Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Clin J Am Soc Nephrol ; 17(6): 872-876, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35551070
3.
Dalton Trans ; 49(29): 10185-10202, 2020 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-32666958

RESUMEN

A group of new boron complexes [BPh2{κ2N,N'-NC4H3-2-C(H)[double bond, length as m-dash]N-C6H4X}] (X = 4-Cl 4c, 4-Br 4d, 4-I 4e, 3-Br 4f, 2-Br 4g, 2-I 4h) containing different halogens as substituents in the N-aryl ring have been synthesized and characterized in terms of their molecular properties. Their photophysical characteristics have been thoroughly studied in order to understand whether these complexes exhibit an internal heavy-atom effect. Phosphorescence emission was found for some of the synthesized halogen-substituted boron molecules, particularly for 4g and 4h. DFT and TDDFT calculations showed that the lower energy absorption band resulted from the HOMO to LUMO (π-π*) transition, except for 2-I 4h, where the HOMO-1 to LUMO transition was also involved. The strong participation of iodine orbitals in HOMO-1 is reflected in the calculated absorption spectra of the iodine derivatives, especially 2-I 4h, when spin-orbit coupling (SOC) was included. Organic light-emitting diodes (OLEDs) based on these complexes, in the neat form or dispersed in a matrix, were also fabricated and tested. The devices based on films prepared by thermal vacuum deposition showed the best performance. When neat complexes were used, a maximum luminance (Lmax) of 1812 cd m-2 was obtained, with a maximum external quantum efficiency (EQEmax) of 0.15%. An EQEmax of ca. 1% along with a maximum luminance of 494 cd m-2 were obtained for a device fabricated by co-deposition of the boron complex and a host compound (1,3-bis(N-carbazolyl)benzene, mCP).

4.
Hemodial Int ; 23(1): 50-57, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30367698

RESUMEN

INTRODUCTION: The aim of this study is to compare molecule removal and albumin leakage in postdilution online hemodiafiltration with different high-flux dialyzers. METHODS: We studied seven high-flux dialyzers (Polyflux 210H®, Evodial 2.2®, FxCordiax1000®, Elisio21H®, TS-2.1SL®, XevontaHi20®, VitaPES 210-HF®) in 6 patients. The reduction ratio (RR) of small- and middle-sized molecules was calculated. Dialysate samples were collected to estimate the albumin leakage. FINDINGS: Global differences between dialyzers were observed in the RR of ß2 microglobulin (P =0.003) and prolactin (P =0.013). The mean loss of albumin in the dialysate per session varied between 114 ± 67 mg (with Evodial 2.2) and 2621 ± 1363 mg per session (with XevontaHi20). We found global differences between dialyzers in total albumin loss (P = 0.05). DISCUSSION: We demonstrated that the performance of high-flux dialyzers was different among the types and that not all high-flux dialyzers should be considered equal.


Asunto(s)
Soluciones para Diálisis/uso terapéutico , Hemodiafiltración/métodos , Diálisis Renal/métodos , Adulto , Estudios Cruzados , Soluciones para Diálisis/farmacología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
5.
Nefrología (Madrid) ; 38(6): 616-621, nov.-dic. 2018. graf, tab
Artículo en Español | IBECS | ID: ibc-178391

RESUMEN

ANTECEDENTES Y OBJETIVO: El abordaje multidisciplinar y el uso de ecografía doppler (ED) en la creación y vigilancia del acceso vascular (AV) puede mejorar la prevalencia y permeabilidad de las fístulas arteriovenosas (FAV) para hemodiálisis. El objetivo de este estudio es analizar el impacto de una nueva consulta multidisciplinar (CMD) de AV con ED de rutina. MATERIAL Y MÉTODOS: Evaluamos los resultados de la consulta de AV en 2014 (pre-CMD) y 2015 (CMD), antes y después de la implantación de un equipo multidisciplinar (cirujano vascular/nefrólogo) con ED de rutina en mapeo prequirúrgico y FAV prevalente. RESULTADOS: Se evaluaron 345 pacientes en 2014 (pre-CMD) y 364 pacientes en 2015 (CMD). En ambos periodos se realizó un número similar de cirugías, 172 vs. 198, p = 0,289, con tendencia a aumentar las cirugías preventivas de reparación de FAV en el periodo CMD, 17 vs. 29 (p = 0,098). En FAV de nueva creación (155 vs. 169), disminuyó la tasa de fallo primario en el periodo CMD, 26,4 vs. 15,3%, p = 0,015 y aumentó de forma no significativa la realización de FAV radiocefálicas distales, 25,8 vs. 33,2% (n = 40 vs. 56), p = 0,159. También aumentó la concordancia entre la indicación quirúrgica en la consulta y la cirugía realizada (81,3 vs. 93,5%, p = 0,001). En el periodo CMD se solicitaron menos exploraciones radiológicas desde la consulta, 78 vs. 35 (p < 0,001), con una reducción del gasto sanitario (81.716€ vs. 59.445€). CONCLUSIONES: El manejo multidisciplinar y la utilización del ED de rutina permiten mejorar los resultados de AV, con disminución de la tasa de fallo primario de FAV, más opciones de FAV distal nativa, mejor manejo de la FAV prevalente disfuncionante y menor coste en exploraciones radiológicas


BACKGROUND: A multidisciplinary approach and Doppler ultrasound (DU) assessment for the creation and maintenance of arteriovenous fistulas (AVF) for haemodialysis can improve prevalence and patency. The aim of this study was to analyse the impact of a new multidisciplinary vascular access (VA) clinic with routine DU. MATERIAL AND METHODS: We analysed the VA clinic results from 2014 and 2015, before and after the implementation of a multidisciplinary team protocol (vascular surgeon/nephrologist) with routine DU in preoperative mapping and prevalent AVF. RESULTS: We analysed 345 and 364 patients from 2014 and 2015 respectively. The number of surgical interventions was similar in both periods (p = .289), with a trend towards an increase in preventive surgical repair of AVF in 2015 (17 vs. 29, p = .098). 155 vs. 169 new AVF were performed in 2014 and 2015, with a significantly lower primary failure rate in 2015 (26.4 vs. 15.3%, p = .015), and a non-significant increase in radiocephalic AVF, 25.8 vs. 33.2% (n = 40 vs. 56), p = .159. The concordance between the indication at the clinic and the surgery performed also increased (81.3 vs. 93.5%, p = .001). Throughout 2015 fewer complementary imaging test were requested from the clinic (78 vs. 35, p < .001), with a corresponding reduction in costs (€87,716 vs. €59,445). CONCLUSIONS: Multidisciplinary approach with routine DU can improve VA results, with a decrease in primary failure rate, higher likelihood of radiocephalic AVF, better management of dis-functioning AVF and lower radiological test costs


Asunto(s)
Humanos , Ultrasonografía Doppler/métodos , Dispositivos de Acceso Vascular , Grupo de Atención al Paciente , Fístula Arteriovenosa/prevención & control , Diálisis Renal , Estudios Retrospectivos , Estudio Observacional
6.
Nefrologia (Engl Ed) ; 38(6): 616-621, 2018.
Artículo en Inglés, Español | MEDLINE | ID: mdl-29903522

RESUMEN

BACKGROUND: A multidisciplinary approach and Doppler ultrasound (DU) assessment for the creation and maintenance of arteriovenous fistulas (AVF) for haemodialysis can improve prevalence and patency. The aim of this study was to analyse the impact of a new multidisciplinary vascular access (VA) clinic with routine DU. MATERIAL AND METHODS: We analysed the VA clinic results from 2014 and 2015, before and after the implementation of a multidisciplinary team protocol (vascular surgeon/nephrologist) with routine DU in preoperative mapping and prevalent AVF. RESULTS: We analysed 345 and 364 patients from 2014 and 2015 respectively. The number of surgical interventions was similar in both periods (p=.289), with a trend towards an increase in preventive surgical repair of AVF in 2015 (17 vs. 29, p=.098). 155 vs. 169 new AVF were performed in 2014 and 2015, with a significantly lower primary failure rate in 2015 (26.4 vs. 15.3%, p=.015), and a non-significant increase in radiocephalic AVF, 25.8 vs. 33.2% (n=40 vs. 56), p=.159. The concordance between the indication at the clinic and the surgery performed also increased (81.3 vs. 93.5%, p=.001). Throughout 2015 fewer complementary imaging test were requested from the clinic (78 vs. 35, p <.001), with a corresponding reduction in costs (€87,716 vs. €59,445). CONCLUSIONS: Multidisciplinary approach with routine DU can improve VA results, with a decrease in primary failure rate, higher likelihood of radiocephalic AVF, better management of dis-functioning AVF and lower radiological test costs.


Asunto(s)
Derivación Arteriovenosa Quirúrgica , Vasos Sanguíneos/diagnóstico por imagen , Diálisis Renal/métodos , Ultrasonografía Doppler , Humanos , Grupo de Atención al Paciente , Estudios Retrospectivos
9.
J Healthc Manag ; 61(6): 447-448, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28319963
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...