed on 38 patients using 50 implant fixtures. Patients in group C were treated using a conventional method, in which thermoplastic clips were fixed to the teeth, and patients in group M were treated using thermoplastic clips fixed to a mouthpiece attached to the teeth. The groups were compared to verify whether an accuracy difference existed. A treatment planning support program for dental implants was used to superimpose the postoperative computed tomography data on the preoperative implant design data to measure the entry point, apex point, and angular deviation. RESULTS: The accuracy of group C was 1.36 ± 0.51 mm for entry point, 1.30 ± 0.59 mm for apex point, and 3.20 ± 0.74° for angular deviation. The accuracy of group M was 1.06 ± 0.31 mm for the entry point, 1.02 ± 0.30 mm for the apex point, and 2.91 ± 0.97° for angular deviation. Significant differences were observed in the entry and apex points between the two groups. CONCLUSIONS: The results indicate that group M exhibited better accuracy than group C, indicating that the stability of the thermoplastic clip is important for ensuring the accuracy of the dynamic navigation system. No previous studies have verified the accuracy of this system using the mouthpiece method, and additional data is required to confirm its accuracy for dental implant placement. The mouthpiece method improves the accuracy of implant placement and provides a safer implant treatment than the conventional method. TRIAL REGISTRATION: University hospital Medical Information Network Clinical Trials Registry (UMIN-CTR), Registration Number: UMIN000051949, URL: https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view_his.cgi on August 21, 2023.


Subject(s)
Dental Implantation, Endosseous , Humans , Male , Female , Dental Implantation, Endosseous/methods , Middle Aged , Surgery, Computer-Assisted/methods , Tomography, X-Ray Computed , Surgical Navigation Systems , Adult , Dental Implants , Aged , Patient Care Planning
12.
BMC Oral Health ; 24(1): 600, 2024 May 23.
Article in English | MEDLINE | ID: mdl-38778313

ABSTRACT

OBJECTIVES: To assess the accuracy of implant placement in models and satisfaction in dynamic navigation assisted postgraduate dental students training. METHODS: Postgraduate dental students who had at least one year of dental clinical practice with no experience in dental implant surgeries were included. Students were instructed to make treatment plans in the dynamic navigation system. Each student placed two maxillary right incisors, using freehand approach at first and then under dynamic navigation. The implant position was compared with treatment plan. Factors influencing the accuracy of implants placed under dynamic navigation were analyzed. Student acceptance towards the training and use of dynamic navigation was recorded using a questionnaire. RESULTS: A total of 21 students placed 42 implants. For freehand implant placement, the median entry point deviation, apex point deviation, and implant axis deviation was 3.79 mm, 4.32 mm, and 10.08°. For dynamic guided implant placement, the median entry point deviation, apex point deviation, and implant axis deviation was 1.29 mm, 1.25 mm, and 4.89° (p < 0.001). The accuracy of dynamic guided implant was not influenced by student gender or familiarity with computer games. All students were satisfied with the training. CONCLUSIONS: Dynamic navigation system assisted students in improving the accuracy of implant placement and was well accepted by students.


Subject(s)
Students, Dental , Humans , Female , Male , Surgery, Computer-Assisted/methods , Education, Dental, Graduate , Dental Implantation, Endosseous , In Vitro Techniques , Education, Dental/methods , Dental Implants , Surveys and Questionnaires , Dental Implantation/education , Clinical Competence
13.
PLoS One ; 19(5): e0304091, 2024.
Article in English | MEDLINE | ID: mdl-38781146

ABSTRACT

OBJECTIVE: To date, it remains a challenge to conduct maxillary sinus floor elevation (MSFE) owing to heterogeneity of anatomical structures and limited operative visibility of the maxillary sinus. The aim of this study is to investigate the safety of MSFE and the accuracy of implant placement using dynamic navigation. METHODS: Forty-two implants were placed in thirty-five patients requiring implantation in posterior maxilla with dynamic navigation. They were assigned to either lateral window sinus floor elevation (LWSFE) group (n = 22) or transcrestal sinus floor elevation (TSFE) group (n = 20) according to the residual alveolar bone height (RBH). Platform deviation, apex deviation and angular deviation between actual and planned implant placement were measured in precision evaluation software. Three deviations of two groups were compared via SPSS 22.0 software. RESULTS: Neither accidental bleeding nor perforation of Schneiderian membrane occurred in any patients. The actual window position of LWSFE was consistent with the preoperative design. There were no significant differences in platform, apex and angular deviations between the two groups (P > 0.05). CONCLUSION: In this study the dynamic navigation harvested clinically acceptable safety of MSFE and accuracy for implant placement in posterior maxillary region. The dynamic navigation would provide the clinician with assistance in achieving precise preoperative planning and reducing complications in surgical procedures. The granular bone grafts used in the LWSFE did not significantly affection on the accuracy of the simultaneous implant placement under the guidance of dynamic navigation.


Subject(s)
Maxillary Sinus , Sinus Floor Augmentation , Humans , Male , Female , Middle Aged , Sinus Floor Augmentation/methods , Maxillary Sinus/surgery , Adult , Aged , Dental Implants , Dental Implantation, Endosseous/methods , Dental Implantation, Endosseous/adverse effects , Maxilla/surgery , Surgery, Computer-Assisted/methods
14.
Wiad Lek ; 77(3): 462-471, 2024.
Article in English | MEDLINE | ID: mdl-38691788

ABSTRACT

OBJECTIVE: Aim: To study the specifics of the impact of immediate intraoperative loading with a splinting component on supporting tissues during a one-stage implantation protocol. PATIENTS AND METHODS: Materials and Methods: In the course of the study, orthopedic treatment was carried out for 55 patients aged 29 to 60 years. The following were performed: cone-beam computed tomography, software planning and intraoral scanning with an optical scanner, one-stage implantation protocol, assessment of implant stability with the Osstell ISQ device, microcirculation study in the peri-implant area using laser Doppler flowmetry (LDF). RESULTS: Results: It was established that around loaded implants there is an increase in blood flow and vasomotor activity of the microcirculatory channel of the supporting tissues, an increase in the volume of bone tissue and an increase in torque, which is the optimal forecast for the acceleration of the pace of osseointegration. CONCLUSION: Conclusions: The use of a splinting component during immediate intraoperative functional masticatory load accelerates the dynamics of bone tissue remodeling processes around the implant, which is an optimal prediction of osseointegration rates in various dental implantation protocols and is consistent with high values of the implant stability coefficient.


Subject(s)
Immediate Dental Implant Loading , Humans , Middle Aged , Adult , Male , Female , Splints , Osseointegration , Dental Implants , Dental Implantation, Endosseous/methods , Cone-Beam Computed Tomography
15.
J Contemp Dent Pract ; 25(3): 276-279, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38690702

ABSTRACT

AIM: The current study was carried out to assess the interaction between fibrin clots and dental implants following various surface treatments. MATERIALS AND METHODS: In this investigation, 45 dental implants with dimensions of 16 mm in length and 5 mm in diameter were utilized. They were divided up into three groups, each consisting of fifteen samples. Group I: Control; Group II: Ultraviolet (UV) light treated; and group III: Sandblasted and acid-etching (SLA) treated. Healthy volunteers' venous blood samples were drawn into vacutainer tubes without the use of anticoagulants. The samples were centrifuged for 3 minutes at 2700 rpm in a table centrifuge. The entire implant was submerged in room-temperature liquid fibrinogen for 60 minutes. Then, scanning electronic microscopy (SEM) was used to examine each sample. The inter- and intragroup assessments were obtained using the Mann-Whitney U test and the Kruskal-Wallis test; p-values less than 0.05 were regarded as statistically significant. RESULTS: The maximum adhesion of fibrin clot was found in SLA treated group (2.42 ± 0.10) followed by the UV light-treated group (2.18 ± 0.08) and control group (1.20 ± 0.02). There was a statistically significant difference found between the three surface-treated groups (p < 0.001). CONCLUSION: All surface-treatment methods exhibit adhesion between the implant surface and the fibrin clot. However, the highest adherence of fibrin clot was found in SLA treated group compared to the UV light-treated and control group. CLINICAL SIGNIFICANCE: The physical and chemical characteristics of an implant's surface have a significant impact on the way blood clots organize. At the interface between the implant and the bone, blood clot production can initiate and facilitate the healing process. How to cite this article: Jalaluddin M, Ramanna PK, Swain M, et al. Evaluation of Fibrin Clot Interaction with Dental Implant after Different Surface Treatments: An In Vitro Study. J Contemp Dent Pract 2024;25(3):276-279.


Subject(s)
Dental Implants , Fibrin , Microscopy, Electron, Scanning , Surface Properties , Humans , In Vitro Techniques , Blood Coagulation , Ultraviolet Rays , Acid Etching, Dental
16.
BMC Oral Health ; 24(1): 558, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38741081

ABSTRACT

BACKGROUND: We investigated the efficacy of two different cold atmospheric pressure jet plasma devices (CAP09 and CAPmed) and an air polishing device with glycine powder (AP) either applied as monotherapies or combined therapies (AP + CAP09; AP + CAPmed), in microbial biofilm removal from discs with anodised titanium surface. METHODS: Discs covered with 7-day-old microbial biofilm were treated either with CAP09, CAPmed, AP, AP + CAP09 or AP + CAPmed and compared with negative and positive controls. Biofilm removal was assessed with flourescence and electron microscopy immediately after treatment and after 5 days of reincubation of the treated discs. RESULTS: Treatment with CAP09 or CAPmed did not lead to an effective biofilm removal, whereas treatment with AP detached the complete biofilm, which however regrew to baseline magnitude after 5 days of reincubation. Both combination therapies (AP + CAP09 and AP + CAPmed) achieved a complete biofilm removal immediately after cleaning. However, biofilm regrew after 5 days on 50% of the discs treated with the combination therapy. CONCLUSION: AP treatment alone can remove gross biofilm immediately from anodised titanium surfaces. However, it did not impede regrowth after 5 days, because microorganisms were probably hidden in holes and troughs, from which they could regrow, and which were inaccessible to AP. The combination of AP and plasma treatment probably removed or inactivated microorganisms also from these hard to access spots. These results were independent of the choice of plasma device.


Subject(s)
Biofilms , Dental Implants , Plasma Gases , Surface Properties , Titanium , Biofilms/drug effects , Titanium/chemistry , Dental Implants/microbiology , Dental Polishing/methods , Glycine , Humans , In Vitro Techniques , Microscopy, Electron, Scanning , Nickel
17.
Mil Med Res ; 11(1): 29, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38741175

ABSTRACT

Peri-implantitis is a bacterial infection that causes soft tissue inflammatory lesions and alveolar bone resorption, ultimately resulting in implant failure. Dental implants for clinical use barely have antibacterial properties, and bacterial colonization and biofilm formation on the dental implants are major causes of peri-implantitis. Treatment strategies such as mechanical debridement and antibiotic therapy have been used to remove dental plaque. However, it is particularly important to prevent the occurrence of peri-implantitis rather than treatment. Therefore, the current research spot has focused on improving the antibacterial properties of dental implants, such as the construction of specific micro-nano surface texture, the introduction of diverse functional coatings, or the application of materials with intrinsic antibacterial properties. The aforementioned antibacterial surfaces can be incorporated with bioactive molecules, metallic nanoparticles, or other functional components to further enhance the osteogenic properties and accelerate the healing process. In this review, we summarize the recent developments in biomaterial science and the modification strategies applied to dental implants to inhibit biofilm formation and facilitate bone-implant integration. Furthermore, we summarized the obstacles existing in the process of laboratory research to reach the clinic products, and propose corresponding directions for future developments and research perspectives, so that to provide insights into the rational design and construction of dental implants with the aim to balance antibacterial efficacy, biological safety, and osteogenic property.


Subject(s)
Biocompatible Materials , Dental Implants , Peri-Implantitis , Peri-Implantitis/therapy , Peri-Implantitis/prevention & control , Peri-Implantitis/drug therapy , Humans , Dental Implants/standards , Biocompatible Materials/therapeutic use , Biocompatible Materials/pharmacology , Biofilms/drug effects , Surface Properties , Anti-Bacterial Agents/therapeutic use , Anti-Bacterial Agents/pharmacology
18.
Bull Exp Biol Med ; 176(5): 620-625, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38733480

ABSTRACT

We studied the interaction of human buccal mesenchymal stem cells (MSCs) and osteoblasts differentiated from them with the surface of titanium samples. MSCs were isolated by enzymatic method from buccal fat pads. The obtained cell culture was presented by MSCs, which was confirmed by flow cytometry and differentiation into adipocytes and osteoblasts. Culturing of buccal MSCs on titanium samples was accompanied by an increase in the number of cells for 15 days and the formation of a developed network of F-actin fibers in the cells. The viability of buccal MSCs decreased by 8 days, but was restored by 15 days. Culturing of osteoblasts obtained as a result of buccal MSC differentiation on the surface of titanium samples was accompanied by a decrease in their viability and proliferation. Thus, MSCs from buccal fat pads can be used to coat implants to improve osseointegration during bone reconstruction in craniofacial surgery and dentistry. To improve the integration of osteoblasts, modification of the surface of titanium samples is required.


Subject(s)
Cell Differentiation , Mesenchymal Stem Cells , Osseointegration , Osteoblasts , Titanium , Titanium/chemistry , Mesenchymal Stem Cells/cytology , Mesenchymal Stem Cells/physiology , Humans , Osseointegration/physiology , Osteoblasts/cytology , Osteoblasts/physiology , Cells, Cultured , Cell Proliferation , Dental Implants , Cell Survival , Adipocytes/cytology , Adipocytes/physiology , Mouth Mucosa/cytology , Osteogenesis/physiology
19.
Clin Oral Investig ; 28(6): 313, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38748295

ABSTRACT

OBJECTIVES: This randomized clinical trial focused on patients with thin peri-implant soft-tissue height (STH) (≤ 2.5 mm) and investigated the impact of an allogenic collagen scaffold (aCS) on supracrestal tissue height and marginal bone loss (MBL). MATERIAL & METHODS: Forty patients received bone level implants and were randomly assigned to the test group with simultaneous tissue thickening with aCS or the control group. After three months, prosthetic restoration occurred. STH measurements were taken at baseline (T0) and reopening surgery (TR), with MBL assessed at 12 months (T1). Descriptive statistics were calculated for continuous variables, and counts for categorical variables (significance level, p = 0.05). RESULTS: At T1, 37 patients were available. At T0, control and test groups had mean STH values of 2.3 ± 0.3 mm and 2.1 ± 0.4 mm. TR revealed mean STH values of 2.3 ± 0.2 mm (control) and 2.6 ± 0.7 mm (test), with a significant tissue thickening of 0.5 ± 0.6 mm in the test group (p < 0.03). At T1, control and test groups showed MBL mean values of 1.1 ± 0.8 mm and 1.0 ± 0.6 mm, with a moderate but significant correlation with STH thickening (-0.34), implant position (0.43), history of periodontitis (0.39), and smoking status (0.27). CONCLUSION: The use of an aCS protocol resulted in soft tissue thickening but did not reach a threshold to reliably reduce MBL compared to the control group within the study's limitations. CLINICAL RELEVANCE: Peri-implant STH is crucial for maintaining peri-implant marginal bone stability. Marginal bone stability represents a crucial factor in prevention of peri-implantitis development. German register of clinical trial registration number DRKS00033290.


Subject(s)
Alveolar Bone Loss , Collagen , Tissue Scaffolds , Humans , Male , Female , Middle Aged , Alveolar Bone Loss/prevention & control , Treatment Outcome , Dental Implantation, Endosseous/methods , Adult , Aged , Dental Implants
20.
Sci Rep ; 14(1): 10717, 2024 05 10.
Article in English | MEDLINE | ID: mdl-38730018

ABSTRACT

In reconstructive surgery, complications post-fibula free flap (FFF) reconstruction, notably peri-implant hyperplasia, are significant yet understudied. This study analyzed peri-implant hyperplastic tissue surrounding FFF, alongside peri-implantitis and foreign body granulation (FBG) tissues from patients treated at the Department of Oral and Maxillofacial Surgery, Seoul National University Dental Hospital. Using light microscopy, pseudoepitheliomatous hyperplasia, anucleate and pyknotic prickle cells, and excessive collagen deposition were observed in FFF hyperplastic tissue. Ultrastructural analyses revealed abnormal structures, including hemidesmosome dilation, bacterial invasion, and endoplasmic reticulum (ER) swelling. In immunohistochemical analysis, unfolded protein-response markers ATF6, PERK, XBP1, inflammatory marker NFκB, necroptosis marker MLKL, apoptosis marker GADD153, autophagy marker LC3, epithelial-mesenchymal transition, and angiogenesis markers were expressed variably in hyperplastic tissue surrounding FFF implants, peri-implantitis, and FBG tissues. NFκB expression was higher in peri-implantitis and FBG tissues compared to hyperplastic tissue surrounding FFF implants. PERK expression exceeded XBP1 significantly in FFF hyperplastic tissue, while expression levels of PERK, XBP1, and ATF6 were not significantly different in peri-implantitis and FBG tissues. These findings provide valuable insights into the interconnected roles of ER stress, necroptosis, apoptosis, and angiogenesis in the pathogenesis of oral pathologies, offering a foundation for innovative strategies in dental implant rehabilitation management and prevention.


Subject(s)
Dental Implants , Hyperplasia , Humans , Female , Dental Implants/adverse effects , Male , Middle Aged , Hyperplasia/pathology , Hyperplasia/metabolism , Adult , Aged , Immunohistochemistry , Peri-Implantitis/metabolism , Peri-Implantitis/pathology , Peri-Implantitis/etiology , Fibula/pathology , Fibula/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...