1.
Z Kardiol ; 93(9): 671-8, 2004 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-15365734

RESUMEN

BACKGROUND: Results of studies concerning prevention of cardiovascular disease by treatment with macrolide antibiotics targeting C. pneumoniae infection are still controversial. This study describes the results of different tests for infection with C. pneumoniae as well as the effect of treatment with roxithromycin in patients with acute myocardial infarction (AMI) in relation to their serostatus against C. pneumoniae. METHODS: We analysed blood of 160 patients who came from the ANTIBIOtic therapy after an AMI ( ANTIBIO-) study, a prospective, randomised, placebo-controlled, double-blind study to investigate the effect of roxithromycin 300 mg/OD for 6 weeks in patients with an AMI. Anti- Chlamydia IgG-, IgA-, and IgM-antibodies of these patients were analysed by means of different test systems. RESULTS: There was a good correlation between the two IgG and IgA methods (r = 0.900, p < 0.001 and r = 0.878, p < 0.001, respectively), but marked differences in the prevalence of positive tests. This resulted in only moderate concordance values, as expressed by the Kappa coefficients, for IgG kappa = 0.611 (95% CI = 0.498-0.724, p < 0.001) and for IgA kappa = 0.431 (95% CI: 0.322-0.540, p < 0.001). No significant association between positive C. pneumonia titers and the combined clinical endpoint during the 12 month follow-up could be found. In all test systems used, patients with positive anti- C. pneumoniae titers did not benefit from roxithromycin therapy (p = ns). CONCLUSION: Depending on the test system used, there are large differences in the prevalence of anti- C. pneumoniae seropositive patients. Clinical events during the 12 month follow-up after AMI did not depend on serostatus against C. pneumoniae and treatment with roxithromycin did not influence these events, independently of the serostatus against C. pneumoniae. However, the power of this subgroup analysis was low to detect small but significant differences.


Asunto(s)
Antibacterianos/uso terapéutico , Anticuerpos Antibacterianos/sangre , Infecciones por Chlamydophila , Chlamydophila pneumoniae/inmunología , Infarto del Miocardio/tratamiento farmacológico , Roxitromicina/uso terapéutico , Antibacterianos/administración & dosificación , Distribución de Chi-Cuadrado , Infecciones por Chlamydophila/diagnóstico , Infecciones por Chlamydophila/tratamiento farmacológico , Infecciones por Chlamydophila/inmunología , Pruebas de Fijación del Complemento , Interpretación Estadística de Datos , Método Doble Ciego , Electrocardiografía , Estudios de Seguimiento , Humanos , Técnicas para Inmunoenzimas , Inmunoglobulina A/sangre , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Infarto del Miocardio/complicaciones , Infarto del Miocardio/mortalidad , Placebos , Estudios Prospectivos , Ensayos Clínicos Controlados Aleatorios como Asunto , Recurrencia , Roxitromicina/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento
2.
Z Kardiol ; 89(7): 592-8, 2000 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-10957784

RESUMEN

In patients with progressive muscular dystrophy (PMD) invasive electrophysiologic studies can detect hidden intracardiac conduction disturbances. The aim of this study was a long-term follow-up of these patients. Twelve consecutive patients (9 m, 3 f, age 28 +/- 4 yrs) without cardiac symptoms and with normal echocardiographic findings were included in the study. They suffered from different stages of PMD type Erb (n = 4), Becker-Kiener (n = 4), Duchenne (n = 2) and Landouzy-Déjerine (n = 2). At the beginning of the study all patients underwent an invasive electrophysiologic study (EPS). The follow-up of 5.5 yrs included regular clinical visits, ECGs, and Holter recordings (every 3 months) as well as an echocardiography every 6 months. In 4 patients the EPS revealed a hidden interatrial conduction disturbance (AHRS-ACS 120 +/- 18 ms), and in 10 pts an infrahisian conduction disturbance was found (HV max. 156 +/- 4 ms). Conduction defects were seen independently from the type of PMD and the stage of the disease. During the follow-up the initially hidden interatrial conduction disturbance became evident in the surface ECG in 2 of 4 pts. One of them developed paroxysmal atrial fibrillation. Five of 10 pts with an initially hidden infrahisian conduction disturbance developed an AV block grade I-III and in one case additionally a bundle branch block. Four of these pts--whose PMD showed progression or who developed congestive cardiomyopathy--needed pacemaker implantation because of a first-degree AV block + bifascicular bundle branch block (n = 1), a Mobitz II second-degree AV block (n = 1) or a third-degree AV block (n = 2). None of the pts with normal findings at the EPS showed abnormal p-waves, an AV block, or an intraventricular conduction disturbance during the follow-up. We conclude that intracardiac conduction disturbances, especially infrahisian defects including high-degree AV blocks, are a common finding in pts with PMD. Therefore a regular cardiological screening including an ECG and a Holter recording is reasonable in these patients.


Asunto(s)
Arritmias Cardíacas/etiología , Distrofias Musculares/fisiopatología , Adolescente , Adulto , Arritmias Cardíacas/diagnóstico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Cardiomiopatía Dilatada/diagnóstico , Cardiomiopatía Dilatada/etiología , Ecocardiografía , Electrocardiografía , Electrocardiografía Ambulatoria , Electrofisiología , Femenino , Estudios de Seguimiento , Bloqueo Cardíaco/diagnóstico , Bloqueo Cardíaco/etiología , Humanos , Masculino , Persona de Mediana Edad , Distrofias Musculares/complicaciones , Marcapaso Artificial , Factores de Tiempo
3.
Z Kardiol ; 89(4): 289-94, 2000 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-10868002

RESUMEN

Aim of our study was the comparison of bipolar ECG quality (with a 4 cm lead distance) at different sites within the anterior thorax to find the preferable implantation site for an ECG event recorder (ECG-ER). In 70 patients a bipolar ECG with a short electrode distance and in the vertical position was registered at the following sites: left and right subclavicular, left and right parasternal (4th-5th ICR), left and right anterior axilla (4th-5th ICR), at the heart apex and subxiphoidal. Then it was compared to the standard lead II. In 34 patients, an additional comparison between vertical and horizontal ECG registration was performed at the above mentioned sites. During implantation of an ECG-ER in 5 patients, ECG signals were compared with electrodes placed towards the skin or towards the muscle. The best ECG quality (greatest QRS amplitude, visible P-wave and pacemaker spike, measurable QT period and bundle-branch block) and the best agreement with standard lead II was found in 67% left parasternal, significant less often (p < 0.001) right parasternal (14.3%), left subclavicular (7.1%), apical (5.7%), and subxiphoidal (4.3%). In a vertical electrode position a significantly higher QRS amplitude and a more often visible P wave was found in comparison to a horizontal electrode position. In all cases, there was good agreement between bipolar surface ECG at the implantation site and ECG-ER stored signals. When the ECG-ER is positioned with electrodes towards the muscle, significant noise-signal occurred in all 5 patients. Only in 3 patients was a P wave visible, but with a slightly greater QRS amplitude than in ECG-ERs positioned with electrodes towards the skin. From these results, it is recommended to implant ECG-ERs vertically with electrodes towards the skin and in the parasternal position.


Asunto(s)
Electrocardiografía/instrumentación , Prótesis e Implantes , Adulto , Artefactos , Diagnóstico Diferencial , Electrodos Implantados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Garantía de la Calidad de Atención de Salud , Procesamiento de Señales Asistido por Computador/instrumentación , Síncope/etiología
4.
Pacing Clin Electrophysiol ; 21(11 Pt 2): 2226-31, 1998 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-9825323

RESUMEN

UNLABELLED: This study evaluated the reliability of atrial sensing, expressed as AV synchronous stimulation, in three VDD systems with the atrial sensitivity (AS) programmed to a conventional value with a 2:1 safety margin compared to most-sensitive values. We studied 34 sex- and age-matched patients with 3 VDD systems: 14 with Unity 292-07, 10 with Saphir 600, and 10 with Thera VDD (5 model 8948 and 5 model 8968i). Two 24-hour Holters were performed on consecutive days. The AS was programmed in a randomized order to its most-sensitive value or to a 2:1 safety margin. All other parameters were programmed identically. The patients underwent a myopotential oversensing test and a daily life activity protocol. A beat-to-beat analysis of the Holters was performed to determine AV synchrony. For the entire group AV synchrony with conventional AS was 98.63% +/- 2.57%, compared to 99.80% +/- 0.43% with most-sensitive values (p = 0.002). There was no difference between the three systems with conventional AS. With the most-sensitive AS, AV synchrony was: Unity 99.99% +/- 0.03%, Saphir 99.42% +/- 0.60% (P = 0.002), Thera 99.81% +/- 0.35% (ns). In the Saphir system with an atrial blanking period of 150 ms, ventricular far-field sensing could be demonstrated in 5 of 10 patients. This reduced the percentage of AV synchrony due to an unwanted mode-switch to a nontracking mode. Myopotential oversensing was not detected in any patient. CONCLUSION: The VDD systems tested under identical conditions showed reliable P wave sensing at the most-sensitive atrial sensing setting without myopotential oversensing. Ventricular far-field sensing reduced AV synchrony and must be avoided by appropriate refractory periods.


Asunto(s)
Bloqueo Cardíaco/terapia , Marcapaso Artificial , Anciano , Estimulación Cardíaca Artificial/métodos , Electrocardiografía Ambulatoria , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Procesamiento de Señales Asistido por Computador
5.
Pacing Clin Electrophysiol ; 21(11 Pt 2): 2236-9, 1998 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-9825325

RESUMEN

UNLABELLED: In single-lead VDD pacing the atrial sensitivity frequently is programmed to sensitive values. Atrial sensing of ventricular far-field signals should be reduced by differential atrial sensing. The aim of the study was to evaluate the effectiveness of this approach. METHODS: The study included 10 patients with a single-lead VDD pacemaker (Thera 8948, Lead 5032). The atrial sensitivity was set to its most sensitive value of 0.18 mV and the telemetered intraatrial EGM was continuously recorded. After atrial tracked ventricular pacing, VVI pacing was performed with pacing rates from 100 to 160 beats/min in steps of 10 beats/min and up to 165 beats/min. The peak-to-peak amplitudes of P waves (P) and ventricular far-field signals (VFFS) were measured from the recordings. The ratio P/VFFS that defines the atrial signal-to-noise ratio was calculated, and the time from stimulus to maximum of the far-field signals amplitude (Tmax) was measured. RESULTS: P measured 0.98 +/- 0.76 mV. A VFFS was visible in the atrial channel in all patients with an amplitude of 0.45 +/- 0.25 mV (range 0.01-1.0 mV), independent of the pacing rate. The ratio P/VFFS was 3.9 +/- 4.2 (range 0.9-21.0). Tmax measured 99.4 +/- 15.2 ms during sinus rhythm. A rate dependent shortening of Tmax to 92.7 +/- 11.2 ms at 140 beats/min was observed (P = 0.001). At rates above 140 beats/min no further shortening occurred. CONCLUSION: Ventricular far-field signals are measurable in the atrial channel of VDD systems and may reach considerable amplitudes, which are not rate dependent. Although differential sensing provides favorable P waves to ventricular far-field signal ratios, refractory periods are needed to avoid far-field sensing. The rate dependent shortening of the ventricular signal can be detected in the atrial channel in VDD pacing.


Asunto(s)
Bloqueo Cardíaco/terapia , Marcapaso Artificial , Anciano , Estimulación Cardíaca Artificial/métodos , Electrodos Implantados , Femenino , Humanos , Masculino , Telemetría
6.
Pacing Clin Electrophysiol ; 21(10): 1927-33, 1998 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9793089

RESUMEN

Dual chamber rate responsive pacing incorporating a mode switching option is increasingly used in patients with chronic paroxysmal atrial fibrillation and high degree AV block. Single-lead VDDR pacemakers have rarely used for this indication. The purpose of this study was to determine their reliability of atrial sensing during atrial fibrillation, the percentage of atrial synchronous ventricular pacing, and the behavior of the sinus rate outside the phases of atrial fibrillation. We studied ten patients with a single-lead VDDR pacemaker implanted for this indication. Follow-up visits were performed at predischarge and after 1, 3, 6, 12, 18, and 24 months. During the mean follow-up period of 18.9 +/- 6.9 months, the atrial sensing thresholds in sinus rhythm remained stable. Atrial synchronous ventricular stimulation was achieved in 68.7 +/- 31.2% (median 82.5%) of the whole follow-up time. All patients showed an adequate atrial rate response during sinus rhythm. Atrial fibrillation was detected by the pacemakers in 24.0 +/- 29.8% of time. In 3 of 10 patients the duration of atrial fibrillation showed a steady increase from visit to visit. The sensed amplitudes of atrial fibrillation ranged from 0.1-1.0 mV. A programmed atrial sensitivity of 0.1 mV was necessary to achieve complete sensing of atrial fibrillation. None of the patients experienced tachycardias with optimized pacemaker programming. Single-lead VDDR pacing incorporating a mode-switching option is useful in patients with high degree AV block and paroxysmal atrial fibrillation, since it provides atrial synchronous ventricular pacing in more than two-thirds of follow-up time. In a subgroup of patients, a progressive increase of the time during atrial fibrillation was demonstrated. A reliable detection of paroxysmal atrial fibrillation requires the programming of the atrial sensitivity to its most sensitive value.


Asunto(s)
Fibrilación Atrial/terapia , Estimulación Cardíaca Artificial/métodos , Bloqueo Cardíaco/terapia , Marcapaso Artificial , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Factores de Tiempo
7.
Z Kardiol ; 87(6): 453-8, 1998 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-9691415

RESUMEN

UNLABELLED: Sudden cardiac death is frequent in patients with dilated cardiomyopathy. To assess the risk of an arrhythmic event is still difficult. Here the analysis of the heart rate variability offers new possibilities. METHOD: 25 patients (18 males, 7 females, age 53 +/- 9 yrs) with dilated cardiomyopathy were included in the study. Analysis of heart rate variability assessed by time- and frequency-domain measures was determined from Holter recording. The mean follow-up was 18 +/- 5 months. RESULTS: 6 patients died (5 of sudden cardiac death, 1 of heart failure), 1 patient with an implanted defibrillator received an adequate shock. Parameters influenced by low- and mid-frequent oscillations of the heart rate were significantly lower in patients who died suddenly or had adequate shocks. The best predictive parameter was the s.d.RR: all patients with an s.d.RR < 50 ms had lethal arrhythmias whereas the s.d.RR of the surviving patients was > or = 50 ms. No significant difference was found or high frequency parameters, which are mainly influenced by parasympathetic activity. CONCLUSION: The analysis of heart rate variability is of prognostic relevance in patients with dilated cardiomyopathy. Especially the s.d.RR is able to identify patients with a high risk of a sudden cardiac death.


Asunto(s)
Arritmias Cardíacas/fisiopatología , Cardiomiopatía Dilatada/fisiopatología , Frecuencia Cardíaca/fisiología , Adulto , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Cardiomiopatía Dilatada/diagnóstico , Cardiomiopatía Dilatada/mortalidad , Enfermedad Crónica , Muerte Súbita Cardíaca/etiología , Electrocardiografía Ambulatoria , Femenino , Estudios de Seguimiento , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo
10.
Pacing Clin Electrophysiol ; 19(11 Pt 2): 1791-5, 1996 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-8945042

RESUMEN

UNLABELLED: Pacemakers provide marker annotations to facilitate the interpretation of pacemaker electrocardiograms (ECGs) and can be used in cases of suspected pacemaker malfunction or to understand pacemaker behavior. Due to the need for a programmer, only short-term evaluations are possible. We evaluated a prototype Telemetry Data Logger (TDL) designed to continuously transfer markers from the pacemaker to a conventional Holter recorder. A miniaturized telemetry receiving coil was attached to patient's skin above the pacemaker, which was programmed to transmit markers continuously. The TDL, which receives and converts markers into eight positive and eight negative deflections, ranging from -2.5 to +2.5 mV in amplitude, was connected to one channel of a conventional Holter recorder (Tracker 2). We performed 20 Holters in 13 patients who had implanted VDDR or DDDR devices from the same manufacturer and evaluated three versions of software. Marker transmission was possible in all patients, producing Holter ECGs with complete marker annotations. Artifacts occurred < 4% of the time. A 50-ms rectangular pulse was optimal for marker interpretation. The device, which was easy to use and well accepted by the patients, assisted in the diagnosis of inappropriate pacemaker programming, even when the surface ECG seemed to show regular pacemaker function. In the presence of low quality surface ECGs, marker annotations allowed the assessment of pacemaker function. The capability to annotate the onset of special algorithms, like tachycardia termination algorithms or mode switching, facilitates interpretation of pacemaker behavior, enabling a reliable assessment of the appropriateness of such algorithms. CONCLUSION: The TDL effectively enables pacemaker markers to be inscribed onto a conventional Holter recording, facilitating the interpretation of pacemaker ECGs and the diagnosis of inappropriate pacemaker programming even when not discernible from the surface ECG alone.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Electrocardiografía Ambulatoria/métodos , Marcapaso Artificial , Algoritmos , Artefactos , Electrocardiografía , Diseño de Equipo , Falla de Equipo , Femenino , Bloqueo Cardíaco/terapia , Humanos , Masculino , Persona de Mediana Edad , Miniaturización , Satisfacción del Paciente , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador , Programas Informáticos , Taquicardia/terapia , Telemetría/instrumentación
11.
Pacing Clin Electrophysiol ; 19(10): 1447-50, 1996 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-8904534

RESUMEN

Mobile phones may cause pacemaker interference. Patients with a single lead VDD pacemaker might be at special risk, since the atrial sensitivity is often programmed to low (high sensitivity) threshold values and the majority of patients are pacemaker dependent due to the underlying high degree AV block. We evaluated 31 patients with three types of single lead VDD pacemakers: 12 Unity, 292-07 (Intermedics, Inc.); 10 Thera VDD, 8948 or 8968i (Medtronic, Inc.); and 9 Saphir 600 (Vitatron, Inc.) for interference from a cellular mobile phone with a power of 2 W (D-net). For this purpose, atrial and ventricular sensitivity settings were programmed to their most sensitive values (A: 0.1-0.25 mV; V: 1.0 mV) and ventricular sensing was programmed to unipolar. With the ECG continuously monitored, the phone's extendable antenna was brought in direct contact with the patient's skin at the right sternal border, with the tip of the antenna in skin contact just below the clavicle, within 5 cm of the pacemaker connector. Then multiple phases of phone calls were performed, and the effects on the pacemakers recorded. In our group of patients with three different types of single lead VDD pacemakers, no interference could be detected using a 2-W mobile phone in the digital D-net. The programmed values remained unchanged after the interference test. Therefore, the risk of interference seems to be low for the VDD pacemakers tested, although our study design does not allow to entirely exclude the possibility of interference from a mobile phone.


Asunto(s)
Campos Electromagnéticos/efectos adversos , Marcapaso Artificial , Teléfono , Estimulación Cardíaca Artificial/métodos , Diseño de Equipo , Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo
13.
Unfallchirurg ; 94(7): 372-5, 1991 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-1925614

RESUMEN

The cruciate ligaments of older persons are thought to have diminished biomechanical properties. On the other hand, joint immobilization also leads to similar functional losses in ligaments. It can be difficult to differentiate between these factors in older and immobile persons. The anterior and posterior cruciate ligaments of six younger (average age 30 years) and six older (average age 64.7 years) donors with similar levels of activity were subjected to biomechanical testing. Each sample had to meet the following conditions: appropriate age, no chronic vascular and cardiopulmonary disease found on autopsy, no signs of osteoarthrosis and no knee injuries. The material properties of maximum stress (e.g. ACL: young/old 24/21N/mm2), elastic modulus (e.g. ACL: young/old 144/129 MPa), and strain (e.g. ACL: young/old 25/28%), did not differ significantly (p less than 0.05). This indicates that older persons who are active do not necessarily show functional losses in the cruciate ligaments. Other data found in the literature can be ascribed to immobilization influences. In this data many of the older test persons had chronic vascular insufficiency, cardiopulmonary disease or malignancies.


Asunto(s)
Envejecimiento/fisiología , Ligamento Cruzado Anterior/fisiología , Ligamento Cruzado Posterior/fisiología , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Elasticidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia