Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Ann Emerg Med ; 82(2): 194-202, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36774205

RESUMEN

STUDY OBJECTIVE: The diagnostic performance of T-wave amplitudes for the detection of myocardial infarction is largely unknown. We aimed to address this knowledge gap. METHODS: T-wave amplitudes were automatically measured in 12-lead ECGs of patients presenting with acute chest discomfort to the emergency department within a prospective diagnostic multicenter study. The final diagnosis was centrally adjudicated by 2 independent cardiologists. Patients with left ventricular hypertrophy, complete left bundle branch block, or paced ventricular depolarization were excluded. The performance for lead-specific 95th-percentile thresholds were reported as likelihood ratios (lr), specificity, and sensitivity. RESULTS: Myocardial infarction was the final diagnosis in 445 (18%) of 2457 patients. In most leads, T-wave amplitudes tended to be greater in patients without myocardial infarction than those with myocardial infarction, and T-wave amplitude exceeding the 95th percentile had positive and negative lr close to 1 or with confidence intervals (CIs) crossing 1. The exceptions were leads III, aVR, and V1, which had positive lrs of 3.8 (95% CI, 2.7 to 5.3), 4.3 (95% CI, 3.1 to 6.0) and 2.0 (95% CI, 1.4 to 2.9), respectively. These leads normally have inverted T waves, so T-wave amplitude exceeding the 95th percentile reflects upright rather than increased-amplitude hyperacute T waves. CONCLUSION: Hyperacute T waves, when defined as increased T-wave amplitude exceeding the 95th percentile, did not provide useful information in diagnosing myocardial infarction in this sample.


Asunto(s)
Infarto del Miocardio , Humanos , Estudios Prospectivos , Sensibilidad y Especificidad , Infarto del Miocardio/diagnóstico , Arritmias Cardíacas , Electrocardiografía , Diagnóstico Precoz
2.
JACC Adv ; 2(3): 100342, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-38939580

RESUMEN

Background: Self-reported exercise capacity is a well-established prognostic measure in stable ambulatory patients with cardiac and pulmonary disease. Objectives: The authors aimed to directly compare the prognostic accuracy of quantified self-reported exercise capacity using the Duke Activity Status Index (DASI) with the established objective disease-severity marker B-type natriuretic peptide (BNP) in patients presenting with acute dyspnea to the emergency department. Methods: The DASI was obtained in a prospective multicenter diagnostic study recruiting unselected patients presenting with acute dyspnea to the emergency department. The prognostic accuracy of DASI and BNP for 90-day and 720-day all-cause mortality was evaluated using C-index. Results: Among 1,019 patients eligible for this analysis, 75 (7%) and 297 (29%) patients died within 90 and 720 days after presentation, respectively. Unadjusted hazard ratios (HRs) and multivariable adjusted hazard ratios (aHRs) for 90- and 720-day mortality increased continuously from the fourth (best self-reported exercise capacity) to the first DASI quartile (worst self-reported exercise capacity). For 720-day mortality the HR of the first quartile vs the fourth was 9.1 (95% CI, 5.5-14.9) vs (aHR: 6.1, 95% CI: 3.7-10.1), of the second quartile 6.4 (95% CI: 3.9-10.6) vs (aHR: 4.4, 95% CI: 2.6-7.3), while of the third quartile the HR was 3.2 (95% CI: 1.9-5.5) vs (aHR: 2.4, 95% CI: 1.4-4.0). The prognostic accuracy of the DASI score was high, and higher than that of BNP concentrations (720-day mortality C-index: 0.67 vs 0.62; P = 0.024). Conclusions: Quantification of self-reported subjective exercise capacity using the DASI provides high prognostic accuracy and may aid physicians in risk stratification. (Basics in Acute Shortness of Breath EvaLuation [BASEL V] Study [BASEL V]; NCT01831115).

3.
Clin Res Cardiol ; 111(6): 627-637, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34302189

RESUMEN

BACKGROUND: Quantifying the activity of the adrenomedullin system might help to monitor and guide treatment in acute heart failure (AHF) patients. The aims were to (1) identify AHF patients with marked benefit or harm from specific treatments at hospital discharge and (2) predict mortality by quantifying the adrenomedullin system activity. METHODS: This was a prospective multicentre study. AHF diagnosis and phenotype were centrally adjudicated by two independent cardiologists among patients presenting to the emergency department with acute dyspnoea. Adrenomedullin system activity was quantified using the biologically active component, bioactive adrenomedullin (bio-ADM), and a prohormone fragment, midregional proadrenomedullin (MR-proADM). Bio-ADM and MR-proADM concentrations were measured in a blinded fashion at presentation and at discharge. Interaction with specific treatments at discharge and the utility of these biomarkers on predicting outcomes during 365-day follow-up were assessed. RESULTS: Among 1886 patients with adjudicated AHF, 514 patients (27.3%) died during 365-day follow-up. After adjusting for age, creatinine, and treatment at discharge, patients with bio-ADM plasma concentrations above the median (> 44.6 pg/mL) derived disproportional benefit if treated with diuretics (interaction p values < 0.001). These findings were confirmed when quantifying adrenomedullin system activity using MR-proADM (n = 764) (interaction p values < 0.001). Patients with bio-ADM plasma concentrations above the median were at increased risk of death (hazard ratio 1.87, 95% CI 1.57-2.24; p < 0.001). For predicting 365-day all-cause mortality, both biomarkers performed well, with MR-proADM presenting an even higher predictive accuracy compared to bio-ADM (p < 0.001). CONCLUSIONS: Quantifying the adrenomedullin's system activity may help to personalise post-discharge diuretic treatment and enable accurate risk-prediction in AHF.


Asunto(s)
Adrenomedulina , Insuficiencia Cardíaca , Cuidados Posteriores , Biomarcadores , Diuréticos/uso terapéutico , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/tratamiento farmacológico , Humanos , Alta del Paciente , Pronóstico , Estudios Prospectivos
5.
Clin Chem ; 64(9): 1347-1360, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29941469

RESUMEN

BACKGROUND: Clinical performance of the novel high-sensitivity cardiac troponin I (Siemens-hs-cTnI-Centaur) assay is unknown. We aimed to clinically validate the Siemens-hs-cTnI-Centaur assay and develop 0/1-h and 0/2-h algorithms. METHODS: We enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI). Final diagnoses were centrally adjudicated by 2 independent cardiologists including all clinical information twice: first, using serial hs-cTnT (Roche-Elecsys, primary analysis); second, using hs-cTnI (Abbott-Architect, secondary analysis) measurements in addition to the clinically applied (hs)-cTn. Siemens-hs-cTnI-Centaur was measured at presentation, 1 h, and 2 h. The primary objective was a direct comparison of diagnostic accuracy, quantified by the area under the ROC curve (AUC), of Siemens-hs-cTnI-Centaur vs the 2 established hs-cTn assays (Roche-hs-cTnT-Elecsys, Abbott-hs-cTnI-Architect). Secondary objectives included the development of Siemens-hs-cTnI-Centaur-specific 0/1-h and 0/2-h algorithms. RESULTS: AMI was the final diagnosis in 318 of 1755 (18%) patients (using Roche-hs-cTnT-Elecsys for adjudication). The AUC at presentation for Siemens-hs-cTnI-Centaur was 0.94 (95% CI, 0.92-0.96) and comparable with 0.95 (95% CI, 0.93-0.97) for Roche-hs-cTnT-Elecsys and 0.93 (95% CI, 0.90-0.96) for Abbott-hs-cTnI-Architect. Applying the derived Siemens-hs-cTnI-Centaur 0/1-h algorithm to the validation cohort, 46% of patients were ruled out (sensitivity, 99.1%; 95% CI, 95.3-100), and 18% of patients were ruled in (specificity, 94.1%; 95% CI, 91.8-95.9). The Siemens-hs-cTnI-Centaur 0/2-h algorithm ruled out 55% of patients (sensitivity, 100%; 95% CI, 94.1-100), and ruled in 18% of patients (specificity, 96.0%; 95% CI, 93.1-97.9). Findings were confirmed in the secondary analyses using serial measurements of Abbott-hs-cTnI-Architect for adjudication. CONCLUSIONS: Diagnostic accuracy and clinical utility of the novel Siemens-hs-cTnI-Centaur assay are high and comparable with the established hs-cTn assays. ClinicalTrials.gov Identifier: NCT00470587.


Asunto(s)
Infarto del Miocardio/diagnóstico , Troponina I/sangre , Algoritmos , Dolor en el Pecho , Diagnóstico Precoz , Electrocardiografía , Femenino , Humanos , Masculino , Infarto del Miocardio/fisiopatología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...