Ann Intensive Care ; 7(1): 59, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28589534

RESUMEN

When used as a driving gas during NIV in hypercapnic COPD exacerbation, a helium-oxygen (He/O2) mixture reduces the work of breathing and gas trapping. The potential for He/O2 to reduce the rate of NIV failure leading to intubation and invasive mechanical ventilation has been evaluated in several RCTs. The goal of this meta-analysis is to assess the effect of NIV driven by He/O2 compared to air/O2 on patient-centered outcomes in hypercapnic COPD exacerbation. Relevant RCTs were searched using standard procedures. The main endpoint was the rate of NIV failure. The effect size was computed by a fixed-effect model, and estimated as odds ratio (OR) with 95% confidence interval (CI). Additional endpoints were ICU mortality, NIV-related side effects, and the length and costs of ICU stay. Three RCTs fulfilled the selection criteria and enrolled a total of 772 patients (386 patients received He/O2 and 386 received air/O2). Pooled analysis showed no difference in the rate of NIV failure when using He/O2 mixture compared to air/O2: 17 vs 19.7%, respectively; OR 0.84, 95% CI 0.58-1.22; p = 0.36; I 2 for heterogeneity = 0%, and no publication bias. ICU mortality was also not different: OR 0.8, 95% CI 0.45-1.4; p = 0.43; I 2 = 5%. However, He/O2 was associated with less NIV-related adverse events (OR 0.56, 95% CI 0.4-0.8, p = 0.001), and a shorter length of ICU stay (difference in means = -1.07 day, 95% CI -2.14 to -0.004, p = 0.049). Total hospital costs entailed by hospital stay and NIV gas were not different: difference in means = -279$, 95% CI -2052-1493, p = 0.76. Compared to air/O2, He/O2 does not reduce the rate of NIV failure in hypercapnic COPD exacerbation. It is, however, associated with a lower incidence of NIV-related adverse events and a shortening of ICU length of stay with no increase in hospital costs.

2.
Am J Respir Crit Care Med ; 195(7): 871-880, 2017 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-27736154

RESUMEN

RATIONALE: During noninvasive ventilation (NIV) for chronic obstructive pulmonary disease (COPD) exacerbations, helium/oxygen (heliox) reduces the work of breathing and hypercapnia more than air/O2, but its impact on clinical outcomes remains unknown. OBJECTIVES: To determine whether continuous administration of heliox for 72 hours, during and in-between NIV sessions, was superior to air/O2 in reducing NIV failure (25-15%) in severe hypercapnic COPD exacerbations. METHODS: This was a prospective, randomized, open-label trial in 16 intensive care units (ICUs) and 6 countries. Inclusion criteria were COPD exacerbations with PaCO2 ≥ 45 mm Hg, pH ≤ 7.35, and at least one of the following: respiratory rate ≥ 25/min, PaO2 ≤ 50 mm Hg, and oxygen saturation (arterial [SaO2] or measured by pulse oximetry [SpO2]) ≤ 90%. A 6-month follow-up was performed. MEASUREMENTS AND MAIN RESULTS: The primary endpoint was NIV failure (intubation or death without intubation in the ICU). The secondary endpoints were physiological parameters, duration of ventilation, duration of ICU and hospital stay, 6-month recurrence, and rehospitalization rates. The trial was stopped prematurely (445 randomized patients) because of a low global failure rate (NIV failure: air/O2 14.5% [n = 32]; heliox 14.7% [n = 33]; P = 0.97, and time to NIV failure: heliox group 93 hours [n = 33], air/O2 group 52 hours [n = 32]; P = 0.12). Respiratory rate, pH, PaCO2, and encephalopathy score improved significantly faster with heliox. ICU stay was comparable between the groups. In patients intubated after NIV failed, patients on heliox had a shorter ventilation duration (7.4 ± 7.6 d vs. 13.6 ± 12.6 d; P = 0.02) and a shorter ICU stay (15.8 ± 10.9 d vs. 26.7 ± 21.0 d; P = 0.01). No difference was observed in ICU and 6-month mortality. CONCLUSIONS: Heliox improves respiratory acidosis, encephalopathy, and the respiratory rate more quickly than air/O2 but does not prevent NIV failure. Overall, the rate of NIV failure was low. Clinical trial registered with www.clinicaltrials.gov (NCT 01155310).


Asunto(s)
Helio/uso terapéutico , Ventilación no Invasiva/métodos , Oxígeno/uso terapéutico , Enfermedad Pulmonar Obstructiva Crónica/terapia , Anciano , Análisis de los Gases de la Sangre/estadística & datos numéricos , Femenino , Hospitalización/estadística & datos numéricos , Humanos , Tiempo de Internación/estadística & datos numéricos , Masculino , Estudios Prospectivos , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Recurrencia , Resultado del Tratamiento
3.
J Emerg Med ; 50(1): 55-60, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26281812

RESUMEN

BACKGROUND: Wild garlic and related plants are increasingly sought after by fans of natural products. They can be confused with other plants containing colchicine and cause potentially fatal intoxications. CASE REPORT: We report a case of accidental poisoning by Colchicum autumnale, which was mistaken for wild garlic (Allium ursinum). The patient initially presented with mild gastrointestinal symptoms, but progressed rapidly to agranulocytosis, paraparesis, and delirium before the causative agent was identified. The laboratory tests revealed rhabdomyolysis, coagulopathy, alteration of liver tests, and prerenal azotemia. Botanical examination confirmed the incriminated plant (Colchicum autumnale). Serum and urine analysis confirmed the presence of colchicine. The patient required intensive support therapy, and she fully recovered within 8 weeks. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Colchicine poisoning should be considered in the differential diagnosis of patients presenting with gastroenteritis after ingestion of wild garlic.


Asunto(s)
Colchicum/envenenamiento , Insuficiencia Multiorgánica/etiología , Extractos Vegetales/envenenamiento , Allium , Femenino , Humanos , Persona de Mediana Edad
4.
Ann Intensive Care ; 5: 2, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25852962

RESUMEN

BACKGROUND: In acute respiratory failure, arterial blood gas analysis (ABG) is used to diagnose hypercapnia. Once non-invasive ventilation (NIV) is initiated, ABG should at least be repeated within 1 h to assess PaCO2 response to treatment in order to help detect NIV failure. The main aim of this study was to assess whether measuring end-tidal CO2 (EtCO2) with a dedicated naso-buccal sensor during NIV could predict PaCO2 variation and/or PaCO2 absolute values. The additional aim was to assess whether active or passive prolonged expiratory maneuvers could improve the agreement between expiratory CO2 and PaCO2. METHODS: This is a prospective study in adult patients suffering from acute hypercapnic respiratory failure (PaCO2 ≥ 45 mmHg) treated with NIV. EtCO2 and expiratory CO2 values during active and passive expiratory maneuvers were measured using a dedicated naso-buccal sensor and compared to concomitant PaCO2 values. The agreement between two consecutive values of EtCO2 (delta EtCO2) and two consecutive values of PaCO2 (delta PaCO2) and between PaCO2 and concomitant expiratory CO2 values was assessed using the Bland and Altman method adjusted for the effects of repeated measurements. RESULTS: Fifty-four datasets from a population of 11 patients (8 COPD and 3 non-COPD patients), were included in the analysis. PaCO2 values ranged from 39 to 80 mmHg, and EtCO2 from 12 to 68 mmHg. In the observed agreement between delta EtCO2 and deltaPaCO2, bias was -0.3 mmHg, and limits of agreement were -17.8 and 17.2 mmHg. In agreement between PaCO2 and EtCO2, bias was 14.7 mmHg, and limits of agreement were -6.6 and 36.1 mmHg. Adding active and passive expiration maneuvers did not improve PaCO2 prediction. CONCLUSIONS: During NIV delivered for acute hypercapnic respiratory failure, measuring EtCO2 using a dedicating naso-buccal sensor was inaccurate to predict both PaCO2 and PaCO2 variations over time. Active and passive expiration maneuvers did not improve PaCO2 prediction. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01489150.

5.
Respir Care ; 59(10): 1463-75, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25118306

RESUMEN

BACKGROUND: Using a bench test model, we investigated the hypothesis that neonatal and/or adult ventilators equipped with neonatal/pediatric modes currently do not reliably administer pressure support (PS) in neonatal or pediatric patient groups in either the absence or presence of air leaks. METHODS: PS was evaluated in 4 neonatal and 6 adult ventilators using a bench model to evaluate triggering, pressurization, and cycling in both the absence and presence of leaks. Delivered tidal volumes were also assessed. Three patients were simulated: a preterm infant (resistance 100 cm H2O/L/s, compliance 2 mL/cm H2O, inspiratory time of the patient [TI] 400 ms, inspiratory effort 1 and 2 cm H2O), a full-term infant (resistance 50 cm H2O/L/s, compliance 5 mL/cm H2O, TI 500 ms, inspiratory effort 2 and 4 cm H2O), and a child (resistance 30 cm H2O/L/s, compliance 10 mL/cm H2O, TI 600 ms, inspiratory effort 5 and 10 cm H2O). Two PS levels were tested (10 and 15 cm H2O) with and without leaks and with and without the leak compensation algorithm activated. RESULTS: Without leaks, only 2 neonatal ventilators and one adult ventilator had trigger delays under a given predefined acceptable limit (1/8 TI). Pressurization showed high variability between ventilators. Most ventilators showed TI in excess high enough to seriously impair patient-ventilator synchronization (> 50% of the TI of the subject). In some ventilators, leaks led to autotriggering and impairment of ventilation performance, but the influence of leaks was generally lower in neonatal ventilators. When a noninvasive ventilation algorithm was available, this was partially corrected. In general, tidal volume was calculated too low by the ventilators in the presence of leaks; the noninvasive ventilation algorithm was able to correct this difference in only 2 adult ventilators. CONCLUSIONS: No ventilator performed equally well under all tested conditions for all explored parameters. However, neonatal ventilators tended to perform better in the presence of leaks. These findings emphasize the need to improve algorithms for assisted ventilation modes to better deal with situations of high airway resistance, low pulmonary compliance, and the presence of leaks.


Asunto(s)
Unidades de Cuidados Intensivos , Evaluación de la Tecnología Biomédica , Ventiladores Mecánicos , Adolescente , Adulto , Niño , Preescolar , Seguridad de Equipos , Femenino , Humanos , Lactante , Recién Nacido , Recien Nacido Prematuro , Masculino , Respiración con Presión Positiva , Mecánica Respiratoria , Volumen de Ventilación Pulmonar
6.
Ann Intensive Care ; 4(1): 2, 2014 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-24484902

RESUMEN

BACKGROUND: Observational studies on mechanical ventilation (MV) show practice variations across ICUs. We sought to determine, with a case-vignette study, the heterogeneity of processes of care in ICUs focusing on mechanical ventilation procedures, and whether organizational patterns or physician characteristics influence practice variations. METHODS: We conducted a cross-sectional multicenter study using the case-vignette methodology. Descriptive analyses were calculated for each organizational pattern and respondent characteristics. An Index of Qualitative Variation (IQV, from 0, no heterogeneity, to a maximum of 1) was calculated. RESULTS: Forty ICUs from France (N = 33) and Switzerland (N = 7) participated; 396 physicians answered our case-vignettes. There was major heterogeneity of management processes related to MV within and across centers (mean IQV per center 0.51, SD 0.09). We observed the lowest variability (mean IQV per question < 0.4) for questions related to intubation procedure, ventilation of acute respiratory distress syndrome and the use of the semirecumbent position. We observed a high variability (mean IQV per question > 0.6) for questions related to management of endotracheal tube or suctioning, management of sedation and analgesia, and respect of autonomy. Heterogeneity was independent of respondent characteristics and of the presence of written procedures. There was a correlation between the processes associated with the highest variability (mean IQV per question > 0.6) and the annual volume of ICU admission (r = 0.32 (0.01 to 0.58)) and MV (r = 0.38 (0.07 to 0.63)). Within ICUs there was a large heterogeneity regarding knowledge of a local written procedure. CONCLUSIONS: Large clinical practice variations were found among ICUs. High volume centers were more likely to have heterogeneous practices. The presence of a local written procedure or respondent characteristics did not influence practice variation.

7.
Crit Care ; 17(6): 1015, 2013 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-24252458

RESUMEN

Although severe patient-ventilator asynchrony is frequent during invasive and non-invasive mechanical ventilation, diagnosing such asynchronies usually requires the presence at the bedside of an experienced clinician to assess the tracings displayed on the ventilator screen, thus explaining why evaluating patient-ventilator interaction remains a challenge in daily clinical practice. In the previous issue of Critical Care, Sinderby and colleagues present a new automated method to detect, quantify, and display patient-ventilator interaction. In this validation study, the automatic method is as efficient as experts in mechanical ventilation. This promising system could help clinicians extend their knowledge about patient-ventilator interaction and further improve assisted mechanical ventilation.


Asunto(s)
Soporte Ventilatorio Interactivo/métodos , Humanos
8.
Pediatr Crit Care Med ; 14(8): e357-64, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23863816

RESUMEN

OBJECTIVES: To document the prevalence of asynchrony events during noninvasive ventilation in pressure support in infants and in children and to compare the results with neurally adjusted ventilatory assist. DESIGN: Prospective randomized cross-over study in children undergoing noninvasive ventilation. SETTING: The study was performed in a PICU. PATIENTS: From 4 weeks to 5 years. INTERVENTIONS: Two consecutive ventilation periods (pressure support and neurally adjusted ventilatory assist) were applied in random order. During pressure support (PS), three levels of expiratory trigger (ETS) setting were compared: initial ETS (PSinit), and ETS value decreased and increased by 15%. Of the three sessions, the period allowing for the lowest number of asynchrony events was defined as PSbest. Neurally adjusted ventilator assist level was adjusted to match the maximum airway pressure during PSinit. Positive end-expiratory pressure was the same during pressure support and neurally adjusted ventilator assist. Asynchrony events, trigger delay, and cycling-off delay were quantified for each period. RESULTS: Six infants and children were studied. Trigger delay was lower with neurally adjusted ventilator assist versus PSinit and PSbest (61 ms [56-79] vs 149 ms [134-180] and 146 ms [101-162]; p = 0.001 and 0.02, respectively). Inspiratory time in excess showed a trend to be shorter during pressure support versus neurally adjusted ventilator assist. Main asynchrony events during PSinit were autotriggering (4.8/min [1.7-12]), ineffective efforts (9.9/min [1.7-18]), and premature cycling (6.3/min [3.2-18.7]). Premature cycling (3.4/min [1.1-7.7]) was less frequent during PSbest versus PSinit (p = 0.059). The asynchrony index was significantly lower during PSbest versus PSinit (40% [28-65] vs 65.5% [42-76], p < 0.001). With neurally adjusted ventilator assist, all types of asynchronies except double triggering were reduced. The asynchrony index was lower with neurally adjusted ventilator assist (2.3% [0.7-5] vs PSinit and PSbest, p < 0.05 for both comparisons). CONCLUSION: Asynchrony events are frequent during noninvasive ventilation with pressure support in infants and in children despite adjusting the cycling-off criterion. Compared with pressure support, neurally adjusted ventilator assist allows improving patient-ventilator synchrony by reducing trigger delay and the number of asynchrony events. Further studies should determine the clinical impact of these findings.


Asunto(s)
Unidades de Cuidado Intensivo Pediátrico , Soporte Ventilatorio Interactivo/métodos , Respiración con Presión Positiva/métodos , Niño , Preescolar , Estudios Cruzados , Femenino , Humanos , Lactante , Soporte Ventilatorio Interactivo/efectos adversos , Masculino , Pacientes , Respiración con Presión Positiva/efectos adversos , Prevalencia , Estudios Prospectivos , Respiración , Suiza
9.
Pediatr Crit Care Med ; 14(7): e316-25, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23842584

RESUMEN

OBJECTIVES: To document and compare the prevalence of asynchrony events during invasive-assisted mechanical ventilation in pressure support mode and in neurally adjusted ventilatory assist in children. DESIGN: Prospective, randomized, and crossover study. SETTING: Pediatric and Neonatal Intensive Care Unit, University Hospital of Geneva, Switzerland. PATIENTS: Intubated and mechanically ventilated children, between 4 weeks and 5 years old. INTERVENTIONS: Two consecutive ventilation periods (pressure support and neurally adjusted ventilatory assist) were applied in random order. During pressure support, three levels of expiratory trigger setting were compared: expiratory trigger setting as set by the clinician in charge (PSinit), followed by a 10% (in absolute values) increase and decrease of the clinician's expiratory trigger setting. The pressure support session with the least number of asynchrony events was defined as PSbest. Therefore, three periods were compared: PSinit, PSbest, and neurally adjusted ventilatory assist. Asynchrony events, trigger delay, and inspiratory time in excess were quantified for each of them. MEASUREMENTS AND MAIN RESULTS: Data from 19 children were analyzed. Main asynchrony events during PSinit were autotriggering (3.6 events/min [0.7-8.2]), ineffective efforts (1.2/min [0.6-5]), and premature cycling (3.5/min [1.3-4.9]). Their number was significantly reduced with PSbest: autotriggering 1.6/min (0.2-4.9), ineffective efforts 0.7/min (0-2.6), and premature cycling 2/min (0.1-3.1), p < 0.005 for each comparison. The median asynchrony index (total number of asynchronies/triggered and not triggered breaths ×100) was significantly different between PSinit and PSbest: 37.3% [19-47%] and 29% [24-43%], respectively, p < 0.005). With neurally adjusted ventilatory assist, all types of asynchrony events except double-triggering and inspiratory time in excess were significantly reduced resulting in an asynchrony index of 3.8% (2.4-15%) (p < 0.005 compared to PSbest). CONCLUSIONS: Asynchrony events are frequent during pressure support in children despite adjusting the cycling off criteria. Neurally adjusted ventilatory assist allowed for an almost ten-fold reduction in asynchrony events. Further studies should determine the clinical impact of these findings.


Asunto(s)
Unidades de Cuidado Intensivo Pediátrico , Respiración Artificial/efectos adversos , Respiración Artificial/métodos , Preescolar , Estudios Cruzados , Femenino , Humanos , Lactante , Intubación Intratraqueal , Masculino , Estudios Prospectivos
10.
EuroIntervention ; 8(12): 1419-27, 2013 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-23680957

RESUMEN

AIMS: Pulmonary embolism (PE) associated with haemodynamic instability has exceedingly high mortality. While intravenous thrombolysis is considered the therapy of choice, percutaneous mechanical thrombectomy may represent an alternative treatment. METHODS AND RESULTS: The impact of AngioJet® rheolytic thrombectomy (RT) in PE associated with cardiogenic shock was assessed in a single-centre prospective pilot study. Ten consecutive PE patients in cardiogenic shock were included in the study. Six patients had thrombolysis contraindications, eight were intubated before the RT procedure and six had experienced cardiac arrest prior to the RT procedure. The RT procedure was technically successful in all cases. The Miller index improved from 25 to 20 (p=0.002). The shock index decreased from 1.22 to 0.9 (p=0.129). Thrombolytic agents were administered during or after the procedure in four patients because of progressive clinical deterioration. Seven patients died in the first 24 hours: two from multi-organ failure, one from post-anoxic cerebral oedema, and four from progressive right heart failure. The three survivors had favourable outcomes at one year. CONCLUSIONS: This study suggests that the AngioJet® RT procedure may be safely performed in PE patients with cardiogenic shock. However, despite angiographic and haemodynamic improvements, the procedure does not appear to influence the dismal prognosis of these high-risk patients.


Asunto(s)
Embolia Pulmonar/terapia , Choque Cardiogénico/terapia , Trombectomía/instrumentación , Anciano , Anciano de 80 o más Años , Edema Encefálico/etiología , Edema Encefálico/mortalidad , Diseño de Equipo , Estudios de Factibilidad , Femenino , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/mortalidad , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia Multiorgánica/etiología , Insuficiencia Multiorgánica/mortalidad , Proyectos Piloto , Estudios Prospectivos , Embolia Pulmonar/complicaciones , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/mortalidad , Embolia Pulmonar/fisiopatología , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Choque Cardiogénico/mortalidad , Choque Cardiogénico/fisiopatología , Suiza , Trombectomía/efectos adversos , Trombectomía/mortalidad , Terapia Trombolítica , Factores de Tiempo , Resultado del Tratamiento
11.
J Clin Monit Comput ; 27(1): 61-70, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23015365

RESUMEN

Neurally adjusted ventilatory assist (NAVA) is a ventilation assist mode that delivers pressure in proportionality to electrical activity of the diaphragm (Eadi). Compared to pressure support ventilation (PS), it improves patient-ventilator synchrony and should allow a better expression of patient's intrinsic respiratory variability. We hypothesize that NAVA provides better matching in ventilator tidal volume (Vt) to patients inspiratory demand. 22 patients with acute respiratory failure, ventilated with PS were included in the study. A comparative study was carried out between PS and NAVA, with NAVA gain ensuring the same peak airway pressure as PS. Robust coefficients of variation (CVR) for Eadi and Vt were compared for each mode. The integral of Eadi (ʃEadi) was used to represent patient's inspiratory demand. To evaluate tidal volume and patient's demand matching, Range90 = 5-95 % range of the Vt/ʃEadi ratio was calculated, to normalize and compare differences in demand within and between patients and modes. In this study, peak Eadi and ʃEadi are correlated with median correlation of coefficients, R > 0.95. Median ʃEadi, Vt, neural inspiratory time (Ti_ ( Neural )), inspiratory time (Ti) and peak inspiratory pressure (PIP) were similar in PS and NAVA. However, it was found that individual patients have higher or smaller ʃEadi, Vt, Ti_ ( Neural ), Ti and PIP. CVR analysis showed greater Vt variability for NAVA (p < 0.005). Range90 was lower for NAVA than PS for 21 of 22 patients. NAVA provided better matching of Vt to ʃEadi for 21 of 22 patients, and provided greater variability Vt. These results were achieved regardless of differences in ventilatory demand (Eadi) between patients and modes.


Asunto(s)
Diafragma/fisiología , Electromiografía , Soporte Ventilatorio Interactivo/métodos , Respiración con Presión Positiva/métodos , Insuficiencia Respiratoria/terapia , Volumen de Ventilación Pulmonar/fisiología , Anciano , Humanos , Inhalación/fisiología , Persona de Mediana Edad , Modelos Biológicos , Estudios Prospectivos , Insuficiencia Respiratoria/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
13.
Intensive Care Med ; 38(10): 1624-31, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22885649

RESUMEN

PURPOSE: To determine if, compared to pressure support (PS), neurally adjusted ventilatory assist (NAVA) reduces patient-ventilator asynchrony in intensive care patients undergoing noninvasive ventilation with an oronasal face mask. METHODS: In this prospective interventional study we compared patient-ventilator synchrony between PS (with ventilator settings determined by the clinician) and NAVA (with the level set so as to obtain the same maximal airway pressure as in PS). Two 20-min recordings of airway pressure, flow and electrical activity of the diaphragm during PS and NAVA were acquired in a randomized order. Trigger delay (T(d)), the patient's neural inspiratory time (T(in)), ventilator pressurization duration (T(iv)), inspiratory time in excess (T(iex)), number of asynchrony events per minute and asynchrony index (AI) were determined. RESULTS: The study included 13 patients, six with COPD, and two with mixed pulmonary disease. T(d) was reduced with NAVA: median 35 ms (IQR 31-53 ms) versus 181 ms (122-208 ms); p = 0.0002. NAVA reduced both premature and delayed cyclings in the majority of patients, but not the median T(iex) value. The total number of asynchrony events tended to be reduced with NAVA: 1.0 events/min (0.5-3.1 events/min) versus 4.4 events/min (0.9-12.1 events/min); p = 0.08. AI was lower with NAVA: 4.9 % (2.5-10.5 %) versus 15.8 % (5.5-49.6 %); p = 0.03. During NAVA, there were no ineffective efforts, or late or premature cyclings. PaO(2) and PaCO(2) were not different between ventilatory modes. CONCLUSION: Compared to PS, NAVA improved patient ventilator synchrony during noninvasive ventilation by reducing T(d) and AI. Moreover, with NAVA, ineffective efforts, and late and premature cyclings were absent.


Asunto(s)
Soporte Ventilatorio Interactivo/métodos , Ventilación no Invasiva/métodos , Síndrome de Dificultad Respiratoria/terapia , Insuficiencia Respiratoria/terapia , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Unidades de Cuidados Intensivos , Masculino , Máscaras , Persona de Mediana Edad , Estudios Prospectivos
14.
Crit Care ; 16(3): 225, 2012 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-22715815

RESUMEN

Conventional mechanical ventilators rely on pneumatic pressure and flow sensors and controllers to detect breaths. New modes of mechanical ventilation have been developed to better match the assistance delivered by the ventilator to the patient's needs. Among these modes, neurally adjusted ventilatory assist (NAVA) delivers a pressure that is directly proportional to the integral of the electrical activity of the diaphragm recorded continuously through an esophageal probe. In clinical settings, NAVA has been chiefly compared with pressure-support ventilation, one of the most popular modes used during the weaning phase, which delivers a constant pressure from breath to breath. Comparisons with proportional-assist ventilation, which has numerous similarities, are lacking. Because of the constant level of assistance, pressure-support ventilation reduces the natural variability of the breathing pattern and can be associated with asynchrony and/or overinflation. The ability of NAVA to circumvent these limitations has been addressed in clinical studies and is discussed in this report. Although the underlying concept is fascinating, several important questions regarding the clinical applications of NAVA remain unanswered. Among these questions, determining the optimal NAVA settings according to the patient's ventilatory needs and/or acceptable level of work of breathing is a key issue. In this report, based on an investigator-initiated round table, we review the most recent literature on this topic and discuss the theoretical advantages and disadvantages of NAVA compared with other modes, as well as the risks and limitations of NAVA.


Asunto(s)
Soporte Ventilatorio Interactivo , Cuidados Críticos , Diafragma/fisiología , Humanos , Unidades de Cuidados Intensivos , Soporte Ventilatorio Interactivo/efectos adversos , Soporte Ventilatorio Interactivo/instrumentación , Soporte Ventilatorio Interactivo/métodos , Alveolos Pulmonares/fisiología , Respiración , Respiración Artificial , Sueño/fisiología
15.
Swiss Med Wkly ; 142: w13551, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22481224

RESUMEN

The real utilisation scenario of non-invasive ventilation (NIV) in Swiss ICUs has never been reported. Using a survey methodology, we developed a questionnaire sent to the directors of the 79 adult ICUs to identify the perceived pattern of NIV utilisation. We obtained a response rate of 62%. The overall utilisation rate for NIV was 26% of all mechanical ventilations, but we found significant differences in the utilisation rates among different linguistic areas, ranging from 20% in the German part to 48% in the French part (p <0.01). NIV was mainly indicated for the acute exacerbations of COPD (AeCOPD), acute cardiogenic pulmonary edema (ACPE) and acute respiratory failure (ARF) in selected do-not-intubate patients. In ACPE, CPAP was much less used than bi-level ventilation and was still applied in AeCOPD. The first line interface was a facial mask (81%) and the preferred type of ventilator was an ICU machine with an NIV module (69%). The perceived use of NIV is generally high in Switzerland, but regional variations are remarkable. The indications of NIV use are in accordance with international guidelines. A high percentage of units consider selected do-not-intubate conditions as an important additional indication.


Asunto(s)
Actitud del Personal de Salud , Presión de las Vías Aéreas Positiva Contínua/estadística & datos numéricos , Unidades de Cuidados Intensivos/estadística & datos numéricos , Ventiladores Mecánicos/estadística & datos numéricos , Enfermedad Aguda , Adulto , Directivas Anticipadas , Humanos , Máscaras/estadística & datos numéricos , Pautas de la Práctica en Medicina/estadística & datos numéricos , Enfermedad Pulmonar Obstructiva Crónica/terapia , Edema Pulmonar/terapia , Insuficiencia Respiratoria/terapia , Estadísticas no Paramétricas , Encuestas y Cuestionarios , Suiza
16.
Chest ; 142(2): 367-376, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22406958

RESUMEN

BACKGROUND: Different kinds of ventilators are available to perform noninvasive ventilation (NIV) in ICUs. Which type allows the best patient-ventilator synchrony is unknown. The objective was to compare patient-ventilator synchrony during NIV between ICU, transport­both with and without the NIV algorithm engaged­and dedicated NIV ventilators. METHODS: First, a bench model simulating spontaneous breathing efforts was used to assess the respective impact of inspiratory and expiratory leaks on cycling and triggering functions in 19 ventilators. Second, a clinical study evaluated the incidence of patient-ventilator asynchronies in 15 patients during three randomized, consecutive, 20-min periods of NIV using an ICU ventilator with and without its NIV algorithm engaged and a dedicated NIV ventilator. Patient-ventilator asynchrony was assessed using flow, airway pressure, and respiratory muscles surface electromyogram recordings. RESULTS: On the bench, frequent auto-triggering and delayed cycling occurred in the presence of leaks using ICU and transport ventilators. NIV algorithms unevenly minimized these asynchronies, whereas no asynchrony was observed with the dedicated NIV ventilators in all except one. These results were reproduced during the clinical study: The asynchrony index was significantly lower with a dedicated NIV ventilator than with ICU ventilators without or with their NIV algorithm engaged (0.5% [0.4%-1.2%] vs 3.7% [1.4%-10.3%] and 2.0% [1.5%-6.6%], P < .01), especially because of less auto-triggering. CONCLUSIONS: Dedicated NIV ventilators allow better patient-ventilator synchrony than ICU and transport ventilators, even with their NIV algorithm. However, the NIV algorithm improves, at least slightly and with a wide variation among ventilators, triggering and/or cycling off synchronization.


Asunto(s)
Cuidados Críticos , Respiración con Presión Positiva/instrumentación , Insuficiencia Respiratoria/terapia , Ventiladores Mecánicos , Anciano , Algoritmos , Estudios Cruzados , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Biológicos , Insuficiencia Respiratoria/etiología , Insuficiencia Respiratoria/fisiopatología , Músculos Respiratorios/fisiopatología , Transporte de Pacientes
18.
Chest ; 141(2): 469-476, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21778253

RESUMEN

BACKGROUND: Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. METHODS: Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. RESULTS: For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. CONCLUSIONS: Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.


Asunto(s)
Análisis de Falla de Equipo , Monitoreo Fisiológico/instrumentación , Respiración con Presión Positiva/instrumentación , Programas Informáticos , Diseño de Equipo , Servicios de Atención de Salud a Domicilio , Humanos , Reproducibilidad de los Resultados , Ventiladores Mecánicos
19.
Intensive Care Med ; 37(11): 1787-92, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21976185

RESUMEN

PURPOSE: To evaluate the efficacy of delivering a mixture of helium and oxygen gas (He­O2) in spontaneous ventilation. Three high oxygen flow reservoir masks were tested: the Heliox21, specifically designed for helium; the Hi-Ox80 mask, with an inspiratory and an expiratory valve; and a standard high-concentration face mask. METHODS: This prospective randomized crossover study was performed in six healthy volunteers in a laboratory setting. Volunteers breathed a mixture of 78% He/22% O2 through each of the masks under two different breathing conditions (rest and hyperventilation: minute ventilation of 14.9 ± 6.1 and 26.7 ± 8.7 L min(−1), respectively) and four different He­O2 flow rates (7, 10, 12, and 15 L min(−1)). RESULTS: A nasopharyngeal catheter was used to estimate He pharyngeal concentration (Fp [He]) in the airways in order to determine the percentage of contamination with room air (% air cont) at end-expiration. Under all testing conditions, the Hi-Ox80 mask presented a significantly lower % air cont. During resting breathing pattern, a Fp [He] higher than 50% was achieved in 54% of the tests performed with the Hi-Ox80 mask compared to 29% for the Heliox21 mask and only 17% for the standard mask. At hyperventilation, a Fp [He] higher than 50% was achieved in 17% of the tests performed with the Hi-Ox mask compared to 4% for the other two masks. CONCLUSION: He­O2 administration via the usual high-concentration reservoir masks results in significant dilution by room air. The Hi-Ox80 mask minimized room air contamination and much more frequently achieved a pharyngeal He concentration higher than 50%.


Asunto(s)
Helio/administración & dosificación , Máscaras/normas , Oxígeno/administración & dosificación , Respiración , Adulto , Estudios Cruzados , Femenino , Francia , Humanos , Masculino , Estudios Prospectivos
20.
Intensive Care Med ; 37(2): 263-71, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20871978

RESUMEN

PURPOSE: To determine if, compared with pressure support (PS), neurally adjusted ventilatory assist (NAVA) reduces trigger delay, inspiratory time in excess, and the number of patient-ventilator asynchronies in intubated patients. METHODS: Prospective interventional study in spontaneously breathing patients intubated for acute respiratory failure. Three consecutive periods of ventilation were applied: (1) PS1, (2) NAVA, (3) PS2. Airway pressure, flow, and transesophageal diaphragmatic electromyography were continuously recorded. RESULTS: All results are reported as median (interquartile range, IQR). Twenty-two patients were included, 36.4% (8/22) having obstructive pulmonary disease. NAVA reduced trigger delay (ms): NAVA, 69 (57-85); PS1, 178 (139-245); PS2, 199 (135-256). NAVA improved expiratory synchrony: inspiratory time in excess (ms): NAVA, 126 (111-136); PS1, 204 (117-345); PS2, 220 (127-366). Total asynchrony events were reduced with NAVA (events/min): NAVA, 1.21 (0.54-3.36); PS1, 3.15 (1.18-6.40); PS2, 3.04 (1.22-5.31). The number of patients with asynchrony index (AI) >10% was reduced by 50% with NAVA. In contrast to PS, no ineffective effort or late cycling was observed with NAVA. There was less premature cycling with NAVA (events/min): NAVA, 0.00 (0.00-0.00); PS1, 0.14 (0.00-0.41); PS2, 0.00 (0.00-0.48). More double triggering was seen with NAVA, 0.78 (0.46-2.42); PS1, 0.00 (0.00-0.04); PS2, 0.00 (0.00-0.00). CONCLUSIONS: Compared with standard PS, NAVA can improve patient-ventilator synchrony in intubated spontaneously breathing intensive care patients. Further studies should aim to determine the clinical impact of this improved synchrony.


Asunto(s)
Diafragma/inervación , Diseño de Equipo , Ventilación con Presión Positiva Intermitente/instrumentación , Respiración Artificial/métodos , Insuficiencia Respiratoria/terapia , Procesamiento de Señales Asistido por Computador , Anciano , Diafragma/fisiología , Electromiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Mecánica Respiratoria/fisiología