Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 153
Filtrar
2.
Am J Gastroenterol ; 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38976379

RESUMEN

INTRODUCTION: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is frequently used to risk-stratify pancreatic cystic lesions (PCLs). Rising PCL incidence and developments in tissue acquisition and specimen analysis necessitate updated appraisal of EUS-FNA safety, particularly the risk of postprocedure pancreatitis, the most common EUS-FNA-related adverse event. Our systematic review aims to accurately quantify the risk of EUS-FNA-related pancreatitis to best inform decisions regarding EUS-FNA's optimal role in PCL workup. METHODS: We performed systematic searches in 4 databases from inception to April 2024 for original English-language studies investigating EUS-FNA-related pancreatitis. We extracted data on demographics and EUS-FNA-related pancreatitis risk, severity, and risk factors. These were meta-analyzed through the DerSimonian Laird Method using a random-effects model. Meta-regression of pancreatitis risk was performed to delineate associations with clinical and procedural characteristics. RESULTS: Sixty-four studies comprised 8,086 patients and reported 110 EUS-FNA-related pancreatitis events. Pooled risk of EUS-FNA-related pancreatitis was 1.4% (95% confidence intervals, -0.8% to 3.5%; I2 = 0.00), which was predominantly of mild severity (67%) and uniformly nonfatal. Pancreatitis risk lacked significant association with sample size, age, sex, cyst size, needle caliber, or passes, although we noted trends toward higher risk in studies published after 2015, those using higher gauge needles (19 G vs 22 G/25 G), and those performing EUS-guided through-the-needle biopsy. DISCUSSION: We note with high certainty that pancreatitis after EUS-FNA of PCLs is infrequent and mild in severity with no mortality in the included cohort. EUS-guided through-the-needle biopsy may serve as a significant risk factor for EUS-FNA-related pancreatitis risk; however, further studies are needed to delineate other predisposing characteristics.

3.
Gastrointest Endosc ; 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38935016

RESUMEN

BACKGROUND AND AIMS: Training in interventional endoscopy is offered by nonaccredited advanced endoscopy fellowship programs (AEFPs). The number of these programs has increased dramatically with a concurrent increase in the breadth and complexity of interventional endoscopy procedures. Accreditation is governed by competency-based education, yet what constitutes a "high-quality" nonaccredited AEFP has not been defined. Using an evidence-based consensus process, we aimed to establish standards for AEFPs. METHODS: The RAND UCLA appropriateness method, a well-described modified Delphi process to develop quality indicators, was used. A task force established by the American Society for Gastrointestinal Endoscopy drafted potential quality indicators (structure, process, and outcome) in 6 categories: activity preceding training; structure of AEFPs; training in ERCP, EUS, and EMR; and luminal stent placement. Three rounds of iterative feedback from 20 experts were conducted. Round 0 involved discussion of project details. In round 1, experts independently ranked proposed quality indicators on a 9-point interval scale ranging from highly inappropriate (1) to highly appropriate (9). Next, proposed quality indicators were discussed and reworded in a group meeting followed by round 2, in which experts independently reranked proposed quality indicators and provided benchmarks (when applicable). The median score for each quality indicator was calculated. Mean absolute deviation from the median was calculated, and appropriateness of potential quality indicators was assessed using the BIOMED concerted action on appropriateness definition, P value method, and interpercentile range adjusted for symmetry definition. A quality indicator was deemed appropriate if the median score was ≥7 and met criteria for appropriateness using all 3 defined statistical methods. RESULTS: Of 89 proposed quality indicators, 37 statements met criteria as appropriate for a quality indicator (activity preceding training, 2; structure of AEFPs, 10; training in ERCP, 7; training in EUS, 8; training in EMR, 7; luminal stent placement, 3). Minimum thresholds were defined for 19 relevant quality indicators for number of trainers, procedures during fellowship, and procedures before assessment of competence. Among the final appropriate quality indicators were that all trainees should undergo qualitative and quantitative competence assessments using validated tools at least quarterly with documented feedback throughout the training period and that trainees should track outcomes and relevant quality metrics for specific procedures. CONCLUSIONS: This consensus process using validated methodology established standards for an AEFP in an effort to ensure adequate training in the most commonly taught interventional endoscopic procedures (ERCP, EUS, EMR, and luminal stent placement) during fellowship. An important component of an AEFP is the use of competency-based assessments that are compliant with the Accreditation Council for Graduate Medical Education's Next Accreditation System, with the goal of ensuring that trainees achieve specific milestones in their progression to achieving cognitive and technical competency.

4.
Ann Intern Med ; 177(7): 919-928, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38768453

RESUMEN

BACKGROUND: Computer-aided diagnosis (CADx) allows prediction of polyp histology during colonoscopy, which may reduce unnecessary removal of nonneoplastic polyps. However, the potential benefits and harms of CADx are still unclear. PURPOSE: To quantify the benefit and harm of using CADx in colonoscopy for the optical diagnosis of small (≤5-mm) rectosigmoid polyps. DATA SOURCES: Medline, Embase, and Scopus were searched for articles published before 22 December 2023. STUDY SELECTION: Histologically verified diagnostic accuracy studies that evaluated the real-time performance of physicians in predicting neoplastic change of small rectosigmoid polyps without or with CADx assistance during colonoscopy. DATA EXTRACTION: The clinical benefit and harm were estimated on the basis of accuracy values of the endoscopist before and after CADx assistance. The certainty of evidence was assessed using the GRADE (Grading of Recommendations Assessment, Development and Evaluation) framework. The outcome measure for benefit was the proportion of polyps predicted to be nonneoplastic that would avoid removal with the use of CADx. The outcome measure for harm was the proportion of neoplastic polyps that would be not resected and left in situ due to an incorrect diagnosis with the use of CADx. Histology served as the reference standard for both outcomes. DATA SYNTHESIS: Ten studies, including 3620 patients with 4103 small rectosigmoid polyps, were analyzed. The studies that assessed the performance of CADx alone (9 studies; 3237 polyps) showed a sensitivity of 87.3% (95% CI, 79.2% to 92.5%) and specificity of 88.9% (CI, 81.7% to 93.5%) in predicting neoplastic change. In the studies that compared histology prediction performance before versus after CADx assistance (4 studies; 2503 polyps), there was no difference in the proportion of polyps predicted to be nonneoplastic that would avoid removal (55.4% vs. 58.4%; risk ratio [RR], 1.06 [CI, 0.96 to 1.17]; moderate-certainty evidence) or in the proportion of neoplastic polyps that would be erroneously left in situ (8.2% vs. 7.5%; RR, 0.95 [CI, 0.69 to 1.33]; moderate-certainty evidence). LIMITATION: The application of optical diagnosis was only simulated, potentially altering the decision-making process of the operator. CONCLUSION: Computer-aided diagnosis provided no incremental benefit or harm in the management of small rectosigmoid polyps during colonoscopy. PRIMARY FUNDING SOURCE: European Commission. (PROSPERO: CRD42023402197).


Asunto(s)
Pólipos del Colon , Colonoscopía , Diagnóstico por Computador , Humanos , Pólipos del Colon/patología , Pólipos del Colon/diagnóstico por imagen , Neoplasias Colorrectales/patología , Neoplasias Colorrectales/diagnóstico
7.
Gastrointest Endosc ; 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38639679

RESUMEN

BACKGROUND AND AIMS: The American Society for Gastrointestinal Endoscopy (ASGE) AI Task Force along with experts in endoscopy, technology space, regulatory authorities, and other medical subspecialties initiated a consensus process that analyzed the current literature, highlighted potential areas, and outlined the necessary research in artificial intelligence (AI) to allow a clearer understanding of AI as it pertains to endoscopy currently. METHODS: A modified Delphi process was used to develop these consensus statements. RESULTS: Statement 1: Current advances in AI allow for the development of AI-based algorithms that can be applied to endoscopy to augment endoscopist performance in detection and characterization of endoscopic lesions. Statement 2: Computer vision-based algorithms provide opportunities to redefine quality metrics in endoscopy using AI, which can be standardized and can reduce subjectivity in reporting quality metrics. Natural language processing-based algorithms can help with the data abstraction needed for reporting current quality metrics in GI endoscopy effortlessly. Statement 3: AI technologies can support smart endoscopy suites, which may help optimize workflows in the endoscopy suite, including automated documentation. Statement 4: Using AI and machine learning helps in predictive modeling, diagnosis, and prognostication. High-quality data with multidimensionality are needed for risk prediction, prognostication of specific clinical conditions, and their outcomes when using machine learning methods. Statement 5: Big data and cloud-based tools can help advance clinical research in gastroenterology. Multimodal data are key to understanding the maximal extent of the disease state and unlocking treatment options. Statement 6: Understanding how to evaluate AI algorithms in the gastroenterology literature and clinical trials is important for gastroenterologists, trainees, and researchers, and hence education efforts by GI societies are needed. Statement 7: Several challenges regarding integrating AI solutions into the clinical practice of endoscopy exist, including understanding the role of human-AI interaction. Transparency, interpretability, and explainability of AI algorithms play a key role in their clinical adoption in GI endoscopy. Developing appropriate AI governance, data procurement, and tools needed for the AI lifecycle are critical for the successful implementation of AI into clinical practice. Statement 8: For payment of AI in endoscopy, a thorough evaluation of the potential value proposition for AI systems may help guide purchasing decisions in endoscopy. Reliable cost-effectiveness studies to guide reimbursement are needed. Statement 9: Relevant clinical outcomes and performance metrics for AI in gastroenterology are currently not well defined. To improve the quality and interpretability of research in the field, steps need to be taken to define these evidence standards. Statement 10: A balanced view of AI technologies and active collaboration between the medical technology industry, computer scientists, gastroenterologists, and researchers are critical for the meaningful advancement of AI in gastroenterology. CONCLUSIONS: The consensus process led by the ASGE AI Task Force and experts from various disciplines has shed light on the potential of AI in endoscopy and gastroenterology. AI-based algorithms have shown promise in augmenting endoscopist performance, redefining quality metrics, optimizing workflows, and aiding in predictive modeling and diagnosis. However, challenges remain in evaluating AI algorithms, ensuring transparency and interpretability, addressing governance and data procurement, determining payment models, defining relevant clinical outcomes, and fostering collaboration between stakeholders. Addressing these challenges while maintaining a balanced perspective is crucial for the meaningful advancement of AI in gastroenterology.

8.
VideoGIE ; 9(3): 119-122, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38482469

RESUMEN

Video 1The mass was identified at the upper- to mid-esophagus, 25 cm from the central incisors. No varices were seen on further examination of the esophagus. A 4-mm injector force needle was used to create a large submucosal injection using BlueBoost lifting agent proximal to the mass. A longitudinal mucosal incision was then made using the hybrid T-type electrocautery knife, 20 cm from the central incisors.The cutting current was the preset Endocut Q mode, and the coagulation setting was spray coag mode, effect 2 and 40 W.Next, tunnel creation by submucosal dissection was performed with a focus on keeping the submucosal space as clean as possible. Carbon dioxide was used for insufflation to prevent pneumoperitoneum.A smooth-surfaced oval mass was identified originating from the muscularis propria layer. Dissection was extended 2 cm distally beyond the mass. Next, resection of the mass was performed. First, the mucosal surface of the mass was dissected. Dissection began at the distal portion, proceeded to the left and right lateral borders, and then continued toward the proximal portion. The mass was dissected away from the muscularis propria.We focused on freeing the mass, ensuring this esophageal mass was intact throughout dissection. The attached bands of muscularis propria at the distal portion were carefully resected completely.Water irrigation was used at this time to ensure better visualization for resection. The remaining attached bands of muscularis propria were resected, ensuring complete en bloc resection. Afterward, the mass was suctioned into the cap and carefully retrieved as shown, and then sent to pathology for processing.The entire defect bed was inspected post-resection, and no perforation or bleeding was identified.The mucosal defect was completely closed with through-the-scope hemostatic clips in a longitudinal fashion beginning with approximation of the defect at the distal portion.

9.
Dig Dis Sci ; 69(5): 1880-1888, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38555329

RESUMEN

BACKGROUND AND AIMS: Endoscopic retrograde cholangiopancreatography (ERCP) is the standard of care for the management of choledocholithiasis but carries risk of complications which may result in significant morbidity and mortality. While currently available guidelines endorse the use of ERCP for the management of symptomatic common bile duct stones, the need for ERCP in incidentally found asymptomatic choledocholithiasis is more controversial, and practice varies on a geographic and institutional level. This systematic review and meta-analysis is conducted to compare post-ERCP adverse events between asymptomatic and symptomatic choledocholithiasis patients. METHODS: We searched PubMed/Embase/Web of Science databases to include all studies comparing post-ERCP outcomes between asymptomatic and symptomatic choledocholithiasis patients. The primary outcome was post-ERCP pancreatitis (PEP), while secondary outcomes included post-ERCP cholangitis, bleeding, and perforation. We calculated pooled risk ratios (RR) and 95% confidence intervals (CIs) using the Mantel-Haenszel method within a random-effect model. RESULTS: Our analysis included six observational studies, totaling 2,178 choledocholithiasis patients (392 asymptomatic and 1786 symptomatic); 53% were female. Asymptomatic patients exhibited a higher risk of PEP compared with symptomatic patients (11.7% versus 4.8%; RR 2.59, 95% CI 1.56-4.31, p ≤ 0.001). No significant difference was observed in post-ERCP cholangitis, bleeding, or perforation rates between the two groups. CONCLUSIONS: Asymptomatic patients with choledocholithiasis appear to have a higher risk of PEP than symptomatic patients, while the risk of other post-ERCP adverse events is similar between the two groups. Interventional endoscopists should thoroughly discuss potential adverse events (particularly PEP) with asymptomatic patients before performing ERCP and utilize PEP-prevention measures more liberally in this subgroup of patients.


Asunto(s)
Colangiopancreatografia Retrógrada Endoscópica , Coledocolitiasis , Pancreatitis , Humanos , Coledocolitiasis/cirugía , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Pancreatitis/etiología , Pancreatitis/epidemiología , Enfermedades Asintomáticas , Colangitis/etiología , Colangitis/epidemiología , Factores de Riesgo , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/diagnóstico
10.
ACG Case Rep J ; 11(3): e01297, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38469432

RESUMEN

Endoscopic ultrasound (EUS)-guided liver biopsy is gaining popularity for liver parenchymal sampling due to its detailed visualization of liver anatomy, precision in sampling, and the ability to combine liver biopsy with other endoscopic goals. In this study, we present a case involving an anatomically complex, immunocompromised patient who underwent EUS-guided liver biopsy. While the samples were sufficient and progressed the management of her autoimmune hepatitis, her course was complicated by a multiloculated liver abscess. EUS liver biopsy has an excellent safety profile, but a small risk of infection remains, especially in immunocompromised patients or those with preexisting biliary obstruction.

11.
Endosc Int Open ; 12(2): E324-E331, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38420150

RESUMEN

Background and study aims The Bethesda ERCP Skill Assessment Tool (BESAT) is a video-based assessment tool of technical endoscopic retrograde cholangiopancreatography (ERCP) skill with previously established validity evidence. We aimed to assess the discriminative validity of the BESAT in differentiating ERCP skill levels. Methods Twelve experienced ERCP practitioners from tertiary academic centers were asked to blindly rate 43 ERCP videos using the BESAT. ERCP videos consisted of native biliary cannulation and sphincterotomy and were recorded from 10 unique endoscopists of various ERCP experience (from advanced endoscopy fellow to > 10 years of ERCP experience). Inter-rater reliability, discriminative validity, and internal structure validity were subsequently assessed. Results The BESAT was found to reliably differentiate between endoscopists of varying levels of ERCP experience with experienced ERCPists scoring higher than novice ERCPists in 11 of 13 (85%) instrument items. Inter-rater reliability for BESAT items ranged from good to excellent (intraclass correlation range: 0.86 to 0.93). Internal structure validity was assessed with item-total correlations ranging from 0.53 to 0.83. Conclusions Study findings demonstrate that the BESAT, a video-based ERCP skill assessment tool, has high inter-rater reliability and has discriminative validity in differentiating novice from expert ERCP skill. Further investigations are needed to determine the role of video-based assessment in improving trainee learning curves and patient outcomes.

12.
Gastrointest Endosc ; 99(4): 483-489.e2, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38416097

RESUMEN

BACKGROUND AND AIMS: The use of artificial intelligence (AI) has transformative implications to the practice of gastroenterology and endoscopy. The aims of this study were to understand the perceptions of the gastroenterology community toward AI and to identify potential barriers for adoption. METHODS: A 16-question online survey exploring perceptions on the current and future implications of AI to the field of gastroenterology was developed by the American Society for Gastrointestinal Endoscopy AI Task Force and distributed to national and international society members. Participant demographic information including age, sex, experience level, and practice setting was collected. Descriptive statistics were used to summarize survey findings, and a Pearson χ2 analysis was performed to determine the association between participant demographic information and perceptions of AI. RESULTS: Of 10,162 invited gastroenterologists, 374 completed the survey. The mean age of participants was 46 years (standard deviation, 12), and 299 participants (80.0%) were men. One hundred seventy-nine participants (47.9%) had >10 years of practice experience, with nearly half working in the community setting. Only 25 participants (6.7%) reported the current use of AI in their clinical practice. Most participants (95.5%) believed that AI solutions will have a positive impact in their practice. One hundred seventy-six participants (47.1%) believed that AI will make clinical duties more technical but will also ease the burden of the electronic medical record (54.0%). The top 3 areas where AI was predicted to be most influential were endoscopic lesion detection (65.3%), endoscopic lesion characterization (65.8%), and quality metrics (32.6%). Participants voiced a desire for education on topics such as the clinical use of AI applications (64.4%), the advantages and limitations of AI applications (57.0%), and the technical methodology of AI (44.7%). Most participants (42.8%) expressed that the cost of AI implementation should be covered by their hospital. Demographic characteristics significantly associated with this perception included participants' years in practice and practice setting. CONCLUSIONS: Gastroenterologists have an overall positive perception regarding the use of AI in clinical practice but voiced concerns regarding its technical aspects and coverage of costs associated with implementation. Further education on the clinical use of AI applications with understanding of the advantages and limitations appears to be valuable in promoting adoption.


Asunto(s)
Gastroenterólogos , Gastroenterología , Médicos , Masculino , Humanos , Persona de Mediana Edad , Femenino , Inteligencia Artificial , Benchmarking
13.
J Clin Gastroenterol ; 2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-38277501

RESUMEN

BACKGROUND AND AIMS: The application of endoscopic suturing has revolutionized defect closures. Conventional over-the-scope suturing necessitates removal of the scope, placement of the device, and reinsertion. A single channel, single sequence, through-the-scope suturing device has been developed to improve this process. This study aims to describe the efficacy, feasibility, and safety of a through-the-scope suturing device for gastrointestinal defect closure. METHODS: This was a retrospective multicenter study involving 9 centers of consecutive adult patients who underwent suturing using the X-Tack Endoscopic HeliX Tacking System (Apollo Endosurgery). The primary outcomes were technical success and long-term clinical success. Secondary outcomes included adverse events, recurrence, and reintervention rates. RESULTS: In all, 56 patients (mean age 53.8, 33 women) were included. Suturing indications included fistula repair (n=22), leak repair (n=7), polypectomy defect closure (n=12), peroral endoscopic myotomy (POEM) site closure (n=7), perforation repair (n=6), and ulcers (n=2). Patients were followed at a mean duration of 74 days. Overall technical and long-term clinical success rates were 92.9% and 75%, respectively. Both technical and clinical success rates were 100% for polypectomies, POEM-site closures, and ulcers. Success rates were lower for the repair of fistulas (95.5% technical, 54.5% clinical), leaks (57.1%, 28.6%), and perforations (100%, 66.7%). No immediate adverse events were noted. CONCLUSION: This novel, through-the-scope endoscopic suturing system, is a safe and feasible method to repair defects that are ≤3 cm. The efficacy of this device may be better suited for superficial defects as opposed to full-thickness defects. Larger defects will need more sutures and probably a double closure technique to provide a reinforcement layer.

15.
ACG Case Rep J ; 10(12): e01229, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38130477

RESUMEN

Pyloric gland adenomas (PGAs) are rare neoplasms found not only in the gastrointestinal tract but also in other extragastrointestinal organs. They have potential for malignant conversion, and early detection and removal is imperative to prevent invasive disease. PGAs prove difficult in management and surveillance given their rarity. However, increasing familiarity with histological appearance and use of advanced tools such as echoendosonography can bring greater understanding of their clinical history. We describe a unique case of a PGA detected within a hiatal hernia sac characterized with echoendosonography and highlight the need to develop surveillance protocols for these types of lesions.

16.
ACG Case Rep J ; 10(12): e01210, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38130479

RESUMEN

Kaposi sarcoma (KS) is a pathological endothelial growth associated with human herpes virus-8 which primarily affects the skin. In HIV-negative men who have sex with men, the clinical presentation of KS resembles the classic form limited to cutaneous or multifocal disease. In this report, we present a unique case of a healthy 61-year-old man who has sex with men with an isolated gastrointestinal KS who does not meet criteria for any of the typical KS clinical variants. Proper follow-up and regular HIV screenings are needed to evaluate the potential progression course of the disease in these patients.

17.
Gastroenterology ; 165(6): 1568-1573, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37855759

RESUMEN

DESCRIPTION: The purpose of this American Gastroenterological Association (AGA) Institute Clinical Practice Update (CPU) is to review the available evidence and provide expert commentary on the current landscape of artificial intelligence in the evaluation and management of colorectal polyps. METHODS: This CPU was commissioned and approved by the AGA Institute Clinical Practice Updates Committee (CPUC) and the AGA Governing Board to provide timely guidance on a topic of high clinical importance to the AGA membership and underwent internal peer review by the CPUC and external peer review through standard procedures of Gastroenterology. This Expert Commentary incorporates important as well as recently published studies in this field, and it reflects the experiences of the authors who are experienced endoscopists with expertise in the field of artificial intelligence and colorectal polyps.


Asunto(s)
Pólipos del Colon , Humanos , Pólipos del Colon/diagnóstico , Pólipos del Colon/terapia , Inteligencia Artificial , Academias e Institutos , Relevancia Clínica , Colon
18.
VideoGIE ; 8(9): 340-341, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37719948

RESUMEN

Video 1Endoscopic treatment of a Bouveret syndrome showing and describing the techniques and procedures involved.

19.
VideoGIE ; 8(8): 298-300, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37575135

RESUMEN

Video 1Enhanced suction for removal of esophageal food impaction.

20.
VideoGIE ; 8(8): 304-306, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37575141

RESUMEN

Video 1Natural orifice transendoscopic surgery as a rescue for a dislodged lumen-apposing metal stent after EUS-directed transgastric ERCP.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA