Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Kidney Blood Press Res ; 49(1): 9-19, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38096797

RESUMEN

BACKGROUND: Autosomal dominant polycystic kidney disease (ADPKD) is the most common hereditary kidney disease with a prevalence of 1:400 to 1:1,000 in Caucasians. It is caused by mutations in the PKD1 gene located on chromosome 16p13.3 (in about 85% cases) as well as in the PKD2 gene on chromosome 4q13-23. In the Polish population, the disease is associated with PKD1 mutations in 84% of the ADPKD-affected families. PKD1 and PKD2 genes encode the proteins polycystin-1 (PC1) and polycystin-2 (PC2), respectively. The presence of kidney cysts is a characteristic feature in the ADPKD patients. But in the ADPKD patients, cardiovascular abnormalities, such as hypertension (HT) with higher systolic blood pressure (SBP) and diastolic blood pressure (DBP) values, higher left ventricular mass (LVM), intracranial (ICAN) and extracranial aneurysms, and cardiac valve defects, are significantly more common than in the general population. SUMMARY: According to the literature data, both higher LVM and vascular dysfunction already occur in children and young adults with normal renal function and without HT. Moreover, biventricular diastolic dysfunction, endothelial dysfunction, increased carotid intima-media thickness, and impaired coronary flow velocity reserve are present even in young patients with ADPKD who have normal HT and well-preserved renal function. In patients with ADPKD, hypertension has some specific features; in the youngest age group of children, the prevalence of hypertension is greater if their parents suffer from hypertension; in normotensive young ADPKD-diagnosed individuals, ambulant SBP and DBP values were significantly higher than in age- and gender-matched controls; hypertension appears at least 10 years earlier than spontaneous HT in general population. In adults, HT is often diagnosed before any substantial reduction in the GFR, and a lower nocturnal dip in BP in comparison to hypertensives in the general population. PKD1 and PKD2 gene products (PC1 and PC2 proteins) have been shown to assemble at the plasma membrane and to regulate calcium (Ca2+) entry. A defect in Ca2+ binding mediated by mutations in polycystin proteins is a hypothetical factor contributing to left ventricular mass increase. Altered intracellular Ca2+ handling contributes importantly to impaired contractility associated with heart failure. Impairment of intracellular Ca2+ homeostasis and mitochondrial function has been implicated in the development of LVH. KEY MESSAGES: It can be assumed that the cause of LVH in ADPKD patients is the natural course of this disease with developing HT and deteriorating kidney function, which may be influenced by the presence of PKD1- and PKD2-mutated gene products: PC1 and PC2 proteins.


Asunto(s)
Hipertensión , Riñón Poliquístico Autosómico Dominante , Niño , Adulto Joven , Humanos , Riñón Poliquístico Autosómico Dominante/complicaciones , Riñón Poliquístico Autosómico Dominante/genética , Canales Catiónicos TRPP/genética , Calcio/metabolismo , Grosor Intima-Media Carotídeo , Hipertensión/complicaciones
2.
Medicina (Kaunas) ; 59(12)2023 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-38138253

RESUMEN

Background and Objectives: Provisional extension to induce complete attachment (PETTICOAT) is suggested as being associated with a lower incidence of aorta-related events and fewer reinterventions compared to thoracic endovascular aortic repair (TEVAR) in patients with complicated acute, and subacute type B aortic dissections. Materials and Methods: This article is a systematic review and meta-analysis following the PRISMA guidelines. The Medline, PubMed, Embase, and Cochrane databases were searched, starting on 21 February 2022 and ending on 22 June 2022, to identify studies that investigated the rate of postoperative complications in patients treated with the PETTICOAT compared to the TEVAR. A random effects meta-analysis was performed. Of 2350 studies, 5 studies involving 360 patients were included: 143 patients after the PETTICOAT procedure and 217 after the TEVAR. Results: The meta-analysis of all studies showed that the rate of secondary endovascular reinterventions was smaller in patients treated with the PETTICOAT (n = 3 studies; OR, 0.30; 95% CI, 0.10 to 0.94; p = 0.04). The results of other postoperative complications (30-day mortality, mortality during follow-up, paraplegia, stroke, and occurrence of endoleak) were lower in the PETTICOAT group but were not statistically significant. The rate of postoperative renal failure was lower in patients treated with the TEVAR (n = 4; OR, 1.08; 95% CI, 0.46 to 2.51; p = 0.86). Conclusion: This meta-analysis suggests that the PETTICOAT procedure is related to the lower rate of secondary endovascular reinterventions for complicated acute, and subacute type B aortic dissections.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular , Reparación Endovascular de Aneurismas , Implantación de Prótesis Vascular/efectos adversos , Stents/efectos adversos , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Resultado del Tratamiento , Disección Aórtica/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Estudios Retrospectivos , Factores de Riesgo
3.
J Clin Med ; 12(21)2023 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-37959199

RESUMEN

This study aimed to investigate the relationship between maximum transverse diameter (MTD) and volume measurements in patients who underwent reoperations after endovascular aneurysm repair (EVAR), and their association with the occurrence of endoleaks. The study included 51 patients who underwent EVAR and subsequent re-operations caused by endoleaks type I-III. In some number of events, multiple re-operations were needed. MTD was measured using the Horos software, and segmentations of the AAA were performed using 3D Slicer. This study first evaluated post-operative computed tomography angiography (CTA) to measure MTD and volume. Then, similar measurements were made in the control scan for re-operation qualification. Negative remodeling (increase in MTD and/or volume) was observed in 40 cases using MTD, and 48 cases using volume measurements. The volume measurement showed lower missed negatives than MTD, indicating its effectiveness in screening for negative remodeling (p < 0.001). Combining both methods identified 51 negative remodeling cases and 8 positive changes, with a higher sensitivity compared to MTD alone. The volume of the sac did not predict specific endoleak types. Decreases in MTD were observed in smaller sacs, with smaller volume changes. Volume measurement is a valuable screening tool, and combining MTD and volume enhances sensitivity. However, sac volume does not predict endoleak type.

4.
J Cardiovasc Dev Dis ; 10(11)2023 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-37998522

RESUMEN

We sought to determine the role of the patient-specific, three-dimensional (3D) holographic vascular model in patient medical knowledge and its influence on obtaining a more conscious informed consent process for percutaneous balloon angioplasty (PTA). Patients with peripheral arterial disease who had been scheduled for PTA were enrolled in the study. Information regarding the primary disease, planned procedure, and informed consent was recorded in typical fashion. Subsequently, the disease and procedure details were presented to the patient, showing the patients their individual model. A patient and medical supervisor equipped with mixed reality headsets could both simultaneously manipulate the hologram using gestures. The holographic 3D model had been created on a scale of 1:1 based on computed tomography scans. The patient's knowledge was tested by the completion of a questionnaire before and after the interaction in a mixed reality environment. Seventy-nine patients manipulated arterial holograms in mixed reality head-mounted devices. Before the 3D holographic artery model interaction, the mean ± standard deviation score of the knowledge test was 2.95 ± 1.21 points. After the presentation, the score had increased to 4.39 ± 0.82, with a statistically significant difference (p = 0.0000) between the two scores. Using a Likert scale from 1 to 5, the patients had scored the use of the 3D holographic model at 3.90 points regarding its usefulness in comprehending their medical condition; at 4.04 points regarding the evaluation of the holograms as helpful in understanding the course of surgery; and rated the model at 1.99 points in reducing procedure-related stress. Using a nominal scale (know or don't know), the patients had self-assessed their knowledge of the procedure before and after the 3D model presentation, with a score of 6.29 ± 2.01 and 8.39 ± 1.54, respectively. The study group tolerated the use of head-mounted devices. Only one patient had nausea and dizziness, while four patients experienced transient eye pain. The 3D holographic arterial model aided in the understanding of patients' knowledge regarding the disease and procedure, making the informed consent process more conscious. The holograms improved the patient's self-consciousness. Mixed reality headset-related complications were rare and within acceptable rates.

5.
JVS Vasc Sci ; 4: 100092, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36874956

RESUMEN

Objective: The human acellular vessel (HAV) was evaluated for surgical bypass in a phase II study. The primary results at 24 months after implantation have been reported, and the patients will be evaluated for ≤10 years. Methods: In the present report, we have described the 6-year results of a prospective, open-label, single-treatment arm, multicenter study. Patients with advanced peripheral artery disease (PAD) requiring above-the-knee femoropopliteal bypass surgery without available autologous graft options had undergone implantation with the HAV, a bioengineered human tissue replacement blood vessel. The patients who completed the 24-month primary portion of the study will be evaluated for ≤10 years after implantation. The present mid-term analysis was performed at the 6-year milestone (72 months) for patients followed up for 24 to 72 months. Results: HAVs were implanted in 20 patients at three sites in Poland. Seven patients had discontinued the study before completing the 2-year portion of the study: four after graft occlusion had occurred and three who had died of causes deemed unrelated to the conduit, with the HAV reported as functional at their last visit. The primary results at 24 months showed primary, primary assisted, and secondary patency rates of 58%, 58%, and 74%, respectively. One vessel had developed a pseudoaneurysm deemed possibly iatrogenic; no other signs of structural failure were reported. No rejections or infections of the HAV occurred, and no patient had required amputation of the implanted limb. Of the 20 patients, 13 had completed the primary portion of the study; however, 1 patient had died shortly after 24 months. Of the remaining 12 patients, 3 died of causes unrelated to the HAV. One patient had required thrombectomy twice, with secondary patency achieved. No other interventions were recorded between 24 and 72 months. At 72 months, five patients had a patent HAV, including four patients with primary patency. For the entire study population from day 1 to month 72, the overall primary, primary assisted, and secondary patency rate estimated using Kaplan-Meier analysis was 44%, 45%, and 60% respectively, with censoring for death. No patient had experienced rejection or infection of the HAV, and no patient had required amputation of the implanted limb. Conclusions: The infection-resistant, off-the-shelf HAV could provide a durable alternative conduit in the arterial circuit setting to restore the lower extremity blood supply in patients with PAD, with remodeling into the recipient's own vessel over time. The HAV is currently being evaluated in seven clinical trials to treat PAD, vascular trauma, and as a hemodialysis access conduit.

6.
Ann Vasc Surg ; 89: 210-215, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36064129

RESUMEN

BACKGROUND: Published interim results of the extended provisional extension to induce complete attachment (e-PETTICOAT) technique suggested favorable remodeling in chronic type B Aortic Dissection (cTBAD). This report presents long-term results of the e-PETTICOAT technique for the management of cTBAD (without aneurysmal dilatation). METHODS: Patients with cTBAD below the 55 mm aortic size were eligible for the management using the e-PETTICOAT technique. Follow-up was conducted at 1, 2 and 5 years based on the computed tomography angiogram. All the presurgery risk factors (entry >1 cm, inner curve entry, fusiform index >0.65, false lumen > 22 mm, aortic size >40 mm, recurrent pain or hypertension, and Stanford Dissection Risk Calculation) and postsurgery complications were examined in the study. RESULTS: A total of 20 patients underwent the e-PETTICOAT surgery. The survival rate at 1, 2, and 5 years was 75%, 70%, and 64%, respectively, and the percentage of patients without any reinterventions was 100%, 93%, and 18%. Aortic degeneration was recognized in 30%, 55%, and 85% of the patients. Only 3 of the 20 patients were alive and without any reintervention after 5 years. The receiver operating curve analysis does not indicate any factor that would predict the remodeling result in the long-term follow-up. CONCLUSIONS: The use of e-PETTICOAT technique in cTBAD might not have a beneficial influence on the long-term results.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Stents , Procedimientos Endovasculares/efectos adversos , Resultado del Tratamiento , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aortografía/métodos , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/etiología , Estudios Retrospectivos
7.
J Endovasc Ther ; 30(5): 769-778, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-35543452

RESUMEN

PURPOSE: Physician-modified stent-grafts (PMSG) are widely used, especially when a patient's condition precludes waiting for a custom-made device. In recent years, the modification process has been upgraded using 3-dimensional (3D) aortic templates. Nonetheless, the reliability of PMSG and accuracy of fenestration alignment with the target vessel are not known. Thus, the study is aimed to fulfill the gap in current knowledge. MATERIALS AND METHODS: Ten computed tomographic (CT) scans of aortic aneurysm previously treated with the fenestrated endovascular repair were selected to 3D-print aortic templates and elastic vessel phantoms. Two vascular surgeons performed fenestrations using the 3D template and modification plan based on CT measurements. Two operators each performed 10 fenestrated stent-grafts in the aortic template and 10 using CT measurements, for a total of 40 fenestrated stent-grafts. Then, stent-grafts were implanted in elastic vessel phantoms, which served to evaluate fenestration alignment with the target vessel. The alignment was judged in a 5-point scale: 0%, 1% to 25%, 26% to 50%, 51% to 75%, and 76% to 100%. The distances between fenestrations served to calculate interobserver variability for both methods. The measurements were processed as interclass correlation coefficient (ICC), Pearson and Spearman correlation, and Bland-Altman plots. RESULTS: PMSG created with a 3D template had higher interclass correlation coefficient values and Pearson/Spearman correlation than fenestrations created from CT measurements. The rate of fenestration alignment with the target vessel was higher for PMSG created with a 3D template (p=0.007). CONCLUSIONS: PMSGs created with a 3D template are more reliable and have better fenestration alignment with the target vessel than PMSGs created based on CT measurements.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Médicos , Humanos , Prótesis Vascular , Stents , Reproducibilidad de los Resultados , Diseño de Prótesis , Resultado del Tratamiento , Aneurisma de la Aorta Abdominal/cirugía , Tomografía Computarizada por Rayos X
8.
J Clin Med ; 11(18)2022 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-36143138

RESUMEN

Type II endoleak is one of the most common and problematic complications after endovascular aneurysm repair. It has been suggested that the inferior mesenteric artery (IMA) embolization could prevent further adverse events and postoperative complications. This article is a systematic review and meta-analysis following PRISMA guidelines. The Medline, PubMed, Embase, and Cochrane databases were used to identify studies that investigated the effect of IMA embolization on the occurrence of type II endoleaks and secondary interventions in a group of patients with abdominal aortic aneurysm who underwent EVAR compared with results after EVAR procedure without embolization. A random effects meta-analysis was performed. Of 3510 studies, 6 studies involving 659 patients were included. Meta-analysis of all studies showed that the rate of secondary interventions was smaller in patients with IMA embolization (OR, 0.17; SE, 0.45; 95% CI, 0.07 to 0.41; p < 0.01; I2 = 0%). The occurrence of type II endoleaks was also smaller in the embolization group (OR, 0.37; SE, 0.21; 95% CI, 0.25 to 0.57; p < 0.01; I2 = 16.20%). This meta-analysis suggests that IMA embolization correlates with lower rates of type II endoleaks and secondary interventions.

9.
Updates Surg ; 74(5): 1521-1531, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35986865

RESUMEN

Surgical procedures are often impeded by bleeding and/or leakage of body fluids. These complications cannot always be resolved by conventional surgical techniques. Hemopatch® is a hemostatic patch that also functions as a sealant. Here we document the effectiveness and safety of Hemopatch® for routine procedures of multiple surgical disciplines. To this end, we performed a prospective, multicenter, single-arm, observational registry study. Patients were eligible if they had received Hemopatch® during an open or minimally invasive procedure in one of these specialties: hepatobiliary, cardiovascular, urological, neurological/spinal, general, or lung surgery. Patients were excluded if they had a known hypersensitivity to bovine proteins or brilliant blue, intraoperative pulsatile or severe bleeding and/or infection at the target application site (TAS). The primary endpoint for intraoperative effectiveness was hemostasis assessed as the percentage of patients achieving hemostasis within 2 min and the percentage of patients achieving hemostasis without re-bleeding at the time of surgical closure. The registry enrolled 621 patients at 23 study sites in six European countries. Six hundred twenty patients had completed follow-up information. Hemostasis within 2 min was achieved at 463 (74.5%) of all 621 TASs. Hemostasis without re-bleeding was observed at 620 (99.8%) TASs. Adverse events were reported in 64 patients (10.3%). This Hemopatch® registry shows that Hemopatch® efficiently establishes hemostasis and sealing in a variety of surgical specialties, including minimally invasive procedures. Furthermore, we provide evidence for the safety of Hemopatch® across all the specialties included in the registry. This study is registered at clinicaltrials.gov: NCT03392662.


Asunto(s)
Hemostáticos , Especialidades Quirúrgicas , Animales , Pérdida de Sangre Quirúrgica , Bovinos , Hemostasis Quirúrgica/métodos , Hemostáticos/efectos adversos , Humanos , Estudios Prospectivos , Sistema de Registros , Resultado del Tratamiento
10.
Int J Mol Sci ; 23(7)2022 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-35408904

RESUMEN

Three-dimensionally-printed aortic templates are increasingly being used to aid in the modification of stent grafts in the treatment of urgent, complex aortic disorders, often of an emergency nature. The direct contact between the aortic template and the stent graft implies the necessity of complete sterility. Currently, the efficacy of sterilizing aortic templates and the effect of sterilization on the geometry of tubular aortic models are unknown. A complex case of aortic arch dissection was selected to prepare a 3D-printed aortic arch template, which was then manufactured in six popular printing materials: polylactic acid (PLA), nylon, polypropylene (PP), polyethylene terephthalate glycol (PETG), and a rigid and flexible photopolymer resin using fused deposition modeling (FDM) and stereolithography (SLA). The 3D models were contaminated with Geobacillus stearothermophilus broth and Bacillus atrophaeus. The sterilization was performed using three different methods: heat (105 °C and 121 °C), hydrogen peroxide plasma, and ethylene oxide gas. Before and after sterilization, the aortic templates were scanned using computed tomography to detect any changes in their morphology by comparing the dimensions. All sterilization methods were effective in the elimination of microorganisms. Steam sterilization in an autoclave at 121 °C caused significant deformation of the aortic templates made of PLA, PETG, and PP. The other materials had stable geometries, and changes during mesh comparisons were found to be submillimeter. Similarly, plasma, gas, and heat at 105 °C did not change the shapes of aortic templates observed macroscopically and using mesh analysis. All mean geometry differences were smaller than 0.5 mm. All sterilization protocols tested in our study were equally effective in destroying microorganisms; however, differences occurred in the ability to induce 3D object deformation. Sterilization at high temperatures deformed aortic templates composed of PLA, PETG, and PP. This method was suitable for nylon, flexible, and rigid resin-based models. Importantly, plasma and gas sterilization were appropriate for all tested printing materials, including PLA, PETG, PP, nylon, flexible and rigid resins. Moreover, sterilization of all the printed models using our novel protocol for steam autoclaving at 105 °C was also 100% effective, which could represent a significant advantage for health centers, which can therefore use one of the most popular and cheap methods of medical equipment disinfection for the sterilization of 3D models as well.


Asunto(s)
Disección Aórtica , Médicos , Desinfección , Humanos , Nylons , Poliésteres , Impresión Tridimensional , Vapor , Stents , Procedimientos Quirúrgicos Vasculares
11.
J Clin Med ; 11(8)2022 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-35456273

RESUMEN

The goal of this study was to describe the surgical results of physician-modified endografts (PMEG) utilizing a 3D aortic template in a center with no prior experience in complex endovascular aortic repairs. Forty-three patients underwent physician-modified graft stent implantation using a 3D aortic model. The inclusion criteria were juxtarenal and suprarenal aortic aneurysms, type IV thoracoabdominal aneurysms, and type IA endoleak after endovascular aortic repair. In asymptomatic patients, the diameter threshold for aneurysm repair was 5.5 cm in males and 5.0 cm in females. 3D aortic templates were prepared from the patient's computed tomography angiography scans and sterilized before use in the operating suite. Forty-three stent grafts were modified with the use of a 3D printing template. A total of 162 reinforced fenestrations (37 celiac, 43 right renal, 39 left renal, 43 superior mesenteric) with a mean of 3.8 per patient were performed. All PMEGs had a posterior reducing-diameter tie and a preloaded guidewire. The mean modification time was 86 ± 12 min. The mean follow-up was 14 ± 12 months. The 30-day mortality was 12%. During the follow-up period, the patency rate was 95% per the superior mesenteric artery, 93% per right renal artery, 95% per left renal artery, and 89% per celiac trunk. Twelve (28%) patients had endoleak, of which type I or III was present in 5 (12%) patients, and type II in 7 (16%). 3D printing can be successfully integrated into the physician's everyday practice of stent graft modification. However, the use of this approach in centers without experience performing complex aortic procedures results in worse surgical metrics than those previously reported.

12.
J Clin Med ; 11(4)2022 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-35207223

RESUMEN

The current stratification model of aneurysm rupture seems to be insufficient in some clinical cases. In our study, we determined the differences in wall structure between ruptured and unruptured aneurysms. We obtained computed tomography angiograms and categorized them into the following three groups, consisting of 49 patients each: the group with ruptured abdominal aortic aneurysms (rAAA), symptomatic (sAAA), and asymptomatic (aAAA). The three-dimensional AAA anatomy was digitally reconstructed for each patient through semi-automatically obtained segmentation, and each aneurysm was distinguished by the following three parameters: AFL (aneurysm flow lumen), ILT (intraluminal thrombus), and calcifications. The AFL volume was greater in rAAA compared with aAAA (p = 0.004), the ILT volume was greater in aAAA than in rAAA (p = 0.013), and the AFL/ILT surface ratio was bigger in rAAA than in aAAA (p < 0.001), sAAA than in aAAA (p = 0.033), and rAAA than in sAAA (p = 0.016). AFL/ILT surface*100 was defined as an independent predictive factor of rAAA to aAAA (OR 1.187; 95% CI 1.099-1.281), to sAAA (OR 1.045; 95% CI 1.004-1.087), and in sAAA vs. aAAA (OR 1.067; 95% CI 1.017-1.119). Consequently, the wall of rAAA differs significantly from unruptured aneurysms. The AFL/ILT surface ratio might indicate an increased risk of aneurysm rupture and the occurrence of symptoms in AAA.

13.
Quant Imaging Med Surg ; 12(2): 1385-1396, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35111632

RESUMEN

BACKGROUND: Advances in 3D printing technology allow us to continually find new medical applications. One of them is 3D printing of aortic templates to guide vascular surgeons or interventional radiologists to create fenestrations in the stent-graft surface for the implantation procedure called fenestrated endovascular aortic aneurysm repair. It is believed that the use of 3D printing significantly improves the quality of modified fenestrated stent-grafts. However, the accuracy and reliability of personalized 3D printed models of aortic templates are not well established. METHODS: Thirteen 3D printed templates of the visceral aorta and sixteen of the aortic arch and their corresponding computer tomography of angiography images were included in this accuracy study. The 3D models were scanned in the same conditions on computed tomography (CT) and evaluated by three physicians experienced in vascular CT assessment. Model and patient CT measurements were performed at key landmarks to maintain quality for stent-graft modification, including side branches and aortic diameters. CT-scanned aortic templates were segmented, aligned with sourced patient data, and evaluated for the Hausdorff matrix. Next, Bland-Altman plots determined the degree of agreement. RESULTS: The Intraclass Correlation Coefficients values were more than 0.9 for all measurements of aortic diameters and aortic branches diameter in all landmark locations. Therefore, the reliability of the aortic templates was considered excellent. The Bland-Altman plots analysis indicated measurement biases of 0.05 to 0.47 for aortic arch templates and 0.06 to 0.38 for reno-visceral aortic templates. The arithmetic mean of Hausdorff's mean distances of the aortic arch templates was 0.47 mm (SD =0.06) and ranged from 0.34 to 0.58. The mean metrics for abdominal models was 0.24 mm (SD =0.03) and ranged from 0.21 to 0.31. CONCLUSIONS: The printed models of 3D aortic templates are accurate and reliable, thus can be widely used in endovascular surgery and interventional radiology departments as aortic templates to guide the physician-modified fenestrated stent-graft fabrication.

14.
Materials (Basel) ; 14(23)2021 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-34885516

RESUMEN

In this paper, we have examined the influence of electroplated gold thickness on the thermal and electro-optical properties of mid-IR AlInAs/InGaAs, InP QCLs. The experimental results show a significant reduction of the temperature of QCL active region (AR) with increasing gold layer thickness. For QCLs with 5.0 µm gold thickness, we observed a 50% reduction of the active region temperature. An improvement of key electro-optical parameters, that is, threshold current density and maximum emitted power for structures with thick gold, was observed. The results of micro-Raman characterization show that the electroplated gold layer introduces only moderate compressive strain in top InP cladding, which is well below the critical value for the creation of misfit dislocations.

15.
Procedia Comput Sci ; 176: 2375-2383, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33042310

RESUMEN

Dynamically developing ICT technologies have become a tool to accelerate the creation of information societies around the world. Thanks to it, many traditional services have found a new digital space to function and thus achieve a global dimension. One example can be virtual museums, which provide access to their resources for every interested person having Internet connection. There is no doubt that the most spectacular and effective representation of digital museums are virtual walks, bringing, apart from cognitive aspects and good entertainment. In the era of the pandemic caused by the SARS-CoV-2 coronavirus and international quarantine which limits mobility, e-services gave humanity the opportunity and a substitute for normal existence. The interest in e-services has increased, which has been directly translated into increased informational awareness. Favourable conditions as well as relatively low costs and technical complexity of creating virtual walks have led the authors to adopt the following hypothesis: during the period of the quarantine caused by the SARS-CoV-2 coronavirus pandemic, museums are actively and dynamically developing virtual walks services. In the presented article, on the basis of research and analysis, the authors will test the hypothesis, as well as asses the level of virtual walks around monuments and museum centres in Poland.

16.
Proc Natl Acad Sci U S A ; 117(43): 26861-26867, 2020 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-33046636

RESUMEN

Synapsids are unique in having developed multirooted teeth and complex occlusions. These innovations evolved in at least two lineages of mammaliamorphs (Tritylodontidae and Mammaliaformes). Triassic fossils demonstrate that close to the origins of mammals, mammaliaform precursors were "experimenting" with tooth structure and function, resulting in novel patterns of occlusion. One of the most surprising examples of such adaptations is present in the haramiyidan clade, which differed from contemporary mammaliaforms in having two rows of cusps on molariform crowns adapted to omnivorous/herbivorous feeding. However, the origin of the multicusped tooth pattern present in haramiyidans has remained enigmatic. Here we describe the earliest-known mandibular fossil of a mammaliaform with double molariform roots and a crown with two rows of cusps from the Late Triassic of Greenland. The crown morphology is intermediate between that of morganucodontans and haramiyidans and suggests the derivation of the multicusped molariforms of haramiyidans from the triconodont molar pattern seen in morganucodontids. Although it is remarkably well documented in the fossil record, the significance of tooth root division in mammaliaforms remains enigmatic. The results of our biomechanical analyses (finite element analysis [FEA]) indicate that teeth with two roots can better withstand stronger mechanical stresses like those resulting from tooth occlusion, than teeth with a single root.


Asunto(s)
Evolución Biológica , Dentición , Fósiles , Mamíferos , Animales , Groenlandia
17.
Materials (Basel) ; 13(14)2020 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-32664660

RESUMEN

The precise determination of carrier concentration in doped semiconductor materials and nanostructures is of high importance. Many parameters of an operational device are dependent on the proper carrier concentration or its distribution in both the active area as well as in the passive parts as the waveguide claddings. Determining those in a nondestructive manner is, on the one hand, demanded for the fabrication process efficiency, but on the other, challenging experimentally, especially for complex multilayer systems. Here, we present the results of carrier concentration determination in In0.53Ga0.47As layers, designed to be a material forming quantum cascade laser active areas, using a direct and contactless method utilizing the Berreman effect, and employing Fourier-transform infrared (FTIR) spectroscopy. The results allowed us to precisely determine the free carrier concentration versus changes in the nominal doping level and provide feedback regarding the technological process by indicating the temperature adjustment of the dopant source.

18.
J Ophthalmol ; 2020: 8326207, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32280535

RESUMEN

PURPOSE: Carotid endarterectomy (CEA) is considered an effective therapeutic method for improving ocular circulation. The choroid is a predominantly vascular tissue; thus, systemic and local vascular alterations may influence its morphology and function. The aim of the current study was to analyse changes in choroidal thickness and volume in patients with significant internal carotid artery stenosis (ICAS) before and after unilateral CEA. METHODS: The 42 eyes of the 21 asymptomatic patients included in the study were divided into two groups: those ipsilateral (EIE) and those contralateral (ECE) to CEA. All participants underwent a complete ophthalmologic examination, including enhanced depth imaging-optical coherence tomography (EDI-OCT). A comparative analysis of subfoveal thickness (CT) and choroidal volume (CV) measured in nine Early Treatment of Diabetic Retinopathy Study (ETDRS) subfields at baseline, on the 2nd day after CEA, and in the 3rd month after CEA was performed. RESULTS: In the EIE and ECE groups, no significant differences in either CT or CV values before and on the 2nd day after the CEA were observed. In the EIE group, a significant increase in CT and CV in the 3rd month after CEA compared to baseline was noted in the specific ETDRS region. Changes in CT and CV after surgery were positively correlated with the participants' physical activity status and diastolic blood pressure and negatively correlated with the participants' age and smoking status. Additionally, the analysis of changes in CV after CEA showed a positive correlation between the EIE and ECE groups. CONCLUSIONS: CT and CV fluctuations in the central and perifoveal areas visualized with EDI-OCT enabled the observation of the processes of tissue adaptation to variable blood flow conditions.

19.
J Clin Med ; 9(4)2020 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-32290189

RESUMEN

Technical errors have an impact on the results of surgical lower limb revascularization. Use of ultrasound scanning or angiography on the operating table is inconvenient and, in case of angiography, carries a certain risk of radiation and contrast exposure. A simpler method of screening for errors is required. This study assessed the accuracy of a new simple hydrostatic bypass flow technique during surgical limb revascularization. In all, 885 patients were included in the retrospective study. All were treated for Chronic Limb-Threatening Ischemia (CLTI) with a femoropopliteal bypass. Preoperatively, the radiological Vascular Surgery/International Society of Cardiovascular Surgery (SVS/ISCVS) score was used to assess the complexity of the anatomical changes. The surgeon made a subjective runoff assessment for every surgery. In 267 cases, the hydrostatic bypass flow (HBF) technique was used, and, in 66 cases, a digital subtraction angiography (DSA) was used. In each case, a postoperative Doppler ultrasound (DUS) examination was performed following the HBF. Good early results were achieved in 89.46%, and 154 errors (17.4%) were detected (85 were detected on the operating table, including 57 technical errors). Independent efficacy in error detection was proven with a postoperative Doppler examination (Aera Under Curve (AUC) = 0.89; criterion mid-graft peak systolic velocity (PSV) <24 cm/s, p = 0.00001) and hydrostatic bypass flow (AUC = 0.71, criterion HBF < 53 mL/min, p = 0.00001) during surgery. The hydrostatic bypass flow technique is an effective intraoperative screening method in bypass surgery. Algorithmic use of HBF, DSA if needed, and DUS postoperatively improves the outcome. HBF sufficiently reduced the need for on-table angiography.

20.
Rev Cardiovasc Med ; 21(1): 129-137, 2020 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-32259912

RESUMEN

There have been indisputable developments in techniques for stabilizing acute aortic syndromes. However, aneurysmal degeneration following aortic dissection remains a problem to be solved. The currently available treatment options for aortic dissection still fail to take into account the known risk factors for aneurysmal degeneration. This is why we introduced a new approach to treating patients with an aortic dissection, called Complete Entry and Re-entry Neutralization (CERN). This is our initial report on the promising interim results. MATERIAL AND METHODS: 68 patients qualified for endovascular treatment of an acute or chronic aortic dissection. Computed tomography was performed post-operatively to assess aortic remodeling after 1/6/12/24/36 months. RESULTS: the 30-day mortality rate was 4.4%. In 29 cases (43%) unfavorable remodeling was noted in the follow-up. The most important factors leading to unfavorable remodeling were: uncovered re-entry tear including the infra-renal segment, no relining of dissection membranes and insufficient coverage of the descending aorta. We analyzed these factors to develop the CERN protocol. This concept consists of six basic rules: A. cover all entry tears, B. amplify the BMS radial force, C. use the STABILISE technique, D. consider using thrombus plugs, E. avoid stenting the visceral branches, F. spare the intercostal and lumbar side branches. CERN improves the rate of favorable remodeling from 25% to 85% (P = 0.0067). CONCLUSION: Introduction of the Complete Entry and Re-entry Neutralization protocol improves the rate of favorable remodeling following endovascular treatment of aortic dissection in mid-term follow-up in patients with diffused aortic dissection.


Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Adulto , Anciano , Anciano de 80 o más Años , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Disección Aórtica/fisiopatología , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/mortalidad , Aneurisma de la Aorta/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Estudios de Casos y Controles , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Remodelación Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...