Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
Artículo en Inglés | MEDLINE | ID: mdl-38628954

RESUMEN

This paper reports a microfabricated triaxial capacitive force sensor. The sensor is fully encapsulated with inert and biocompatible glass (fused silica) material. The sensor comprises two glass plates, on which four capacitors are located. The sensor is intended for subdermal implantation in fingertips and palms and providing tactile sensing capabilities for patients with paralyzed hands. Additional electronic components, such as passives and IC chips, can also be integrated with the sensor in a hermetic glass package to achieve an implantable tactile sensing system. Through attachment to a human palm, the sensor has been shown to respond appropriately to typical hand actions, such as squeezing or picking up a bottle.

3.
Nanoscale ; 16(11): 5613-5623, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38412042

RESUMEN

Modern silicone-based epidermal electronics engineered for body temperature sensing represent a pivotal development in the quest for advancing preventive medicine and enhancing post-surgical monitoring. While these compact and highly flexible electronics empower real-time monitoring in dynamic environments, a noteworthy limitation is the challenge in regulating the infiltration or obstruction of heat from the external environment into the surface layers of these electronics. The study presents a cost-effective temperature sensing solution by embedding wireless electronics in a multi-layered elastomeric composite to meet the dual needs of enhanced thermal insulation for encapsulation in contact with air and improved thermal conductivity for the substrate in contact with the skin. The encapsulating composite benefits from the inclusion of hollow silica microspheres, which reduce the thermal conductivity by 40%, while non-spherical aluminum nitride enhances the thermal conductivity of the substrate by 370%. The addition of particles to the respective composites inevitably leads to an increase in modulus. Two composite elements are engineered to coexist while maintaining a matching low modulus of 3.4 MPa and a stretchability exceeding 30%, all without compromising the optimized thermal properties. Consecutive thermal, electrical, and mechanical characterization confirms the sensor's capacity for precise body temperature monitoring during a single day's lifespan, while also assessing the influence of behavioral factors on body temperature.

4.
Microsyst Nanoeng ; 9: 130, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37829157

RESUMEN

The sense of touch is critical to dexterous use of the hands and thus an essential component of efforts to restore hand function after amputation or paralysis. Prosthetic systems have addressed this goal with wearable tactile sensors. However, such wearable sensors are suboptimal for neuroprosthetic systems designed to reanimate a patient's own paralyzed hand. Here, we developed an implantable tactile sensing system intended for subdermal placement. The system is composed of a microfabricated capacitive pressure sensor, a custom integrated circuit supporting wireless powering and data transmission, and a laser-fused hermetic silica package. The miniature device was validated through simulations, benchtop assessment, and testing in a primate hand. The sensor implanted in the fingertip accurately measured applied skin forces with a resolution of 4.3 mN. The output from this novel sensor could be encoded in the brain with microstimulation to provide tactile feedback. More broadly, the materials, system design, and fabrication approach establish new foundational capabilities for various applications of implantable sensing systems.

5.
Res Sq ; 2023 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-36778258

RESUMEN

The sense of touch is critical to dexterous use of the hands and thus an essential component to efforts to restore hand function after amputation or paralysis. Prosthetic systems have focused on wearable tactile sensors. But wearable sensors are suboptimal for neuroprosthetic systems designed to reanimate a patient's own paralyzed hand. Here, we developed an implantable tactile sensing system intended for subdermal placement. The system is composed of a microfabricated capacitive force sensor, a custom integrated circuit supporting wireless powering and data transmission, and a laser-fused hermetic silica package. The miniature device was validated through simulations, benchtop testing, and ex vivo testing in a primate hand. The sensor implanted in the fingertip accurately measured skin forces with a resolution of 4.3 mN. The output from this novel sensor could be encoded in the brain with microstimulation to provide tactile feedback. More broadly, the materials, system design, and fabrication approach establish new foundational capabilities for various applications of implantable sensing systems.

6.
ACS Appl Mater Interfaces ; 15(5): 6807-6816, 2023 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-36700920

RESUMEN

Small-scale, primary electrochemical energy storage devices ("microbatteries") are critical power sources for microelectromechanical system (MEMS)-based sensors and actuators. However, the achievable volumetric and gravimetric energy densities of microbatteries are typically insufficient for intermediate-term applications of MEMS-enabled distributed internet-connected devices. Further, in the increasing subset of Internet of Things (IoT) nodes, where actuation is desired, the peak power density of the microbattery must be simultaneously considered. Metal-air approaches to achieving microbatteries are attractive, as the anode and cathode are amenable to miniaturization; however, further improvements in energy density can be obtained by minimizing the electrolyte volume. To investigate these potential improvements, this work studied very lean hydrogel electrolytes based on poly(vinyl alcohol) (PVA). Integration of high potassium hydroxide (KOH) loading into the PVA hydrogel improved electrolyte performance. The addition of potassium carbonate (K2CO3) to the KOH-PVA gel decreased the carbonation consumption rate of KOH in the gel electrolyte by 23.8% compared to PVA-KOH gel alone. To assess gel performance, a microbattery was formed from a zinc (Zn) anode layer, a gel electrolyte layer, and a carbon-platinum (C-Pt) air cathode layer. Volumetric energy densities of approximately 1400 Wh L-1 and areal peak power densities of 139 mW cm-2 were achieved with a PVA-KOH-K2CO3 electrolyte. Further structural optimization, including using multilayer gel electrolytes and thinning the air cathode, resulted in volumetric and gravimetric energy densities of 1576 Wh L-1 and 420 Wh kg-1, respectively. The batteries described in this work are manufactured in an open environment and fabricated using a straightforward layer-by-layer method, enabling the potential for high fabrication throughput in a MEMS-compatible fashion.

7.
Microsyst Nanoeng ; 7: 96, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34900330

RESUMEN

Impedance-based protein detection sensors for point-of-care diagnostics require quantitative specificity, as well as rapid or real-time operation. Furthermore, microfabrication of these sensors can lead to the formation of factors suitable for in vivo operation. Herein, we present microfabricated needle-shaped microwell impedance sensors for rapid-sample-to-answer, label-free detection of cytokines, and other biomarkers. The microneedle form factor allows sensors to be utilized in transcutaneous or transvascular sensing applications. In vitro, experimental characterization confirmed sensor specificity and sensitivity to multiple proteins of interest. Mechanical characterization demonstrated sufficient microneedle robustness for transcutaneous insertion, as well as preserved sensor function postinsertion. We further utilized these sensors to carry out real-time in vivo quantification of human interleukin 8 (hIL8) concentration levels in the blood of transgenic mice that endogenously express hIL8. To assess sensor functionality, hIL8 concentration levels in serum samples from the same mice were quantified by ELISA. Excellent agreement between real-time in vivo sensor readings in blood and subsequent ELISA serum assays was observed over multiple transgenic mice expressing hIL8 concentrations from 62 pg/mL to 539 ng/mL.

8.
Sci Adv ; 7(27)2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-34193414

RESUMEN

A non-faradaic label-free cortisol sensing platform is presented using a nanowell array design, in which the two probe electrodes are integrated within the nanowell structure. Rapid and low volume (≤5 µl) sensing was realized through functionalizing nanoscale volume wells with antibodies and monitoring the real-time binding events. A 28-well plate biochip was built on a glass substrate by sequential deposition, patterning, and etching steps to create a stack nanowell array sensor with an electrode gap of 40 nm. Sensor response for cortisol concentrations between 1 and 15 µg/dl in buffer solution was recorded, and a limit of detection of 0.5 µg/dl was achieved. Last, 65 human serum samples were collected to compare the response from human serum samples with results from the standard enzyme-linked immunosorbent assay (ELISA). These results confirm that nanowell array sensors could be a promising platform for point-of-care testing, where real-time, laboratory-quality diagnostic results are essential.


Asunto(s)
Técnicas Biosensibles , Hidrocortisona , Anticuerpos , Técnicas Biosensibles/métodos , Electrodos , Humanos , Inmunoensayo
9.
IEEE Trans Neural Netw Learn Syst ; 32(9): 4086-4095, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32881690

RESUMEN

Bottom-up-fabricated crossbars promise superior circuit density and 3-D integrability compared with the traditional CMOS-based implementations. However, their inherent stochasticity presents difficulties in building complex circuits from components that demand precise patterning and high registration accuracies. With fewer terminals than active devices, passive components offer higher device densities and registration tolerances, making them amenable to bottom-up synthesized nanocrossbars. Motivated by this preference for passivity, we explore, in this article, neuromorphic classifiers based on passive neurons and passive synapses. We demonstrate via SPICE simulations how a shallow network of the diode-resistor-based passive rectifier neurons and resistive voltage summers, despite its inherent inability to buffer, amplify, and negate signals, can recognize MNIST digits with 95.4% accuracy. We introduce weight-to-conductance mappings that enable negative weights to be implemented in hardware without excessive memory overheads. The influences of soft and hard defects on the classification performance are evaluated, and the methods to boost fault-tolerance are proposed. The first-order evaluation of the area, speed, and power consumption of the passive multilayer perceptron classifiers is undertaken, and the results are compared with a benchmark study in neuromorphic hardware.

10.
Artículo en Inglés | MEDLINE | ID: mdl-31179160

RESUMEN

This study presents the development and characterization of biodegradable electrical interconnects for transient implantable medical devices. The interconnects comprised micropatterned biodegradable conductive polymer composites, which were developed using iron (Fe) microparticles as the conductive filler and polycaprolactone (PCL) as the insulating matrix. The electrical properties of the composites were investigated under various degradation conditions. Electrical percolation was observed at 17% iron volume fraction, but higher volume fractions exhibited more stable electrical resistivity throughout the time course of physiological degradation. The electrical resistivity of 40%vf Fe-PCL composites increased tenfold in an emulated packaged environment under degradation. Biodegradable electrical interconnects based on 40%vf Fe-PCL composites were successfully micropatterned in daisy chain structures, illustrating the process compatibility of Fe-PCL composites for interconnect applications. The electrical resistance of the packaged daisy chain structures exhibited a reasonable increase under degradation. An electrical lifetime of over 5 days was also achieved. System integration with a commercial humidity sensor and analytical calculations supporting other application scenarios confirmed the feasibility of micropatterned Fe-PCL interconnects for use in implantable electrical systems.

11.
PLoS One ; 13(11): e0206137, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30383805

RESUMEN

Intracranial electrodes are a vital component of implantable neurodevices, both for acute diagnostics and chronic treatment with open and closed-loop neuromodulation. Their performance is hampered by acute implantation trauma and chronic inflammation in response to implanted materials and mechanical mismatch between stiff synthetic electrodes and pulsating, natural soft host neural tissue. Flexible electronics based on thin polymer films patterned with microscale conductive features can help alleviate the mechanically induced trauma; however, this strategy alone does not mitigate inflammation at the device-tissue interface. In this study, we propose a biomimetic approach that integrates microscale extracellular matrix (ECM) coatings on microfabricated flexible subdural microelectrodes. Taking advantage of a high-throughput process employing micro-transfer molding and excimer laser micromachining, we fabricate multi-channel subdural microelectrodes primarily composed of ECM protein material and demonstrate that the electrochemical and mechanical properties match those of standard, uncoated controls. In vivo ECoG recordings in rodent brain confirm that the ECM microelectrode coatings and the protein interface do not alter signal fidelity. Astrogliotic, foreign body reaction to ECM coated devices is reduced, compared to uncoated controls, at 7 and 30 days, after subdural implantation in rat somatosensory cortex. We propose microfabricated, flexible, biomimetic electrodes as a new strategy to reduce inflammation at the device-tissue interface and improve the long-term stability of implantable subdural electrodes.


Asunto(s)
Biomimética , Materiales Biocompatibles Revestidos/química , Electrodos Implantados , Microelectrodos , Animales , Corteza Cerebral/fisiología , Materiales Biocompatibles Revestidos/uso terapéutico , Electrocorticografía , Matriz Extracelular/química , Microtecnología/métodos , Polímeros/química , Polímeros/uso terapéutico , Ratas , Espacio Subdural/fisiología
12.
ACS Appl Mater Interfaces ; 10(43): 37643-37650, 2018 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-30288975

RESUMEN

We introduce solution-based, room temperature- and atmospheric pressure-processed silver nanocrystal (Ag NC)-based electrical circuits and interconnects for radio frequency (RF)/microwave frequency applications. We chemically designed the surface and interface states of Ag NC thin films to achieve high stability, dc and ac conductivity, and minimized RF loss through stepwise ligand exchange, shell coating, and surface cleaning. The chemical and structural properties of the circuits and interconnects affect the high-frequency electrical performance of Ag NC thin films, as confirmed by high-frequency electromagnetic field simulations. An all solution-based process is developed to build coplanar structures, in which Ag NC thin films are positioned at both sides of the substrates. In addition, we fabricated flexible transmission lines and broadband electrical circuits for resistors, interdigitated capacitors, spiral and omega-shaped inductors, and patch antennas with maximum inductance and capacitance values of 3 nH and 2.5 pF at frequencies up to 20 GHz. We believe that our approach will lead to a cost-effective realization of RF circuits and devices in which sensing and wireless communication capabilities are combined for internet-of-things applications.

13.
Microsyst Nanoeng ; 4: 30, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-31057918

RESUMEN

Intracortical neural microelectrodes, which can directly interface with local neural microcircuits with high spatial and temporal resolution, are critical for neuroscience research, emerging clinical applications, and brain computer interfaces (BCI). However, clinical applications of these devices remain limited mostly by their inability to mitigate inflammatory reactions and support dense neuronal survival at their interfaces. Herein we report the development of microelectrodes primarily composed of extracellular matrix (ECM) proteins, which act as a bio-compatible and an electrochemical interface between the microelectrodes and physiological solution. These ECM-microelectrodes are batch fabricated using a novel combination of micro-transfer-molding and excimer laser micromachining to exhibit final dimensions comparable to those of commercial silicon-based microelectrodes. These are further integrated with a removable insertion stent which aids in intracortical implantation. Results from electrochemical models and in vivo recordings from the rat's cortex indicate that ECM encapsulations have no significant effect on the electrochemical impedance characteristics of ECM-microelectrodes at neurologically relevant frequencies. ECM-microelectrodes are found to support a dense layer of neuronal somata and neurites on the electrode surface with high neuronal viability and exhibited markedly diminished neuroinflammation and glial scarring in early chronic experiments in rats.

14.
J Biomech Eng ; 139(11)2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-28975256

RESUMEN

Bone development, maintenance, and regeneration are remarkably sensitive to mechanical cues. Consequently, mechanical stimulation has long been sought as a putative target to promote endogenous healing after fracture. Given the transient nature of bone repair, tissue-level mechanical cues evolve rapidly over time after injury and are challenging to measure noninvasively. The objective of this work was to develop and characterize an implantable strain sensor for noninvasive monitoring of axial strain across a rodent femoral defect during functional activity. Herein, we present the design, characterization, and in vivo demonstration of the device's capabilities for quantitatively interrogating physiological dynamic strains during bone regeneration. Ex vivo experimental characterization of the device showed that it possessed promising sensitivity, signal resolution, and electromechanical stability for in vivo applications. The digital telemetry minimized power consumption, enabling extended intermittent data collection. Devices were implanted in a rat 6 mm femoral segmental defect model, and after three days, data were acquired wirelessly during ambulation and synchronized to corresponding radiographic videos, validating the ability of the sensor to noninvasively measure strain in real-time. Together, these data indicate the sensor is a promising technology to quantify tissue mechanics in a specimen specific manner, facilitating more detailed investigations into the role of the mechanical environment in dynamic bone healing and remodeling processes.


Asunto(s)
Fémur , Prótesis e Implantes , Estrés Mecánico , Tecnología Inalámbrica/instrumentación , Animales , Fenómenos Biomecánicos , Ratas
15.
J Biomech Eng ; 139(2)2017 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-27987300

RESUMEN

The translation of many tissue engineering/regenerative medicine (TE/RM) therapies that demonstrate promise in vitro are delayed or abandoned due to reduced and inconsistent efficacy when implemented in more complex and clinically relevant preclinical in vivo models. Determining mechanistic reasons for impaired treatment efficacy is challenging after a regenerative therapy is implanted due to technical limitations in longitudinally measuring the progression of key environmental cues in vivo. The ability to acquire real-time measurements of environmental parameters of interest including strain, pressure, pH, temperature, oxygen tension, and specific biomarkers within the regenerative niche in situ would significantly enhance the information available to tissue engineers to monitor and evaluate mechanisms of functional healing or lack thereof. Continued advancements in material and fabrication technologies utilized by microelectromechanical systems (MEMSs) and the unique physical characteristics of passive magnetoelastic sensor platforms have created an opportunity to implant small, flexible, low-power sensors into preclinical in vivo models, and quantitatively measure environmental cues throughout healing. In this perspective article, we discuss the need for longitudinal measurements in TE/RM research, technical progress in MEMS and magnetoelastic approaches to implantable sensors, the potential application of implantable sensors to benefit preclinical TE/RM research, and the future directions of collaborative efforts at the intersection of these two important fields.


Asunto(s)
Técnicas Biosensibles/instrumentación , Regeneración Tisular Dirigida/instrumentación , Sistemas Microelectromecánicos/instrumentación , Prótesis e Implantes , Medicina Regenerativa/instrumentación , Transductores , Diseño de Equipo , Análisis de Falla de Equipo
16.
Biomed Microdevices ; 17(4): 83, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26227213

RESUMEN

Microvascularization of an engineered tissue construct is necessary to ensure the nourishment and viability of the hosted cells. Microvascular constructs can be created by seeding the luminal surfaces of microfluidic channel arrays with endothelial cells. However, in a conventional flow-based system, the uniformity of endothelialization of such an engineered microvascular network is constrained by mass transfer of the cells through high length-to-diameter (L/D) aspect ratio microchannels. Moreover, given the inherent limitations of the initial seeding process to generate a uniform cell coating, the large surface-area-to-volume ratio of microfluidic systems demands long culture periods for the formation of confluent cellular microconduits. In this report, we describe the design of polydimethylsiloxane (PDMS) and poly(glycerol sebacate) (PGS) microvascular constructs with reentrant microchannels that facilitates rapid, spatially homogeneous endothelial cell seeding of a high L/D (2 cm/35 µm; > 550:1) aspect ratio microchannels. MEMS technology was employed for the fabrication of a monolithic, elastomeric, reentrant microvascular construct. Isotropic etching and PDMS micromolding yielded a near-cylindrical microvascular channel array. A 'stretch - seed - seal' operation was implemented for uniform incorporation of endothelial cells along the entire microvascular area of the construct yielding endothelialized microvascular networks in less than 24 h. The feasibility of this endothelialization strategy and the uniformity of cellularization were established using confocal microscope imaging.


Asunto(s)
Microvasos/citología , Microvasos/metabolismo , Ingeniería de Tejidos/métodos , Decanoatos/química , Dimetilpolisiloxanos/química , Diseño de Equipo , Glicerol/análogos & derivados , Glicerol/química , Células Endoteliales de la Vena Umbilical Humana/metabolismo , Humanos , Microfluídica/métodos , Microscopía Confocal , Polímeros/química
17.
Opt Express ; 23(5): 5491-9, 2015 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-25836782

RESUMEN

We report the initial evaluation of a mid-infrared QCL-coupled silicon-on-sapphire ring resonator gas sensor. The device probes the N(2)O 2241.79 cm(-1) optical transition (R23 line) in the ν(3) vibrational band. N(2)O concentration is deduced using a non-linear least squares fit, based on coupled-mode theory, of the change in ring resonator Q due to gas absorption losses in the evanescent portion of the waveguide optical mode. These early experiments demonstrated response to 5000 ppmv N(2)O.

18.
Artículo en Inglés | MEDLINE | ID: mdl-30498620

RESUMEN

Extracellular matrix (ECM)-based implantable neural electrodes (NEs) were achieved using a microfabrication strategy on natural-substrate-based organic materials. The ECM-based design minimized the introduction of non-natural products into the brain. Further, it rendered the implants sufficiently rigid for penetration into the target brain region and allowed them subsequently to soften to match the elastic modulus of brain tissue upon exposure to physiological conditions, thereby reducing inflammatory strain fields in the tissue. Preliminary studies suggested that ECM-NEs produce a reduced inflammatory response compared with inorganic rigid and flexible approaches. In vivo intracortical recordings from the rat motor cortex illustrate one mode of use for these ECM-NEs.

19.
ACS Nano ; 8(12): 12323-37, 2014 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-25390073

RESUMEN

We investigate the size- and composition-dependent ac magnetic permeability of superparamagnetic iron oxide nanocrystals for radio frequency (RF) applications. The nanocrystals are obtained through high-temperature decomposition synthesis, and their stoichiometry is determined by Mössbauer spectroscopy. Two sets of oxides are studied: (a) as-synthesized magnetite-rich and (b) aged maghemite nanocrystals. All nanocrystalline samples are confirmed to be in the superparamagnetic state at room temperature by SQUID magnetometry. Through the one-turn inductor method, the ac magnetic properties of the nanocrystalline oxides are characterized. In magnetite-rich iron oxide nanocrystals, size-dependent magnetic permeability is not observed, while maghemite iron oxide nanocrystals show clear size dependence. The inductance, resistance, and quality factor of hand-wound inductors with a superparamagnetic composite core are measured. The superparamagnetic nanocrystals are successfully embedded into hand-wound inductors to function as inductor cores.

20.
Adv Healthc Mater ; 3(3): 367-74, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24039146

RESUMEN

The unique biomechanical properties of native tissue are governed by the organization and composition of integrated collagen and elastin networks. An approach for fabricating spatially aligned, fiber-reinforced composites with adjustable collagen fiber dimensions, layouts, and distribution within an elastin-like protein matrix yielding a biocomposite with controllable mechanical responses is reported. Microtransfer molding is employed for the fabrication of hollow and solid collagen fibers with straight or crimped fiber geometries. Collagen fibers (width: 2-50 µm, thickness: 300 nm to 3 µm) exhibit a Young's modulus of 126 ± 61 MPa and an ultimate tensile strength of 7 ± 3.2 MPa. As fiber networks within composite structures, straight fiber layouts display orthotropic responses with Young's modulus ranging from 0.95 ± 0.35 to 10.4 ± 0.5 MPa and tensile strength from 0.22 ± 0.08 to 0.87 ± 0.5 MPa with increasing fraction of collagen fibers (1-10%, v/v). In contrast, composites based on crimped fiber layouts exhibit strain-dependent stiffness with an increase in Young's modulus from 0.7 ± 0.14 MPa to 3.15 ± 0.49 MPa, at a specific transition strain. Through controlling the microstructure of engineered collagen fiber networks, a facile means is established to control macroscale mechanical responses of composite protein-based materials.


Asunto(s)
Materiales Biocompatibles/química , Colágeno/química , Matriz Extracelular/química , Animales , Fenómenos Biomecánicos , Módulo de Elasticidad , Elastina/química , Escherichia coli/metabolismo , Ratas , Ratas Sprague-Dawley , Proteínas Recombinantes/metabolismo , Resistencia a la Tracción , Ingeniería de Tejidos/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...