Clin Chem Lab Med ; 62(2): 303-311, 2024 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-37732424

RESUMEN

OBJECTIVES: Implementation of alternate erythrocyte sedimentation rate (ESR) measurement method is increasing worldwide due to its various advantages. In this study, we aim to evaluate the analytical performance of the BC-780 automated hematology analyzer in measurement of ESR value. METHODS: Analyzer performance including precision study, carryover, sample stability and potential interferences are examined. Samples with ESR values spanning the whole analytical ESR range are included for method comparison study. Samples with different hematocrit (Hct) and mean corpuscular volume (MCV) values are also analyzed and compared with the results obtained from the Westergren reference method. RESULTS: Precisions and carryover results are consistent with the manufacturers' claim. ESR values do not change significantly in the samples stored at 2-8 °C for 24 h (h) or at room temperature (RT) for 8 h, but significantly decreased (p<0.001) when stored at RT for 24 h. Significant increase in ESR value is documented in samples that are hemolyzed (hemoglobin concentration ranged from 1.28-6.01 g/L) (p=0.010) or lipemic (triglyceride above 4.75 mmol/L) (p=0.001). Method comparison study yields a proportional difference with a regression equation=3.08+ 0.98x. Bland-Altman analysis shows a mean absolute bias of 3.12 mm. The obtained absolute mean biases are below 5 mm in all analytical categories except for the group where MCV>100 fL. CONCLUSIONS: Most tested parameters met the manufacturer's specifications and were comparable to the reference method. Despite the presence of positive bias, it falls within acceptable criteria. Extensive validation against potential interferences such as hemolysis/lipemia is still necessary in future.


Asunto(s)
Hematología , Humanos , Sedimentación Sanguínea , Hematología/métodos , Proyectos de Investigación , Hemólisis , Hematócrito
2.
Clin Chem Lab Med ; 62(4): 690-697, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37855253

RESUMEN

OBJECTIVES: Automated hematology analysis is expected to improve the performance of platelet counting. We evaluated the performance of a new platelet counting, hybrid (PLT-H) and also impedance (PLT-I) and optical (PLT-O) on the BC-780 automated hematology analyzer compared to the international reference method (IRM) in blood samples with thrombocytopenic and platelet interference. METHODS: The basic platelet count performance of the BC-780 automated hematology analyzer was evaluated according to the requirements of the Clinical Laboratory and Standards Institute (CLSI) Document H26-A2. Additionally, the thrombocytopenic (low PLT count) blood samples and the platelet interference blood samples including fragmented red blood cells (RBCs), microcytes or small RBCs, and giant platelets were determined with the BC-780 hematology analyzer compared to the IRM. RESULTS: Blank counting and the carry-over contamination rate of platelet count using the BC-780 both met the manufacturers' claim. For both 123 thrombocytopenic and 232 platelet interference blood samples (72 fragmented RBCs, 91 microcytes and 51 giant platelets), all three platelet counting methods exhibited high comparability with the IRM (the lowest correlation (r)=0.916). Interestingly, the comparability of PLT-H (r=0.928-0.986) with the IRM was better than that of PLT-I (r=0.916-0.979). CONCLUSIONS: The performance of PLT-H in the BC-780 met the manufacturer's specifications. PLT-H exhibits better reproducibility than did PLT-I, correlates well with the PLT-O for thrombocytopenic samples and demonstrates good anti-interference ability. PLT-H counting is therefore recommended as a zero-cost alternative platelet counting method for platelet interference samples in clinical settings.


Asunto(s)
Agmatina/análogos & derivados , Hematología , Ácido Oxámico/análogos & derivados , Humanos , Recuento de Plaquetas/métodos , Reproducibilidad de los Resultados , Hematología/métodos , Plaquetas
3.
Transfus Med ; 32(4): 293-298, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35534916

RESUMEN

BACKGROUND: Recent studies revealed the glucose-6-phosphate dehydrogenase (G-6-PD) deficiency prevalence of 7.7-10% among Thai blood donors. Transfusion of red blood cells (RBCs) from these subjects potentially causes haemolysis in recipients. METHODS: RBC units from the National Blood Centre were sampled to assess G-6-PD levels using spectrophotometry. Patients with pure underproduction anaemia requiring blood transfusion were randomised to receive G-6-PD-deficient versus normal ABO-matched RBCs. Pre- and 48-h post-transfusion indirect bilirubin, haemoglobin, haematocrit, lactate dehydrogenase (LDH) and haptoglobin were measured. RESULTS: From April 2020 to March 2021, 374 RBC units were tested for G-6-PD, and that 25 were found to be G-6-PD deficient. Twelve units of G-6-PD-deficient RBCs and 14 units of normal RBCs were given to patients who met the inclusion criteria. The median (interquartile range) increases of indirect bilirubin in G-6-PD-deficient (N = 11) versus normal RBCs (N = 13) were + 0.12 (0.27) versus + 0.01 (1.3) mg/dl, p = 0.030), respectively. The median increases of haemoglobin were 1.00 (0.50) versus + 0.80 (0.95), p = 0.910, respectively. The increases in haematocrit were 2.59 (1.9) versus 2.29 (2.1), p = 0.733, respectively. There were no significant differences in changes of LDH and haptoglobin levels and no transfusion reactions. DISCUSSION: G-6-PD-deficient packed red cells were associated with mildly elevated indirect bilirubin after transfusion, but there was no observed clinical symptoms.


Asunto(s)
Anemia , Deficiencia de Glucosafosfato Deshidrogenasa , Anemia/terapia , Bilirrubina , Transfusión de Eritrocitos , Glucosafosfato Deshidrogenasa , Deficiencia de Glucosafosfato Deshidrogenasa/diagnóstico , Deficiencia de Glucosafosfato Deshidrogenasa/terapia , Haptoglobinas , Hemoglobinas , Humanos