Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Arrhythm ; 40(4): 879-890, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39139871

RESUMEN

Background: Patients with atrial fibrillation (AF) who are not suitable for long-term anticoagulant therapy undergo percutaneous left atrial appendage closure (LAAC). The safety and feasibility of left atrial catheter ablation (CA) procedures after LAAC remain unclear. This study aimed to clarify the feasibility and safety of CA after LAAC, including in the early phase within 180 days. Methods: Characteristics and clinical outcomes of 46 patients with AF who had undergone both CA and LAAC within 2 years (mean age, 72 years; 29 men) were compared between those who had undergone CA-first (31 patients) and LAAC-first (15 patients). Results: The mean CHA2DS2-VASc and HAS-BLED scores were 4.8 and 3.3 points, respectively. The LAAC-first strategy was often used in patients with prior major bleeding and LAA thrombosis or sludge. In the LAAC-first group, the mean duration between both procedures was 212 days, and all LAAC-first patients, including seven patients in the early phase, could undergo CA without LAAC device-related complications; moreover, no cardiovascular adverse events were reported after both procedures (mean periods: 420 days). After CA post-LAAC, no device-related adverse events (device-related thrombosis, new peri-device leak appearance, peri-device leak increase, or device dislodgement) were observed, whereas, after LAAC post-CA, 3 new peri-device leak appearance events and 1 peri-device leak increase event were observed, especially patients who underwent LAAC in the early phase post-CA. Conclusion: Based on single-center experience, left atrial CA in the presence of an LAAC device implanted including the early phase was safe and feasible.

2.
JACC Asia ; 4(6): 481-482, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39100697
3.
Int J Cardiol Heart Vasc ; 53: 101449, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39022741

RESUMEN

Background: Percutaneous left atrial appendage closure (LAAC) is an effective therapy to prevent thromboembolic events among patients with atrial fibrillation (AF). However, since the left atrial appendage (LAA) contributes to left atrial volume and serves as a buffer for increasing left atrial pressure, this procedure may impair left atrium (LA) compliance, enlarge LA, and deteriorate diastolic function. In this study, we sought to investigate the change in left atrial volume index (LAVI) following LAAC and its effect on prognosis. Methods and Results: We analyzed 225 patients from the OCEAN-LAAC registry, an ongoing, multicenter Japanese study. Comparing LAVI measurements at baseline and 6 months after LAAC, no significant increase was observed (55.0 [44.0, 70.0] ml/m2 vs. 55.0 [42.0, 75.6] ml/m2; P = 0.31). However, some patients underwent LAVI increase. Particularly, a smaller LAVI (odds ratio [OR]: 0.98 [95 % confidence interval (CI): 0.97-0.996]) and elevated tricuspid regurgitation pressure (TRPG) at baseline (OR: 1.04 [95 % CI: 1.00 - 1.08]) were significantly related to the increase in LAVI at 6-month follow-up. In addition, a 5 ml/m2 increase in LAVI was significantly associated with subsequent heart failure hospitalization (HFH) (hazard ratio: 3.37 [95 % CI: 1.18-9.65]). This association, however, was not observed in patients with lower baseline LAVI (≤55 ml/m2) but was only seen in those with a baseline LAVI over 55 ml/m2. Conclusion: Our study demonstrated an increase in LAVI after LAAC was related to smaller LAVI or elevated TRPG at baseline. The LAVI increase was significantly associated with subsequent HFH.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38833119

RESUMEN

The MitraClip G4 device has controlled gripper actuation (CGA) system, which allows the anterior and posterior grippers operate separately in transcatheter edge-to-edge repair (TEER). We investigated the indications and outcomes of the use of CGA system during TEER for significant mitral regurgitation (MR). We reviewed 158 patients undergoing TEER with MitraClip G4 from September 2020 to July 2023. The CGA indications were: (1) for grasping and (2) for leaflet insertion confirmation. Leaflet grasping was completed with CGA in 18 patients (11 and 7 patients for grasping and leaflet insertion confirmation, respectively). Patients with flail leaflets or coaptation gap more frequently required CGA, indicating more complex mitral valve anatomy. The procedural success and adverse event rates (death, leaflet tear and single leaflet device attachment) were not different between the CGA and non-CGA groups. In patients requiring CGA, single leaflet device attachment was observed in 1 patient and leaflet tear in 1 patient during follow-up. In these two cases, CGA was required for grasping, and the clip was moved over a large distance (6.5 and 12.4 mm, respectively). In patients who had undergone CGA for confirmation, no device-related adverse event or MR recurrence was noted. In patients with complex mitral valve anatomy, CGA may be a safe and effective method for confirming leaflet insertion. It should be noted that when using CGA for leaflet grasping, especially when the clip is moved significantly, attention should be paid to leaflet adverse events.

5.
Heart Vessels ; 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38839649

RESUMEN

Currently, no consensus has been established on the most effective antithrombotic therapy to prevent thromboembolic and bleeding events in patients undergoing percutaneous left atrial appendage closure (LAAC) with preprocedural thromboembolic or bleeding events under oral anticoagulation (OAC) therapy. We retrospectively investigated the incidence of device-related thrombosis (DRT), thromboembolic events, and bleeding events in patients who underwent LAAC from September 2019 to October 2022. After categorizing patients into three groups based on preprocedural thromboembolic or bleeding events under OAC therapy, we compared the incidence of DRT and prognosis according to the postprocedural antithrombotic therapy. In patients who received the conventional antithrombotic therapy (OAC with and without single antiplatelet therapy for 45 days after LAAC and dual-antiplatelet therapy from 45 days to 6 months followed by single antiplatelet therapy), preprocedural thromboembolic events despite OAC were independently associated with DRT or postprocedural thromboembolic events at the 3 year follow-up (hazard ratio [HR] 4.55; 95% confidence interval [CI] 1.32-15.6; P = 0.016), whereas preprocedural bleeding events were independently associated with postprocedural bleeding events (HR 8.01, 95% CI 1.45-58.3; P = 0.036). Continuation of OAC for 12 months among patients who developed preprocedural thromboembolic events during OAC significantly decreased the incidence of DRT or postoperative thromboembolic events (P = 0.002) with no increase in the bleeding events (P = 0.522). Preprocedural thromboembolic and bleeding events can predict adverse events after LAAC with the conventional antiplatelet-based antithrombotic therapy. Patients who develop thromboembolic events under continuous OAC may benefit from continuous OAC for 1 year after LAAC.

6.
J Arrhythm ; 40(3): 620-623, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38939787

RESUMEN

We have seen ischemic stroke associated with a high-grade device-related pedunculated thrombosis after left atrial appendage closure (LAAC) after discontinuation of oral anticoagulations (OACs). Continuation of OACs, including half-dose direct oral anticoagulations after LAAC, may be a better option for patients at high risk of thromboembolism to prevent further thromboembolic events.

7.
Catheter Cardiovasc Interv ; 104(2): 318-329, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38895767

RESUMEN

BACKGROUND: Patients with nonvalvular atrial fibrillation (AF) not suitable for long-term anticoagulant therapy undergo percutaneous left atrial appendage closure (LAAC) using the WATCHMAN device. The safety and efficacy of WATCHMAN-FLX (WM-FLX) compared with WATCHMAN-2.5 (WM-2.5), particularly in Asian populations, is unknown. METHODS: We evaluated the background, procedure, and clinical outcomes of 199 patients who underwent LAAC between September 2019 and December 2022 and compared WM-2.5 (72 patients) with WM-FLX (127 patients). RESULTS: The mean age was 76 years, with 128 men, and 100 had nonparoxysmal AF (non-PAF). The mean CHA2DS2-VASc, and HAS-BLED were 5.1, and 3.2 points, respectively. WM-FLX group demonstrated a shorter procedure time than WM-2.5 group (50 vs. 42 min, p = 0.001). The WM-FLX group demonstrated no procedural-related acute cardiac tamponade, which was significantly low (5.6% vs. 0%, p = 0.02), and a significantly higher rate of complete seal at 45-day (63% vs. 80%, p = 0.04). WM-FLX group had a significantly higher cumulative 1-year incidence of device-related thrombosis (DRT) than WM-2.5 group (3.4% vs. 7.0%, Log-rank p = 0.01). Univariate analysis identified two DRT risk factors in the WM-FLX group: non-PAF (odds ratio [OR] 7.72; 95% confidence interval [CI] 1.20-48.7; p = 0.04), and 35-mm device (OR 5.13; 95% CI 1.31-19.8; p = 0.02). CONCLUSIONS: WM-FLX significantly improved the procedural quality and safety of LAAC. However, DRT remains an important issue even in the novel LAAC device, being a hazard for patients with high DRT risk, such as having non-PAF and using 35-mm devices.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Cateterismo Cardíaco , Trombosis , Humanos , Masculino , Femenino , Apéndice Atrial/fisiopatología , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Anciano , Factores de Riesgo , Incidencia , Factores de Tiempo , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Anciano de 80 o más Años , Estudios Retrospectivos , Trombosis/etiología , Trombosis/prevención & control , Medición de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Diseño de Prótesis , Cierre del Apéndice Auricular Izquierdo
10.
Clin Case Rep ; 12(5): e8906, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38751959

RESUMEN

Key Clinical Message: Atrial fibrillation ablation, including pulmonary vein isolation immediately after left atrial appendage closure (LAAC), is a rare and challenging issue. Intracardiac echocardiography guidance can help identify the LAAC device position for safe atrial fibrillation ablation without LAAC device-related adverse events even immediately after LAAC device implantation. Abstract: Early phase atrial fibrillation (AF) ablation after left atrial appendage closure (LAAC) is a rare and challenging issue. Here, we present a case illustrating the feasibility of AF ablation under intracardiac echocardiography guidance immediately after LAAC device implantation without LAAC device-related adverse events.

11.
Circ J ; 88(7): 1187-1197, 2024 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-38763735

RESUMEN

BACKGROUND: Limited data are available regarding clinical outcomes after percutaneous left atrial appendage closure using WATCHMAN FLX (WM-FLX) and WATCHMAN-2.5 (WM2.5) devices in Asian patients. METHODS AND RESULTS: Data of 1,464 consecutive patients (WM-FLX, n=909; WM2.5, n=555) were extracted from a Japanese multicenter registry, and clinical data were compared between the 2 groups. No in-hospital deaths, periprocedural stroke, or device embolization occurred. Procedural success was significantly higher in the WM-FLX than WM2.5 group (95.8% vs. 91.9%; P=0.002) owing to the lower incidence of periprocedural pericardial effusion (0.55% vs. 1.8%; P=0.021). No significant differences in all-cause death, postprocedural stroke, and device-related thrombus were observed between the 2 groups. However, the cumulative bleeding rate at 1 year was substantially lower in the WM-FLX group (7.8% vs. 16.4%; P<0.001). Landmark analysis of bleeding events highlighted lower bleeding rates in the WM-FLX than WM2.5 group within the first 6 months (6.4% vs. 14.8%; P<0.001), with comparable bleeding rates over the 6- to 12-month period (1.5% vs. 3.2%, respectively; P=0.065). CONCLUSIONS: This study demonstrated higher early safety and lower 1-year bleeding rates in the WM-FLX than WM2.5 group. The lower bleeding events with WM-FLX are likely due to multiple factors other than purely difference in devices, such as postprocedural drug regimen.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Sistema de Registros , Humanos , Anciano , Apéndice Atrial/cirugía , Masculino , Femenino , Anciano de 80 o más Años , Fibrilación Atrial/cirugía , Japón , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento , Persona de Mediana Edad , Cierre del Apéndice Auricular Izquierdo
12.
Circ Cardiovasc Interv ; 17(6): e013794, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38629311

RESUMEN

BACKGROUND: The extent of cardiac damage and its association with clinical outcomes in patients undergoing transcatheter edge-to-edge repair (TEER) for degenerative mitral regurgitation remains unclear. This study was aimed to investigate cardiac damage in patients with degenerative mitral regurgitation treated with TEER and its association with outcomes. METHODS: We analyzed patients with degenerative mitral regurgitation treated with TEER in the Optimized Catheter Valvular Intervention-Mitral registry, which is a prospective, multicenter observational data collection in Japan. The study subjects were classified according to the extent of cardiac damage at baseline: no extravalvular cardiac damage (stage 0), mild left ventricular or left atrial damage (stage 1), moderate left ventricular or left atrial damage (stage 2), or right heart damage (stage 3). Two-year mortality after TEER was compared using Kaplan-Meier analysis. RESULTS: Out of 579 study participants, 8 (1.4%) were classified as stage 0, 76 (13.1%) as stage 1, 319 (55.1%) as stage 2, and 176 (30.4%) as stage 3. Two-year survival was 100% in stage 0, 89.5% in stage 1, 78.9% in stage 2, and 75.3% in stage 3 (P=0.013). Compared with stage 0 to 1, stage 2 (hazard ratio, 3.34 [95% CI, 1.03-10.81]; P=0.044) and stage 3 (hazard ratio, 4.51 [95% CI, 1.37-14.85]; P=0.013) were associated with increased risk of 2-year mortality after TEER. Significant reductions in heart failure rehospitalization rate and New York Heart Association functional scale were observed following TEER (both, P<0.001), irrespective of the stage of cardiac damage. CONCLUSIONS: Advanced cardiac damage is associated with an increased risk of mortality in patients undergoing TEER for degenerative mitral regurgitation. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: UMIN000023653.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Sistema de Registros , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Masculino , Femenino , Anciano , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Japón , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Resultado del Tratamiento , Factores de Tiempo , Estudios Prospectivos , Factores de Riesgo , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Medición de Riesgo , Recuperación de la Función , Lesiones Cardíacas/mortalidad , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia , Lesiones Cardíacas/diagnóstico por imagen
14.
Heart Vessels ; 39(6): 539-548, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38329512

RESUMEN

For pre-procedural planning of left atrial appendage (LAA) closure, sizing is crucial. Although transesophageal echocardiography (TEE) is a standard modality, cardiac computed tomography (CT) is also widely used. The virtual TEE (V-TEE) that our group developed enables us to reconstruct images similar to TEE images from CT images. The software should be helpful to understand and plan the procedure strategy. Accordingly, we investigated the utility of V-TEE. Sixty-six patients at 4 participating sites who completed both CT and TEE prior to LAA closure were included. The LAA diameter at the landing zone (LZ) for WATCHMAN™ device implantation was statistically compared at 0°, 45°, 90°, and 135° between V-TEE and TEE. Among 66 cases, only 3 cases were excluded due to poor imaging quality, and 63 cases were analyzed. The device LZ diameters based on V-TEE were strongly correlated with those based on TEE, despite the significantly greater diameter based on V-TEE with mean differences of 2.4 to 3.0 mm (all of them: P < 0.001). The discordances (V-TEE/TEE ratio) at most angles were significantly larger in the elliptical LAAs. V-TEE provides a valuable method for the evaluation of the LAA diameters. V-TEE-based measurements were larger than conventional TEE-based measurements, especially in cases of elliptical LAAs. The assessment by V-TEE has the potential benefit of ensuring proper device sizing regardless of the LAA morphology.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ecocardiografía Transesofágica , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Ecocardiografía Transesofágica/métodos , Femenino , Masculino , Anciano , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Tomografía Computarizada por Rayos X/métodos , Anciano de 80 o más Años , Estudios Retrospectivos , Cateterismo Cardíaco/métodos , Dispositivo Oclusor Septal , Persona de Mediana Edad , Tomografía Computarizada Multidetector/métodos , Reproducibilidad de los Resultados
15.
J Clin Med ; 13(3)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38337545

RESUMEN

Background: Transcatheter edge-to-edge mitral valve repair (TEER) has emerged as a viable approach to addressing substantial secondary mitral regurgitation. In the contemporary landscape where ultimate heart failure-specific therapies, such as cardiac replacement modalities, are available, prognosticating a high-risk cohort susceptible to early cardiac mortality post-TEER is pivotal for formulating an effective therapeutic regimen. Methods: Our study encompassed individuals with secondary mitral regurgitation and chronic heart failure enlisted in the multi-center (Optimized CathEter vAlvular iNtervention (OCEAN)-Mitral registry. We conducted an assessment of baseline variables associated with cardiac death within one year following TEER. Results: Amongst the 1517 patients (median age: 78 years, 899 males), 101 experienced cardiac mortality during the 1-year observation period after undergoing TEER. Notably, a history of heart failure-related admissions within the preceding year, utilization of intravenous inotropes, and elevated plasma B-type natriuretic peptide levels emerged as independent prognosticators for the primary outcome (p < 0.05 for all). Subsequently, we devised a novel risk-scoring system encompassing these variables, which significantly stratified the cumulative incidence of the 1-year primary outcome (16%, 8%, and 4%, p < 0.001). Conclusions: Our study culminated in the development of a new risk-scoring system aimed at predicting 1-year cardiac mortality post-TEER.

16.
Circ J ; 88(6): 938-943, 2024 05 24.
Artículo en Inglés | MEDLINE | ID: mdl-38267035

RESUMEN

BACKGROUND: Clinical outcomes after percutaneous coronary intervention have improved with the use of drug-eluting stents, but data beyond 10 years are limited. The purpose of this study was to evaluate the clinical outcomes of patients undergoing sirolimus-eluting stent implantation with follow-up beyond 10 years and to determine the impact of clinical and angiographic characteristics on long-term prognosis. METHODS AND RESULTS: The clinical outcomes of 885 patients who had undergone sirolimus-eluting stent implantation at a single institution were retrospectively reviewed. Primary endpoints included in the analysis were clinically driven target lesion revascularization (cTLR) and target lesion revascularization (TLR). Univariate and multivariate nominal logistic regression was used for data analysis. The incidence rates of cTLR and TLR beyond 10 years after sirolimus-eluting stent implantation were 16.4% and 36.8%, respectively, with cTLR tending to decrease beyond 10 years. Acute coronary syndrome was a predominant trigger for cTLR. Age, statin use, and stent restenosis emerged as predictors of cTLR within 10 years, but no significant predictors other than age were identified beyond 10 years. CONCLUSIONS: Events continue to occur beyond 10 years after sirolimus-eluting stent implantation, with a trend toward an increase in acute coronary syndromes. It is important to be vigilant about the occurrence of acute coronary syndromes during long-term follow-up.


Asunto(s)
Stents Liberadores de Fármacos , Sirolimus , Humanos , Sirolimus/administración & dosificación , Stents Liberadores de Fármacos/efectos adversos , Anciano , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Estudios de Seguimiento , Intervención Coronaria Percutánea/efectos adversos , Síndrome Coronario Agudo/terapia , Resultado del Tratamiento , Factores de Tiempo , Reestenosis Coronaria/etiología , Reestenosis Coronaria/epidemiología , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA