Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Eur J Cardiothorac Surg ; 61(1): 152-159, 2021 Dec 27.
Artículo en Inglés | MEDLINE | ID: mdl-34355742

RESUMEN

OBJECTIVES: We investigated the anatomical evolution of residual aortic dissection after type A repair and factors associated with poor prognosis at a high-volume aortic centre. METHODS: Between 2017 and 2019, all type A aortic dissections were included for prospective follow-up. Patients without follow-up computed tomography (CT) scan available for radiological analysis and patients without residual aortic dissection were excluded from this study. The primary end point was a composite end point defined as dissection-related events including aneurysmal evolution (increased diameter > 5 mm/year), aortic reintervention for malperfusion syndrome, aortic diameter >55 mm, rapid aortic growth >10 mm/year or aortic rupture and death. The secondary end points were risk factors for dissection-related events and reintervention analysis. All immediate and last postoperative CT scans were analysed. RESULTS: Among 104 patients, after a mean follow-up of 20.4 months (8-41), the risk of dissection-related events was 46.1% (48/104) and the risk of distal reintervention was 17.3% (18/104). Marfan syndrome (P < 0.01), aortic bicuspid valve (P = 0.038), innominate artery debranching (P = 0.025), short aortic cross-clamp time (P = 0.011), initial aortic diameter >40 mm (P < 0.01) and absence of resection of the primary entry tear (P = 0.015) were associated with an increased risk of dissection-related events or reintervention during follow-up. CONCLUSIONS: Residual aortic dissection is a serious disease requiring close follow-up at an expert centre. This study shows higher reintervention and aneurysmal development rates than currently published. To improve long-term outcomes, the early demographic and anatomic poor prognostic factors identified may be used for more aggressive treatment at an early phase.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Disección Aórtica/complicaciones , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Estudios de Seguimiento , Humanos , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
2.
Circ Cardiovasc Imaging ; 13(6): e009886, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32507018

RESUMEN

Background Color-duplex ultrasonography (DUS) could be an alternative to computed tomography-aortography (CTA) in the lifelong surveillance of patients after endovascular aneurysm repair (EVAR), but there is currently no level 1 evidence. The aim of this study was to assess the diagnostic accuracy of DUS as an alternative to CTA for the follow-up of post-EVAR patients. Methods Between December 16, 2010, and June 12, 2015, we conducted a prospective, blinded, diagnostic-accuracy study, in 15 French university hospitals where EVAR was commonly performed. Participants were followed up using both DUS and CTA in a mutually blinded setup until the end of the study or until any major aneurysm-related morphological abnormality requiring reintervention or an amendment to the follow-up policy was revealed by CTA. Database was locked on October 2, 2017. Our main outcome measures were sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratios of DUS against reference standard CTA. CIs are binomial 95% CI. Results This study recruited prospectively 659 post-EVAR patients of whom 539 (82%) were eligible for further analysis. Following the baseline inclusion visit, 940 additional follow-up visits were performed in the 539 patients. Major aneurysm-related morphological abnormalities were revealed by CTA in 103 patients (17.2/100 person-years [95% CI, 13.9-20.5]). DUS accurately identified 40 patients where a major aneurysm-related morphological abnormality was present (sensitivity, 39% [95% CI, 29-48]) and 403 of 436 patients with negative CTA (specificity, 92% [95% CI, 90-95]). The negative predictive value and positive predictive value of DUS were 92% (95% CI, 90-95) and 39% (95% CI, 27-50), respectively. The positive likelihood ratio was 4.87 (95% CI, 2.9-9.6). DUS sensitivity reached 73% (95% CI, 51-96) in patients requiring an effective reintervention. Conclusions DUS had an overall low sensitivity in the follow-up of patients after EVAR, but its performance improved meaningfully when the subset of patients requiring effective reinterventions was considered. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT01230203.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Aortografía/métodos , Implantación de Prótesis Vascular , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares , Tomografía Computarizada Multidetector , Complicaciones Posoperatorias/diagnóstico por imagen , Ultrasonografía Doppler en Color , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Francia , Humanos , Masculino , Complicaciones Posoperatorias/terapia , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Retratamiento , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...