Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Nano Lett ; 23(7): 2816-2821, 2023 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-37011402

RESUMEN

Silicon carbide nanowires (SiC NWs) exhibit promising features to allow solution-processable electronics to be deployed in harsh environments. By utilizing a nanoscale form of SiC, we were able to disperse the material into liquid solvents, while maintaining the resilience of bulk SiC. This letter reports the fabrication of SiC NW Schottky diodes. Each diode consisted of just one nanowire with an approximate diameter of 160 nm. In addition to analyzing the diode performance, the effects of elevated temperatures and proton irradiation on the current-voltage characteristics of SiC NW Schottky diodes were also examined. The device could maintain similar values for ideality factor, barrier height, and effective Richardson constant upon proton irradiation with a fluence of 1016 ion/cm2 at 873 K. As a result, these metrics have clearly demonstrated the high-temperature tolerance and irradiation resistance of SiC NWs, ultimately indicating that they may provide utility in allowing solution-processable electronics in harsh environments.

2.
ACS Appl Mater Interfaces ; 15(4): 6005-6012, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36599089

RESUMEN

Stretchable electronic devices that maintain electrical function when subjected to stress or strain are useful for enabling new applications for electronics, such as wearable devices, human-machine interfaces, and components for soft robotics. Powering and communicating with these devices is a challenge. NFC (near-field communication) coils solve this challenge but only work efficiently when they are in close proximity to the device. Alternatively, electrical signals and power can arrive via physical connections between the stretchable device and an external source, such as a battery. The ability to create a robust physical and electrical connection between mechanically disparate components may enable new types of hybrid devices in which at least a portion is stretchable or deformable, such as hinges. This paper presents a simple method to make mechanical and electrical connections between elastomeric conductors and flexible (or rigid) conductors. The adhesion at the interface between these disparate materials arises from surface chemistry that forms strong covalent bonds. The utilization of liquid metals as the conductor provides stretchable interconnects between stretchable and non-stretchable electrical traces. The liquid metal can be printed or injected into vias to create interconnects. We characterized the mechanical and electrical properties of these hybrid devices to demonstrate the concept and identify geometric design criteria to maximize mechanical strength. The work here provides a simple and general strategy for creating mechanical and electrical connections that may find use in a variety of stretchable and soft electronic devices.

3.
Materials (Basel) ; 15(22)2022 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-36431357

RESUMEN

The present study involves detecting and determining CIP by a new electrochemical sensor based on graphene (Gr) in the presence of sodium dodecyl sulfate (SDS) employing voltammetric techniques. Surface morphology studies of the sensing material were analyzed using a scanning electron microscope (SEM) and atomic force microscope (AFM). In the electroanalysis of CIP at the developed electrode, an enhanced anodic peak response was recorded, suggesting the electro-oxidation of CIP at the electrode surface. Furthermore, we evaluated the impact of the electrolytic solution, scan rate, accumulation time, and concentration variation on the electrochemical behavior of CIP. The possible electrode mechanism was proposed based on the acquired experimental information. A concentration variation study was performed using differential pulse voltammetry (DPV) in the lower concentration range, and the fabricated electrode achieved a detection limit of 2.9 × 10-8 M. The proposed sensor detected CIP in pharmaceutical and biological samples. The findings displayed good recovery, with 93.8% for tablet analysis and 93.3% to 98.7% for urine analysis. The stability of a developed electrode was tested by inter- and intraday analysis.

4.
Bioengineering (Basel) ; 9(10)2022 Oct 02.
Artículo en Inglés | MEDLINE | ID: mdl-36290489

RESUMEN

In this research, detection of trimethoprim (TMP) was carried out using a nanostructured zinc oxide nanoparticle-modified carbon paste electrode (ZnO/CPE) with an anionic surfactant and sodium dodecyl sulphate (SDS) with the help of voltametric techniques. The electrochemical nature of TMP was studied in 0.2 M pH 3.0 phosphate-buffer solution (PBS). The developed electrode displayed the highest peak current compared to nascent CPE. Effects of variation in different parameters, such as pH, immersion time, scan rate, and concentration, were investigated. The electrode process of TMP was irreversible and diffusion controlled with two electrons transferred. The effective concentration range (8.0 × 10-7 M-1.0 × 10-5 M) of TMP was obtained by varying the concentration with a lower limit of detection obtained to be 2.58 × 10-8 M. In addition, this approach was effectively employed in the detection of TMP in pharmaceutical dosages and samples of urine with the excellent recovery data, suggesting the potency of the developed electrode in clinical and pharmaceutical sample analysis.

5.
ACS Appl Bio Mater ; 2022 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-36040854

RESUMEN

Carbon nanofibers (CNFs) display colossal potential in different fields like energy, catalysis, biomedicine, sensing, and environmental science. CNFs have revealed extensive uses in various sensing platforms due to their distinctive structure, properties, function, and accessible surface functionalization capabilities. This review presents insight into various fabrication methods for CNFs like electrospinning, chemical vapor deposition, and template methods with merits and demerits of each technique. Also, we give a brief overview of CNF functionalization. Their unique physical and chemical properties make them promising candidates for the sensor applications. This review offers detailed discussion of sensing applications (strain sensor, biosensor, small molecule detection, food preservative detection, toxicity biomarker detection, and gas sensor). Various sensing applications of CNF like human motion monitoring and energy storage and conversion are discussed in brief. The challenges and obstacles associated with CNFs for futuristic applications are discussed. This review will be helpful for readers to understand the different fabrication methods and explore various applications of the versatile CNFs.

6.
Materials (Basel) ; 15(14)2022 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-35888502

RESUMEN

A mixed oxide system consisting of Nb2O5 and Ta2O5, was subjected to annealing in air/hydrogen up to 950 °C for 1-4 h to study its sintering behavior. The thermogravimetric-differential scanning calorimetry (TGA-DSC) thermograms indicated the formation of multiple endothermic peaks at temperatures higher than 925 °C. Subsequently, a 30% Ta2O5 and 70% Nb2O5 (mol%) pellet resulted in good sintering behavior at both 900 and 950 °C. The scanning electron microscope (SEM) images corroborated these observations with necking and particle coarsening. The sintered pellets contained a 20.4 and 20.8% mixed oxide (Nb4Ta2O15) phase, along with Ta2O5 and Nb2O5, at both 900 and 950 °C, indicating the possibility of the formation of a solid solution phase. In situ high-temperature X-ray diffraction (XRD) scans also confirmed the formation of the ternary oxide phase at 6 and 19.8% at 890 and 950 °C, respectively. The Hume-Rothery rules could explain the good sintering behavior of the Ta2O5 and Nb2O5 mixed oxides. An oxide composition of 30% Ta2O5 and 70% Nb2O5 (mol%) and a sintering temperature of 950 °C appeared adequate for fabricating well-sintered oxide precursors for subsequent electrochemical polarization studies in fused salts.

7.
Biosensors (Basel) ; 12(8)2022 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-35892449

RESUMEN

Pramipexole (PMXL) belongs to the benzothiazole class of aromatic compounds and is used in treating Parkinson's disease; however, overdosage leads to some abnormal effects that could trigger severe side effects. Therefore, it demands a sensitive analytical tool for trace level detection. In this work, we successfully developed an electrochemical sensor for the trace level detection of PMXL, using the voltammetric method. For the analysis, graphitic carbon nitride (gCN) was opted and synthesized by using a high-temperature thermal condensation method. The synthesized nanoparticles were employed for surface characterization, using transmission electron microscopy (TEM), X-ray diffraction (XRD), and atomic force microscopy (AFM) techniques. The electrochemical characterization of the material was evaluated by using the electrochemical impedance spectroscopy (EIS) technique to evaluate the solution-electrode interface property. The cyclic voltammetry (CV) behavior of PMXL displayed an anodic peak in the forward scan, indicating that PMXL underwent electrooxidation, and an enhanced detection peak with lower detection potential was achieved for gCN-modified carbon paste electrode (gCN·CPE). The influence of different parameters on the electrochemical behavior was analyzed, revealing the diffusion governing the electrode process with an equal number of hydronium ions and electron involvement. For the fabricated gCN·CPE, good linearity range was noticed from 0.05 to 500 µM, and a lower detection limit (LD) of 0.012 µM was achieved for the selected concentration range (0.5 to 30 µM). Selectivity of the electrode in PMXL detection was investigated by conducting an interference study, while the tablet sample analysis demonstrates the sensitive and real-time application of the electrode. The good recovery values for the analysis illustrate the efficiency of the electrode for PMXL analysis.


Asunto(s)
Técnicas Electroquímicas , Grafito , Carbono/química , Técnicas Electroquímicas/métodos , Electrodos , Grafito/química , Límite de Detección , Compuestos de Nitrógeno , Pramipexol
8.
Micromachines (Basel) ; 13(8)2022 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-35893164

RESUMEN

The electrochemical analysis of theophylline (THP) was investigated by fabricating a carbon paste electrode (CPE) modified with graphene oxide (GO) along with copper oxide (CuO) nanoparticles (CuO-GO/CPE). The impact of electro-kinetic parameters such as the heterogeneous rate constant, the scan rate, the accumulation time, the pH, the transfer coefficient, and the number of electrons and protons transferred into the electro-oxidation mechanism of THP has been studied utilizing electrochemical methods such as cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The differential pulse voltammetry technique was employed to investigate THP in pharmaceutical and biological samples, confirming the limit of detection (LOD) and quantification (LOQ) of the THP. X-ray diffraction (XRD) and scanning electron microscopy (SEM) analysis were performed to characterize the CuO nanoparticles. The CuO-GO/CPE was more sensitive in THP detection because its electrocatalytic characteristics displayed an enhanced peak current in the 0.2 M supporting electrolyte of pH 6.0, proving the excellent sensing functioning of the modified electrode.

9.
Micromachines (Basel) ; 13(5)2022 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-35630147

RESUMEN

Significant growth has been observed in the research domain of dye-sensitized solar cells (DSSCs) due to the simplicity in its manufacturing, low cost, and high-energy conversion efficiency. The electrolytes in DSSCs play an important role in determining the photovoltaic performance of the DSSCs, e.g., volatile liquid electrolytes suffer from poor thermal stability. Although low volatility liquid electrolytes and solid polymer electrolytes circumvent the stability issues, gel polymer electrolytes with high ionic conductivity and enduring stability are stimulating substitutes for liquid electrolytes in DSSC. In this review paper, the advantages of gel polymer electrolytes (GPEs) are discussed along with other types of electrolytes, e.g., solid polymer electrolytes and p-type semiconductor-based electrolytes. The benefits of incorporating ionic liquids into GPEs are highlighted in conjunction with the factors that affect the ionic conductivity of GPEs. The strategies on the improvement of the properties of DSSCs based on GPE are also presented.

10.
Micromachines (Basel) ; 13(2)2022 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-35208458

RESUMEN

Fabrication of porous materials from the standard sacrificial template method allows metal oxide nanostructures to be produced and have several applications in energy, filtration and constructing sensing devices. However, the low surface area of these nanostructures is a significant drawback for most applications. Here, we report the synthesis of ZnO/carbon composite monoliths in which carbon is used as a sacrificial template to produce zinc oxide (ZnO) porous nanostructures with a high specific surface area. The synthesized porous oxides of ZnO with a specific surface area of 78 m2/g are at least one order of magnitude higher than that of the ZnO nanotubes reported in the literature. The crucial point to achieving this remarkable result was the usage of a novel ZnO/carbon template where the carbon template was removed by simple heating in the air. As a high surface area porous nanostructured ZnO, these synthesized materials can be useful in various applications including catalysis, photocatalysis, separation, sensing, solar energy harvest and Zn-ion battery and as supercapacitors for energy storage.

11.
J Environ Manage ; 302(Pt A): 113963, 2022 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-34700079

RESUMEN

The production of hydrogen, its separation, and storage for use as a primary source of energy is an important component of the green energy economy of the world. Hydrogen is a potential non-carbon-based energy source, which is gradually replacing the dependency on fossil fuels. It is anticipated that as the alternative fuel since hydrogen can be produced from green and clean sources. The evolution of hydrogen from renewable and non-renewable sources by various technologies has now gained tremendous research and industrial interest. The most appropriate methods for hydrogen generation involve the direct conversion of solar energy, exploitation of solar and wind energy for the electrolysis of water, besides conversion of fuel and biomass. To produce cleaner hydrogen and its separation from the chemical impurities is crucial and several methods including photobiological, photoelectrochemical, electrochemical, photocatalytic, thermochemical, thermolysis, and steam gasification have been used. The diverse types of membranes along with the pressure gas swing adsorption technique is another technique used to separate hydrogen, but the storage of hydrogen in an inexpensive, safe, compact, and environmentally friendly manner is one of the major concerns contributing to the country's economy. Apart from the countless advantages, storage and handling of hydrogen is a serious concern. Owing to its high inflammability, enough safety measures should be adopted during its production and storage as a fuel. It is necessary to provide information regarding the production technologies, storage, and separation methods of hydrogen and the present review addresses these issues.


Asunto(s)
Hidrógeno , Energía Solar , Biomasa , Fuentes Generadoras de Energía , Vapor
12.
Crit Rev Biotechnol ; 42(8): 1180-1212, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34823433

RESUMEN

Neurodegenerative disorders (NDs) are highly prevalent among the aging population. It affects primarily the central nervous system (CNS) but the effects are also observed in the peripheral nervous system. Neural degeneration is a progressive loss of structure and function of neurons, which may ultimately involve cell death. Such patients suffer from debilitating memory loss and altered motor coordination which bring up non-affordable and unavoidable socio-economic burdens. Due to the unavailability of specific therapeutics and diagnostics, the necessity to control or manage NDs raised the demand to investigate and develop efficient alternative approaches. Keeping trends and advancements in view, this report describes both state-of-the-art and challenges in nano-biotechnology-based approaches to manage NDs, toward personalized healthcare management. Sincere efforts are being made to customize nano-theragnostics to control: therapeutic cargo packaging, delivery to the brain, nanomedicine of higher efficacy, deep brain stimulation, implanted stimulation, and managing brain cell functioning. These advancements are useful to design future therapy based on the severity of the patient's neurodegenerative disease. However, we observe a lack of knowledge shared among scientists of a variety of expertise to explore this multi-disciplinary research field for NDs management. Consequently, this review will provide a guideline platform that will be useful in developing novel smart nano-therapies by considering the aspects and advantages of nano-biotechnology to manage NDs in a personalized manner. Nano-biotechnology-based approaches have been proposed as effective and affordable alternatives at the clinical level due to recent advancements in nanotechnology-assisted theragnostics, targeted delivery, higher efficacy, and minimal side effects.


Asunto(s)
Nanopartículas , Enfermedades Neurodegenerativas , Anciano , Humanos , Sistemas de Liberación de Medicamentos , Nanomedicina , Nanopartículas/química , Nanotecnología , Enfermedades Neurodegenerativas/tratamiento farmacológico , Enfermedades Neurodegenerativas/metabolismo
13.
Materials (Basel) ; 14(21)2021 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-34771968

RESUMEN

Over the last few decades, advanced manufacturing and additive printing technologies have made incredible inroads into the fields of engineering, transportation, and healthcare. Among additive manufacturing technologies, 3D printing is gradually emerging as a powerful technique owing to a combination of attractive features, such as fast prototyping, fabrication of complex designs/structures, minimization of waste generation, and easy mass customization. Of late, 4D printing has also been initiated, which is the sophisticated version of the 3D printing. It has an extra advantageous feature: retaining shape memory and being able to provide instructions to the printed parts on how to move or adapt under some environmental conditions, such as, water, wind, light, temperature, or other environmental stimuli. This advanced printing utilizes the response of smart manufactured materials, which offer the capability of changing shapes postproduction over application of any forms of energy. The potential application of 4D printing in the biomedical field is huge. Here, the technology could be applied to tissue engineering, medicine, and configuration of smart biomedical devices. Various characteristics of next generation additive printings, namely 3D and 4D printings, and their use in enhancing the manufacturing domain, their development, and some of the applications have been discussed. Special materials with piezoelectric properties and shape-changing characteristics have also been discussed in comparison with conventional material options for additive printing.

14.
Biomed Microdevices ; 24(1): 2, 2021 11 18.
Artículo en Inglés | MEDLINE | ID: mdl-34792679

RESUMEN

Over the last few years, the microfluidics phenomenon coupled with the Internet of Things (IoT) using innovative nano-functional materials has been recognized as a sustainable and economical tool for point-of-care testing (POCT) of various pathogens influencing human health. The sensors based on these phenomena aim to be designed for cost-effectiveness, make it handy, environment-friendly, and get an accurate, easy, and rapid response. Considering the burgeoning importance of analytical devices in the healthcare domain, this review paper is based on the gist of sensing aspects of the microfabricated paper-based analytical devices (µPADs). The article discusses the various used design methodologies and fabrication approaches and elucidates the recently reported surface modification strategies, detection mechanisms viz., colorimetric, electrochemical, fluorescence, electrochemiluminescence, etc. In a nutshell, this article summarizes the state-of-the-art research work carried out over the nano functionalized paper-based analytical devices and associated challenges/solutions in the point of care testing domain.


Asunto(s)
Internet de las Cosas , Sistemas de Atención de Punto , Humanos , Dispositivos Laboratorio en un Chip , Microfluídica , Papel , Pruebas en el Punto de Atención
15.
J Orthop Case Rep ; 11(12): 92-95, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35415149

RESUMEN

Introduction: A giant cell tumor is a locally aggressive non-cancerous tumor. It usually develops near a joint at the end of the bone. Most occur in the long bones of the legs and arms. Presently, we are considering a case of Ggiant cell tumor over lateral malleolar region with the line of management. Case Report: A 21-year-old male patient came with left ankle swelling over lateral malleolar region with subsequent episodes of pain during walking. Radiographic investigation suggestive of Ggiant cell tumour which was managed by en block resection of tumour with reconstruction of lateral malleolus using a proximal fibular graft, harvested from same side with protecting the neurovascular structures and used it as a newly reconstructed lateral malleolus with proper fixation. Conclusion: Post -operative functional outcome was estimated by using AOFAS score with radiographic evaluation of ankle mortis. Both implied a satisfactory outcome which conclude that though a giant cell tumour localized on the lateral malleolus are rare, but it can be managed by en bloc resection and restore the ankle biomechanics with a reverse proximal fibular graft.

16.
J Mater Chem B ; 2020 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-32902559

RESUMEN

Nanosystems have shown encouraging outcomes and substantial progress in the areas of drug delivery and biomedical applications. However, the controlled and targeted delivery of drugs or genes can be limited due to their physicochemical and functional properties. In this regard, core-shell type nanoparticles are promising nanocarrier systems for controlled and targeted drug delivery applications. These functional nanoparticles are emerging as a particular class of nanosystems because of their unique advantages, including high surface area, and easy surface modification and functionalization. Such unique advantages can facilitate the use of core-shell nanoparticles for the selective mingling of two or more different functional properties in a single nanosystem to achieve the desired physicochemical properties that are essential for effective targeted drug delivery. Several types of core-shell nanoparticles, such as metallic, magnetic, silica-based, upconversion, and carbon-based core-shell nanoparticles, have been designed and developed for drug delivery applications. Keeping the scope, demand, and challenges in view, the present review explores state-of-the-art developments and advances in core-shell nanoparticle systems, the desired structure-property relationships, newly generated properties, the effects of parameter control, surface modification, and functionalization, and, last but not least, their promising applications in the fields of drug delivery, biomedical applications, and tissue engineering. This review also supports significant future research for developing multi-core and shell-based functional nanosystems to investigate nano-therapies that are needed for advanced, precise, and personalized healthcare systems.

17.
ACS Appl Mater Interfaces ; 10(35): 29918-29924, 2018 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-30091895

RESUMEN

Soft and stretchable electronics are promising for a variety of applications such as wearable electronics, human-machine interfaces, and soft robotics. These devices, which are often encased in elastomeric materials, maintain or adjust their functionality during deformation, but can fail catastrophically if extended too far. Here, we report new functional composites in which stretchable electronic properties are coupled to molecular mechanochromic function, enabling at-a-glance visual cues that inform user control. These properties are realized by covalently incorporating a spiropyran mechanophore within poly(dimethylsiloxane) to indicate with a visible color change that a strain threshold has been reached. The resulting colorimetric elastomers can be molded and patterned so that, for example, the word "STOP" appears when a critical strain is reached, indicating to the user that further strain risks device failure. We also show that the strain at color onset can be controlled by layering silicones with different moduli into a composite. As a demonstration, we show how color onset can be tailored to indicate a when a specified frequency of a stretchable liquid metal antenna has been reached. The multiscale combination of mechanochromism and soft electronics offers a new avenue to empower user control of strain-dependent properties for future stretchable devices.

18.
ACS Nano ; 12(6): 5482-5488, 2018 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-29741864

RESUMEN

Flexible and stretchable electronics are poised to enable many applications that cannot be realized with traditional, rigid devices. One of the most promising options for low-cost stretchable transistors are printed carbon nanotubes (CNTs). However, a major limiting factor in stretchable CNT devices is the lack of a stable and versatile contact material that forms both the interconnects and contact electrodes. In this work, we introduce the use of eutectic gallium-indium (EGaIn) liquid metal for electrical contacts to printed CNT channels. We analyze thin-film transistors (TFTs) fabricated using two different liquid metal deposition techniques-vacuum-filling polydimethylsiloxane (PDMS) microchannel structures and direct-writing liquid metals on the CNTs. The highest performing CNT-TFT was realized using vacuum-filled microchannel deposition with an in situ annealing temperature of 150 °C. This device exhibited an on/off ratio of more than 104 and on-currents as high as 150 µA/mm-metrics that are on par with other printed CNT-TFTs. Additionally, we observed that at room temperature the contact resistances of the vacuum-filled microchannel structures were 50% lower than those of the direct-write structures, likely due to the poor adhesion between the materials observed during the direct-writing process. The insights gained in this study show that stretchable electronics can be realized using low-cost and solely solution processing techniques. Furthermore, we demonstrate methods that can be used to electrically characterize semiconducting materials as transistors without requiring elevated temperatures or cleanroom processes.

19.
Small ; 14(20): e1704460, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29659190

RESUMEN

Buckling instabilities generate microscale features in thin films in a facile manner. Buckles can form, for example, by heating a metal/polymer film stack on a rigid substrate. Thermal expansion differences of the individual layers generate compressive stress that causes the metal to buckle over the entire surface. The ability to dictate and confine the location of buckle formation can enable patterns with more than one length scale, including hierarchical patterns. Here, sacrificial "ink" patterned on top of the film stack localizes the buckles via two mechanisms. First, stiff inks suppress buckles such that only the non-inked regions buckle in response to infrared light. The metal in the non-inked regions absorbs the infrared light and thus gets sufficiently hot to induce buckles. Second, soft inks that absorb light get hot faster than the non-inked regions and promote buckling when exposed to visible light. The exposed metal in the non-inked regions reflects the light and thus never get sufficiently hot to induce buckles. This second method works on glass substrates, but not silicon substrates, due to the superior thermal insulation of glass. The patterned ink can be removed, leaving behind hierarchical patterns consisting of regions of buckles among non-buckled regions.

20.
ACS Appl Mater Interfaces ; 10(13): 11261-11268, 2018 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-29578686

RESUMEN

This paper identifies and characterizes silicone elastomers that are well-suited for fabricating highly stretchable and tear-resistant devices that require interfacial bonding by plasma or UV ozone treatment. The ability to bond two or more pieces of molded silicone is important for creating microfluidic channels, chambers for pneumatically driven soft robotics, and other soft and stretchable devices. Sylgard-184 is a popular silicone, particularly for microfluidic applications. However, its low elongation at break (∼100% strain) and moderate tear strength (∼3 N/mm) make it unsuitable for emerging, mechanically demanding applications of silicone. In contrast, commercial silicones, such as Dragon Skin, have excellent mechanical properties yet are difficult to plasma-bond, likely because of the presence of silicone oils that soften the network yet migrate to the surface and interfere with plasma bonding. We found that extracting silicone oligomers from these soft networks allows these materials to bond but only when the Shore hardness exceeds a value of 15 A. It is also possible to mix highly stretchable silicones (Dragon Skin and Ecoflex) with Sylgard-184 to create silicones with intermediate mechanical properties; interestingly, these blends also only bond when the hardness exceeds 15 A. Eight different Pt-cured silicones were also screened; again, only those with Shore hardness above 15 A plasma-bond. The most promising silicones from this study are Sylgard-186 and Elastosil-M4130 and M4630, which exhibit a large deformation (>200% elongation at break), high tear strength (>12 N/mm), and strong plasma bonding. To illustrate the utility of these silicones, we created stretchable electrodes by injecting a liquid metal into microchannels created using such silicones, which may find use in soft robotics, electronic skin, and stretchable energy storage devices.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...