Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-27739183

RESUMEN

BACKGROUND: Competent interpretation of esophageal high-resolution manometry (HRM) is integral to a quality study. Currently, methods to assess physician competency for the interpretation of esophageal HRM do not exist. The aim of this study was to use formal techniques to (i) develop an HRM interpretation exam, and (ii) establish minimum competence benchmarks for HRM interpretation skills at the trainee, physician interpreter, and master level. METHODS: A total of 29 physicians from 8 academic centers participated in the study: 9 content experts separated into 2 study groups-expert test-takers (n=7) and judges (n=2), and 20 HRM inexperienced trainees ("trainee test-taker"; n=20). We designed the HRM interpretation exam based on expert consensus. Expert and trainee test-takers (n=27) completed the exam. According to the modified Angoff method, the judges reviewed the test-taker performance and established minimum competency cut scores for HRM interpretation skills. KEY RESULTS: The HRM interpretation exam consists of 22 HRM cases with 8 HRM interpretation skills per case: identification of pressure inversion point, hiatal hernia >3 cm, integrated relaxation pressure, distal contractile integral, distal latency, peristaltic integrity, pressurization pattern, and diagnosis. Based on the modified Angoff method, minimum cut scores for HRM interpretation skills at the trainee, physician interpreter, and master level ranged from 65-80%, 85-90% (with the exception of peristaltic integrity), and 90-95%, respectively. CONCLUSIONS & INFERENCES: Using a formal standard setting technique, we established minimum cut scores for eight HRM interpretation skills across interpreter levels. This examination and associated cut scores can be applied in clinical practice to judge competency.


Asunto(s)
Benchmarking/normas , Competencia Clínica/normas , Trastornos de la Motilidad Esofágica/diagnóstico , Trastornos de la Motilidad Esofágica/fisiopatología , Manometría/normas , Rol del Médico , Benchmarking/métodos , Esófago/fisiopatología , Humanos , Manometría/métodos , Encuestas y Cuestionarios
2.
Endoscopy ; 41(3): 194-9, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19280530

RESUMEN

BACKGROUND AND AIM: Indications for small-bowel enteroscopy are increasing, but advancing the endoscope to the ileum remains challenging, especially for less experienced operators. The aim was to evaluate the ease of use, safety, and efficacy of the Discovery SB overtube (Spirus Medical, Stoughton, Massachusetts, USA) during SB enteroscopy by physicians with no experience of the device. PATIENTS AND METHODS: Thirty-three "untrained" endoscopists performed spiral enteroscopy during one of four 2-day training modules. Data were prospectively collected. Patient demographics, depth and time to maximal insertion, total procedure time, and findings were recorded. Trauma was documented during scope withdrawal. Day 1 and day 2 results were compared. RESULTS: Ninety procedures were successfully performed in 95 patients (72.6 % women, age = 48.8 +/- 14.2 years). Endoscopists each performed a mean of five procedures. Mean time to maximal insertion was 20.9 +/- 6.4 minutes. Mean depth achieved was 262.0 +/- 57.4 cm. Total procedure time was 33.6 +/- 8.0 minutes. In 90.3 %, 94.6 %, and 83.9 % of patients, respectively, a trauma score less than 3 was recorded in the esophagus, stomach, and intestine (scale = 0 - 5). There were no perforations, nor significant associations between trauma score and patient age, body mass index, depth of insertion, time to maximal insertion, total procedure time, or day 1 vs. day 2 procedures. Depth of insertion was greater on day 2 than on day 1 (276.9 +/- 53.7 cm vs. 252.0 +/- 58.0 cm, P = 0.043). CONCLUSIONS: Discovery SB provides safe advancement of the enteroscope into the distal small bowel. Maximum depth of insertion appears comparable to that of balloon enteroscopy while taking less time. The device is easy to use and may be effectively operated in as few as five training cases.


Asunto(s)
Endoscopios Gastrointestinales , Femenino , Humanos , Íleon/patología , Intestino Delgado , Masculino , Persona de Mediana Edad , Estudios Prospectivos
3.
4.
Plant Cell Rep ; 10(8): 417-20, 1991 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24221737

RESUMEN

A protocol for regenerating plants from callus-derived protoplasts of Pelargonium x domesticum (rega l geranium cv. 'Melissa') has been developed. Protoplasts were isolated from leaf-derived callus tissue on MS medium supplemented with 3.0 mg/l naphthalene acetic acid, 2.0 mg/l 6- benzylaminopurine, and 3.0% sucrose. This callus yielded 2.7×10(5) protoplasts/gram of tissue after a 6 hr incubation in an enzyme solution consisting of 2.0% cellulysin, 0.5% macerase, and 0.5 M sucrose. Protoplasts were plated at 1×10(5) protoplasts/ml in a mixture (1∶1 v/v) of KMP8/KP liquid medium layered on the same medium solidified with 0.6% agarose. Protoplast division was initiated within 2 days, and colonies of 15 to 50 cells developed 8 wk after plating. P-calli 1-2 mm(3) developed 15 wk after plating, and plants regenerated from the p-calli have been transferred to the greenhouse.

5.
J Nurs Adm ; 20(6): 6, 1990 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-2348250
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA