Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biosensors (Basel) ; 13(2)2023 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-36832045

RESUMEN

Diagnostics based on the determination of biomarkers in body fluids will be more successful when several biomarkers are determined. A multiple-array SPRi biosensor for the simultaneous determination of CA125, HE4, CEA, IL-6 and aromatase has been developed. Five individual biosensors were placed on the same chip. Each of them consisted of a suitable antibody covalently immobilized onto a gold chip surface via a cysteamine linker by means of the NHS/EDC protocol. The biosensor for IL-6 works in the pg mL-1 range, that for CA125 in the µg mL-1 range, and the other three within the ng mL-1 range; these are ranges suitable for the determination of biomarkers in real samples. The results obtained with the multiple-array biosensor are very similar to those obtained with a single biosensor. The applicability of the multiple biosensor was demonstrated using several examples of plasma from patients suffering from ovarian cancer and endometrial cyst. The average precision was 3.4% for the determination of CA125, 3.5% for HE4, 5.0% for CEA and IL-6, and 7.6% for aromatase. The simultaneous determination of several biomarkers may be an excellent tool for the screening of the population for earlier detection of diseases.


Asunto(s)
Aromatasa , Técnicas Biosensibles , Femenino , Humanos , Biomarcadores de Tumor , Interleucina-6 , Proteína 2 de Dominio del Núcleo de Cuatro Disulfuros WAP , Técnicas Biosensibles/métodos
2.
Biosensors (Basel) ; 12(6)2022 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-35735559

RESUMEN

Interleukin-6 (IL-6) is a biomarker of inflammation, the advanced stage of COVID-19, and several cancers, including ovarian cancer. Two biosensors for the determination of IL-6 in blood plasma by array SPRi have been developed. One of these biosensors consists of the mouse monoclonal anti-IL-6 antibody as the receptor immobilized via the cysteamine linker. The second contains galiellalactone as the receptor, being an inhibitor specific for IL-6, immobilized via octadecanethiol (ODM) as the linker. Both biosensors are specific for IL-6. The biosensor with the antibody as the receptor gives a linear analytical response between 3 (LOQ) and 20 pg mL-1 and has a precision between 8% and 9.8% and recovery between 97% and 107%, depending on the IL-6 concentration. The biosensor with galiellalactone as the receptor gives a linear analytical response between 1.1 (LOQ) and 20 pg mL-1, and has a precision between 3.5% and 9.3% and recovery between 101% and 105%, depending on IL-6 concentration. Both biosensors were validated. Changes in IL-6 concentration in blood plasma before and after resection of ovarian tumor and endometrial cyst, as determined by the two developed biosensors, are given as an example of a real clinical application.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Neoplasias Ováricas , Animales , Femenino , Humanos , Interleucina-6 , Ratones , Plasma
3.
Sensors (Basel) ; 21(10)2021 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-34065481

RESUMEN

Human epididymis protein 4 (HE4) is an ovarian cancer marker. Various cut-off values of the marker in blood are recommended, depending on the method used for its determination. An alternative biosensor for HE4 determination in blood plasma has been developed. It consists of rabbit polyclonal antibody against HE4, covalently attached to a gold chip via cysteamine linker. The biosensor is used with the non-fluidic array SPRi technique. The linear range of the analytical signal response was found to be 2-120 pM, and the biosensor can be used for the determination of the HE4 marker in the plasma of both healthy subjects and ovarian cancer patients after suitable dilution with a PBS buffer. Precision (6-10%) and recovery (101.8-103.5%) were found to be acceptable, and the LOD was equal to 2 pM. The biosensor was validated by the parallel determination of a series of plasma samples from ovarian cancer patients using the Elecsys HE4 test and the developed biosensor, with a good agreement of the results (a Pearson coefficient of 0.989). An example of the diagnostic application of the developed biosensor is given-the influence of ovarian tumor resection on the level of HE4 in blood serum.


Asunto(s)
Técnicas Biosensibles , Neoplasias Ováricas , Proteína 2 de Dominio del Núcleo de Cuatro Disulfuros WAP/análisis , Biomarcadores de Tumor/análisis , Femenino , Humanos , Neoplasias Ováricas/diagnóstico , Plasma
4.
Anal Biochem ; 609: 113964, 2020 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-32979366

RESUMEN

Carcinoembryonic antigen (CEA) is one of the biomarkers most commonly used to determine tumor activity. In this work, a Surface Plasmon Resonance imaging (SPRi) immunosensor was developed. The immunosensor consists of a cysteamine linker attached to a gold chip and mouse monoclonal anti-CEA antibody bonded by the "EDC/NHS protocol". The formation of successive immunosensor layers was confirmed by AFM measurements. The concentration of the antibody was optimized. The linear response range of the developed immunosensor is between 0.40 and 20 ng mL-1, and it is suitable for CEA measurement in both blood cancer patients and healthy individuals. Only 3 µL of serum or plasma sample is required, and no preconcentration is used. The method has a precision of 2-16%, a recovery of 101-104% depending on CEA concentration, a detection limit of 0.12 ng mL-1 and a quantification limit of 0.40 ng mL-1. The method is selective (with respect to albumin, leptin, interleukin 6, metalloproteinase-1, metallopeptidase inhibitor 1 and CA 125/MUC16) and it was validated by comparison with the standard electrochemiluminescence method on a series of colorectal cancer blood samples.


Asunto(s)
Antígeno Carcinoembrionario/sangre , Resonancia por Plasmón de Superficie/métodos , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/inmunología , Biomarcadores de Tumor/sangre , Antígeno Ca-125/química , Antígeno Carcinoembrionario/inmunología , Neoplasias Colorrectales/diagnóstico , Humanos , Inmunoensayo , Leptina/química , Límite de Detección , Proteínas de la Membrana/química , Inhibidor Tisular de Metaloproteinasa-1/química
5.
Gynecol Endocrinol ; 36(2): 104-108, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31607185

RESUMEN

Endometriosis is a common disease in women of reproduction age. It causes pain and difficulty in getting pregnant. However the exact causes of infertility associated with endometriosis still remain controversial. The treatment of endometriosis consists of medical treatment of pain as well as medical and surgical treatment of infertility caused by endometriosis and assisted reproduction techniques. Since the treatment of endometriosis is often connected with diminishing ovarian reserve, the techniques for ovarian tissue preservation and oocyte and embryo freezing are used to maintain the ability for childbearing.


Asunto(s)
Endometriosis/diagnóstico , Endometriosis/terapia , Infertilidad Femenina/diagnóstico , Infertilidad Femenina/terapia , Femenino , Preservación de la Fertilidad , Procedimientos Quirúrgicos Ginecológicos , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...