Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Med Sci Educ ; 32(4): 773-777, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36035531

RESUMEN

With increasingly complicated patients and faster throughput, time for thorough critical thinking and thoughtful clinical documentation is limited, especially in the training environment. Advocating for the value of clinical documentation as a robust opportunity for critical thinking, we describe the implementation and evaluation of a clinical reasoning and documentation curriculum for internal medicine residents. Our curriculum employed facilitated discussion, practical application, and a resident-as-teacher model. Resident surveys showed improved perceptions of the clinical and educational value of clinical documentation. Residents reported increased feedback to interns about their documentation and more appreciation of documentation as a venue for critical thinking. Supplementary Information: The online version contains supplementary material available at 10.1007/s40670-022-01570-5.

2.
MedEdPORTAL ; 18: 11209, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35047666

RESUMEN

INTRODUCTION: Increasingly, use of the electronic health record (EHR) is interwoven into even the most basic patient care tasks. Accordingly, learning how to utilize the EHR during patient encounters is important for medical students as they develop their clinical skills. Existing EHR curricula have focused primarily on doctor-patient relationship skills. We developed a session for our preclinical students on EHR-related doctor-patient relationship skills as well as on using the EHR to verify data and focus one's history taking. METHODS: We developed student notes, three training videos, four standardized patient (SP) cases, and a simplified, simulated EHR based on these cases. Students reviewed the notes and videos prior to class. During class, students practiced EHR-related communication and data-collection strategies by interviewing an SP while interacting with the simulated EHR. Following each encounter, students received feedback from a small group of peers and faculty. RESULTS: Two-hundred eighty-nine second-year medical students participated this session in 2019 and 2020, and 27 (19%, 2019) and 40 (28%, 2020) students, respectively, completed the postsession evaluation. Most respondents rated the SP activity as extremely or quite effective for practicing doctor-patient relationship strategies while interacting with the EHR (89%, 2019; 83%, 2020) and for practicing verification of EHR data during a patient encounter (81%, 2019; 86%, 2020). DISCUSSION: This training session was effective for introducing preclinical medical students to fundamental concepts and skills related to incorporating the EHR into patient encounters and offers a low-cost approach to teaching early medical students these important skills.


Asunto(s)
Estudiantes de Medicina , Competencia Clínica , Curriculum , Registros Electrónicos de Salud , Humanos , Relaciones Médico-Paciente
3.
J Am Geriatr Soc ; 69(5): 1357-1362, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33469933

RESUMEN

BACKGROUND: Frailty is associated with numerous post-operative adverse outcomes in older adults. Current pre-operative frailty screening tools require additional data collection or objective assessments, adding expense and limiting large-scale implementation. OBJECTIVE: To evaluate the association of an automated measure of frailty integrated within the Electronic Health Record (EHR) with post-operative outcomes for nonemergency surgeries. DESIGN: Retrospective cohort study. SETTING: Academic Medical Center. PARTICIPANTS: Patients 65 years or older that underwent nonemergency surgery with an inpatient stay 24 hours or more between October 8th, 2017 and June 1st, 2019. EXPOSURES: Frailty as measured by a 54-item electronic frailty index (eFI). OUTCOMES AND MEASUREMENTS: Inpatient length of stay, requirements for post-acute care, 30-day readmission, and 6-month all-cause mortality. RESULTS: Of 4,831 unique patients (2,281 females (47.3%); mean (SD) age, 73.2 (5.9) years), 4,143 (85.7%) had sufficient EHR data to calculate the eFI, with 15.1% categorized as frail (eFI > 0.21) and 50.9% pre-frail (0.10 < eFI ≤ 0.21). For all outcomes, there was a generally a gradation of risk with higher eFI scores. For example, adjusting for age, sex, race/ethnicity, and American Society of Anesthesiologists class, and accounting for variability by service line, patients identified as frail based on the eFI, compared to fit patients, had greater needs for post-acute care (odds ratio (OR) = 1.68; 95% confidence interval (CI) = 1.36-2.08), higher rates of 30-day readmission (hazard ratio (HR) = 2.46; 95%CI = 1.72-3.52) and higher all-cause mortality (HR = 2.86; 95%CI = 1.84-4.44) over 6 months' follow-up. CONCLUSIONS: The eFI, an automated digital marker for frailty integrated within the EHR, can facilitate pre-operative frailty screening at scale.


Asunto(s)
Registros Electrónicos de Salud/estadística & datos numéricos , Anciano Frágil/estadística & datos numéricos , Fragilidad/diagnóstico , Indicadores de Salud , Medición de Riesgo/métodos , Anciano , Anciano de 80 o más Años , Femenino , Fragilidad/mortalidad , Evaluación Geriátrica/estadística & datos numéricos , Hospitalización/estadística & datos numéricos , Humanos , Masculino , Tamizaje Masivo/métodos , Tamizaje Masivo/estadística & datos numéricos , Aceptación de la Atención de Salud/estadística & datos numéricos , Readmisión del Paciente/estadística & datos numéricos , Periodo Posoperatorio , Periodo Preoperatorio , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Factores de Riesgo , Integración de Sistemas
4.
J Surg Res ; 140(1): 6-11, 2007 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-17481980

RESUMEN

BACKGROUND: Effective laparoscopic ventral herniorrhaphy usually mandates the use of an intraperitoneal prosthetic. Visceral adhesions and changes in textile characteristics of prosthetics may complicate repairs, especially long-term. The aim of this study was to compare the adhesion formation, tissue ingrowth, and textile characteristics one year after intra-abdominal placement of the commonly used prosthetic meshes. MATERIALS AND METHODS: Forty (4 x 4 cm) meshes were sutured using absorbable suture to an intact peritoneum in 20 New Zealand white rabbits. The study groups included: polypropylene (PP) [Marlex; C.R. Bard Inc, Cranston, NJ], expanded polytetrafluoroethylene (ePTFE) [DualMesh; WL Gore, Flagstaff, AZ], ePTFE and PP (ePTFE/PP) [Composix, C.R. Bard Inc], reduced weight PP and oxidized regenerated cellulose (rPP/C) [Proceed; Ethicon, Inc, Somerville, NJ]. The meshes were explanted after one year. Adhesions were scored as a percentage of explanted biomaterials' affected surface area. Prosthetic shrinkage was calculated. The strength of incorporation and mesh compliance were evaluated using differential variable reluctance transducers. Mesh ingrowth was measured as the load necessary to distract the mesh/tissue complex. Mesh compliance was calculated as the change in linear displacement of the sensors due to applied load. The groups were compared using Student's t-test and Fisher's exact test. RESULTS: ePTFE had significantly less adhesions (0%) than both ePTFE/PP (40%) and PP (80%) groups (P < 0.001). The mean area of adhesions for the rPP/C (10%) and the ePTFE/PP (14%) groups was less than that for the PP group (40%) (P = 0.02). Prosthetic shrinkage was greatest in the ePTFE (32%) group than in any other group (P = 0.001). There were no differences in mesh incorporation between the groups. At explantation, mesh compliance in the ePTFE group was superior to other meshes (P < 0.0001). The rPP/C mesh induced the smallest change in the compliance of the tissue adjacent to the mesh (P = 0.0001). CONCLUSIONS: Prosthetic materials demonstrate a wide variety of characteristics. Although exposed PP formed the most adhesions, up to 40% of the other PP-based meshes formed adhesions despite protective barriers. The ePTFE mesh did not induce adhesions and was the most compliant, however, this prosthetic's contraction was greatest. Reduced weight polypropylene (rPP/C) mesh induced the smallest change in the adjacent tissue pliability/compliance. Understanding of the long-term effects of various prosthetic materials is important to ensure an adequate hernia repair while minimizing postoperative morbidity and patient discomfort.


Asunto(s)
Hernia Abdominal/cirugía , Ensayo de Materiales , Prótesis e Implantes/efectos adversos , Mallas Quirúrgicas/efectos adversos , Adherencias Tisulares/prevención & control , Abdomen , Animales , Fenómenos Biomecánicos , Laparoscopía , Politetrafluoroetileno/efectos adversos , Complicaciones Posoperatorias/prevención & control , Falla de Prótesis , Conejos
5.
Surg Endosc ; 21(7): 1170-4, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17285375

RESUMEN

BACKGROUND: Placement of an intraperitoneal prosthetic is required for laparoscopic ventral hernia repair. The biocompatibility of these prosthetics determines the host's inflammatory response, scar plate formation, tissue ingrowth, and subsequent mesh performance, including prosthetic compliance and prevention of hernia recurrence. We evaluated the host response to intraperitoneal placement of several prosthetics currently used in clinical practice. METHODS: A 4-cm x 4-cm piece of mesh was implanted on intact peritoneum in New Zealand white rabbits. The mesh types included expanded polytetrafluoroethylene (ePTFE) (DualMesh), ePTFE and polypropylene (Composix, heavyweight polypropylene), polypropylene and oxidized regenerated cellulose (Proceed, midweight polypropylene), and polypropylene (Marlex, heavyweight polypropylene). At four months, standard hematoxylin and eosin and Milligan's trichrome stains of the mesh-tissue interaction were analyzed by three observers blinded to the mesh types. Each specimen was evaluated for scar plate formation, inflammatory response, and tissue ingrowth. Each of these three categories was graded on a standard scale of 1-4 (1 = normal tissue and 4 = severe inflammatory response). The scores were analyzed using Wilcoxon rank sum test with p < 0.05 as significant. RESULTS: Ten samples of each mesh type were evaluated. There was no difference in tissue incorporation between the groups. The mean scar plate formation was greater in the heavyweight polypropylene meshes than for DualMesh (p = 0.04). With Proceed, the reduction in scar plate formation compared with that for Composix and Marlex approached statistical significance (p = 0.07). The mean number of inflammatory cells was greater around the ePTFE when compared with the midweight polypropylene (p = 0.02) but equal to the other meshes. CONCLUSIONS: The four prosthetic materials evaluated in this study demonstrate comparable host biocompatibility as evidenced by the tissue ingrowth. Scar plate formation around DualMesh was significantly less than that around Composix and Marlex. Interestingly, more inflammatory cells were noted surrounding the DualMesh which was equal to that of the heavyweight meshes. Proceed, a midweight polypropylene mesh, has the potential for improved patient tolerance compared to heavyweight polypropylene meshes based on its favorable histologic findings.


Asunto(s)
Hernia Abdominal/cirugía , Polipropilenos/análisis , Politetrafluoroetileno/análisis , Complicaciones Posoperatorias/patología , Mallas Quirúrgicas , Animales , Modelos Animales de Enfermedad , Estudios de Evaluación como Asunto , Femenino , Hernia Abdominal/patología , Inmunohistoquímica , Laparoscopía/métodos , Masculino , Ensayo de Materiales , Probabilidad , Implantación de Prótesis , Conejos , Distribución Aleatoria , Estadísticas no Paramétricas
6.
Am Surg ; 72(9): 808-13; discussion 813-4, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16986391

RESUMEN

Laparoscopic ventral hernia repair requires an intraperitoneal prosthetic; however, these materials are not without consequences. We evaluated host reaction to intraperitoneal placement of various prosthetics and the functional outcomes in an animal model. Mesh (n = 15 per mesh type) was implanted on intact peritoneum in New Zealand white rabbits. The mesh types included ePTFE (DualMesh), ePTFE and polypropylene (Composix), polypropylene and oxidized regenerated cellulose (Proceed), and polypropylene (Marlex). Adhesion formation was evaluated at 1, 4, 8, and 16 weeks using 2-mm mini-laparoscopy. Adhesion area, adhesion tenacity, prosthetic shrinkage, and compliance were evaluated after mesh explantation at 16 weeks. DualMesh had significantly less adhesions than Proceed, Composix, or Marlex at 1, 4, 8, and 16 weeks (P < 0.0001). Marlex had significantly more adhesions than other meshes at each time point (P < 0.0001). There were no statistically significant differences in adhesions between Proceed and Composix meshes. After mesh explantation, the mean area of adhesions for Proceed (4.6%) was less than for Marlex (21.7%; P = 0.001). The adhesions to Marlex were statistically more tenacious than the DualMesh and Composix groups. Overall prosthetic shrinkage was statistically greater for DualMesh (34.7%) than for the remaining mesh types (P < 0.01). Mesh compliance was similar between the groups. Prosthetic materials demonstrate a wide variety of characteristics when placed inside the abdomen. Marlex formed more adhesions with greater tenacity than the other mesh types. DualMesh resulted in minimal adhesions, but it shrank more than the other mesh types. Each prosthetic generates a varied host reaction. Better understanding of these reactions can allow a suitable prosthetic to be chosen for a given patient in clinical practice.


Asunto(s)
Materiales Biocompatibles/efectos adversos , Hernia Ventral/cirugía , Prótesis e Implantes/efectos adversos , Mallas Quirúrgicas/efectos adversos , Adherencias Tisulares/etiología , Animales , Modelos Animales de Enfermedad , Polímeros de Fluorocarbono/efectos adversos , Laparoscopía/efectos adversos , Laparoscopía/métodos , Polipropilenos/efectos adversos , Estudios Prospectivos , Conejos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...