Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 190
Filtrar
1.
J Artif Organs ; 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38769278

RESUMEN

Preclinical testing using animal models is indispensable in cardiovascular research. However, the translation to clinical practice of these animal models is questionable since it is not always clear how representative they are. This systematic review intends to summarize the interspecies differences in the coagulation profile of animal models used in cardiovascular research. It aims to guide future research in choosing the optimal animal species. A literature search of PubMed, Embase, Web of Science (Core Collection) and Cochrane Library was performed using a search string that was well defined and not modified during the study. An overview of the search terms used in each database can be found in the appendix. Articles describing coagulation systems in large animals were included. We identified 30 eligible studies of which 15 were included. Compared to humans, sheep demonstrated a less active external pathway of coagulation. Sheep had a higher platelet count but the platelet activatability and response to biomaterials were lower. Both sheep and pigs displayed no big differences in the internal coagulation system compared to humans. Pigs showed results very similar to those of humans, with the exception of a higher platelet count and stronger platelet aggregation in pigs. Coagulation profiles of different species used for preclinical testing show strong variation. Adequate knowledge of these differences is key in the selection of the appropriate species for preclinical cardiovascular research. Future thrombogenicity research should compare sheep to pig in an identical experimental setup.

2.
Comput Biol Med ; 176: 108604, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38761502

RESUMEN

OBJECTIVE: In young patients, aortic valve disease is often treated by placement of a pulmonary autograft (PA) which adapts to its new environment through growth and remodeling. To better understand the hemodynamic forces acting on the highly distensible PA in the acute phase after surgery, we developed a fluid-structure interaction (FSI) framework and comprehensively compared hemodynamics and wall shear-stress (WSS) metrics with a computational fluid dynamic (CFD) simulation. METHODS: The FSI framework couples a prestressed non-linear hyperelastic arterial tissue model with a fluid model using the in-house coupling code CoCoNuT. Geometry, material parameters and boundary conditions are based on in-vivo measurements. Hemodynamics, time-averaged WSS (TAWSS), oscillatory shear index (OSI) and topological shear variation index (TSVI) are evaluated qualitatively and quantitatively for 3 different sheeps. RESULTS: Despite systolic-to-diastolic volumetric changes of the PA in the order of 20 %, the point-by-point correlation of TAWSS and OSI obtained through CFD and FSI remains high (r > 0.9, p < 0.01) for TAWSS and (r > 0.8, p < 0.01) for OSI). Instantaneous WSS divergence patterns qualitatively preserve similarities, but large deformations of the PA leads to a decrease of the correlation between FSI and CFD resolved TSVI (r < 0.7, p < 0.01). Moderate co-localization between FSI and CFD is observed for low thresholds of TAWSS and high thresholds of OSI and TSVI. CONCLUSION: FSI might be warranted if we were to use the TSVI as a mechano-biological driver for growth and remodeling of PA due to varying intra-vascular flow structures and near wall hemodynamics because of the large expansion of the PA.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38637938

RESUMEN

OBJECTIVES: Mechanical valves still require life-long anticoagulation. Preclinical animal testing is a crucial step in the assessment of valves; however, the chosen animal model should be carefully considered, and a well-controlled animal model of mechanical valve thrombosis has not been established yet. In this study, a histopathologic comparison was performed to evaluate the representativity of pigs and sheep as large animal models in bileaflet mechanical valve thrombosis research. METHODS: 10 pigs and 8 sheep were implanted with a bileaflet mechanical valve in pulmonary position. During follow-up, no anticoagulative therapy was administered. Pigs were sacrificed between 14 and 38 days for explantation and assessment of the valve. Sheep were sacrificed between 71 and 155 days. Thrombus samples were processed and (immuno)histochemical stainings were applied. A pathologist evaluated the samples morphologically and semiquantitatively and compared these samples to available slides from 3 human patients who underwent redo surgery for acute bileaflet mechanical valve thrombosis, caused by insufficient anticoagulation. RESULTS: All pigs showed macroscopically evident thrombi on the mechanical valve surface at sacrifice. In contrast, none of the sheep showed any sign of thrombus formation. Histology showed a high fibrin content in thrombi of both human and porcine cases (3/3 vs 8/10). Porcine thrombi showed more cellular organization (0/3 vs 6/10), more calcification (0/3 vs 9/10) and more endothelialization (0/3 vs 6/10). Inflammatory cells were present in all samples and were considered physiological. CONCLUSIONS: Contrary to sheep, pigs develop thrombi on their mechanical valves in the short-term if no anticoagulation is administered. Histologic comparison of human and porcine thrombi shows comparable findings. The pig model might serve interestingly for further research on valve thrombosis, if it shows not to be an overly aggressive model.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38688452

RESUMEN

OBJECTIVES: Randomized controlled trials comparing transcatheter aortic valve implantation with surgical aortic valve replacement demonstrate conflicting evidence, particularly in low-risk patients. We aim to reevaluate the evidence using trial sequential analysis, balancing type I and II errors, and compare with conventional meta-analysis. METHODS: Databases were searched for randomized controlled trials, which were divided into higher-risk and lower-risk randomized controlled trials according to a pragmatic risk classification. Primary outcomes were death and a composite end point of death or disabling stroke assessed at 1 year and maximum follow-up. Conventional meta-analysis and trial sequential analysis were performed, and the required information size was calculated considering a type I error of 5% and a power of 90%. RESULTS: Eight randomized controlled trials (n = 5274 higher-risk and 3661 lower-risk patients) were included. Higher-risk trials showed no significant reduction in death at 1 year with transcatheter aortic valve implantation (relative risk, 0.93, 95% CI, 0.81-1.08, P = .345). Lower-risk trials suggested lower death risk on conventional meta-analysis (relative risk, 0.67, 95% CI, 0.47-0.96, P = .031), but trial sequential analysis indicated potential spurious evidence (P = .116), necessitating more data for conclusive benefit (required information size = 5944 [59.8%]). For death or disabling stroke at 1 year, higher-risk trials lacked evidence (relative risk, 0.90, 95% CI, 0.79-1.02, P = .108). In lower-risk trials, transcatheter aortic valve implantation indicated lower risk in conventional meta-analysis (relative risk, 0.68, 95% CI, 0.50-0.93, P = .014), but trial sequential analysis suggested potential spurious evidence (P = .053), necessitating more data for conclusive benefit (required information size = 5122 [69.4%]). Follow-up results provided inconclusive evidence for both primary outcomes across risk categories. CONCLUSIONS: Conventional meta-analysis methods may have prematurely declared an early reduction of negative outcomes after transcatheter aortic valve implantation when compared with surgical aortic valve replacement.

5.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38532286

RESUMEN

OBJECTIVES: Decellularized aortic homografts (DAH) were introduced in 2008 as a further option for paediatric aortic valve replacement (AVR). METHODS: Prospective, multicentre follow-up of all paediatric patients receiving DAH for AVR in 8 European centres. RESULTS: A total of 143 DAH were implanted between February 2008 and February 2023 in 137 children (106 male, 74%) with a median age of 10.8 years (interquartile range 6.6-14.6). Eighty-four (59%) had undergone previous cardiac operations and 24 (17%) had undergone previous AVR. The median implanted DAH diameter was 21 mm (interquartile range 19-23). The median operation duration was 348 min (227-439) with a median cardiopulmonary bypass time of 212 min (171-257) and a median cross-clamp time of 135 min (113-164). After a median follow-up of 5.3 years (3.3-7.2, max. 15.2 years), the primary efficacy end-points peak gradient (median 14 mmHg, 9-28) and regurgitation (median 0.5, interquartile range 0-1, grade 0-3) showed good results but an increase over time. Freedom from death/explantation/endocarditis/bleeding/thromboembolism at 5 years were 97.8 ± 1.2/88.7 ± 3.3/99.1 ± 0.9/100 and 99.2 ± 0.8%, respectively. Freedom from death/explantation/endocarditis/bleeding/thromboembolism at 10 years were 96.3 ± 1.9/67.1 ± 8.0/93.6 ± 3.9/98.6 ± 1.4 and 86.9 ± 11.6%, respectively. In total, 21 DAH were explanted. Seven were replaced by a mechanical AVR, 1 Ross operation was performed and a re-do DAH was implanted in 13 patients with no redo mortality. The calculated expected adverse events were lower for DAH compared to cryopreserved homograft patients (mean age 8.4 years), and in the same range as for Ross patients (9.2 years) and mechanical AVR (13.0 years). CONCLUSIONS: This large-scale prospective analysis demonstrates excellent mid-term survival using DAH with adverse event rates comparable to paediatric Ross procedures.


Asunto(s)
Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Tromboembolia , Niño , Humanos , Masculino , Aloinjertos/cirugía , Válvula Aórtica/cirugía , Endocarditis/cirugía , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Reoperación , Resultado del Tratamiento , Femenino , Adolescente
6.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38532304

RESUMEN

OBJECTIVES: Decellularized aortic homografts (DAH) were introduced as a new option for aortic valve replacement for young patients. METHODS: A prospective, EU-funded, single-arm, multicentre study in 8 centres evaluating non-cryopreserved DAH for aortic valve replacement. RESULTS: A total of 144 patients (99 male) were prospectively enrolled in the ARISE Trial between October 2015 and October 2018 with a median age of 30.4 years [interquartile range (IQR) 15.9-55.1]; 45% had undergone previous cardiac operations, with 19% having 2 or more previous procedures. The mean implanted DAH diameter was 22.6 mm (standard deviation 2.4). The median operation duration was 312 min (IQR 234-417), the median cardiopulmonary bypass time was 154 min (IQR 118-212) and the median cross-clamp time 121 min (IQR 93-150). No postoperative bypass grafting or renal replacement therapy were required. Two early deaths occurred, 1 due to a LCA thrombus on day 3 and 1 due ventricular arrhythmia 5 h postoperation. There were 3 late deaths, 1 death due to endocarditis 4 months postoperatively and 2 unrelated deaths after 5 and 7 years due to cancer and Morbus Wegener resulting in a total mortality of 3.47%. After a median follow-up of 5.9 years [IQR 5.1-6.4, mean 5.5 years. (standard deviation 1.3) max. 7.6 years], the primary efficacy end-points peak gradient with median 11.0 mmHg (IQR 7.8-17.6) and regurgitation of median 0.5 (IQR 0-0.5) of grade 0-3 were excellent. At 5 years, freedom from death/reoperation/endocarditis/bleeding/thromboembolism were 97.9%/93.5%/96.4%/99.2%/99.3%, respectively. CONCLUSIONS: The 5-year results of the prospective multicentre ARISE trial continue to show DAH to be safe for aortic valve replacement with excellent haemodynamics.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Adulto , Humanos , Masculino , Aloinjertos/cirugía , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Endocarditis/cirugía , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Prospectivos , Reoperación , Datos de Salud Recolectados Rutinariamente , Femenino , Adolescente , Adulto Joven , Persona de Mediana Edad
7.
Artículo en Inglés | MEDLINE | ID: mdl-38447197

RESUMEN

OBJECTIVES: To investigate if there is still a place for bioprosthetic mitral valve replacement in children by comparing the prosthetic durability and transplant-free survival after bioprosthetic and mechanical mitral valve replacement. METHODS: We reviewed all mitral valve replacements in children between 1981 and 2020. Bioprosthetic mitral valve replacement cases were individually matched to mechanical mitral valve replacement cases. The incidence rate of a 2nd replacement was calculated using the cumulative incidence function that considered death or transplantation as a competing risk. RESULTS: The median age at implantation was 3.6 years (interquartile range 0.8-7.9) for the bioprosthetic valve cohort (n = 28) and 3 years (interquartile range 1.3-7.8) for the mechanical valve cohort (n = 28). Seven years after bioprosthetic mitral valve replacement, the cumulative incidence of death or transplantation was 17.9% [95% confidence interval (CI) 6.3-34.1] and the cumulative incidence of a 2nd replacement was 63.6% (95% CI 39.9-80.1). Seven years after mechanical mitral valve replacement, the cumulative incidence of death or transplantation was 28.6% (95% CI 13.3-46) and the cumulative incidence of a 2nd replacement was 10.7% (95% CI 2.6-25.5). Fifteen years after mechanical mitral valve replacement, the cumulative incidence of death or transplantation was 33.6% (95% CI 16.2-52.1) and the cumulative incidence of a 2nd replacement was 41.1% (95% CI 18.4-62.7). The cumulative incidence curves for bioprosthetic and mechanical mitral valve replacement were statistically different for a 2nd valve replacement (P < 0.001) but not for death or transplantation (P = 0.33). CONCLUSIONS: There is no difference in transplant-free survival after bioprosthetic and mechanical mitral valve replacement in children. The lifespan of bioprosthetic mitral valves remains limited in children because of structural valve failure due to calcification. After 15 years, 40% of mechanical valves were replaced, primarily because of patient-prosthesis mismatch related to somatic growth.

8.
J Cardiovasc Dev Dis ; 11(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38392263

RESUMEN

During the Renaissance, Leonardo Da Vinci was the first person to successfully detail the anatomy of the aortic root and its adjacent structures. Ever since, novel insights into morphology, function, and their interplay have accumulated, resulting in advanced knowledge on the complex functional characteristics of the aortic valve (AV) and root. This has shifted our vision from the AV as being a static structure towards that of a dynamic interconnected apparatus within the aortic root as a functional unit, exhibiting a complex interplay with adjacent structures via both humoral and mechanical stimuli. This paradigm shift has stimulated surgical treatment strategies of valvular disease that seek to recapitulate healthy AV function, whereby AV disease can no longer be seen as an isolated morphological pathology which needs to be replaced. As prostheses still cannot reproduce the complexity of human nature, treatment of diseased AVs, whether stenotic or insufficient, has tremendously evolved, with a similar shift towards treatments options that are more hemodynamically centered, such as the Ross procedure and valve-conserving surgery. Native AV and root components allow for an efficient Venturi effect over the valve to allow for optimal opening during the cardiac cycle, while also alleviating the left ventricle. Next to that, several receptors are present on native AV leaflets, enabling messenger pathways based on their interaction with blood and other shear-stress-related stimuli. Many of these physiological and hemodynamical processes are under-acknowledged but may hold important clues for innovative treatment strategies, or as potential novel targets for therapeutic agents that halt or reverse the process of valve degeneration. A structured overview of these pathways and their implications for cardiothoracic surgeons and cardiologists is lacking. As such, we provide an overview on embryology, hemodynamics, and messenger pathways of the healthy and diseased AV and its implications for clinical practice, by relating this knowledge to current treatment alternatives and clinical decision making.

9.
Cell Tissue Bank ; 25(1): 55-66, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36917328

RESUMEN

For decades, bovine jugular vein conduits (BJV) and classic cryopreserved homografts have been the two most widely used options for pulmonary valve replacement (PVR) in congenital heart disease. More recently, decellularized pulmonary homografts (DPH) have provided an alternative avenue for PVR. Matched comparison of patients who received DPH for PVR with patients who received bovine jugular vein conduits (BJV) considering patient age group, type of heart defect, and previous procedures. 319 DPH patients were matched to 319 BJV patients; the mean age of BJV patients was 15.3 (SD 9.5) years versus 19.1 (12.4) years in DPH patients (p = 0.001). The mean conduit diameter was 24.5 (3.5) mm for DPH and 20.3 (2.5) mm for BJV (p < 0.001). There was no difference in survival rates between the two groups after 10 years (97.0 vs. 98.1%, p = 0.45). The rate of freedom from endocarditis was significantly lower for BJV patients (87.1 vs. 96.5%, p = 0.006). Freedom from explantation was significantly lower for BJV at 10 years (81.7 vs. 95.5%, p = 0.001) as well as freedom from any significant degeneration at 10 years (39.6 vs. 65.4%, p < 0.001). 140 Patients, matched for age, heart defect type, prior procedures, and conduit sizes of 20-22 mm (± 2 mm), were compared separately; mean age BJV 8.7 (4.9) and DPH 9.5 (7.3) years (p = n.s.). DPH showed 20% higher freedom from explantation and degeneration in this subgroup (p = 0.232). Decellularized pulmonary homografts exhibit superior 10-year results to bovine jugular vein conduits in PVR.


Asunto(s)
Cardiopatías Congénitas , Válvula Pulmonar , Humanos , Bovinos , Animales , Lactante , Adolescente , Niño , Válvula Pulmonar/trasplante , Venas Yugulares/trasplante , Resultado del Tratamiento , Cardiopatías Congénitas/cirugía , Aloinjertos , Estudios Retrospectivos
10.
J Thorac Dis ; 15(11): 6301-6316, 2023 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-38090325

RESUMEN

Background: Extracorporeal life support (ECLS) is not routinely used at our center during sequential single-lung transplantation (LTx), but is restricted to anticipate and overcome hemodynamic and respiratory problems occurring peri-operatively. In this retrospective descriptive cohort study, we aim to describe our single-center experience with ECLS in LTx, analyzing ECLS-related complications. Methods: All transplantations with peri-operative ECLS use [2010-2020] were retrospectively analyzed. Multi-organ and heart-lung transplantation were excluded. Demographics, support type and indications are described. Complications are categorized according to the underlying nature and type. Data are presented as median [interquartile range (IQR)]. Kaplan-Meier was used for survival analysis. Results: The overall use of ECLS was 22% (156/703 patients) with a mean age of 52 years (IQR, 36-59 years). Transplant indications in ECLS cohort were interstitial lung disease (38%; n=60), chronic obstructive pulmonary disease (COPD) (19%; n=29), cystic fibrosis (17%; n=26) and others (26%; n=41). Per indication, 94% (15/16) of pulmonary arterial hypertension patients required ECLS, whereas only 8% (29/382) of COPD patients did. In 16% (25/156) of supported patients, veno-venous extracorporeal membrane oxygenation was initiated, while 77% (120/156) required veno-arterial support, and 7% (11/156) cardiopulmonary bypass. Thirty-day mortality was 6% (9/156). Sixteen percent (25/156) of patients were bridged to transplantation on ECLS and 24% (37/156) required post-operative support. Main reasons to use ECLS were intra-operative hemodynamic instability (53%; n=82), ventilation/oxygenation problems (22%; n=34) and reperfusion edema (17%; n=26). Overall incidence of patients with at least one ECLS-related complication was 67% (n=104). Most common complications were hemothorax (25%; n=39), need for continuous renal replacement therapy (19%; n=30), and thromboembolism (14%; n=22). Conclusions: ECLS was required in 22% of LTxs, with a reported ECLS-related complication rate of 67%, of which the most common was hemothorax. Larger databases are needed to further analyze complications and develop tailored deployment strategies for ECLS-use in LTx.

11.
BMJ Open ; 13(12): e073729, 2023 12 28.
Artículo en Inglés | MEDLINE | ID: mdl-38154894

RESUMEN

INTRODUCTION: Ischaemic cold static storage (ICSS) is the gold standard in donor heart preservation. This ischaemic time frame renders a time constraint and risk for primary graft dysfunction. Cold oxygenated heart perfusion, known as non-ischaemic heart preservation (NIHP), theoretically limits the ischaemic time, while holding on to the known advantage of hypothermia and cardioplegia, a low metabolic rate. METHODS AND ANALYSIS: The NIHP 2019 study is an international, randomised, controlled, open, multicentre clinical trial in 15 heart transplantation centres in 8 European countries and includes 202 patients undergoing heart transplantation, allocated 1:1 to NIHP or ICSS. Enrolment is estimated to be 30 months after study initiation. The patients are followed for 12 months after transplantation.The primary objective is to evaluate the effect of NIHP on survival, allograft function and rejection episodes within the first 30 days after transplantation. The secondary objectives are to compare treatment groups with respect to survival, allograft function, cardiac biomarkers, rejection episodes, allograft vasculopathy, adverse events and adverse device effects within 12 months. ETHICS AND DISSEMINATION: This protocol was approved by the Ethics Committee (EC) for Research UZ/KU Leuven, Belgium, the coordinating EC in Germany (Bei Der LMU München), the coordinating EC in the UK (West Midlands-South Birmingham Research), the EC of Hospital Puerta de Hierro, Madrid, Spain, the EC of Göteborg, Sweden, the coordinating EC in France, the EC of Padova, Italy and the EC of the University of Vienna, Austria. This study will be conducted in accordance with current local regulations and international applicable regulatory requirements according to the principles of the Declaration of Helsinki and ISO14155:2020. Main primary and secondary outcomes will be published on modified intention-to-treat population and per-protocol population. TRIAL REGISTRATION NUMBER: NCT03991923.


Asunto(s)
Trasplante de Corazón , Humanos , Donantes de Tejidos , Europa (Continente) , Trasplante Homólogo , Criopreservación/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Multicéntricos como Asunto
12.
Eur Heart J ; 44(44): 4665-4674, 2023 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-37936176

RESUMEN

BACKGROUND AND AIMS: Given limited evidence and lack of consensus on donor acceptance for heart transplant (HT), selection practices vary widely across HT centres in the USA. Similar variation likely exists on a broader scale-across countries and HT systems-but remains largely unexplored. This study characterized differences in heart donor populations and selection practices between the USA and Eurotransplant-a consortium of eight European countries-and their implications for system-wide outcomes. METHODS: Characteristics of adult reported heart donors and their utilization (the percentage of reported donors accepted for HT) were compared between Eurotransplant (n = 8714) and the USA (n = 60 882) from 2010 to 2020. Predictors of donor acceptance were identified using multivariable logistic regression. Additional analyses estimated the impact of achieving Eurotransplant-level utilization in the USA amongst donors of matched quality, using probability of acceptance as a marker of quality. RESULTS: Eurotransplant reported donors were older with more cardiovascular risk factors but with higher utilization than in the USA (70% vs. 44%). Donor age, smoking history, and diabetes mellitus predicted non-acceptance in the USA and, by a lesser magnitude, in Eurotransplant; donor obesity and hypertension predicted non-acceptance in the USA only. Achieving Eurotransplant-level utilization amongst the top 30%-50% of donors (by quality) would produce an additional 506-930 US HTs annually. CONCLUSIONS: Eurotransplant countries exhibit more liberal donor heart acceptance practices than the USA. Adopting similar acceptance practices could help alleviate the scarcity of donor hearts and reduce waitlist morbidity in the USA.


Asunto(s)
Trasplante de Corazón , Donantes de Tejidos , Adulto , Humanos , Europa (Continente)/epidemiología , Modelos Logísticos , Obesidad/epidemiología
13.
J Mech Behav Biomed Mater ; 148: 106170, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37852088

RESUMEN

In the sixties, Dr Donald Ross designed a surgical solution for young patients with aortic valve disease by using the patients' own pulmonary valve. The Ross procedure is the only aortic valve replacement technique that can restore long-term survival and preserve quality of life. The main failure mode of the Ross procedure is wall dilatation, potentially leading to valve regurgitation and leakage. Dilatation occurs due to the inability of the pulmonary autograft to adapt to the sudden increase in loading when exposing to aortic pressures. Previous experimental data has shown that a permanent external support wrapped around the artery can prevent the acute dilatation of the arterial wall. However, the textile support leads to stress-shielding phenomena due to the loss of mechanical wall compliance. We present a pragmatic and modular computational framework of arterial growth and remodeling predicting the long-term outcomes of cardiovascular tissue adaptation, with and without textile wrapping. The model integrates mean, systolic and diastolic pressures and assumes the resulting wall stresses to drive the biological remodeling rules. Rather than a single mean pressure or stress deviation from the homeostatic state, we demonstrate that only pulsatile stresses can predict available experimental results. Therefore, we suggest that a biodegradable external support could induce benign remodeling in the Ross procedure. Indeed, a biodegradable textile wrapped around the autograft fulfills the trade-off between prevention of acute dilatation on the one hand and recovery of arterial wall compliance on the other hand. After further validation, the computational framework can set the basis for the development of an actual biodegradable external support for the Ross procedure with optimized polymer mechanical properties and degradation behavior.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Pulmonar , Humanos , Insuficiencia de la Válvula Aórtica/prevención & control , Insuficiencia de la Válvula Aórtica/cirugía , Autoinjertos , Calidad de Vida , Trasplante Autólogo , Válvula Aórtica/cirugía , Válvula Pulmonar/cirugía , Arteria Pulmonar , Resultado del Tratamiento
14.
Eur J Cardiothorac Surg ; 64(5)2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37756688

RESUMEN

OBJECTIVES: There are several treatment options for non-elderly adults (18-60 years) in need of aortic valve replacement (AVR): a mechanical or biological substitute, a homograft, the Ross procedure or nowadays even transcatheter aortic valve replacement. This study evaluated the current opinions and practices of cardiac surgeons and cardiologists concerning AVR strategies in this patient group. METHODS: A 43-item online survey was sent out to several scientific organizations, individual cardiac surgeons, cardiologists and residents/fellows worldwide. RESULTS: Two hundred twenty-two physicians from 33 different countries answered the survey. The UK (24%), Belgium (23%) and North America (22%) are best represented. A mechanical valve is the most frequently used substitute in non-elderly. With increasing patient age, the popularity of a biological valve increases. Transcatheter aortic valve replacement and the Ross procedure are each used in <10% of this cohort. Only 12% of the cardiac surgeons has experience with the Ross surgery. In 23%, the patient seems not to be involved in the decision on the type of valve substitute. CONCLUSIONS: The preferred surgical treatment for non-elderly patients in need of AVR differs widely. To enable a shared decision-making process including patient preferences, there is more need for collaboration between cardiac departments, as well as education and scientific research about patient-centred outcomes of the different AVR techniques.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Adulto , Humanos , Persona de Mediana Edad , Válvula Aórtica/cirugía , Estudios Retrospectivos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía
16.
Eur J Cardiothorac Surg ; 64(5)2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37551943

RESUMEN

OBJECTIVES: We sought to assess the evolution of secondary tricuspid regurgitation (TR) after isolated aortic valve replacement (AVR) and its impact on mortality and to identify possible clinical and echocardiographic predictors of persisting and new-onset TR (TR de novo) after isolated AVR. METHODS: Clinical and echocardiographic data of 441 patients, consecutively operated for isolated AVR between January 2017 and January 2020, were retrospectively collected. Four time points were included: preoperative, discharge, 3-6 months and last available follow-up. We followed patients with at least moderate TR (TR ≥2) over time and monitored the impact on survival. Logistic regression analysis was performed to identify possible predictors of persistent TR and TR de novo. RESULTS: Median follow-up was 33 months. Incidence of TR ≥2 changed over the time points. Twenty-three percent of patients with preoperative TR ≥2 had persistent TR at 3-6 months follow-up, and this phenomenon was predicted by age at regression analysis. Preoperative TR ≥2 was associated with a 3-fold higher risk to die. At 3- to 6-month follow-up, 12% of patients developed TR de novo. At least moderate preoperative mitral regurgitation (≥2) was predictive of TR de novo. CONCLUSIONS: Patients with TR ≥2 undergoing isolated AVR had worse long-term survival, and this was particularly evident in the elderly. Older patients were also more prone to have persistent TR after AVR. Some patients developed TR de novo after isolated AVR, but this did not affect survival.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia de la Válvula Tricúspide , Humanos , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/epidemiología , Insuficiencia de la Válvula Tricúspide/etiología , Estudios Retrospectivos , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento
17.
Am Heart J ; 266: 48-60, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37595658

RESUMEN

BACKGROUND: Recently, an expert consensus statement proposed indications where implantation of a primary prevention implantable cardioverter-defibrillator (ICD) may be reasonable in patients with mitral valve prolapse (MVP). The objective was to evaluate the proposed risk stratification by the expert consensus statement. METHODS: Consecutive patients with MVP without alternative arrhythmic substrates with cardiac magnetic resonance imaging (CMR) were included in a single-center retrospective registry. Arrhythmic MVP (AMVP) was defined as a total premature ventricular complex burden ≥5%, non-sustained ventricular tachycardia (VT), VT, or ventricular fibrillation. The end point was a composite of SCD, VT, inducible VT, and appropriate ICD shocks. RESULTS: In total, 169 patients (52.1% male, median age 51.4 years) were included and 99 (58.6%) were classified as AMVP. Multivariate logistic regression identified the presence of late gadolinium enhancement (OR 2.82, 95%CI 1.45-5.50) and mitral annular disjunction (OR 1.98, 95%CI 1.02-3.86) as only predictors of AMVP. According to the EHRA risk stratification, 5 patients with AMVP (5.1%) had a secondary prevention ICD indication, while in 69 patients (69.7%) the implantation of an ICD may be reasonable. During a median follow-up of 8.0 years (IQR 5.0-15.6), the incidence rate for the composite arrhythmic end point was 0.3%/year (95%CI 0.1-0.8). CONCLUSION: More than half of MVP patients referred for CMR met the AMVP diagnostic criteria. Despite low long-term event rates, in 70% of patients with AMVP the implantation of an ICD may be reasonable. Risk stratification of SCD in MVP remains an important knowledge gap and requires urgent investigation.


Asunto(s)
Prolapso de la Válvula Mitral , Complejos Prematuros Ventriculares , Humanos , Masculino , Persona de Mediana Edad , Femenino , Prolapso de la Válvula Mitral/complicaciones , Prolapso de la Válvula Mitral/diagnóstico , Medios de Contraste , Estudios Retrospectivos , Gadolinio , Válvula Mitral , Medición de Riesgo
18.
Artículo en Inglés | MEDLINE | ID: mdl-37584674

RESUMEN

OBJECTIVES: We present the long-term results of a trileaflet (Triflo) versus bileaflet (On-X) mechanical valve in both aortic and pulmonary positions in a sheep model. METHODS: The Triflo valve was implanted in 21 female sheep in aortic (n = 8) and pulmonary position (n = 13). The On-X valve was implanted in 7 female sheep in aortic (n = 1) and pulmonary (n = 6) positions. No antithrombotic medication of any kind was given postoperatively. In the aortic group, survival cohorts were 3 and 5 months. In the pulmonary group, survival cohorts were 10 and 20 weeks. Valve performance was assessed using haematology, echocardiography and acoustic measurements combined with post-mortem pathology analysis of the downstream organs. RESULTS: The mean gradients were lower for the Triflo valve in both pulmonary [4.30 mmHg (3.70-5.73) vs 6.80 mmHg (4.63-7.96), P = 0.012] and aortic [5.1 mmHg (4.2-7.7) vs 10.7 mmHg (8.7-12.9), P = 0.007] positions. Peak gradients were lower for the Triflo valve in both pulmonary [8.05 mmHg (6.75-10.23) vs 13.15 mmHg (9.20-14.76), P = 0.005] and aortic [8.7 mmHg (7.5-12.5) vs 16.5 mmHg (14.2-19.6), P = 0.009] positions. In both positions, leaflets and housing surface were free from any deposits macro- and microscopically and comparable to nonimplanted control valves. Peripheral organs showed no signs of thrombo-embolic damage. Biochemical and haematological were comparable to preoperative. The closing click sound pressure level of the Triflo was significantly lower in both aortic [108.4 sound pressure level (102.0-115.7) vs 111.7 sound pressure level (105.5-117.0), P < 0.001] and pulmonary [103.6 sound pressure level (99.1-108.9) vs 118.5 sound pressure level (116.7-120.2), P < 0.001] position. CONCLUSIONS: Preliminary in vivo results of the Triflo valve are promising in both aortic and pulmonary positions in an ovine model. Excellent haemodynamics, stable long-term function, low valve noise and no thrombo-embolic events in the absence of antithrombotic medication lay the foundation to a future clinical first-in-man trial.

19.
J Clin Med ; 12(15)2023 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-37568386

RESUMEN

Valvular heart disease is a common disease often necessitating valve replacement. Mechanical heart valves (MHVs) are often used in younger patients because of their longer durability. Their main disadvantage is the need for lifelong anticoagulation. Warfarin is considered a standard treatment, but it is far from perfect. Direct oral anticoagulants (DOACs) are a new and more patient-friendly alternative to warfarin when anticoagulation is required, but have not yet been approved for the indication of mechanical valves. EVIDENCE ACQUISITION: A literature search of Pubmed, Embase, Web of Science (Core Collection), and Cochrane Library (from inception to May 2023) was performed using a search string that was well defined and not modified during the study. An extensive overview of the search terms used in each database can be found in the Appendix. Only prospective clinical trials were included in this review. A total of 10 publications were included in this review. RELEVANCE TO CLINICAL PRACTICE: This systematic review summarizes the different types of DOACs and their possible use in the anticoagulation of mechanical valves. We aim to propose future directions in anticoagulation research for mechanical valves. CONCLUSIONS: DOAC use in MHVs has been halted due to the failure of both dabigatran and apixaban in two major clinical trials. However, rivaroxaban was successful in two small clinical trials. Ample research is still needed to explore new valve designs as well as new anticoagulation targets.

20.
Eur Heart J ; 44(34): 3231-3246, 2023 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-37366156

RESUMEN

AIMS: To support decision-making in children undergoing aortic valve replacement (AVR), by providing a comprehensive overview of published outcomes after paediatric AVR, and microsimulation-based age-specific estimates of outcome with different valve substitutes. METHODS AND RESULTS: A systematic review of published literature reporting clinical outcome after paediatric AVR (mean age <18 years) published between 1/1/1990 and 11/08/2021 was conducted. Publications reporting outcome after paediatric Ross procedure, mechanical AVR (mAVR), homograft AVR (hAVR), and/or bioprosthetic AVR were considered for inclusion. Early risks (<30d), late event rates (>30d) and time-to-event data were pooled and entered into a microsimulation model. Sixty-eight studies, of which one prospective and 67 retrospective cohort studies, were included, encompassing a total of 5259 patients (37 435 patient-years; median follow-up: 5.9 years; range 1-21 years). Pooled mean age for the Ross procedure, mAVR, and hAVR was 9.2 ± 5.6, 13.0 ± 3.4, and 8.4 ± 5.4 years, respectively. Pooled early mortality for the Ross procedure, mAVR, and hAVR was 3.7% (95% CI, 3.0%-4.7%), 7.0% (5.1%-9.6%), and 10.6% (6.6%-17.0%), respectively, and late mortality rate was 0.5%/year (0.4%-0.7%/year), 1.0%/year (0.6%-1.5%/year), and 1.4%/year (0.8%-2.5%/year), respectively. Microsimulation-based mean life-expectancy in the first 20 years was 18.9 years (18.6-19.1 years) after Ross (relative life-expectancy: 94.8%) and 17.0 years (16.5-17.6 years) after mAVR (relative life-expectancy: 86.3%). Microsimulation-based 20-year risk of aortic valve reintervention was 42.0% (95% CI: 39.6%-44.6%) after Ross and 17.8% (95% CI: 17.0%-19.4%) after mAVR. CONCLUSION: Results of paediatric AVR are currently suboptimal with substantial mortality especially in the very young with considerable reintervention hazards for all valve substitutes, but the Ross procedure provides a survival benefit over mAVR. Pros and cons of substitutes should be carefully weighed during paediatric valve selection.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Niño , Adolescente , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Retrospectivos , Estudios Prospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...