Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
J Electrocardiol ; 82: 69-72, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38042010

RESUMEN

We present a case of a patient with advanced interatrial block who was admitted for cavotricuspid isthmus ablation as treatment of typical atrial flutter. A baseline advanced interatrial block pattern turned into partial interatrial block pattern and prolonged PR interval after the procedure. We discuss the mechanism underlying that change.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Humanos , Sistema de Conducción Cardíaco/cirugía , Resultado del Tratamiento , Bloqueo Interauricular , Electrocardiografía/métodos , Aleteo Atrial/cirugía , Ablación por Catéter/métodos
2.
Am Heart J ; 269: 15-24, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38042457

RESUMEN

BACKGROUND AND OBJECTIVE: Patients with palpitations clinically suggestive of paroxysmal supraventricular tachycardia (PSVT) are often managed conservatively until ECG-documentation of the tachycardia, leading to high impact on life quality and healthcare resource utilization. We evaluated results of electrophysiological study (EPS), and ablation when appropriate, among these patients, with special focus on gender differences in management. METHODS: BELIEVE SVT is a European multicenter, retrospective registry in tertiary hospitals performing EPS in patients with palpitations, without ECG-documentation of tachycardia or preexcitation, and considered highly suggestive of PSVT by a cardiologist or cardiac electrophysiologist. We analyzed clinical characteristics, results of EPS and ablation, complications, and clinical outcomes during follow-up. RESULTS: Six-hundred eighty patients from 20 centers were included. EPS showed sustained tachycardia in 60.9% of patients, and substrate potentially enabling AVNRT in 14.7%. No major/permanent complications occurred. Minor/transient complications were reported in 0.84% of patients undergoing diagnostic-only EPS and 1.8% when followed by ablation. During a 3.4-year follow-up, 76.2% of patients remained free of palpitations recurrence. Ablation (OR: 0.34, P < .01) and male gender (OR: 0.58, P = .01) predicted no recurrence. Despite a higher female proportion among patients with recurrence, (77.2% vs 63.5% among those asymptomatic during follow-up, P < .01), 73% of women in this study reported no recurrence of palpitations after EPS. CONCLUSIONS: EPS and ablation are safe and effective in preventing recurrence of nondocumented palpitations clinically suggestive of PSVT. Despite a lower efficacy, this strategy is also highly effective among women and warrants no gender differences in management.


Asunto(s)
Ablación por Catéter , Taquicardia Paroxística , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Masculino , Femenino , Estudios Retrospectivos , Carga Sintomática , Taquicardia Paroxística/diagnóstico , Arritmias Cardíacas/cirugía , Sistema de Registros
3.
ESC Heart Fail ; 10(6): 3700-3709, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37731197

RESUMEN

AIMS: Atrial fibrillation (AF) worsens the prognosis of patients with heart failure (HF). Successful treatments are still very scarce for those with permanent AF and preserved (HFpEF) or mildly reduced (HFmrEF) ejection fraction. In this study, the long-term benefits and safety profile of heart rate regularization through left-bundle branch pacing (LBBP) and atrioventricular node ablation (AVNA) will be explored in comparison with pharmacological rate-control strategy. METHODS AND RESULTS: The PACE-FIB trial is a multicentre, prospective, open-label, randomized (1:1) clinical study that will take place between March 2022 and February 2027. A total of 334 patients with HFpEF/HFmrEF and permanent AF will receive either LBBP followed by AVNA (intervention arm) or optimal pharmacological treatment for heart rate control according to European guideline recommendations (control arm). All patients will be followed up for a minimum of 36 months. The primary outcome measure will be the composite of all-cause mortality, HF hospitalization, and worsening HF at 36 months. Other secondary efficacy and safety outcome measures such as echocardiographic parameters, functional status, and treatment-related adverse events, among others, will be analysed too. CONCLUSION: LBBP is a promising stimulation mode that may foster the clinical benefit of heart rate regularization through AV node ablation compared with pharmacological rate control. This is the first randomized trial specifically addressing the long-term efficacy and safety of this pace-and-ablate strategy in patients with HFpEF/HFmrEF and permanent AF.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Humanos , Nodo Atrioventricular/cirugía , Estudios Prospectivos , Volumen Sistólico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones
4.
J Arrhythm ; 39(4): 676-680, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37560277

RESUMEN

Background: Compatibility of DiamondTemp (DT) radiofrequency (RF) catheter with the Rhythmia mapping system has not been manufacturer-reported nor its tracking accuracy reported. Methods: Consecutive patients undergoing macroreentrant atrial tachycardia ablation guided by Rhythmia and ablated using DT were prospectively enrolled. Following catheter configuration, ablation lines were performed and remapped to measure the RF tag to effective-ablation-line-center (RFT-ALC) distance. Results: Among 20 consecutive patients (54 maps), 40 ablation lines were evaluated. Overall, the RFT-ALC distance was 3.88 ± 2.95 mm, and the operator assessment of accuracy was high. No complications occurred. Conclusion: The use of DT catheter guided by the Rhythmia mapping system is feasible and accurate.

5.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37497862

RESUMEN

AIMS: Cryoballoon pulmonary vein isolation (CB-PVI) offers similar efficacy to point-by-point radiofrequency PVI for patients with atrial fibrillation (AF), but generally with higher X-ray exposure. Strategies aimed at reducing fluoroscopy mostly rely on other costly imaging techniques, limiting their applicability. We designed a Systematic Workflow and Electrogram guidance to reduce X-ray Exposure Time during CB-PVI (SWEET-Cryo) strategy and analysed its impact on fluoroscopy use and acute procedural and clinical outcomes. METHODS AND RESULTS: We enrolled 100 patients with paroxysmal or persistent AF undergoing CB-PVI by two operators with different levels of expertise. Patients treated with the SWEET-Cryo strategy (prospective cohort; n = 50) or conventional fluoroscopy (retrospective control cohort; n = 50) were compared. When applied by the senior operator, the SWEET-Cryo strategy significantly reduced the mean fluoroscopy time (FT) (2.6 ± 1.25 vs. 20.3 ± 10.8 min) and mean dose area product (DAP) (5.1 ± 3.8 vs. 35.3 ± 22.3 Gy cm2) compared with those of the control group, respectively (P < 0.001). Significant reductions in FT (6.4 ± 2.5 min vs. 32.5 ± 10.05) and DAP (13.9 ± 7.7 vs. 92.3 ± 63.8) were also achieved by the less experienced operator (P < 0.001). No difference was observed in acute and long-term complications or freedom from AF between fluoroscopy strategies during a 33-month median follow-up. Mean FT was maintained below 3 min in randomly selected cases performed during the follow-up period. CONCLUSION: In contrast to conventional protocols and regardless of the operator's experience, the optimized SWEET-Cryo strategy dramatically reduced fluoroscopy exposure during CB-PVI. The efficacy, safety, or added costs of the ablation procedure were not compromised.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Estudios Retrospectivos , Estudios Prospectivos , Rayos X , Flujo de Trabajo , Criocirugía/efectos adversos , Criocirugía/métodos , Resultado del Tratamiento , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
6.
J Interv Card Electrophysiol ; 66(7): 1589-1600, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36607529

RESUMEN

BACKGROUND: Adoption and outcomes for conduction system pacing (CSP), which includes His bundle pacing (HBP) or left bundle branch area pacing (LBBAP), in real-world settings are incompletely understood. We sought to describe real-world adoption of CSP lead implantation and subsequent outcomes. METHODS: We performed an online cross-sectional survey on the implantation and outcomes associated with CSP, between November 15, 2020, and February 15, 2021. We described survey responses and reported HBP and LBBAP outcomes for bradycardia pacing and cardiac resynchronization CRT indications, separately. RESULTS: The analysis cohort included 140 institutions, located on 5 continents, who contributed data to the worldwide survey on CSP. Of these, 127 institutions (90.7%) reported experience implanting CSP leads. CSP and overall device implantation volumes were reported by 84 institutions. In 2019, the median proportion of device implants with CSP, HBP, and/or LBBAP leads attempted were 4.4% (interquartile range [IQR], 1.9-12.5%; range, 0.4-100%), 3.3% (IQR, 1.3-7.1%; range, 0.2-87.0%), and 2.5% (IQR, 0.5-24.0%; range, 0.1-55.6%), respectively. For bradycardia pacing indications, HBP leads, as compared to LBBAP leads, had higher reported implant threshold (median [IQR]: 1.5 V [1.3-2.0 V] vs 0.8 V [0.6-1.0 V], p = 0.0008) and lower ventricular sensing (median [IQR]: 4.0 mV [3.0-5.0 mV] vs. 10.0 mV [7.0-12.0 mV], p < 0.0001). CONCLUSION: In conclusion, CSP lead implantation has been broadly adopted but has yet to become the default approach at most surveyed institutions. As the indications and data for CSP continue to evolve, strategies to educate and promote CSP lead implantation at institutions without CSP lead implantation experience would be necessary.


Asunto(s)
Bradicardia , Fascículo Atrioventricular , Humanos , Bradicardia/terapia , Estudios Transversales , Sistema de Conducción Cardíaco , Trastorno del Sistema de Conducción Cardíaco , Electrocardiografía , Estimulación Cardíaca Artificial , Resultado del Tratamiento
7.
Indian Pacing Electrophysiol J ; 22(6): 286-290, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35988904

RESUMEN

A 54-year-old woman with symptomatic premature ventricular contractions (PVC) was referred for electrophysiological study. The earliest activation was located at the parahisian area, so it was decided to ablate using cryoenergy. No AV conduction impairment was observed during cryomapping. PVCs were abolished after the first 15 seconds of cryoablation, without recurrence. However, after 354 seconds of cryoablation, a mild PR prolongation was followed by first degree and 2-to-1 AV block. Termination of cryoablation led to complete recovery without definitive damage and with elimination of the PVC. This case illustrates how lesion formation using cryoenergy can continue to evolve even after several minutes, highlighting the need of monitoring throughout the whole target duration.

8.
J Innov Card Rhythm Manag ; 12(9): 4688-4698, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34595054

RESUMEN

The coronavirus disease 2019 (COVID-19) pandemic has resulted in a deep restructuring of cardiovascular care, especially in the setting of cardiac arrhythmia units, which are characterized by a wide variety of clinical and interventional activities. We describe the experience of a large university hospital deeply hit during the COVID-19 health crisis (first outbreak of the pandemic), focusing on the exceptional measures implemented and their impact in terms of outcomes. We performed a retrospective study comparing the human and structural resources and the activity of a cardiac arrhythmia unit in a Spanish tertiary hospital for two consecutive periods: from January 12, 2020, to March 8, 2020 ("pre-COVID stage"), and from March 9, 2020, to May 2, 2020 ("COVID stage"). Data were contextualized within the number of confirmed COVID-19 cases in the region of Madrid. The measures implemented were promotion of non-face-to-face consultations, selection of urgent procedures, design of a "COVID-free" circuit for outpatient interventions, and protocolization for patients with COVID-19. A total of 3,526 consultations and 362 procedures were performed. During the COVID stage, the number of consultations remained stable, and the electrophysiology rooms' activity decreased by 55.2% with a relative increase in the number of urgent-hospitalized cases attended (11.8% COVID-19-positive patients). The electrophysiology rooms' activity returned to "normal" in the last week of the COVID stage, with no contagion being detected among patients or professionals. In conclusion, the measures implemented allowed us to respond safely and efficiently to the health care needs of patients with arrhythmias during the COVID-19 crisis and may be useful for other institutions facing similar situations.

9.
J Cardiovasc Electrophysiol ; 32(8): 2343-2345, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34196993

RESUMEN

INTRODUCTION: A middle-age woman underwent an electrophysiologic study due to recurrent atypical atrial flutter. METHODS AND RESULT: Radiofrequency ablation of cavotricuspid isthmus and anterior mitral line was performed. During energy delivery on the anterior left atrial wall, interatrial dissociation and complete block of the sinus impulse to the atrioventricular (AV) node was observed. AV node activation became dependent on a subsidiary left atrial rhythm. CONCLUSION: Anatomical location of intra and inter-atrial connections must be taken into account when performing extensive ablation procedures, specially in cases with prior cardiac surgeries.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/cirugía , Nodo Atrioventricular/diagnóstico por imagen , Nodo Atrioventricular/cirugía , Femenino , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Humanos , Bloqueo Interauricular , Persona de Mediana Edad
10.
Eur Heart J Case Rep ; 3(2)2019 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-31449611

RESUMEN

BACKGROUND: Left ventricular assist devices (LVAD) are increasingly used in patients with advanced heart failure, many of whom have been or will be implanted with an implantable cardioverter defibrillator (ICD). Interaction between both devices is a matter of concern. Subcutaneous ICD (S-ICD) obtains its signals through subcutaneous vectors, which poses special challenges with regards to adequate performance following LVAD implantation. CASE SUMMARY: We describe the case of a 24-year-old man implanted with an S-ICD because of idiopathic dilated cardiomyopathy, severe biventricular dysfunction, and self-limiting sustained ventricular tachycardias. After the implantation of a HeartMate 3™ (Left Ventricular Assist System, Abbott) several months later, the S-ICD became useless because of inappropriate sensing due to electromagnetic interference and attenuation of QRS voltage. DISCUSSION: We reviewed the reported cases in PubMed about the concomitant use of S-ICD and LVAD. Seven case reports about the performance of S-ICD in patients with an LVAD were identified, with discordant results. From these articles, we analyse the potential causes for these differing results. Pump location and operating rates in LVAD, as well as changes in the subcutaneous-electrocardiogram detected by the S-ICD after LVAD implantation are related to sensing disturbances when used in the same patient.

11.
Int J Cardiovasc Imaging ; 35(9): 1627-1636, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31041633

RESUMEN

Intraventricular velocity distribution reflects left ventricular (LV) diastolic function and can be measured non-invasively by flow mapping technologies. We designed our study to compare intraventricular velocities and gradients, obtained by vector flow mapping (VFM) technology during early diastole in consecutive patients diagnosed with mild and advanced diastolic dysfunction at echocardiography and a control group with a purpose to validate the hypothesis of relationship between new parameters and severity of diastolic dysfunction and conventional markers of elevated LV filling pressure. Two-dimensional streamline fields were obtained using VFM technology in 121 subjects (57 with normal diastolic function, 38 with mild diastolic dysfunction and 26 with advanced diastolic dysfunction). We measured several velocities and calculated a gradient along the selected streamline, which we compared between groups and correlated them with conventional echocardiographic parameters. Apical intraventricular velocity gradient (GrIV) was the lowest in control group, followed by mild and advanced diastolic dysfunction groups (5.3 ± 1.9 vs. 6.8 ± 2.5 vs. 13.6 ± 5.0/s, p < 0.001) and showed good correlation with E/e' (r = 0.751, p < 000.1). GrIV/e' ratio was the strongest single predictor of severity of diastolic dysfunction. Different degrees of diastolic dysfunction affect the Intraventricular velocity behavior during early diastole obtained by VFM. GrIV could discriminate between groups with different levels of diastolic dysfunction and was closely associated with classical echocardiographic indices of elevated LV filling pressure. GrIV/e' ratio has a potential to become a single parameter needed to assess left ventricular diastolic function.


Asunto(s)
Ecocardiografía Doppler en Color/métodos , Ecocardiografía Doppler de Pulso/métodos , Interpretación de Imagen Asistida por Computador/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Presión Ventricular , Adulto , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Estudios de Casos y Controles , Diástole , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Datos Preliminares , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Disfunción Ventricular Izquierda/fisiopatología
13.
J Am Soc Echocardiogr ; 32(6): 744-754.e1, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30904368

RESUMEN

BACKGROUND: Optimal atrioventricular delay (AVD) achieves maximum cardiac output in patients undergoing cardiac resynchronization therapy (CRT). Nonoptimal AVD decreases left ventricular (LV) end-diastolic volume and causes loss of flow momentum prior to LV ejection. OBJECTIVE: We investigated the potential role of energy dissipation (ED) in these changes in cardiac output through the study of intraventricular flow. We hypothesized that short and long AVD increases ED when compared with optimal AVD by altering the physiologic flow mechanics that preserve kinetic energy in the LV. METHODS: Forty-four patients under CRT underwent echocardiographic LV flow analysis under optimal, short, and long AVD. LV ED and vortical flow in the inflow-outflow tract were studied during the end-diastolic and early systolic period, and paired comparisons were obtained between optimal and nonoptimal values. RESULTS: ED in the left ventricle was minimal in optimal AVD and significantly increased with nonoptimal values (79.1 ± 27.5 J/m·sec in optimal AVD vs 96.5 ± 34.7 J/m·sec in short AVD; n = 18, P = .006; 123.3 ± 67.6 J/m·sec in optimal AVD vs 292.4 ± 202.5 J/m·sec in long AVD; P < .001). Increase in ED occurred due to inadequate flow redirection toward the outflow tract in short AVD and due to both turbulence and prolonged ineffective flow rotation in long AVD. CONCLUSIONS: Optimal AVD in resynchronization therapy favors physiological vortex flow patterns in the left ventricle during the end-diastolic and early systolic period. These patterns are altered when nonoptimal values are programmed, increasing ED.


Asunto(s)
Nodo Atrioventricular/fisiopatología , Gasto Cardíaco , Terapia de Resincronización Cardíaca , Ecocardiografía/métodos , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Anciano , Velocidad del Flujo Sanguíneo , Femenino , Corazón , Sistema de Conducción Cardíaco/fisiopatología , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Estudios Prospectivos
14.
J Cardiovasc Electrophysiol ; 30(5): 781-784, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30688386

RESUMEN

We present the case of a 45-year-old male patient with dilated cardiomyopathy who suffers from multiple implantable cardioverter defibrillator (ICD) shocks. The analysis of the ICD tracing and the electrophysiological study allows to conclude that bundle branch re-entrant tachycardia is the most likely diagnosis, even in absence of conduction abnormalities in his basal electrocardiography.


Asunto(s)
Cardiomiopatía Dilatada/complicaciones , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Taquicardia Ventricular/prevención & control , Potenciales de Acción , Cardiomiopatía Dilatada/diagnóstico , Cardiomiopatía Dilatada/fisiopatología , Cardioversión Eléctrica/efectos adversos , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Falla de Prótesis , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
16.
J Interv Card Electrophysiol ; 53(2): 141-150, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30109525

RESUMEN

PURPOSE: Contact force (CF) catheters are useful to address proper contact during ablation. However, interactions between the ablation process, or its associated irrigation flow changes, with the CF sensing may translate into unexpected CF value fluctuations. We aimed to test for unintentional CF value variations during radiofrequency applications at a fixed applied force, with two commercially available catheters (TactiCath™ and SmartTouch™), and to evaluate its theoretical clinical significance by correlating CF-derived automatic ablation algorithms (force-time integral and lesion index) and actual lesion size at two standard CF values. METHODS: Four series of 20 perpendicular epicardial ablations (20 W, 60 s, 17 ml/min) were performed on porcine left ventricle submerged in 37 °C saline. Catheters were mechanically fixed at a constant position and evaluated at 10 and 20 g. CF values were digitally analysed before each application changing irrigation rate (2-17-30 ml/min), and during ablation. Finally, lesions were quantified. RESULTS: Increasing irrigation before ablation led to a slight but significant CF decrease. During ablation, CF showed a reproducible pattern: fast initial decrease, subsequent increase until higher-than-initial values and final plateau phase (CF variation up to 69% at 10 g). CF variability was significantly higher at 10 g and using TactiCath™. There were no major differences in lesion size between catheters at the same initial CF. CF only correlated mildly to lesion measures, and automatic algorithms globally failed to predict lesion size. CONCLUSIONS: CF measured values spontaneously vary during ablation following a predictable pattern (initial decrease, subsequent increase and final plateau). This is especially remarkable applying lower CF.


Asunto(s)
Catéteres Cardíacos , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas , Animales , Ablación por Catéter/instrumentación , Impedancia Eléctrica , Diseño de Equipo , Seguridad de Equipos , Ventrículos Cardíacos/cirugía , Modelos Lineales , Sensibilidad y Especificidad
19.
Circ Arrhythm Electrophysiol ; 10(5): e004927, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28500176

RESUMEN

BACKGROUND: Flow entering the left ventricle is reversed toward the outflow tract through rotating reversal flow around the mitral valve. This was thought to facilitate early ejection, but had not been proved to date. We hypothesized that perfect coupling between reversal and ejection flow would occur at optimal atrioventricular delay (AVD), contributing to its hemodynamic superiority, and evaluated its applicability for AVD optimization. METHODS AND RESULTS: Forty consecutive patients with cardiac resynchronization therapy underwent intracardiac flow analysis and AVD optimization. Reversal and ejection flow curves were studied. The presence and duration of reversal-ejection discontinuity were assessed for all programmed AVD. Reproducibility of each optimization method was evaluated through interobserver variability. Discontinuity between reversal and ejection flow was observed in all patients with longer than optimal AVD, increasing linearly with excess duration in AVD (linear R2=0.976, P<0.001). Longer discontinuities implied progressive decreases in pre-ejection flow velocity in the left ventricular outflow tract, with consequent loss of flow momentum. The equation optimal AVD=programmed AVD-[1.2(discontinuity duration)]+4 accurately predicted optimal AVD. Short AVD systematically compromised reversal flow because of premature ejection. Agreement over optimal AVD was superior when assessed by flow reversal method (intraclass correlation coefficient =0.931; P<0.001) over both iterative and aortic velocity-time integral methods. CONCLUSIONS: Perfect coupling between mitral-aortic flow reversal and ejection flow in the left ventricle occurs at optimal AVD. As a result, full blood momentum in the outflow tract is used to facilitate early ejection. This can be measured and provides a new method for AVD optimization.


Asunto(s)
Aorta/fisiopatología , Nodo Atrioventricular/fisiopatología , Terapia de Resincronización Cardíaca/métodos , Cardiomiopatías/terapia , Válvula Mitral/fisiopatología , Volumen Sistólico , Función Ventricular Izquierda , Anciano , Anciano de 80 o más Años , Aorta/diagnóstico por imagen , Nodo Atrioventricular/diagnóstico por imagen , Cardiomiopatías/diagnóstico , Cardiomiopatías/fisiopatología , Ecocardiografía Doppler en Color , Ecocardiografía Doppler de Pulso , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Imagen de Perfusión Miocárdica/métodos , Estudios Prospectivos , Flujo Sanguíneo Regional , España , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...