Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 94(12)2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38109470

RESUMEN

We present a fluorescence-detection system for laser-cooled 9Be+ ions based on silicon photomultipliers (SiPMs) operated at 4 K and integrated into our cryogenic 1.9 T multi-Penning-trap system. Our approach enables fluorescence detection in a hermetically sealed cryogenic Penning-trap chamber with limited optical access, where state-of-the-art detection using a telescope and photomultipliers at room temperature would be extremely difficult. We characterize the properties of the SiPM in a cryocooler at 4 K, where we measure a dark count rate below 1 s-1 and a detection efficiency of 2.5(3)%. We further discuss the design of our cryogenic fluorescence-detection trap and analyze the performance of our detection system by fluorescence spectroscopy of 9Be+ ion clouds during several runs of our sympathetic laser-cooling experiment.

2.
Rev Sci Instrum ; 94(11)2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37972020

RESUMEN

Currently, the world's only source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of fundamental interactions and their symmetries. However, magnetic field fluctuations from the facility operation limit the precision of upcoming measurements. To overcome this limitation, we have designed the transportable antiproton trap system BASE-STEP to relocate antiprotons to laboratories with a calm magnetic environment. We anticipate that the transportable antiproton trap will facilitate enhanced tests of charge, parity, and time-reversal invariance with antiprotons and provide new experimental possibilities of using transported antiprotons and other accelerator-produced exotic ions. We present here the technical design of the transportable trap system. This includes the transportable superconducting magnet, the cryogenic inlay consisting of the trap stack and detection systems, and the differential pumping section to suppress the residual gas flow into the cryogenic trap chamber.

3.
Rev Sci Instrum ; 94(10)2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37874231

RESUMEN

We present the design and characterization of a cryogenic window based on an ultra-thin aluminized biaxially oriented polyethylene terephthalate foil at T < 10 K, which can withstand a pressure difference larger than 1 bar at a leak rate <1×10-9 mbar l/s. Its thickness of ∼1.7 µm makes it transparent to various types of particles over a broad energy range. To optimize the transfer of 100 keV antiprotons through the window, we tested the degrading properties of different aluminum coated polymer foils of thicknesses between 900 and 2160 nm, concluding that 1760 nm foil decelerates antiprotons to an average energy of 5 keV. We have also explicitly studied the permeation as a function of coating thickness and temperature and have performed extensive thermal and mechanical endurance and stress tests. Our final design integrated into the experiment has an effective open surface consisting of seven holes with a diameter of 1 mm and will transmit up to 2.5% of the injected 100 keV antiproton beam delivered by the Antiproton Decelerator and Extra Low ENergy Antiproton ring facility of CERN.

4.
Artículo en Inglés | MEDLINE | ID: mdl-37288385

RESUMEN

Abstract: The BASE collaboration at the antiproton decelerator/ELENA facility of CERN compares the fundamental properties of protons and antiprotons with ultra-high precision. Using advanced Penning trap systems, we have measured the proton and antiproton magnetic moments with fractional uncertainties of 300 parts in a trillion (p.p.t.) and 1.5 parts in a billion (p.p.b.), respectively. The combined measurements improve the resolution of the previous best test in that sector by more than a factor of 3000. Very recently, we have compared the antiproton/proton charge-to-mass ratios with a fractional precision of 16 p.p.t., which improved the previous best measurement by a factor of 4.3. These results allowed us also to perform a differential matter/antimatter clock comparison test to limits better than 3%. Our measurements enable us to set limits on 22 coefficients of CPT- and Lorentz-violating standard model extensions (SME) and to search for potentially asymmetric interactions between antimatter and dark matter. In this article, we review some of the recent achievements and outline recent progress towards a planned improved measurement of the antiproton magnetic moment with an at least tenfold improved fractional accuracy.

5.
Rev Sci Instrum ; 93(9): 093303, 2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36182508

RESUMEN

We describe a newly developed polytetrafluoroethylene/copper capacitor driven by a cryogenic piezoelectric slip-stick stage and demonstrate with the chosen layout cryogenic capacitance tuning of ≈60 pF at ≈10 pF background capacitance. Connected to a highly sensitive superconducting toroidal LC circuit, we demonstrate tuning of the resonant frequency between 345 and 685 kHz, at quality factors Q > 100 000. Connected to a cryogenic ultra low noise amplifier, a frequency tuning range between 520 and 710 kHz is reached, while quality factors Q > 86 000 are achieved. This new device can be used as a versatile image current detector in high-precision Penning-trap experiments or as an LC-circuit-based haloscope detector to search for the conversion of axion-like dark matter to radio-frequency photons. This new development increases the sensitive detection bandwidth of our axion haloscope by a factor of ≈1000.

6.
Nature ; 601(7891): 53-57, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34987217

RESUMEN

The standard model of particle physics is both incredibly successful and glaringly incomplete. Among the questions left open is the striking imbalance of matter and antimatter in the observable universe1, which inspires experiments to compare the fundamental properties of matter/antimatter conjugates with high precision2-5. Our experiments deal with direct investigations of the fundamental properties of protons and antiprotons, performing spectroscopy in advanced cryogenic Penning trap systems6. For instance, we previously compared the proton/antiproton magnetic moments with 1.5 parts per billion fractional precision7,8, which improved upon previous best measurements9 by a factor of greater than 3,000. Here we report on a new comparison of the proton/antiproton charge-to-mass ratios with a fractional uncertainty of 16 parts per trillion. Our result is based on the combination of four independent long-term studies, recorded in a total time span of 1.5 years. We use different measurement methods and experimental set-ups incorporating different systematic effects. The final result, [Formula: see text], is consistent with the fundamental charge-parity-time reversal invariance, and improves the precision of our previous best measurement6 by a factor of 4.3. The measurement tests the standard model at an energy scale of 1.96 × 10-27 gigaelectronvolts (confidence level 0.68), and improves ten coefficients of the standard model extension10. Our cyclotron clock study also constrains hypothetical interactions mediating violations of the clock weak equivalence principle (WEPcc) for antimatter to less than 1.8 × 10-7, and enables the first differential test of the WEPcc using antiprotons11. From this interpretation we constrain the differential WEPcc-violating coefficient to less than 0.030.

7.
Nature ; 596(7873): 514-518, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34433946

RESUMEN

Efficient cooling of trapped charged particles is essential to many fundamental physics experiments1,2, to high-precision metrology3,4 and to quantum technology5,6. Until now, sympathetic cooling has required close-range Coulomb interactions7,8, but there has been a sustained desire to bring laser-cooling techniques to particles in macroscopically separated traps5,9,10, extending quantum control techniques to previously inaccessible particles such as highly charged ions, molecular ions and antimatter. Here we demonstrate sympathetic cooling of a single proton using laser-cooled Be+ ions in spatially separated Penning traps. The traps are connected by a superconducting LC circuit that enables energy exchange over a distance of 9 cm. We also demonstrate the cooling of a resonant mode of a macroscopic LC circuit with laser-cooled ions and sympathetic cooling of an individually trapped proton, reaching temperatures far below the environmental temperature. Notably, as this technique uses only image-current interactions, it can be easily applied to an experiment with antiprotons1, facilitating improved precision in matter-antimatter comparisons11 and dark matter searches12,13.

8.
Przegl Lek ; 58(4): 344-7, 2001.
Artículo en Polaco | MEDLINE | ID: mdl-11450365

RESUMEN

The main subject of the study was a toxicological investigation of biological specimens coming from two cases of intoxication with mixture of drugs. Two young people decided to commit suicide by the use of mixture of drugs mainly analgesic in approximately equal doses. For one person the dose of drugs administered turned out to be fatal while second person survived with the symptoms of acute intoxication. The analysis carried out with the use of liquid chromatographic method with mass detection (HPLC/MS) confirmed the presence of mixture of drugs in blood of living person and in postmortem specimens of the victim in significant concentrations. The toxicological findings have delivered information for discussion in medico-legal and ethical aspects.


Asunto(s)
Drogas Ilícitas/sangre , Drogas Ilícitas/envenenamiento , Intento de Suicidio , Adulto , Atenolol/sangre , Atenolol/envenenamiento , Cromatografía Líquida de Alta Presión , Diclofenaco/sangre , Diclofenaco/envenenamiento , Estazolam/sangre , Estazolam/envenenamiento , Resultado Fatal , Femenino , Humanos , Ibuprofeno/sangre , Ibuprofeno/envenenamiento , Cetoprofeno/sangre , Cetoprofeno/envenenamiento , Masculino , Metronidazol/sangre , Metronidazol/envenenamiento , Naproxeno/sangre , Naproxeno/envenenamiento , Polonia , Intento de Suicidio/legislación & jurisprudencia , Teofilina/sangre , Teofilina/envenenamiento , Tolperisona/sangre , Tolperisona/envenenamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...