Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Chim Acta ; 528: 29-33, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35051425

RESUMEN

BACKGROUND AND AIM: Myasthenia gravis (MG) is a B lymphocyte-mediated disease affecting neuromuscular transmission. The clinical course of MG is unpredictable due to the fluctuating nature and heterogeneity of the disease. Increased levels of free light chains (FLC), which reflect B cell activation, have been detected in different autoimmune disorders. In this study, we evaluated the potential role of FLC as diagnostic and prognostic biomarkers of MG. MATERIALS AND METHODS: 74 MG patients and 52 healthy individuals were included in the study. Serum FLC levels were measured by turbidimetric assay (Freelite, The Binding Site Group Ltd) on the Optilite Analyser System in both groups. In MG patients, anti-AChR and anti-MuSK autoantibodies were detected by enzyme-linked immunosorbent assay. RESULTS: MG patients displayed significantly higher serum κ and total FLC levels than controls, respectively for κFLC 16.0 vs 13.8 mg/L and for total FLC 29.8 vs 25.9 mg/L. Moreover, increased κFLC levels were observed in seropositive MG patients. No association was observed between serum FLC levels and clinical manifestations of disease as well as with severity, age at MG onset, thymoma and treatment. CONCLUSION: Increased levels of κFLC and total FLC could serve as biomarkers to support the diagnosis of MG.


Asunto(s)
Cadenas Ligeras de Inmunoglobulina , Miastenia Gravis , Autoanticuerpos , Biomarcadores , Humanos , Miastenia Gravis/diagnóstico , Nefelometría y Turbidimetría
2.
Lab Med ; 51(4): 402-407, 2020 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-31943078

RESUMEN

OBJECTIVE: To assess the usefulness of the κ free light chain index (κFLCi) as a screening test to identify patients with suspected MS. METHODS: The study included 56 patients with a request to test for oligoclonal bands (OCBs). OCBs were detected by isoelectric focusing, followed by immunofixation. Cerebrospinal fluid (CSF) and serum κFLC were measured by a turbidimetric assay. Also, the κFLC index (κFLCi) was calculated. RESULTS: CSF κFLC levels and κFLCi were significantly higher in patients with multiple sclerosis (MS) than in patients with other neurological diseases (NDs; P < .001 and P < .001, respectively). At the cutoff value of 2.9, the κFLCi detected MS with sensitivity of 97% and specificity of 65%. Overall, 92% patients with κFLCi of 2.9 or greater and who had tested positive for OCBs were diagnosed as having MS. CONCLUSION: Our findings support the use of κFLCi as a screening test when MS is suspected, followed by OCB detection as a confirmatory test for the diagnosis of MS.


Asunto(s)
Cadenas Ligeras de Inmunoglobulina/líquido cefalorraquídeo , Esclerosis Múltiple/líquido cefalorraquídeo , Adulto , Anciano , Biomarcadores/sangre , Biomarcadores/líquido cefalorraquídeo , Femenino , Humanos , Cadenas Ligeras de Inmunoglobulina/sangre , Masculino , Tamizaje Masivo/métodos , Tamizaje Masivo/normas , Persona de Mediana Edad , Esclerosis Múltiple/sangre , Esclerosis Múltiple/diagnóstico , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA