Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Catheter Cardiovasc Interv ; 103(6): 995-1003, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38662126

RESUMEN

BACKGROUND: Limited data exists regarding incidence, progression, and predictors of left atrial appendage (LAA) sealing after transcatheter LAA closure. We aimed to evaluate the incidence, progression, and predictive factors associated with LAA sealing after LAA closure. METHODS: This study includes patients who underwent successful LAA closure with Watchman FLX device and had both pre- and postprocedural computed tomography (CT). Postprocedural CT was performed 45 days after LAA closure and used to evaluate residual LAA patency. Patient who had residual LAA patency at 45 days underwent 1-year follow-up CT. RESULTS: A total of 105 patients (mean age: 75.2 ± 9.6 years; 53.3% female) who underwent successful LAA closure with Watchman FLX device and had pre- and postprocedural CT at 45 days were included. Residual patency was observed in 35 (33.3%) patients: 21 (20.0%) patients showed complete contrast opacification in LAA (complete LAA patency) while 14 (13.3%) patients showed contrast opacification only in the distal LAA (distal LAA patency). Among patients with residual LAA patency at 45 days, the rate of LAA sealing at 1 year was significantly higher in the distal LAA patency group than in the complete LAA patency group (75.0% vs. 16.7%; p = 0.019). Increased depth oversizing was associated with both distal LAA patency and complete LAA patency. CONCLUSION: Postprocedural CT at 45 days detected patent LAA in one-third of patients after LAA closure. LAA sealing was more frequently observed at 1 year among the distal LAA patency group than the complete LAA patency group.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Cateterismo Cardíaco , Valor Predictivo de las Pruebas , Diseño de Prótesis , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/fisiopatología , Femenino , Masculino , Anciano , Anciano de 80 o más Años , Factores de Riesgo , Resultado del Tratamiento , Factores de Tiempo , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Estudios Retrospectivos , Incidencia , Tomografía Computarizada por Rayos X , Tomografía Computarizada Multidetector
2.
Artículo en Inglés | MEDLINE | ID: mdl-38267285

RESUMEN

BACKGROUND: Percutaneous left atrial appendage occlusion (LAAO) has emerged as a non-pharmacologic alternative to oral anticoagulation in reducing stroke risk in AF patients. However, patients with mitral valve disease (MVD), who are expected to have a significantly greater risk of left atrium (LA) thrombus formation and embolic stroke were excluded from randomized trials examining percutaneous LAAO. To address this gap, we present a national registry analysis of the use of LAAO among patients with MVD. METHODS: Using the National Readmissions Database, we performed a retrospective review of all hospitalizations for LAAO identified between September 2015 and November 2019. Of these, patients with ICD-10 codes for MVD were identified. Propensity matched (PSM) analysis was used to compare patients with MVD with a matched sample of patients undergoing LAAO with non-valvular AF. Outcomes examined included all-cause mortality, stroke, major bleeding, pericardial effusion (PE), and tamponade. RESULTS: 51,540 patients who underwent LAAO without a history of MVD and 3777 with a history of MVD were identified. Crude analysis demonstrated the odds of mortality, PE, and cardiac tamponade during index hospitalization to be higher in the MVD group. The length of stay and cost of index hospitalization were also slightly greater for the MVD group. A sample of 7649 patients (MVD: 3777 MVD and no MVD: 3872) were selected for PSM analysis with similar comorbidities across the two groups. In the PSM comparison, MVD was associated with higher risk of PE. The MVD group had a slightly higher rate of readmissions the association with PE remained at 30-day readmission (OR: 2.099 [1.360-3.238], p-value: <0.001). CONCLUSION: To our knowledge, this is the first study examining the use of LAAO among MVD patients. Our findings suggest that patients with MVD who underwent LAAO had a higher risk of post-procedural PE without an increase in mortality, stroke, or major bleeding. These results provide a rationale for considering LAAO as part of the stroke prevention strategy among patients with valvular AF.

4.
Catheter Cardiovasc Interv ; 103(1): 129-136, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37786977

RESUMEN

BACKGROUND: While studies have shown the advantages of computed tomography angiography (CTA) over transesophageal echocardiography (TEE) in left atrial appendage closure (LAAC) preprocedural planning for WATCHMAN™ legacy and FLX devices, there has been no reported long-term data for this approach. OBJECTIVES: We sought to evaluate long-term outcomes using CTA-based preprocedural planning for LAAC using the WATCHMAN™ device. METHODS: A prospective analysis of 231 consecutive patients who underwent LAAC in a single, large academic hospital in the United States was conducted over a 5-year period. CTA-guided preprocedural planning was performed in all. Procedural success, adverse events, length of procedure, number of devices used, and length of stay were evaluated. Rates of death, cerebral embolism, systemic embolism, and major and minor bleeding were recorded. Adjusted predicted stroke and major bleeding rates were derived from CHA2DS2-Vasc and HAS-BLED scores, respectively. RESULTS: From January 26, 2017, to November 23, 2021, 231 patients underwent LAAC with CTA preprocedural planning by two operating physicians. The mean age of patients was 76.5 ± 8.4. 59.7% of patients were male. Mean CHA2DS2VASc and HAS-BLED scores were 4.5 ± 1.4 and 3.9 ± 0.9, respectively. All procedures were performed with intracardiac echo (100%). The procedural success rate was 99.1%. The CTA sizing strategy accurately predicted the implant size in 93.5% of patients. Mean number of devices used was 1.10 ± 0.3. Peri-procedural complication rate was 2.2%. 6 patients were lost to follow-up. Mean follow-up was 608.94 days with a total of 377.04 patient years. Median follow-up period of 368 days (interquartile range: 209-1067 days). There were 51 deaths from all causes (13.52 per 100 patient-years), 10 cases of cerebral embolism (2.65 per 100 patient-years), 2 cases of systemic embolism (0.53 per 100 patient-years), 17 cases of major bleeding (4.50 per 100 patient-years), and 31 cases of minor bleeding (8.2 per 100 patient-years). All-cause mortality at 1, 2, and 3 years was 12.7%, 20.9%, and 29.2%, respectively. CV event rates at 1, 2, and 3 years were 2.1%, 6.6%, and 10.5%, respectively. CONCLUSIONS: CTA-based preprocedural planning is accurate in predicting device size for LAAC and associated with excellent clinical outcomes at 5 years.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Embolia , Embolia Intracraneal , Accidente Cerebrovascular , Humanos , Masculino , Femenino , Estudios de Seguimiento , Cierre del Apéndice Auricular Izquierdo , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Fibrilación Atrial/complicaciones , Angiografía por Tomografía Computarizada , Resultado del Tratamiento , Embolia Intracraneal/diagnóstico por imagen , Embolia Intracraneal/etiología , Embolia Intracraneal/prevención & control , Apéndice Atrial/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Hemorragia , Ecocardiografía Transesofágica/efectos adversos
5.
Catheter Cardiovasc Interv ; 103(1): 226-229, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37870093

RESUMEN

Peri-device leak after left atrial appendage closure (LAAC) is often treated with endovascular coils, plugs, or second occluders. This is the first study reporting the Amulet device used for peri-device leak. An 80-year-old male with paroxysmal atrial fibrillation and recurrent falls with head trauma who underwent LAAC with a 24 mm Watchman 2.5 device 3 years ago at another institution was referred to our clinic for management of the peri-device leak. Transesophageal echocardiogram showed persistent residual peri-device leak with 5 mm width along the Coumadin ridge aspect of the device. Computed tomography (CT) also showed the peri-device leak with width of 6 mm and complete opacification of left atrial appendage (LAA). Importantly, CT demonstrated that the Watchman 2.5 device was deployed at distal LAA, leaving the proximal part of LAA with length of 10 mm from ostium. Under general anesthesia, a 22 mm Amulet device was deployed successfully with complete sealing of LAA. Procedure planning is the key to minimize the risk of peri-device leak or device-related thrombosis. Careful assessment of LAA anatomy using multimodality images for peri-device leak after LAAC helped optimal treatment strategy including second LAAC with different type of devices.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Masculino , Humanos , Anciano de 80 o más Años , Cierre del Apéndice Auricular Izquierdo , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Warfarina , Ecocardiografía Transesofágica , Apéndice Atrial/diagnóstico por imagen
7.
Am J Cardiol ; 202: 176-181, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37441832

RESUMEN

Atrial fibrillation is the most common arrhythmia in patients with underlying malignancy. Patients with cancer have a higher risk of bleeding, and at the same time, carry an elevated risk of thromboembolism related to the hypercoagulable state, type of cancer, and anticancer treatment, rendering safe anticoagulation challenging in this population. Left atrial appendage closure is an alternative treatment option in patients with atrial fibrillation and high bleeding risk; however, the data on patients with cancer are limited. Our study aimed to compare the long-term outcomes in patients with cancer receiving left atrial appendage closure using the WATCHMAN device. This is a prospective, single-center study comparing outcomes in 389 patients who underwent percutaneous left atrial appendage closure using the WATCHMAN device over 5 years in a single, large academic hospital in the United States. The postprocedural outcomes of mortality, stroke, and major bleeding were evaluated in patients with and without cancer. Our study included 57 patients with cancer and 332 without cancer. The baseline characteristics were similar between the 2 groups. Metastatic disease was present in 16.4% of patients, and 25% were receiving active treatment at the time of the procedure. The median follow-up time was 354 (interquartile range 85 to 790) days. There was no difference in mortality (hazard ratio [HR] 1.3, 95% confidence interval [CI] 0.72 to 2.35, p = 0.38), major bleeding episodes (HR 1.2, 95% CI 0.45 to 3.33, p = 0.68), and stroke (HR 0.64, 95% CI 0.19 to 2.21, p = 0.49) at 3 years after the procedure in patients with and without cancer. There was no difference in the composite outcome (postprocedural mortality, stroke, and major bleeding) between the 2 groups (HR 1.25, CI 0.75 to 2.07, p = 0.38). Percutaneous left atrial appendage closure in patients with cancer appears to be safe and has a similar long-term risk compared with patients without cancer.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Neoplasias , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Anticoagulantes/uso terapéutico , Apéndice Atrial/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Hemorragia/inducido químicamente , Neoplasias/complicaciones , Neoplasias/patología
10.
J Invasive Cardiol ; 35(1): E1-E6, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36446576

RESUMEN

BACKGROUND: Though uncommon, pericardial effusion and cardiac tamponade are serious complications of left atrial appendage closure (LAAC). There are few data related to delayed pericardial effusions from this procedure. METHODS: This is a single-center prospective analysis of 369 patients who underwent LAAC from December 2016 to March 2022 at a large teaching hospital. We compared patients who developed effusion (n = 5) to patients who did not (n = 364) to determine if there were any factors that predispose patients to developing acute (AEs) or delayed pericardial effusions (DEs). We compared patient characteristics, procedural data, and complications. Unadjusted, stepwise multivariate logistic regression was performed. RESULTS: A total of 369 patients underwent LAAC. Of these, 5 patients (1.4%) developed pericardial effusion. Patients in both groups (pericardial effusion vs non-effusion) had similar patient and procedural characteristics. Patients in both groups were older (mean age, 78.4 ± 7.8 years in the effusion group vs 76.3 ± 8.5 years in the non-effusion group; P=.50) and white (60% in the effusion group vs 90.1% in the non-effusion group). CHA2DS2-VASc (4.2 ± 1.1 vs 4.5 ± 1.4; P=.67) and HAS-BLED (3.4 ± 0.5 vs 3.7 ± 0.9; P=.53) scores were similar in the effusion group vs the non-effusion group, respectively. Gastrointestinal bleeding was the most common procedural indication in both groups (80% in the effusion group vs 53.6% in the non-effusion group; P=.23). The majority of the patients in both groups had successful implantation in the first attempt, with the 27-mm device the most commonly used size. There was no significant difference in procedural duration (67 minutes in the effusion group vs 75 minutes in the non-effusion group; P=.16). Among patients who received the Watchman Legacy device, 2 patients developed AEs and no patients had DEs. Of those receiving the Watchman FLX device, 1 patient developed AE and 2 patients developed DEs. All of the patients with effusions had successful recovery. CONCLUSION: In this 5-year, single-center experience, DEs were uncommon and potentially related to LAA device anchor microperforation. No statistically significant risk factors predisposing patients to pericardial effusions were identified in our analysis.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Derrame Pericárdico , Accidente Cerebrovascular , Humanos , Anciano , Anciano de 80 o más Años , Derrame Pericárdico/diagnóstico , Derrame Pericárdico/epidemiología , Derrame Pericárdico/etiología , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Resultado del Tratamiento , Factores de Riesgo , Cateterismo Cardíaco/métodos , Accidente Cerebrovascular/etiología
12.
Am J Cardiol ; 189: 1-10, 2023 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-36481373

RESUMEN

Permanent pacemaker implantation (PPMI) reduction and optimal management of newly acquired conduction disturbances after transcatheter aortic valve implantation (TAVI) are crucial. We sought to evaluate the relation between transcatheter heart valve (THV) implantation depth and baseline and newly acquired conduction disturbances on PPMI after TAVI. This study included 1,026 consecutive patients with severe symptomatic aortic stenosis (mean age 79.7 ± 8.4 years; 47.4% female) who underwent TAVI with the newer-generation self-expanding THVs Primary outcomes were early and late PPMI defined as the need for PPMI during the index admission and between discharge and 30 days, respectively. Early and late PPMI was required for 115 (11.2%) and 21 patients (2.0%), respectively. Early PPMI rates decreased from 26.7% in 2015 and 2016 to 5.7% in 2021, and so did the mean THV depth from 4.4 ± 2.4 mm to 1.8 ± 1.6 mm. Receiver operator characteristics curve analyses showed THV depth had significant discriminatory value for early and late PPMI with cutoff values of 3.0 and 2.2 mm, respectively. Rates of early and late PPMI were significantly lower for patients with shallower compared with deeper implantations (5.1% vs 22.6% and 0.4% vs 4.1%, p <0.001 for both, respectively). Furthermore, rates of early PPMI were lower with shallower implantations in patients with new left bundle branch block after TAVI (2.4% vs 15.9%; p <0.001) and those with baseline right bundle branch block (7.5% vs 29.6%; p = 0.017). Lower rates of PPMI with shallower THV implantation were consistently observed, including in patients with baseline and newly acquired conduction disturbances. Our findings might help optimize the management of a temporary pacemaker after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Bloqueo de Rama/terapia
16.
Am. j. cardiol ; 15(175): 80-87, July. 2022.
Artículo en Inglés | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1377949

RESUMEN

ABSTRACT Previous studies reported that new-onset persistent left bundle branch block (NOP-LBBB) was related to worse outcomes after transcatheter aortic valve implantation (TAVI). However, these results can be confounded by the presence of permanent pacemaker (PPM) implantation before and after TAVI. Long-term outcomes and the risk stratification of NOP-LBBB not having PPM implantation before and after TAVI have not been fully investigated. This is an international, multicenter, retrospective study of patients who underwent TAVI from July 31, 2007, to May 8, 2020. A total of 2,240 patients were included, and 17.5% of patients developed NOP-LBBB. NOP-LBBB was associated with cardiac mortality (adjusted hazard ratio [aHR] 1.419, 95% confidence interval [CI] 1.014 to 1.985, p = 0.041) and the composite outcomes of cardiac mortality and/or heart failure readmission (aHR 1.313, 95% CI 1.027 to 1.678, p = 0.030). Patients who developed NOP-LBBB with pre-TAVI left ventricular ejection fraction (LVEF) <40% were significantly associated with cardiac mortality (aHR 2.049, 95% CI 1.039 to 4.041, p = 0.038), heart failure (aHR 3.990, 95% CI 2.362 to 6.741, p <0.001), and the composite outcome (aHR 2.729, 95% CI 1.703 to 4.374, p <0.001). Although NOP-LBBB with pre-TAVI LVEF >40% had a significant decrease in LVEF 6 to 12 months after TAVI (-1.8 ± 9.7% vs +0.6 ± 8.1%, p = 0.003), NOP-LBBB with pre-TAVI LVEF <40% had a significant increase in LVEF 6 to 12 months after TAVI (+9.7 ± 13.6% vs +13.0 ± 11.7%, p = 0.157). In conclusion, patients with NOP-LBBB without pre-TAVI and post-TAVI PPM developed significantly worse long-term outcomes, especially in patients with pre-TAVI LVEF <40%. Further prospective investigation should be undertaken.


Asunto(s)
Bloqueo de Rama , Reemplazo de la Válvula Aórtica Transcatéter , Insuficiencia Cardíaca
17.
J Cardiovasc Electrophysiol ; 33(8): 1781-1787, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35586899

RESUMEN

BACKGROUND: While there is recent data suggesting an advantage of computed tomography angiography (CTA) over transesophageal echocardiography (TEE) for preprocedural left atrial appendage closure (LAAC) planning, there is limited published experience for sizing strategies. Device sizing for LAAC may be challenging and noninvasive algorithms that improve this selection process are warranted. OBJECTIVES: We sought to evaluate the safety and the feasibility for the implementation of a novel CTA-based sizing methodology for WATCHMAN™ FLX device in a series of patients undergoing LAAC using the TruPlan™ software package. METHODS: A prospective analysis of 136 consecutive patients who underwent LAAC over a 12-month period in a single, large academic hospital in the United States was conducted. CTA-guided preprocedural planning and intracardiac echocardiography (ICE) was performed in all. Procedural success, adverse events, length of procedure, number of devices used, and length of stay were evaluated. RESULTS: A total of 136 patients who underwent LAAC procedure with WATCHMAN™ FLX platform between October 1, 2020 until September 30, 2021 were included. The pre-specified protocol using CTA and ICE was implemented in all patients (100%). Mean CHA2 DS2 VASc score was 4.4 ± 1.3 and the mean HAS-BLED score was 3.9 ± 0.8. ICE-guided 100% transseptal puncture success rate was 100% with 98.5% of overall procedural success rate. Preprocedural CTA sizing strategy accurately predicted the implanted size in 91.1% of patients. Ten patients (7.4%) required another sized device and 2 cases were aborted. At 45-day follow-up, only 1 patient (0.7%) had significant peri-device leak (≥5 mm) on TEE. CONCLUSIONS: CTA-based preprocedural sizing methodology for WATCHMAN™ FLX in LAAC was safe, feasible and associated with excellent procedural outcomes. Further studies are warranted to confirm if the features specific to TruPlan™ may reduce the number of deployment attempts, the number of devices utilized in the procedure, and the risk of complications.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Cateterismo Cardíaco , Angiografía por Tomografía Computarizada/métodos , Ecocardiografía Transesofágica/métodos , Humanos , Resultado del Tratamiento
18.
Am J Cardiol ; 175: 80-87, 2022 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-35597627

RESUMEN

Previous studies reported that new-onset persistent left bundle branch block (NOP-LBBB) was related to worse outcomes after transcatheter aortic valve implantation (TAVI). However, these results can be confounded by the presence of permanent pacemaker (PPM) implantation before and after TAVI. Long-term outcomes and the risk stratification of NOP-LBBB not having PPM implantation before and after TAVI have not been fully investigated. This is an international, multicenter, retrospective study of patients who underwent TAVI from July 31, 2007, to May 8, 2020. A total of 2,240 patients were included, and 17.5% of patients developed NOP-LBBB. NOP-LBBB was associated with cardiac mortality (adjusted hazard ratio [aHR] 1.419, 95% confidence interval [CI] 1.014 to 1.985, p = 0.041) and the composite outcomes of cardiac mortality and/or heart failure readmission (aHR 1.313, 95% CI 1.027 to 1.678, p = 0.030). Patients who developed NOP-LBBB with pre-TAVI left ventricular ejection fraction (LVEF) <40% were significantly associated with cardiac mortality (aHR 2.049, 95% CI 1.039 to 4.041, p = 0.038), heart failure (aHR 3.990, 95% CI 2.362 to 6.741, p <0.001), and the composite outcome (aHR 2.729, 95% CI 1.703 to 4.374, p <0.001). Although NOP-LBBB with pre-TAVI LVEF >40% had a significant decrease in LVEF 6 to 12 months after TAVI (-1.8 ± 9.7% vs +0.6 ± 8.1%, p = 0.003), NOP-LBBB with pre-TAVI LVEF <40% had a significant increase in LVEF 6 to 12 months after TAVI (+9.7 ± 13.6% vs +13.0 ± 11.7%, p = 0.157). In conclusion, patients with NOP-LBBB without pre-TAVI and post-TAVI PPM developed significantly worse long-term outcomes, especially in patients with pre-TAVI LVEF <40%. Further prospective investigation should be undertaken.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Bloqueo de Rama/epidemiología , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Insuficiencia Cardíaca/epidemiología , Humanos , Estudios Retrospectivos , Medición de Riesgo/métodos , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Función Ventricular Izquierda
19.
Rev Cardiovasc Med ; 23(3): 104, 2022 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-35345271

RESUMEN

BACKGROUND: Endovascular therapeutic hypothermia (ETH) reduces the damage by ischemia/reperfusion cell syndrome in cardiac arrest and has been studied as an adjuvant therapy to percutaneous coronary intervention (PCI) in ST-elevation myocardial infarction (STEMI). New available advanced technology allows cooling much faster, but there is paucity of resources for training to avoid delays in door-to-balloon time (DTB) due to ETH and subsequently coronary reperfusion, which would derail the procedure. The aim of the study was to describe the process for the development of a simulation, training & educational protocol for the multidisciplinary team to perform optimized ETH as an adjunctive therapy for STEMI. METHODS AND RESULTS: We developed an optimized simulation protocol using modern mannequins in different realistic scenarios for the treatment of patients undergoing ETH adjunctive to PCI for STEMIs starting from the emergency room, through the CathLab, and to the intensive care unit (ICU) using the Proteus® Endovascular System (Zoll Circulation Inc™, San Jose, CA, USA). The primary endpoint was door-to-balloon (DTB) time. We successfully trained 361 multidisciplinary professionals in realistic simulation using modern mannequins and sham situations in divisions of the hospital where real patients would be treated. The focus of simulation and training was logistical optimization and educational debriefing with strategies to reduce waste of time in patient's transportation from different departments, and avoiding excessive rewarming during transfer. Afterwards, the EHT protocol was successfully validated in a trial randomizing 50 patients for 18 minutes cooling before coronary recanalization at the target temperature of 32 ± 1.0 ∘C or PCI-only. A total of 35 patients underwent ETH (85.7% [30/35] in 90 ± 15 minutes), without delays in the mean door-to-balloon time for primary PCI when compared to 15 control group patients (92.1 minutes versus 87 minutes, respectively; p = 0.509). CONCLUSIONS: Realistic simulation, intensive training and educational debriefing for the multidisciplinary team propitiated feasible endovascular therapeutic hypothermia as an adjuvant therapy to primary PCI in STEMI. CLINICALTRIALS: gov: NCT02664194.


Asunto(s)
Hipotermia Inducida , Infarto del Miocardio , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Hipotermia Inducida/efectos adversos , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Infarto del Miocardio con Elevación del ST/diagnóstico , Infarto del Miocardio con Elevación del ST/terapia , Factores de Tiempo , Resultado del Tratamiento
20.
J Invasive Cardiol ; 34(2): E124-E131, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-35100555

RESUMEN

BACKGROUND: Percutaneous left atrial appendage occlusion (LAAO) with the Watchman device is FDA approved for stroke prevention in patients with nonvalvular atrial fibrillation who have an appropriate indication. During the COVID-19 pandemic, a same-day discharge protocol (SDDP) was employed to improve resource utilization, relieve hospital occupation, and reduce the possible risk of in-hospital virus transmission. OBJECTIVES: We sought to analyze the safety, feasibility, and cost effectiveness for SDDP in patients receiving LAAO. METHODS: A prospective analysis of 142 consecutive patients, 119 treated prior to SDDP and 23 who underwent SDDP following LAAO with cardiac computed tomography angiography (CTA)-guided pre-procedural planning and intracardiac echocardiogram (ICE). Procedures were performed in a single, large academic hospital in the United States. In-hospital and 45-day procedural success, adverse events, length of procedure, and length-of-stay were evaluated. RESULTS: Baseline patient characteristics including mean CHA2DS2VASc scores and mean HAS-BLED scores were similar in both groups. All procedures were successful. There was no significant difference in rates of procedural complications or in-hospital adverse events. The mean procedure time in the SDDP group was 11 minutes longer than in the conventional group (62.1 ± 5.9 vs 51.1 ± 21; P=.01). Outcomes at 45-day follow-up were similar. SDDP was associated with a reduced length of stay compared with conventional strategy and a 15% reduction in total costs. CONCLUSIONS: Same-day discharge strategy for LAAO appears safe, feasible and could become the new standard approach for LAAO. A protocol including CTA pre-procedural planning, ICE-guided deployment and conscious sedation reduces hospital occupation and lowers costs.


Asunto(s)
Apéndice Atrial , COVID-19 , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Cateterismo Cardíaco , Análisis Costo-Beneficio , Humanos , Pandemias , Alta del Paciente , SARS-CoV-2 , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...